BioSciWARE. Scientific Labware

Similar documents
BioMasher II Closed System Disposable Micro Tissue Homogenizers, Sterile & Non-Sterile

Specimen Collection

PROMOTIONS PROMOTIONS. A World of Expertise, in your Hands

MAULANA AZAD MEDICAL COLLEGE ANNUAL DEMAND: GLASSWARE ( )

HI-1017: Pharmacy Technician. Module 10 Pharmacy Equipment

PRODUCT SELECTION GUIDE

F3625 F Poxygrid Lead Ring Holder 1 $12.50

Setting up your fermentation

Purchase Guide STANDARD BIOLOGY LABORATORY SUPPLIES. SCIENTIFIC Your Safer Source for Science. from

Coffee Makers. & Accessories.

Unsere aktuellste Innovation:

Density Measurement of Petroleum Products by Hydrometer Method ASTM D287 - ASTM D IP API ASTM D6822

Smart Valve Cold Brew Coffee Maker { Instruction Manual

QUALITY DURABLE STRONG PROFESSIONAL COOKWARE


Experiment 6 Thin-Layer Chromatography (TLC)

EXTRACTION PROCEDURE

Measuring Fluoride in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

» Red wine mash flooder FD-MÜ

CORAVIN APAC Product Catalogue

We make your job easy cutomer service team of products experts to get you what you need fast.

Vulcan Conical Spring Type Seals. Section

HARVEST & POST-HARVEST PRACTICES. Harvest Fermentation Drying Micro-fermentation HARVESTING FERMENTATION

EXTRACTION OF SEDIMENTS FOR AROMATIC AND CHLORINATED HYDROCARBONS

Density Measurement of Petroleum Products by Hydrometer Method ASTM D287 - ASTM D IP API ASTM D ASTM D ISO 3675

Advanced Yeast Handling. BFD education Kai Troester

Pizza. Aluminium Plate. Double Non-Stick Pan. Blue Steel Pan. Cutter. Cutter Non-slip Handle. Cutter Santoprene Handle. Cutter Como S/S Handle

Storage & Disposable Ware 17

Family and Consumer Sciences 1

Bromine Containing Fumigants Determined as Total Inorganic Bromide

Yeast nuclei isolation kit. For fast and easy purification of nuclei from yeast cells.

For Jura parts, repairs & tech support, contact: Services Unlimited, Inc./ Parts Guru

CHEM Experiment 4 Introduction to Separation Techniques I. Objectives

PAPER DRINK CUPS QUALITY DISPOSABLE PAPER & PLASTIC PACKAGING FOR EVERY OCCASION

ASSET EZ4-NCO Dry Sampler Extraction Procedure.

Dear Friends of good taste, With the right combination of various herbs and spices, any dish can be transformed into a flavoursome delight.

CERTOMAT IS For controlled benchtop incubation

C27 Chromatography. Collect: Column Mortar and pestle Dropper (229 mm) Capillary tube TLC plate Aluminum foil UV light

...Laboratory Plasticware

Overview. Hydrometer Selection. About Specific Gravity. Conditions Affecting Hydrometer Accuracy

Liquajuice Pro Slow juicer

Home canning From Wikipedia, the free encyclopedia

LINEAR GUIDES. Aluminum Roller Guides

DNA Extraction from Radioative Samples Grind plus kit Method

Fruits. Food Preservation. Important fruit canning pointers. Equipment. Canning jars. Syrup solutions WP

(12) Patent Application Publication (10) Pub. No.: US 2011/ A1

YEAST STARTERS. Brewers make wort, YEAST MAKE BEER. A few keys to turning GOOD homebrew into GREAT homebrew

Interpretation Guide. Yeast and Mold Count Plate

Veterinary Medicine Comprehensive solutions for blood collection in veterinary medicine

TURBOMIXERS AND PREMIXERS. VERTIMIX TURBOMIXER GTM SERIES TURBOMIXER GTM TANK-LESS SERIES TURBOMIXER GMG SERIES PREMIXER PCG SERIES

COLD BREW SYSTEM. Brewing Guide Toddy, LLC. All rights reserved.

