Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with EN certified safety function (spring down)

Similar documents
Position switches FL series

Surface-Mounted Thermostat ATH series

Kämmer Series Low Flow Valves

CMC DUO. Standard version. Table of contens

Surface-Mounted Thermostat ATH series

REMAPRESS IVE. Pioneering, innovative, certified by German TÜV. HIGH PERFORMANCE vulcanizing technology

Built in Electric Fan Oven

AS450, AS600, G1, SG630

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

CERTOMAT IS For controlled benchtop incubation

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

UH8 Installation Manual. Installation. Insert clip here. Then Slide down to lock in place. Description. 2 Wiring Centre.

User Guide TEA CATER. Your Dealer. U / EN Rev

Franke Coffee Systems Evolution Plus: even more choice at the touch of a button.

Pre-Selection Plus operating unit: pre-selection and beverage selection presented with great style!

ELECTRONIC OVEN CONTROL GUIDE

PARTS CATALOG ESPRESSO EP SYSTEM

PrevaLED Bar G3. Dimension (l x w x h) 280 mm x 55 mm x 5 mm 560 mm x 55 mm x 5 mm

Scishare Coffee Machine

Mode d'emploi Gebruiksaanwijzing Gebrauchsanweisung Instructions for use Hoja de Características Istruzioni d'uso

HCA & HCA-RA Series Hermetically Sealed LVDT

User Manual - Quick Start Quide Instructions for operating your oven BO636.6 SS

TEA CATER USER MANUAL. UM_EN Part No.:

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

E N T E R P R I S E S

and Profibus DP (1-6) DIN Rail Mount Drop Connectors

LINEAR GUIDES. Aluminum Roller Guides

CAIMANO SPECIAL450 BARISTA

A N F I M Srl. Caimano: Timer / Automatico / Manuale Super Caimano: Timer / Automatico Caimano SPecial 450: Timer / Automatico

SERVICE MANUAL. Maxibrew 8.6kw 2012 Onwards version

COMMUNICATIONS Transmission Access Switching Optics Networking. DATA Servers Storage

juicing&bar equipment catalogue Ver 2.0

A N F I M Srl. Caimano On Demand. Super Caimano COFFEE GRINDER C O D Y S C O D Y - II. Model

Saeco Idea Restyle Semiautomatic table top for mid to large offices and ho.re.ca. applications

Coffeemaker User's manual

Programmable Espresso Machine

SELECTION GUIDE UNSEALED SNAP ACTION

FOR GENTLY SEPARATING FOREIGN BODIES - DESTEMMERS. Testimonial

S m a rtset Control for Convection Models

Metallized Polyester Film Capacitors (MKT-S) Axial Leads B High reliability capacitor Encapsulated in metal tube

GIGA X7. Technical data. JURA standards. Variable brewing unit, from 5 g to 16 g. Intelligent Pre-Brew Aroma System (I.P.B.A.S. )

Artisan-made ice cream, just as you like it. And much, much more...

KRONES fillers for wine and sparkling wine Filling of glass containers

Pneumatic Cylinders Cartridge Cylinders Series P1G

Machine No. 2, SV=104. Figure 1

IMPRESSA XJ5 Professional Instructions for Use. Original instructions for use Before using the machine read the instructions for use.

Centrifuge. Refrigerated Centrifuge 3-16PK

User Manual VZ46BHK VZ110BDHK/ VZ120BHK VZ150BDHK/ VZ166BHK

GAGGIA VALUES LONG ESPRESSO TRADITION AT HOME AS IN COFFEE SHOP EASY MULTIPLE CHOICE

Convection. Clock Used to set the time of day. Even-Cook Convection Ovens P R. Speed clean R B B PM CONV PRE- BAKE

TECHNICAL INFORMATION CVA615 Coffee System

Lead spacing Diameter d 1 Type

Lead spacing Diameter d 1 Type

Metallized Polyester Film Capacitors (MKT) in Plastic Case B B Standard applications

Conv. Pre Heat. Speed. bake. clean. Conv. Bake time. Clean. convert. Maxx clean. Conv. Broil. roast. Oven

SF4750VCAO. Functions. Versions. cortina. Main Oven Plus Main Oven

...WITH A PASSION FOR COFFEE. User manual. CQ Future BTC. Your retail dealer U_GB ... Rev

Beer bitterness and testing

instructions COFFEE GRINDER KG 79/89

18-Bottle Dual Zone Slimline Edition Touchscreen Refrigerator

Any questions? Contact us at Telephone:

24-Bottle 2-Temp Touchscreen Refrigerator

Dough Expert. Member of the

2007 Miele USA. TECHNICAL INFORMATION CVA615 Coffee System

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

SPeCtra S and X. Troubleshooting. read the safety information chapter before working on the machines.

