Weather Sensitive Adjustment Using the WSA Factor Method

Similar documents
Regression Models for Saffron Yields in Iran

STAT 5302 Applied Regression Analysis. Hawkins

Analysis of Things (AoT)

Using Growing Degree Hours Accumulated Thirty Days after Bloom to Help Growers Predict Difficult Fruit Sizing Years

OC Curves in QC Applied to Sampling for Mycotoxins in Coffee

The multivariate piecewise linear growth model for ZHeight and zbmi can be expressed as:

Climate change may alter human physical activity patterns

Acetic acid dissociates immediately in solution. Reaction A does not react further following the sample taken at the end of

Napa Highway 29 Open Wineries

Investment Wines. - Risk Analysis. Prepared by: Michael Shortell & Adiam Woldetensae Date: 06/09/2015

Uniform Rules Update Final EIR APPENDIX 6 ASSUMPTIONS AND CALCULATIONS USED FOR ESTIMATING TRAFFIC VOLUMES

Activity 10. Coffee Break. Introduction. Equipment Required. Collecting the Data

AJAE Appendix: Testing Household-Specific Explanations for the Inverse Productivity Relationship

Quality of Canadian oilseed-type soybeans 2017

Multiple Imputation for Missing Data in KLoSA

Relationships Among Wine Prices, Ratings, Advertising, and Production: Examining a Giffen Good

Panel A: Treated firm matched to one control firm. t + 1 t + 2 t + 3 Total CFO Compensation 5.03% 0.84% 10.27% [0.384] [0.892] [0.

Buying Filberts On a Sample Basis

Wine-Tasting by Numbers: Using Binary Logistic Regression to Reveal the Preferences of Experts

Trip Generation at Fast Food Restaurants

Gail E. Potter, Timo Smieszek, and Kerstin Sailer. April 24, 2015

Financing Decisions of REITs and the Switching Effect

FACTORS DETERMINING UNITED STATES IMPORTS OF COFFEE

Napa County Planning Commission Board Agenda Letter

The Development of a Weather-based Crop Disaster Program

UPPER MIDWEST MARKETING AREA THE BUTTER MARKET AND BEYOND

Flexible Working Arrangements, Collaboration, ICT and Innovation

Seasonal changes on chemical and physical parameters in six avocado (Persea americana Mill) cultivars grown in Chile

Tree diversity effect on dominant height in temperate forest

The Market Potential for Exporting Bottled Wine to Mainland China (PRC)

Missing value imputation in SAS: an intro to Proc MI and MIANALYZE

PEEL RIVER HEALTH ASSESSMENT

DELAWARE COMPENSATION RATING BUREAU, INC. Proposed Excess Loss (Pure Premium) Factors

USING STRUCTURAL TIME SERIES MODELS For Development of DEMAND FORECASTING FOR ELECTRICITY With Application to Resource Adequacy Analysis

Fair Trade and Free Entry: Can a Disequilibrium Market Serve as a Development Tool? Online Appendix September 2014

MATERIALS AND METHODS

Growing divergence between Arabica and Robusta exports

INFLUENCE OF THIN JUICE ph MANAGEMENT ON THICK JUICE COLOR IN A FACTORY UTILIZING WEAK CATION THIN JUICE SOFTENING

wine 1 wine 2 wine 3 person person person person person

THE STATISTICAL SOMMELIER

Dietary Diversity in Urban and Rural China: An Endogenous Variety Approach

Introduction to Management Science Midterm Exam October 29, 2002

Missing Data Treatments

Quality of Canadian oilseed-type soybeans 2016

Irrigation of Sunflowers in Northwestern Kansas

International Journal of Research and Review ISSN:

Demand, Supply and Market Equilibrium. Lecture 4 Shahid Iqbal

Predicting Wine Quality

Gasoline Empirical Analysis: Competition Bureau March 2005

OF THE VARIOUS DECIDUOUS and

Online Appendix to The Effect of Liquidity on Governance

Large-scale Accessory Winery Event. Large-scale accessory winery event is an event hosted by the on-site winery or off-site

Credit Supply and Monetary Policy: Identifying the Bank Balance-Sheet Channel with Loan Applications. Web Appendix

Final Exam Financial Data Analysis (6 Credit points/imp Students) March 2, 2006

6.7 Lighting maintenance

Cotton Crop Maturity Determination

Internet Appendix for CEO Personal Risk-taking and Corporate Policies TABLE IA.1 Pilot CEOs and Firm Risk (Controlling for High Performance Pay)

Wheat Market Report Monday, October 16, 2017 Friday October 20, 2017

Evaluation of Quality Characteristics and Microbial Contamination of Saffron Samples Dried by Microwave