Features. Before first use


PRACTICAL RUGGED STYLISH UNIQUE TABLETOP ACCESSORIES

Commercial Ovens. trimarkusa.com

I. INTRODUCTION I ITEMS:

Freezing Fruits and Vegetables

Pour Over Coffee Kit { Instruction Manual

Grooving Tool: used to cut the soil in the liquid limit device cup and conforming to the critical dimensions shown in AASHTO T 89 Figure 1.

Beer bitterness and testing

Freezing Fruits and Vegetables

Optimal solutions for your success.

YOUR MATERIAL HANDLING NEEDS

FOOD MACHINE ATTACHMENTS AND ACCESSORIES

CRUCIBLE ASSEMBLY CRUCIBLE ASSEMBLY LID ASSEMBLY SLIDER ASSEMBLY TOP FLANGE TOP GLASS MOUNTING RODS CENTRAL FLANGE BOTTOM GLASS BOTTOM FLANGE

Born of Necessity. snappies. Collect, store and feed using a single innovative breast milk container

STAINLESS STEEL. Hollowware Barware

POWERED BY NITRO COLD BREW COFFEE FULL EQUIPMENT LINE

Separations. Objective. Background. Date Lab Time Name

Bag-In-Box Package Testing for Beverage Compatibility

WORLD VINYARDS WINE KITS

POWERED BY COLD BREW NITRO COFFEE FULL EQUIPMENT LINE

DNA extraction method as per QIAamp DNA mini kit (Qiagen, Germany)

MEYER COOKING FOR ME T 20CM / 8" DEEP FRYPAN W/SPOUTS 20CM / 8" FRYPAN 24CM / 10" FRYPAN 26CM / 10.5" FRYPAN 28CM FRYPAN

Water Technologies & Solutions. wine processing. 21 st century membrane technology

Pneumatic Cylinders Cartridge Cylinders Series P1G

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

ZPM Mixer. Continuous mixing system

PECTINASE Product Code: P129

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE YM TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES.

Ground beef. Contents. Contents.

mott corporation P o r o u s M e t a l P r o d u c t s High-efficiency gas/liquid contacting.

1. Blender: Osterizer, 10-speed, or equivalent. 2. Separatory Funnel: Kilborn or equivalent (see figure 1) 2. HCl Solution: HCl/water (7:93 by volume)

Judging Canned Fruits and Fruit Juices

SERVICE MANUAL ESPRESSO COFFEE BREWER UNITS

EBI 10 High Precision Wireless Data Loggers

All in One Wine Pump. Rack-Bottle-Degas-Filter

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

HONEY. Food and Agriculture Organization of the United Nations

Professional. isi North America

Extraction of Phenolic Acids from Plant Tissue Using Accelerated Solvent Extraction (ASE )

ZenUrban Product Update; Available Q Contents. Introduction. Daryl Shatto 9/27/2013

TISSUE PREPARATION FOR LASER MICRODISSECTION (LCM) WITH ETHANOL:ACETIC ACID FIXATION

Activity Instructions

EXAMPLES OF WHAT PLATES CAN LOOK LIKE

Elixir of WELLNESS. Thanks to the juicer technology, you can taste a juice which is a real concentrate of healthy nutrients.

Please read all directions before using the product and retain this guide for reference. This product is intended for household use only.

Introduction. No Hassle Guarantee

Application & Method. doughlab. Torque. 10 min. Time. Dough Rheometer with Variable Temperature & Mixing Energy. Standard Method: AACCI

Baker Perkins Inc 3223 Kraft Ave SE Grand Rapids, MI USA. Baker Perkins Ltd Manor Drive Paston Parkway Peterborough PE4 7AP United Kingdom

Transcription:

BioSciWARE Scientific Labware

BioSciWARE Tissue Grinders Wheaton Tissue Grinders enable primary cells to be prepared from excised tissues, as well as subcellular components from harvested cell packs. Tissue grinders are used to extract DNA, RNA and proteins for blots or other procedures. They are also used to enhance recovery of other cell products. Capacities on the grinders range from 0.1 ml to 55 ml. There are a variety of grinders to suit many tissue types. Tapered Tissue Grinders are ideal for connective tissue including heart, muscle and lung. These glass-on-glass grinders feature a long taper design that maximizes grinding efficiency. Potter-Elvehjem Tissue Grinders incorporate a serrated pestle design to disperse homogenate into the mortar cylinder. Standard units with Teflon pestles are well suited for soft tissue, such as brain and liver. Tenbroeck Tissue Grinders have a hollow handle that allows packing with ice, making them suitable for tissue such as liver, intestines and heart. Dounce Tissue Grinders are supplied with two types of pestles: a loose-fitting pestle for sample reduction and a second, tighter pestle for complete homogenization. The ball-shaped pestles leave cell nuclei intact in soft tissues. The Wheaton Micro Tissue Grinder Kit offers a complete selection of micro tissue grinders. All Wheaton tissue grinders are manufactured from Wheaton 33 low extractable borosilicate glass that conforms to USP Type I and ASTM E-438 Type I, Class A requirements and replacement parts can be purchased separately. Dounce Tissue Grinder Ideal for soft tissue Provided with loose and tight pestle Wheaton 33 low extractable borosilicate glass 06-434 1 11 x 48 125 2 06-435A 7 13 x 82 175 2 06-435B 15 22 x 94 210 2 06-435C 40 32 x 140 285 2 Dounce Dura-Grind Tissue Grinder Rugged alternative to glass Dounce Tissue Grinder Precision machined from No. 316 stainless steel Mortar and pestle provided as a matched set Not autoclavable 08-414-20A 7 35 x 114 171 1 08-414-20C 15 35 x 114 171 1 02-911-523 40 44 x 114 171 1 1

Tissue Grinders Potter-Elvehjem Tissue Grinder Ideal for tissue homogenates Use with power homogenization Parts interchangeable Teflon Pestle 22-290-066 2 11 x 45 203 2 22-290-067 5 13 x 66 219 2 08-414-14A 10 16 x 74 219 2 08-414-14B 15 19 x 84 219 2 08-414-14C 30 24 x 118 266 2 08-414-14D 55 30 x 130 266 2 Potter-Elvehjem Tissue Grinder with Radial Serrations Mortar made from Wheaton 33 low extractable borosilicate glass Radial serrated Teflon pestle Interchangeable parts 02-911-524 2 11 x 45 203 2 02-911-525 5 13 x 66 219 2 02-911-526 10 16 x 74 219 2 02-912-609 15 19 x 84 219 2 02-911-527 30 24 x 118 266 2 02-911-528 55 30 x 130 266 2 Potter-Elvehjem Safe-Grind Tissue Grinder Exterior plastic coated glass mortar provide greater safety Ideal for tissue homogenates Mortar made from Wheaton 33 low extractable borosilicate glass PTFE pestle with stainless steel shaft can be used with power homogenization 08-414-16A 2 11 x 45 203 2 08-41416C 5 13 x 66 219 2 08-414-19 10 16 x 74 219 2 08-414-16G 15 19 x 84 219 2 08-414-16J 30 24 x 118 266 2 08-414-16M 55 30 x 130 266 2 Potter-Elvehjem Micro Tissue Grinder Made from Wheaton 33 low extractable borosilicate glass Micro size for extremely precise work Reservoir and pouring lip are incorporated into the design 08-414-15A 0.1 4 x 65 110 2 08-414-15B 0.2 4 x 33 115 2 2

Tapered Tissue Grinder Homogenizes connective tissue including heart, muscle and lung Made from Wheaton 33 low extractable borosilicate glass Interchangeable components 02-911-529 1 11 x 49 130 1 02-912-610 3 11 x 86 220 1 02-912-611 5 13 x 93 220 1 02-912-612 15 18 x 114 240 1 Tenbroeck Tissue Grinder Ideal for grinding liver, intestine and heart tissue Made from Wheaton 33 low extractable borosilicate glass Hollow pestle can be packed with ice Pour lip on mortar 08-414-18 1 11 x 48 140 2 08-414-13A 2 11 x 50 140 2 08-414-13B 7 16 x 82 190 2 08-414-13C 15 22 x 94 250 2 08-414-13D 40 32 x 140 320 2 Tapered Tissue Grinder Teflon pestle with stainless steel rod fits power homogenizer Homogenizes soft tissue such as brain Mortar made from Wheaton 33 low extractable borosilicate glass Interchangeable components 02-912-613 1 11 x 49 130 1 02-911-534 3 11 x 86 220 1 02-911-535 5 13 x 93 220 1 02-911-536 15 18 x 114 240 1 Disposable Micro Tissue Grinder Disposable tissue grinder eliminates cross contamination Useful for radioactive samples Small grinder area allows for high sample recovery Made from Wheaton 33 low extractable borosilicate glass Cat. No. Size (ml) ID x Length (mm) Overall Length (mm) Qty/Case 02-913-300 0.75 8 x 44 88 25 3