QWIKBREW 2 TWIN 5.6kW (P/N: )

Oven. Self-Cleaning cycle. Oven. Clock. light. Start time. Bake time

Uno xl electronic. Turnspit.

ARIZONA COFFEE ROASTERS

START STOP. Manuale d'uso del vostro forno Le guide d'utilisation de votre four Gebruikshandleiding van uw oven

Firebox X Edge e-series Hardware

A951A/S PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

48-Bottle Dual Zone Silent Wine Refrigerator

Parts Catalog Espresso System

12 Bottle Dual Zone. Touchscreen INSTRUCTION MANUAL

PLEASE READ THIS MANUAL BEFORE USE. SAVE FOR FUTURE REFERENCE.

Operating Instructions

CHOCOLINO CAFÉLINO USER MANUAL UM_EN. Part No.: _01

» Red wine mash flooder FD-MÜ

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

DISCONTINUED VERSION The information in this manual is no longer current. Espresso/Cappuccino OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION

FTIR Analyzer. Lyza 5000 Wine

MTN Products. AquaCafé r (Touch Capsules) Installation & Operations Manual

Gravity Feed Commercial BBQ Smoker

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

OMEGA PRODUCTS, INC LYSTER LANE HARRISBURG, PA U.S.A. PHONE: FAX:

Distillation Note Books

Optimal solutions for your success.

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

Brabender Technologie GmbH & Co. KG. FDDW-S Standardized liquid feeding

Operating Instructions Bedienungsanleitung

This appliance can be used by children aged from 8 years and above and persons with

CAFFE. CAPPUCCINO. AUTOCAPPUCCINO!

The Coffee Expert. Sielissimo series. Hot drinks. vending machine. Sielissimo EC

Qty: B20 1,2 363 lm/4.7w per foot. 1B30 1,2 536 lm/7.2w per foot. 1B lm/8.6w per foot. 1B25 1,2 481 lm/6.

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

INSTALLATION AND WARRANTY CERTIFICATE. Machine model Serial Number # Rating and optional. Installation Company: Technician ID: Date: / /

Design celebrates functionality.

Transcription:

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with EN 14597 certified safety function (spring down) Description AME 10 AME 13 AME 20, AME 30 AME 23, AME 33 The actuators with or without safety function are available for the modulating controllers with the control Y signal. The actuators can be used to provide safety shut off on power failure. They are used with VS2, VM2, V2, VMV and AVQM valves. In addition to basic function such as manual control and position indication, the actuators are also equipped with force sensitive switch-off to ensure that actuators and valves are not exposed to overloading. Main data: 24 V version Force: - AME 10, 13...300 N - AME 20, 23, 30, 33...450 N Speed: - AME 10, 13...14 s/mm - AME 20, 23...15 s/mm - AME 30, 33...3 s/mm Max. medium temperature: - AME 10, 13...130 C - AME 20, 23, 30, 33...150 C End-position signals Note: The use of AME actuators together with VS2 DN 15 is not recommendable. Linear characteristics as in VS2 DN 15 valves is not recommendable in DHW production. Ordering Actuators Type Supply voltage Code No. AME 10 082G3005 AME 20 24 V 082G3015 AME 30 082G3017 Actuators with safety function - EN 14597 Type Supply voltage Code No. AME 13 082G3006 AME 23 24 V 082G3016 AME 33 082G3018 DEN-SMT/SI ED.LF.Y1.02 Danfoss 04/2014 1

Technical data Type AME 10 AME 13 AME 20 AME 23 AME 30 AME 33 Power supply V 24; +10 to 15 %; AC Power consumption VA 4 9 4 9 9 14 Frequency Hz 50/60 Safety function - x - x - x V 0-10 (2-10) Ri = 24 kω Control input Y ma 0-20 (4-20) Ri = 500 Ω Output signal X V 0-10 (2-10) Closing force N 300 450 Max. stroke mm 5 10 Speed s/mm 14 15 3 Max. medium temperature 130 150 Ambient temperature C 0 55 Storage and transport temperature 40 70 Grade of enclosure IP 54 Weight kg 0,6 0,8 1,45 1,5 1,45 1,5 Low voltage directive (LVD) 2006/95/EC: EN 60730-1, EN 60730-2-14 - marking in accordance with standards EMC Directive 2004/108/EC: EN 61000-6-2, EN 61000-6-3 Installation AME 10 AME 20, AME 30 AME 13 AME 23, AME 33 Safety function The safety function will fully open or close the valve by power failure, depending upon the chosen safety action (SD). Valve selection will also affect the safety action. The safety function unit is factory fitted to the rear of the actuator. or = SD Valve type Spring action selection will Close port A-A Open port A-A SD SD VS SD - VM (DN 15-50) SD - V (DN 15-50) SD - AVQM (DN 15-50) SD - VMV - SD VS, VM, V, AVQM VMV 2 ED.LF.Y1.02 Danfoss 04/2014 DEN-SMT/SI