Recipe Adjustment Factor Method

COMPARISON OF CORE AND PEEL SAMPLING METHODS FOR DRY MATTER MEASUREMENT IN HASS AVOCADO FRUIT

Curtis Miller MATH 3080 Final Project pg. 1. The first question asks for an analysis on car data. The data was collected from the Kelly

Appendix A. Table A.1: Logit Estimates for Elasticities

To: Professor Roger Bohn & Hyeonsu Kang Subject: Big Data, Assignment April 13th. From: xxxx (anonymized) Date: 4/11/2016

DEFINITIONS: Page 1 of 6 F:\DEVSVC\Planning Application Forms\ Winery or Wine Cellar Supplemental Info & Marketing Plan. Doc (Revised )

Comparative Analysis of Fresh and Dried Fish Consumption in Ondo State, Nigeria

Whether to Manufacture

Growth in early yyears: statistical and clinical insights

Imputation of multivariate continuous data with non-ignorable missingness

The R survey package used in these examples is version 3.22 and was run under R v2.7 on a PC.

McLaren Vale wine region. Regional summary report WINEGRAPE UTILISATION AND PRICING SURVEY 2007

PENNSYLVANIA COMPENSATION RATING BUREAU. Proposed Excess Loss (Pure Premium) Factors

BORDEAUX WINE VINTAGE QUALITY AND THE WEATHER ECONOMETRIC ANALYSIS

Online Appendix to Voluntary Disclosure and Information Asymmetry: Evidence from the 2005 Securities Offering Reform

Grape Growers of Ontario Developing key measures to critically look at the grape and wine industry

Emerging Local Food Systems in the Caribbean and Southern USA July 6, 2014

Zeitschrift für Soziologie, Jg., Heft 5, 2015, Online- Anhang

STA Module 6 The Normal Distribution

STA Module 6 The Normal Distribution. Learning Objectives. Examples of Normal Curves

Red wine consumption in the new world and the old world

GLOBAL ECONOMIC VITIVINICULTURE DATA

-- Final exam logistics -- Please fill out course evaluation forms (THANKS!!!)

Valuation in the Life Settlements Market

EU Sugar Market Report Quarterly report 04

How Rest Area Commercialization Will Devastate the Economic Contributions of Interstate Businesses. Acknowledgements

Online Appendix to. Are Two heads Better Than One: Team versus Individual Play in Signaling Games. David C. Cooper and John H.

Detecting Melamine Adulteration in Milk Powder

2012 Research Report Michigan Grape & Wine Industry Council

National Vintage Report 2017

Final Report to Delaware Soybean Board January 11, Delaware Soybean Board

Relation between Grape Wine Quality and Related Physicochemical Indexes

Senior poverty in Canada, : A decomposition analysis of income and poverty rates

Chapter 1: The Ricardo Model

DRY BEANS PRICES AND INCOME DISTRIBUTION IN RWANDA: A NON- PARAMETRIC ANALYSIS

IMPACT OF RAINFALL AND TEMPERATURE ON TEA PRODUCTION IN UNDIVIDED SIVASAGAR DISTRICT

State Licensing of Wine Sales in Food Stores: Impact on Existing Liquor Stores

NEW ZEALAND AVOCADO FRUIT QUALITY: THE IMPACT OF STORAGE TEMPERATURE AND MATURITY

Coonawarra Wine Region. Regional summary report WINEGRAPE UTILISATION AND PRICING SURVEY 2007

Cloud Computing CS

ECX White Pea Beans Contract

Transcription:

Weather Sensitive Adjustment Using the WSA Factor Method Alternate CBLs can be requested within elrs to compensate for the temperature differences between the CBL basis days and the temperature of the event hour. The Weather Sensitive Adjustment (WSA) factor method is one such alternate CBL that can be requested. The WSA Factor Method adjusts the hourly CBL (up or down) to compensate for the average hourly temperature differences between the CBL basis days and the temperature of the event hour. The WSA Factor represents the kw change in load for each degree of temperature change within a specified temperature range. The WSA factor is the slope of the line that describes the load and temperature relationship at the customer site between two temperature set points. The WSA Factor or slope of the line is obtained by performing a linear or piecewise linear regression analysis on the load and temperature data from the customer site. There should be at least two years of data used in the linear regression analysis to indicate the normal operation of the facility. Exceptions may be granted by PJM to use less data in cases where the normal operations have changed significantly between years. The analysis data should only include the day types and hours where load reductions are expected. For example, if the customer is only expected to respond during the hours of 8am to 6pm from Monday through Friday during nonholidays, then such historic hours should be used in the regression model. The hourly CBL Adjustment is obtained by multiplying the WSA Factor by the temperature of the event hour minus the hourly average temperature of the CBL. The hourly average temperature of the CBL is the hourly average of the basis days used for the CBL. Example 1: Hourly average temperature of the CBL for hour ending 12 = 86 Event temperature for Hour Ending 12 = 81 WSA Factor = 688 kw/ F CBL Adjustment for Hour Ending 12 = Temperature Delta * WSA Factor = (81-86 ) * 688 kw/ F = -3440 kw The CBL is adjusted down because the temperature of the event day is lower than the average hourly temperature of the CBL basis days. A simple linear regression analysis fits a straight line through the set of points (load and temperature data) in such a way that makes the sum of squared residuals as small as possible. The first and last points of the estimated line are known as the Temperature Set Points. The Slope of the line between the two Temperature Set points is the WSA factor. A piecewise linear regression analysis fits multiple contiguous straight lines through the set of data points (load and temperature data) in such a way that makes each of the sum of squared residuals as small as possible. The piecewise linear regression analysis results in multiple lines with multiple slopes that estimate the load and temperature relationship of the customer site data. The end points of each of the estimated lines are known as the Temperature Set Points. Determining the number Temperature Set Points can be accomplished by using a Piecewise Linear Regression Break Point algorithm or by data observation at points where the slope of the PJMDOCS #621890 1