Tissue Grinders Roller Bottles Reusable Strong borosilicate glass to withstand repeated wet or dry sterilization 38, 45 or 51 mm screw thread Micro Tissue Grinder Kit Made from Wheaton 33 low extractable borosilicate glass Complete kit includes 7 micro tissue grinders Replacement parts available separately 08-414-17 Complete Kit 1 Kit Replacement Parts Cat. No. Description Qty/Kit Qty/Case 08-414-18 1 ml Tenbroeck Tissue Grinder 1 2 02-911-522 0.5 ml Tissue Grinder, G.P.I. 13-425 cap 1 2 06-434 1 ml Dounce Tissue Grinder 1 2 08-414-15A 0.1 ml Tissue Grinder 1 2 08-414-15B 0.2 ml Tissue Grinder 1 2 22-290-066 2 ml Potter-Elvehjem Tissue Grinder 1 2 02-912-613 1 ml Tapered Tissue Grinder 1 1 Dia x Flat Overall Usable Approx Cat. No. Length (mm) Surface Area (cm 2 ) Surface (cm 2 ) Capacity (ml) Qty/Case Roller bottle with 38 mm deep skirted, black phenolic screw cap with white styrene-butadiene rubber liner (G.P.I. 38-415) 06-44-2A 110 x 240 550 680 1380 4 06-417 110 x 285 700 840 1760 4 02-911-291 110 x 480 1320 1500 3450 4 06-442D 110 x 550 1555 1680 4230 4 Roller bottle with 45 mm white polypropylene screw cap with inner sealing ring, and polypropylene pour ring. This bottle can also be used with the Vented Cap (Cat. No. 22-288-526) 06-442-1A 110 x 240 550 680 1380 4 06-442-1B 110 x 285 700 840 1760 4 Roller bottle with 51 mm black phenolic screw cap with shallow skirt and white styrene-butadiene rubber liner (G.P.I. 51-400) 06-455C 110 x 270 700 840 1760 4 02-913-302 110 x 355 940 1070 2500 4 02-913-303 110 x 535 1555 1680 4230 4 4

Trypsinizing Flasks W heaton trypsinizing flasks are used to further reduce tissue to cellular components. Place tissue in flask, add trypsin and stir the vessel using the Wheaton Micro-Stir Magnetic Stirrer. The deep-fluted flask design promotes mixing turbulence; a dam below the sidearm retains untrypsinized tissue when decanting. Dissociated cells can then be collected. Trypsinizing flasks are also useful when removing cells from microcarrier beads. Single cells can then be used to start a seed culture in a flask or multiple flasks. After reaching a specific density, cultures can seed in a suspension culture flask or roller bottle for high volume cell production. Trypsinizing Flask Fluted design improves mixing 35 1500 ml size Graduated and non-graduated Non-Graduated Trypsinizing Flask With Pourout and Caps Fluted design improves mixing Deep skirted screw caps 35 1500 ml size Graduted and non-graduated Graduated Non-Graduated Non-Graduated Cat. No. Capacity (ml) Cap Size Flask (ml) Qty/Case 100-429A 35 24-430 50 1 100-429B 75 33-430 125 1 100-429C 150 38-430 250 1 100-429D 300 38-430 500 1 02-913-304 700 51-400 1000 1 02-911-545 1500 51-400 2000 1 Graduated Graduated Cat. No. Capacity (ml) Cap Size Graduations (ml) Flask (ml) Qty/Case 10-042-10A 35 24-430 Every 5 50 1 10-042-10B 75 33-430 10, 25, 50, 75 125 1 10-042-10C 150 38-430 50, 75, 100, 150 250 1 10-042-10D 300 38-430 80, 100, 150, 300 500 1 02-911-546 700 51-400 Every 100 1000 1 10-042-10E 1500 51-400 Every 150 2000 1 Non-Graduated Cat. No. Capacity (ml) Top Screw Cap Size Flask (ml) Qty/Case 10-042-11A 35 24-430 50 1 10-042-11B 75 33-430 125 1 10-042-11C 150 38-430 250 1 10-042-11D 300 38-430 500 1 10-042-11E 700 51-400 1000 1 10-042-11F 1500 51-400 2000 1 Graduated Cat. No. Capacity (ml) Top Screw Cap Size Graduations (ml) Flask (ml) Qty/Case 10-042-12A 35 24-430 Every 5 50 1 10-042-12B 75 33-430 10, 25, 50, 75 125 1 10-042-12C 150 38-430 50, 75, 100, 150 250 1 10-042-12D 300 38-430 80, 100, 150, 300 500 1 10-042-12E 700 51-400 Every 100 1000 1 10-042-12F 1500 51-400 Every 150 2000 1 5