Disposal The actuator must be dismantled and the elements sorted into various material groups before disposal. Manual Override A A AME 10 AME 20, AME 30 AME 13 AME 23, AME 33 DEN-SMT/SI ED.LF.Y1.02 Danfoss 04/2014 3

DIP switch setting The actuator has a function selection DIP switch under the removable cover. In particular, if SW6 is set to ON, the actuator will perform as 3-point actuator. The switch provides the following functions: SW1: U/I - Input signal type selector: If set to OFF position, voltage input is selected. If set to ON position, current input is selected. SW2: 0/2 - Input signal range selector: If set to OFF position, the input signal is in the range from 2-10 V (voltage input) or from 4-20 ma (current input). If set to ON position, the input signal is in the range from 0-10 V (voltage input) or from 0-20 ma (current input). SW3: D/I - Direct or inverse acting selector: If set to OFF position, the actuator is direct acting (stem lowers as voltage increases). If actuator is set to ON position the actuator is inverse acting (stem raises as voltage increases). SW5: 0-5 V/5-10 V - Input signal range in sequential mode: If set to OFF position, the actuator is working in sequential range 0(2)-5(6) V or 0(4)-10(12) ma. If set to ON position, the actuator is working in sequential range; 5(6)-10 V or 10(12)-20 ma. SW6: Prop./3-pnt - Modulating or 3-point mode selector: If set to OFF position, the actuator is working normally according to control signal. If set to ON position, the actuator is working as 3-point actuator. SW7: LOG/LIN - Not in use. SW8: 100 % k VS/Reduced k VS - Not in use. SW9: Reset: Changing this switch position will cause the actuator to go through a self calibration cycle. SW4: /Seq - Normal or sequential mode selector: If set to OFF position, the actuator is working in range 0(2)-10 V or 0(4)-20 ma. If set to ON position, the actuator is working in sequential range; 0(2)-5(6) V or (0(4)-10(12) ma) or (5(6)-10 V) or (10(12)-20 ma). 4 ED.LF.Y1.02 Danfoss 04/2014 DEN-SMT/SI

Wiring Wiring length Recommended square of the wiring 0-50 m 0,75 mm 2 > 50 m 1,5 mm 2 24 V AC SP SN Y X 24 V AC... Power supply 0 V...Common 0-10 V...Input signal (2-10 V) 0-20 ma (4-20 ma) 0-10 V...Output signal (2-10 V) Automatic self stroking feature When power is first applied, the actuator will automatically adjust to the length of the valve stroke. Subsequently, the self stroking feature can be re-initialised by changing position of SW9. Diagnostic LED The red diagnostic LED is located on the pcb under the cover. It provides indication of three operational states: Actuator Healthy (Permanently ON), Self Stroking (Flashes once per second), Error (Flashes 3 times per second - seek technical assistance). DEN-SMT/SI ED.LF.Y1.02 Danfoss 04/2014 5

Dimensions AME 10 AME 13 AME 20, AME 30 AME 23, AME 33 6 ED.LF.Y1.02 Danfoss 04/2014 DEN-SMT/SI

Actuator - valve combinations AME 10, AME 13 + AME 10, AME 13 + AME 10 + VM2 (DN 15-25) V2 (DN 15-20) VMV (DN 15-40) VS2 (DN 20* - 25) AME 20/30, AME 23/33 + AME 20/30, AME 23/33 + AME 20/30, AME 23/33 + VM2 (DN 15-50) V2 (DN 15-50) AVQM (DN 15-50) VS2 (DN 20* - 25) * The use of AME actuators together with VS2 DN 15 is not recommendable. Linear characteristics as in VS2 DN 15 valves is not recommendable in DHW production. DEN-SMT/SI ED.LF.Y1.02 Danfoss 04/2014 7

8 ED.LF.Y1.02 Produced by Danfoss A/S 04/2014