Albany Plus. Available in both matt chrome and satin brass finishes, Albany Plus brings stylish yet robust good

Similar documents
Position switches FL series

CMC DUO. Standard version. Table of contens

ZANOLLI. Pizza ovens. Spare parts for: Suitable for:

AS450, AS600, G1, SG630

instructions COFFEE GRINDER KG 79/89

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

Coffee Grinder Instruction Manual

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

Built in Electric Fan Oven

STAINLESS STEEL MILK FROTHER. Model: PKFMR11BK

Downloaded from Quick Start Guide D512. Smart Decanter

Instructions for Use

Product Presentation. C-series Rack Ovens

User Guide WINE CELLAR. Contents I GB F. Installation, 2 Location and power connection Technical information D E P

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

A IMPORTANT SAFEGUARDS

Baby Belling 321R. Installation and User Instructions

#COFFEEXPERIENCES COFFEE PERFECTION

Getting to Know Your Bananza

Powder Booths GLOBAL FINISHING SOLUTIONS GLOBALFINISHING.COM GLOBAL FINISHING SOLUTIONS

PARTS CATALOG ESPRESSO EP SYSTEM

1.5 L Slow Cooker 7644 Instructions for Use

A N F I M Srl. Caimano: Timer / Automatico / Manuale Super Caimano: Timer / Automatico Caimano SPecial 450: Timer / Automatico

SF4102MCS. linea. 60cm Dark Silver Linea Compact Combination Microwave Oven. Aesthetics Large LCD display 2 Illuminated control knobs Linea design

CAIMANO SPECIAL450 BARISTA

Burr Grinder. Automatic burr grinder with 17-position grind selector. Instruction Booklet EM0430

Operating instructions

QUALITY MILK FROTHER INSTRUCTION MANUAL MODEL NO. MMF005

ENZX. EBARA Submersible Slurry Pump. Contents Project: Model: Chk d: Date:

IMPORTANT SAFEGUARDS. 3. To protect against fire, electric shock and injury to persons do not immerse cord, plug or unit in water or other liquid.

SF4750VCAO. Functions. Versions. cortina. Main Oven Plus Main Oven

Instructions for use EEB and installation instructions FC1

AG/77 roller garage doors

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

Stainless Steel Milk Frother N3 User Manual

TEA CATER USER MANUAL. UM_EN Part No.:

DISCONTINUED VERSION The information in this manual is no longer current. Espresso/Cappuccino OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION

ATTIAS OVEN CORPORATION (COMMERCIAL BBQ ROTISSERIES)

PROGRAMMABLE COFFEE MAKER

TYPE AESTHETICS CONTROLS PROGRAMS / FUNCTIONS OPTIONS TECHNICAL FEATURES

Product Family: Oven Category: 60cm

AMÉRICA 90 ELÉCTRICO D

CHOCOLINO CAFÉLINO USER MANUAL UM_EN. Part No.: _01

NEVA DUO NEVA BEAN TO CUP NEVA 4 NEVA 3. Neva. Beverage Systems By Coffetek

ELECTRIC DOUBLE OVEN. User Manual. Model Numbers: DC60W DC60SS

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

Electric Two-Speed Drink Mixer

5KCG0702 W A_Final.indd 1 8/4/15 8:35 AM

5KEK1522 W A_01_EN.indd 1 11/16/12 1:22 PM

User manual COFFEE QUEEN. Tower 10 litre for wall mounting. Your retail dealer. U / GB Rev

Instruction Manual Coffee Grinder. Kaffeemühle / Coffee grinder CM 70 Serie

ITALFORNI. Pizza ovens. Spare parts for: Suitable for:

MODELS SHOWN: BICM24CS BUILT-IN COFFEE MACHINE AND WDC30JP WARMING DRAWER

Operating Instructions

Optimal solutions for your success.

A2-8 COOKER, 100X60 CM, OPERA, STAINLESS STEEL, GAS HOBS,ENERGY RATING AB EAN13: HOBS:

18-Bottle Dual Zone Slimline Edition Touchscreen Refrigerator

User Guide TEA CATER. Your Dealer. U / EN Rev

USER MANUAL TECHNICAL DATA

#COFFEEXPERIENCES COFFEE PERFECTION

Read the instructions, keep them safe, pass them on if you pass the appliance on. Remove all packaging before use.

blue 1 group 2 groups

10,000 prize draw. instructions. EXTRA year guarantee FREE rewards gallery. Register online now!

IMPORTANT INSTRUCTIONS MODE D EMPLOI IMPORTANT INSTRUCIONES IMPORTANTES ISTRUZIONI IMPORTANTI

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MMCX CONNECTORS

12 Bottle Dual Zone. Touchscreen INSTRUCTION MANUAL

288 MODEL BICM24CS SHOWN WITH WD30EP WARMING DRAWER

TYPE AESTHETICS CONTROLS PROGRAMS / FUNCTIONS OPTIONS TECHNICAL FEATURES

Special Lucalox. GE Lighting DATA SHEET. Description

SC45MC2. Functions. linea. 60cm "Linea" Compact Combination Microwave Oven, St/steel

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with EN certified safety function (spring down)

Nominal Lumen [lm] Rated Lumen [lm] Product Code

TR93IBL New product. Victoria. 90cm "Victoria" Traditional 3 cavity Cooker with Induction hob, Black enamel finish Energy rating AB

NEXUS RANGE. Nexus. The Nexus Range. By Coffetek

PrevaLED Bar G3. Dimension (l x w x h) 280 mm x 55 mm x 5 mm 560 mm x 55 mm x 5 mm

Time-setting options: Delay start and automatic end cooking

Operating instructions and service manual. Roller Grill GL-R series

10,000 prize draw. instructions. EXTRA year guarantee FREE rewards gallery. Register online now!