Trypsinizing Flasks Shake Flask Maximizes aeration for improved growth Break resistant lip Nephelo Culture Flask For use with colorimeter or spectrophotometer Scratch and striation free side tube Cat. No. Capacity (ml) Sidearm Size (mm) Qty/Case 10-181-8A 500 14 x 130 1 Nephelo Culture Flask With Cleanout Port and Caps For use with colorimeter or spectro photometer Scratch and striation free side tube Three baffle flask Four baffle flask Cat. No. Capacity (ml) Qty/Case With Three Baffles 10-042-7A 50 1 10-042-7B 125 1 10-042-7C 250 1 10-042-7D 500 1 10-042-7E 1000 1 10-042-7F 2000 1 With Four Baffles 10-042-8A 50 1 10-042-8B 125 1 10-042-8C 250 1 10-042-8E 500 1 10-042-8F 1000 1 Erlenmeyer Flask Ideal for media storage and cell culture Made from Wheaton 33 low extractable borosilicate glass Cat. No. Capacity (ml) Volume (ml) Sidearm Size (mm) Qty/Case 10-181-9A 300 200 14 x 140 1 10-181-9 300 200 19 x 140 1 02-911-606 500 250 19 x 140 1 02-911-607 1000 600 14 x 140 1 02-911-608 1000 600 19 x 140 1 Cat. No. Capacity (ml) Cap Size Qty/Case 02-912-582 25 20-400 1 02-911-605 1000 38-430 1 6

Spinner Flasks heaton Science Products has long been an innovator in W cell culture flasks. The Wheaton Magna Flex impeller produces high-yield cultures by maintaining even circulation while keeping cultures in suspension. Slow acceleration and slow stop from the Wheaton Micro-Stir Magnetic Stirrers prevent cell detachment from microcarriers. Wheaton also invented an adjustable impeller flask that does not have a rod extending through the top of a flask. Celstir flasks feature adjustable blade impeller for increased aeration and dimpled bottom to prevent the accumulation of cells under the impeller. When used with the Micro-Stir, which can operate at very low speeds, the Celstir flask provides an optimum environment for most suspension lines, including insect cell cultures. Hybridomas and adapted cell lines can also be grown in these spinner flasks. Sidearms on Magna Flex and Celstir vessels 500 ml and larger were widened to accommodate monitoring and control devices or media inlet/outlet lines. For more information on the line Wheaton Magnetic Stirrers, see catalog numbers 02-927-065, 02-927-072, 02-927-079, and 02-927-086. Double Sidearm Celstir Spinner Flask Impeller rod does not extend through the top of cap Sidearms for 500 ml - 8 L flask allow vented caps which enables the flask to breathe while protecting from contamination. 1:1 headspace for good gas exchange No contamination from stirring rod Completely autoclavable Cat. No. Volume (ml) Dia x H (mm) Cap Size, Top Cap Size, Sidearm Qty/Case 06-416-2A 25 38 x 122 38-430 15-415 1 06-416-2B 50 38 x 141 38-430 15-415 1 06-416-2C 125 65 x 155 51-400 33-430 1 06-416-2D 250 85 x 175 51-400 33-430 1 06-416-2E 500 110 x 190 100-400 45 mm 1 06-416-2J 1000 130 x 250 100-400 45 mm 1 06-416-2F 3000 178 x 341 100-400 45 mm 1 06-416-2G 6000 258 x 404 100-400 45 mm 1 06-416-2H 8000 293 x 445 100-400 45 mm 1 7