data appears to change significantly. Either methodology should result in minimizing the sum of squared residuals for each of the estimated lines. Example 2: Calculate WSA Factors applicable for summer curtailments using Piecewise Linear Regression. Figure 1 shows a scatter plot of load versus temperature for a site. Since future load reductions are expected only on weekdays during hours ending 8 through hours ending 20, the load and temperature data excludes weekends, holidays and hours ending 21 through hours ending 7. Temperature set points are established at the temperatures where the slope of the estimated curve changes significantly. The temperature set points can be seen in Figure 1. The minimum temperature for a summer WSA adjustment is 60. Therefore, a regression analysis is not performed on temperature data below 60. Two linear regression analyses were performed on the data between 60 and 95. A regression analysis was not performed on temperatures at or above 95 since the air conditioning loading becomes saturated starting at 95 for this facility. When the weather sensitive load becomes saturated, a weather sensitive adjustment is not required. A piecewise linear regression analysis was performed on the data between 60 and 95 degrees. By observation, it was determined that there is a change in slope beginning at 76 degrees. Therefore, the Temperature set points were determined to be 60, 76 and 95 degrees. The first linear regression analysis was performed using a temperature range of >= 60 and less than 76. The second linear regression analysis was performed using a temperature range of >= 76 and less than 95. Each range of temperatures defines a Set Point. The slopes for each of the Set Points (temperature ranges) were calculated. An additional Temperature Set Point was arbitrarily set at 120 degrees to establish the 0 slope characteristic for the saturated load above 95 degrees. Figure 2 shows the WSA Factors at each of the Temperature set points. Figure 1: Scatter Plot of Load Versus Temperature PJMDOCS #621890 2

Example 3: Using the WSA parameters in Figure 2, CBL Adjustments are calculated for hours ending 7, 16, 17 and 18 using the WSA Factor Method. Figure 3 shows the temperatures and the WSA Factors that are used to calculate the CBL Adjustments for each hour of the settlement. Parameter Set Point Set Point Range WSA Factor (kw/ F) WSA1 60 <60 0 WSA2 76 >=60 <76 305 WSA3 95 >=76 <95 688 WSA4 120 >=95 <120 0 Figure 2: WSA Parameters Hour Ending 7 Hour Ending 16 Hour Ending 17 Hour Ending 18 Average CBL Temp 70 75 82 83 Event Day Temp 75 86 90 70 Delta Temperature 5 11 8-13 WSA Factor (kw/ F) 305 653.182 688 511.231 CBL Adjustment (kw) 1525 7185 5504-6646 Figure 3: Temps and WSA Factors An explanation of the CBL Adjustment calculations along with the selection of the WSA factors used for each hour ending of Figure 3 appears below. Hour Ending 7: The CBL is to be adjusted upward along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 70 and needs to be adjusted upward to the event temperature of 75. The CBL and Event temperatures are within the same parameter ranges. Therefore, the WSA Factor is 305 kw/ F. CBL Adjustment = 5 F * 305 kw/ F = 1525 kw. Hour Ending 16: The CBL is to be adjusted upward along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 75 and needs to be adjusted upward to the event temperature of 86. Since the CBL and Event temperatures are not within the same parameter ranges, a temperature weighted WSA Factor is calculated. WSA Factor = ((1 F * 305 kw/ F) + (10 F * 688 kw/ F)) / 11 F = 653.182 kw/ F. CBL Adjustment = 11 F * 653.182 kw/ F = 7185 kw. PJMDOCS #621890 3