Spinner Flasks Jacketed Double Sidearm Celstir Spinner Flask Water jacket allows for precise temperature control Manufactured from Wheaton 33 low extractable borosilicate glass Proportioned to provide a head space ratio of 1:1 or greater Impeller rod does not extend through the top of cap Fully autoclavable PTFE faced rubber-lined caps on sidearms Cat. No. Volume (ml) Dia x H (mm) Cap Size, Top Cap Size, Sidearm Qty/Case 06-416-3A 25 54 x 134 38-430 15-415 1 06-416-3B 50 54 x 147 38-430 15-415 1 06-416-3C 125 78 x 162 51-400 33-430 1 06-416-3D 250 100 x 182 51-400 33-430 1 06-416-3E 500 130 x 195 100-400 45 mm 1 06-416-3F 1000 150 x 260 100-400 45 mm 1 Magna Flex Microcarrier Spinner Flask Designed for use with microcarrier cultures Side arms for 500 ml - 6 L flasks allow vented caps which enables the flask to breath while protecting from contamination Gentle, even stirring action Cat. No. Volume (ml) Dia x H (mm) Cap Size, Top Cap Size, Sidearm Qty/Case 06-416-1A 125 65 x 155 51-400 33-430 1 06-416-1B 250 85 x 175 51-400 33-430 1 06-416-1C 500 110 x 190 100-400 45 mm 1 06-416-1D 1000 130 x 250 100-400 45 mm 1 06-416-1E 3000 178 x 341 100-400 45 mm 1 06-416-1F 6000 258 x 404 100-400 45 mm 1 Vented Cap, 45 mm Sterile cap with 0.2 μm Gore-Tex filter Flask and bottles with 45 mm screw thread Cat. No. Description Cap Size (mm) Qty/Case 22-288-526 Vented Cap 45 4 22-288-527 Vented Cap 45 12 8

Staining/ Mounting/ Microscopy heaton offers a variety of staining dishes and Coplin W jars suitable for various histology staining. Routine staining is performed to give contrast to the tissue being examined, as without staining it is very difficult to see differences in cell morphology. Hematoxylin and eosin (abbreviated H&E) are the most commonly used stains in histology and histopathology. Hematoxylin colors nuclei blue, eosin colors the cytoplasm pink. To see the tissue under a microscope, the sections are stained with one or more pigments. There are hundreds of various techniques which have been used to selectively stain cells and cellular components. Other compounds used to color tissue sections include Safranin, Oil Red O, Congo red, Fast Green FCF, Silver salts and numerous natural and artificial dyes that were usually originated from the development dyes for the textile industry. Wheaton staining dishes, covers, and racks are manufactured from soda-lime glass that resists staining from Eosin or Hematoxylin. Staining dishes are available in many configurations to accommodate up to 50 slides, with various glass and stainless steel racks. Coplin jars can be used for pre-staining with an alcohol buffer. Slides are held vertically for easy manipulation. A Coplin jar can also serve as a preparation chamber for micro thin layer chromatography. Staining Dish, 50-Slide Unit Stainless steel rack holds 50 slides 08-813A Complete (Dish, Cover, Rack) 6 22-029-567 Dish 3 22-031-300 Cover 3 08-813C Dish and cover 3 22-029-568 50-Slide Stainless Steel Rack, with Handle Attached 3 Staining Dish, 10-20 Slide Unit Holds 10 single slides or 20 slides back to back 08-811 Staining Dish and Cover 6 Staining Dish, 10-20 Slide Unit Holds 10 single slides or 20 slides back to back 08-812 Complete (Dish, Cover, Rack, Handle) 6 22-209-148 Dish 3 22-312-139 Cover 3 08-812-1A Dish and Cover 3 08-812-1B Glass Slide Rack 3 08-812-1C Handle 6 9

Staining Dish, 16-40 Slide Unit Staining Ware Dish accommodates 16, 20 or 30 slide racks Select a glass or stainless steel rack 16-32 rack holds 16 slides or 32 slides back to back 20-40 rack holds 20 slides or 40 slides back to back 02-912-616 Dish and Cover 6 22-309-245 Dish 3 22-309-246 Cover 3 02-927-094 30-Slide Rack Stainless Steel with hinged handle 3 02-912-615 (16-32) Slide Rack, Glass 3 02-912-617 (20-40) Slide Rack, Glass 3 Common Histology Stains Stain Common use Nucleus Cytoplasm Red Blood Cell (RBC) Collagen Fibers Specifically stains Hematoxylin General staining Blue N/A N/A N/A Nucleic acids - Blue when paired with Eosin blue eer (ergastoplasm) - Blue Eosin General staining N/A Pink Orange/Red Pink Elastic fibers - Pink when paired with Hematoxylin reticular fibers - Pink Toluidine blue General staining Blue Blue Blue Blue Mast cells granules - Purple Masson s trichrome stain Connective tissue Black Red/Pink Red Blue/Green Cartilage - Blue/green Muscle fibers - Red Mallory s trichrome stain Connective tissue Red Pale Red Orange Deep Blue Keratin - Orange Cartilage - Blue Bone matrix - Deep Blue Muscle fibers - Red Weigert s elastic stain Elastic fibers Blue/Black N/A N/A N/A Elastic fibers - Blue/Black Heidenhains azan Distinguishing cells from Red/Purple Pink Red Blue Muscle fibers - Red trichrome stain extracellular components Cartilage - Blue Bone matrix - Blue Silver stain Reticular fibers, Nerve fibers N/A N/A N/A Brown/Black Reticular & Nerve Fibers - Brown/Black Wright s stain Blood cells Bluish/Purple Bluish/Gray Red/Pink N/A Neutrophil granules - Purple/Pink Eosinophil granules - Bright Red/Orange Basophil granules - Deep Purple/Violet Platelet granules - Red/Purple Orcein stain Elastic fibres Deep Blue N/A Bright Red Pink Elastic fibres - Dark Brown Mast cells granules - Purple Smooth Muscle - Light Blue Periodic (PAS) Basement Membrane, Blue N/A N/A Pink Glycogen and other acid-schiff stain Localising carbohydrates Carbohydrates - Magenta Reference from: Michael H. Ross, Wojciech Pawlina, (2006). Histology: A Text and Atlas. Hagerstown, MD: Lippincott Williams & Wilkins. ISBN 0-7817-5056-3. 10

Staining Dish, 8-16 Slide Unit Fits 8 single slides or 16 slides backto-back Used as staining dish or TLC developing chamber Includes glass lid Coplin Staining Jar, 5-10 Slide Unit, with Screw Cap Unit holds 5 slides vertically or 10 slides back-to-back Polyproplene screw cap 60 ml capacity 02-913-306 Staining Dish 6 08-813E Coplin Jar with Screw Cap 6 02-912-618 Replacement Screw Cap, 58-400 6 Columbia Jar for Cover Slips Unit holds 4 cover slips Polyproplene screw cap with PTFE coated PE liner Coplin Staining Jar, 5-10 Slide Unit Holds 10 slides Polypropylene screw cap 55 ml capacity 02-912-636 Columbia Jar with Cap 1 02-912-637 Columbia Jar with Cap 6 08-813D Coplin Jar with Screw Cap 6 02-912-618 Replacement Screw Cap, 58-400 6 11

Staining Ware Coplin Staining Jar, 5-10 Slide Unit Fits 5 single slides or 10 slides back-to-back Extra tall lid accommodates 100 mm slides Staining Jar, 8-10 Slide Unit Fits 8 single slides or 16 slides back-to-back Wide top makes transferring slides convenient Includes glass lid 06-411-51 Staining Jar with Lid 6 22-309-247 Staining Jar with Lid 6 Coplin Staining Jar, 5-10 Slide Unit Glass Cover 65 ml lid prevents evaporation Fits 5 slides or 10 slides back-to-back Slide Grip Allows for easy and self transfer of slides to Coplin jar Holds 5 slides 22-312-143 Coplin Jar with Glass Lid 6 08-813-1 Slide Grip 2 12