Hour Ending 17: The CBL is to be adjusted upward along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 82 and needs to be adjusted upward to the event temperature of 90. The CBL and Event temperatures are within the same parameter ranges. Therefore, the WSA Factor is 688 kw/ F. CBL Adjustment = 8 F * 688 kw/ F = 5504 kw. Hour Ending 18: The CBL is to be adjusted downward along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 83 and needs to be adjusted downward to the event temperature of 70. Since the CBL and Event temperatures are not within the same parameter ranges, a temperature weighted WSA Factor is calculated. WSA Factor = ((7 F * 688 kw/ F) + (6 F * 305 kw/ F)) / 13 F = 511.231 kw/ F. CBL Adjustment = -13 F * 511.231 kw/ F = -6646 kw. Example 4: Calculate and use WSA Factors applicable for winter curtailments using Piecewise Linear Regression. A characteristic of a weather sensitive load in the winter is that the load increases as the temperature decreases. This characteristic results in a negative slope or negative WSA factor. Figure 4 shows the results of a piecewise linear regression analysis for a customer site that has weather sensitive loads when the outdoor temperature is less than 60 degrees. The maximum temperature for a winter WSA adjustment is 50 and the minimum temperature for a summer WSA adjustment is 60. It is assumed that there is no significant heating or cooling between 50 and 60. Therefore a regression analysis is not performed on data within this temperature range. For this facility, the heating load saturates out for temperatures less than 20 degrees and therefore the slope or WSA factor equals 0 kw/ F. When the weather sensitive load becomes saturated, a weather sensitive adjustment is not required. Parameter Set Point Set Point Range WSA Factor (kw/ F) WSA1 20 <20 0 WSA2 40 >=20 <40-650 WSA3 50 >=40 <50-225 WSA4 60 >=50 <60 0 Figure 4: WSA Parameter PJMDOCS #621890 4

Using the WSA parameters in Figure 4, CBL Adjustments are calculated for hours ending 7, 15, and 16 using the WSA Factor Method. Figure 5 shows the temperatures and the WSA Factors that are used to calculate the CBL Adjustments for each hour of the settlement. Hour Ending 7 Hour Ending 15 Hour Ending 16 Average CBL Temp 15 40 35 Event Day Temp 25 20 15 Delta Temperature 10-20 -20 WSA Factor (kw/ F) -325-650 -487.5 CBL Adjustment (kw) -3250 13000 9750 Figure 5: Termerature and WSA Factors An explanation of the CBL Adjustment calculations along with the selection of the WSA factors used for each hour ending of Figure 5 appears below. Hour Ending 7: The CBL is to be adjusted along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 15 and needs to be adjusted to the event temperature of 25. Since the CBL and Event temperatures are not within the same parameter ranges, a temperature weighted WSA Factor is calculated. WSA Factor = (5 F * 0 kw/ F) + ((15 F * -650 kw/ F)) / 10 F = -325 kw/ F. CBL Adjustment = 10 F * -325 kw/ F = -3250 kw. Since the slope or WSA factor is negative and the Delta Temperature is positive, the CBL is adjusted downward. Hour Ending 15: The CBL is to be adjusted along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 40 and needs to be adjusted to the event temperature of 20. The CBL and Event temperatures are within the same parameter ranges. Therefore, the WSA Factor is -650 kw/ F. CBL Adjustment = -20 F * -650 kw/ F = 13000 kw. Since the slope or WSA factor is negative and the Delta Temperature is negative, the CBL is adjusted upward. Hour Ending 16: The CBL is to be adjusted along the estimated load curve based on the temperature of the settlement event hour. The average CBL temperature is 35 and needs to be adjusted to the event temperature of 15. Since the CBL and Event temperatures are not within the same parameter ranges, a temperature weighted WSA Factor is calculated. WSA Factor = ((15 F * -650 kw/ F) + (5 F * 0 kw/ F)) / 20 F = -487.5 kw/ F. CBL Adjustment = -20 F * -487.5 kw/ F = 9750 kw. PJMDOCS #621890 5

Since the slope or WSA factor is negative and the Delta Temperature is negative, the CBL is adjusted upward. Zone Weather Station Short Name Weather Station AECO ACY Atlantic City International AEP CMH Port Columbus International APS PIT Pittsburgh International BGE BWI Baltimore Washington International COMED ORD Chicago OHare International DAY DAY Cox-Dayton International DOM RIC Richmond International DPL PHL Philadelphia International DUQ PIT Pittsburgh International JCPL EWR Newark International METED PHL Philadelphia International PECO PHL Philadelphia International PENELEC JST Johnstown Airport PEPCO DCA Washington Reagan National PPL ABE Allentown Lehigh Valley International PSEG EWR Newark International RECO EWR Newark International Table 1: Weather Stations used for each Zone PJMDOCS #621890 6