Cryogenic Vials heaton cryogenic vials, caps, vial racks, and freezer W boxes are designed for simple identification and easy handling. With Wheaton plastic Cryules, both the closures and tubes are manufactured from medical-grade polypropylene with the same coefficient of expansion; this further enhances the leak proof qualities of these vials at changing temperatures. All Wheaton Cryules and racks are autoclavable up to 121 C. When autoclaving plastic Cryules, the cap must be loosened or removed to allow pressure equalization upon cooling; this prevents pressure build-up within the vial. Facts About Cryopreservation Liquid nitrogen (LN ): liquid density at the triple point is 0.807 g/ 2 ml, is inert, colorless, odorless, non-corrosive, nonflammable, and extremely cold. Liquid nitrogen boils at -196 C, and is a cryogenic fluid which is potentially capable of causing rapid burns on contact with living tissue. Cryopreservation is a process where cells or whole tissues are preserved by cooling to low sub-zero temperatures, such as (typically) 77 K or 196 C (the boiling point of liquid nitrogen). When cryoprotectant solutions are not used, the cells being preserved are often damaged due to freezing during the approach to low temperatures or warming to room temperature. A cryoprotectant is a substance that is used to protect biological tissue from freezing damage (damage due to ice formation). Cryoprotectants act like antifreeze: they lower the freezing temperature. They also increase the viscosity. Instead of crystallizing, the syrupy solution turns into an amorphous ice. Cryule Vial with Colored Caps Cryule Cryogenic Vial, Freestanding Sterile External threads 2 ml size Supplied with colored coded caps Conical bottom Fits Rack Cat. No. 03-341-18S Cat. No. Cap Color Size (ml) Dia x H (mm) Qty/Pack Qty/Case 03-341-18D White 2 12 x 46 50 500 03-341-18E Red 2 12 x 46 50 500 03-341-18F Pink 2 12 x 46 50 500 03-341-18G Yellow 2 12 x 46 50 500 03-341-18H Green 2 12 x 46 50 500 03-341-18J Blue 2 12 x 46 50 500 Cryule Cryogenic Vial, Freestanding Sterile Internal threads Silicone ring sealing system 1.2, 2 and 4 ml size Cat. No. Size (ml) Dia x H (mm) Qty/Pack Qty/Case 03-341-18N 1.2 12 x 42 50 500 03-341-18P 2 12 x 49 50 500 03-341-18Q 4 12 x 71 50 500 13

Cryogenic Vials Cryule Vial, Round Bottom Sterile Internal threads Round bottom 2, 4 and 5 ml size Color code cap inserts available separately Cryule Vial Cap Inserts Color coded for sample and lot identification Cat. No. Size (ml) Dia x H (mm) Qty/Pack Qty/Case 03-341-18K 2 12 x 48 50 500 03-341-18L 4 12 x 70 50 500 03-341-18M 5 12 x 90 50 500 Cryule Vial, Round Bottom Sterile External threads Round bottom 1 and 2 ml size White screw cap Cat. No. Color Qty/Case 06-450-195 Red 500 06-450-196 Blue 500 06-450-197 Green 500 06-450-198 Yellow 500 06-450-199 White 500 06-450-200 Assorted (100 of each color) 500 Cryule Vial Freezer Box For 1 and 2 ml Cryule Vials Holds 81 Vials Cat. No. Size (ml) Dia x H (mm) Qty/Pack Qty/Case 03-341-18B 1 12 x 24 50 500 03-341-18C 2 12 x 44 50 500 Cryule Vial, Round Bottom Non-sterile External thread Round bottom 2 ml size Screw cap included Cat. No Fits Dimensions (L x W x H) Qty/Case 12-009-30 1 ml Cryule Vials 5-1/4 x 5-1/4 x 1-1/4 in (13.3 x 13.3 x 3.1 cm) 15 12-009-31 2 ml Cryule Vials 5-1/4 x 5-1/4 x 1-3/4 in (13.3 x 13.3 x 4.4 cm) 15 Cryule Vial Rack For use with freestanding Cryule Vials Allows for one-handed cap removal Holds 50 vials Polypropylene Cat. No. Description Dia x H (mm) Qty/Case 03-341-18 2 ml Cryule Vial with Marking Area 12 x 44 1000 03-341-18A 2 ml Cryule Vial without Marking Area 12 x 44 1000 Cat. No. Well ID Dimensions (L x W x H) Qty/Case 03-341-18S 12.5 mm 7-5/8 x 4 x 7/8 in (19 x 10 x 2.2 cm) 5 14

Manufactured by: BioSciWARE, Dura-Grind, Safe-Grind, Celstir, Magna Flex, Cryule and the stylized W are registered trademarks of Wheaton Industries Inc. Gore-Tex is a registered trade mark of Gore and Associates. Teflon is a registered trade mark of E.I. dupont de Nemours. 2009 Copyright, Wheaton Industries Inc. BN0713092 Lit. No. 8281 07/09