In-store baking oven HELIOS. Traditional baking on a stone slab

INSTRUCTION MANUAL FOR BUILT-IN OVENS

Chicken Rotisserie. Model LM-8A LM-12A LM-8M LM-12M Instruction Manual

... A Vital Part of Connection World CMPTER. Cable Connectors Receptacles With Solder End Protective Caps N CONNECTORS

User Manual. Stainless Steel Coffee Urn. Models: 177CU30 11/2018. Please read and keep these instructions. Indoor use only.

Any questions? Contact us at Telephone:

CPF48UGMYW New product

alfresco enjoy the experience

ORIGINAL LINE A USER MANUAL

Operating Instructions

NEVA DUO NEVA 3. Neva. Beverage Systems. By Coffetek

Operating Instructions VTA6S

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

SF4140MC. SMEG S.p.A. Via Leonardo da Vinci, Guastalla (RE) Tel Functions. Versions. linea. Main Oven Plus Main Oven

Coffeemaker User's manual

Southern Pride is proud to be represented by a network of specialized Distributors, dedicated to making

Operating Instructions DK15

SF140E. SMEG S.p.A. Via Leonardo da Vinci, Guastalla (RE) Tel Functions. linea. Main Oven Plus Main Oven

Installation Instructions Built-In Coffee Maker

G F I M J K L B C D E S O T H Q P U N R D 4

User Manual. Stainless Steel Coffee Urns. Models: 177CU30, 177CU55, 177CU110 04/2018. Please read and keep these instructions. Indoor use only.

Coffee Maker EC330 Please retain these instructions for future reference

Transcription:

6 Albany Plus www.mkelectric.co.uk Available in both matt chrome and satin brass finishes, Albany Plus brings stylish yet robust good looks to both contemporary and classical interiors. Manufactured from the finest materials and coated with a special heat-cured powder lacquer finish ensures that these accessories maintain their discerning appearance for years to come. In addition to good looks, with Albany Plus comes unrivalled safety. Utilising MK s unique 3-pin operated safety shutter, that prevents misuse and unsafe access to live circuitry, Albany Plus offers the user the peace of mind and comfort that they have the safest range of wiring devices available installed in their surroundings. Available in both matt chrome and satin brass finishes Providing a range of products that complement the décor of the finest modern and traditional interiors Pre-treated, heat-cured powder lacquer finish Ensures that the range is durable, tarnish resistant and maintains its stylish and understated appearance for many years and eliminates the need for a gasket Total safety Unique 3-pin operated child resistant shutter system, which is designed to inhibit access to the electricity supply, unless all 3 pins of a standard British 3 Amp plug are in position Comprehensive range of sockets, switches and ancillary products Whatever the application, the Albany Plus range has a wiring device to suit

Albany Plus 7 TECHNICAL HOTLINE +44 (0)268 63720 DOUBLE POLE SWITCHING 3 AMP SOCKET AVAILABLE INDICATORS MATCHING SCREWS STYLISH CURVED DESIGN WITH WHITE INSERTS Blends unobtrusively into the environment Terminal screws are backed out and captive. Terminals are upwards facing to make installation easier. Funnel entrance to terminals. Clear terminal markings for easy identification. UNIQUE 3-PIN CHILD RESISTANT SHUTTER SYSTEM Designed to inhibit access to the electricity supply, unless all 3 pins of a standard British 3 Amp plug are in position Satin Brass finish has subtle good looks to suit classic interiors. PRE-TREATED HEAT-CURED POWDER LACQUER FINISH Ensures that the range is durable and tarnish resistant and eliminates the requirement for a gasket Stylish Satin Chrome finish compliments modern interior design.

8 Albany Plus www.mkelectric.co.uk Switchsocket Outlets WITH OUTBOARD 3 AMP ROCKERS 3 AMP NON STANDARD 3 AMP FILTERED 3 AMP K298 MCO K248 MCO K2947 MCO K28 MCO K2826 MCO K298 SAB K248 SAB K2947 SAB K28 SAB K800 WHI K2948 MCO K2448 MCO K2947 D6 MCO K29 MCO K2948 SAB K2448 SAB K2947 CE SAB K29 SAB K298 MCO 0 K298 SAB 0 GANG DP DUAL EARTH TERMINALS K298D6MCO 0 GANG DP WITH RED ROCKER DUAL EARTH TERMINALS K2948 MCO 0 K2948 SAB K2948D6MCO WITH RED ROCKERS 2mm GANG: 86 ZIC 2 GANG: 862 ZIC 3mm (for extra wiring space) GANG: 866 ZIC 2 GANG: 886 ZIC SURFACE WITH KNOCKOUTS GANG: K899 ALM 2 GANG: K897 ALM SURFACE WITHOUT KNOCKOUTS GANG: K829 ALM 2 GANG: K830 ALM GANG: 86 x 86mm 2 GANG: 86 x 46mm GANG: 60.3mm 2 GANG: 20.6mm BS.363 Pt. 2: 99 K248 MCO K248 SAB GANG DP DUAL EARTH TERMINALS K2448 MCO K2448 SAB S High Integrity Earthing K298, K248, K2947 Fitted with two earth terminals to provide a double earth facility for use when installations are to comply with Section 607 of BS.767, IEE Wiring Regulations Double pole switching All switchsockets have double pole switching (neutral makes first, breaks last). 0 K2947 MCO 0 K2947 SAB WITH OUTBOARD ROCKERS AND DUAL EARTH TERMINALS K2947D6MCO WITH OUTBOARD RED ROCKERS AND DUAL EARTH TERMINALS K2947CEMCO K2947CESAB WITH OUTBOARD ROCKERS AND CLEAN EARTH FACILITY K2947 CE MCO K2947 CE SAB This product is provided with facilities for clean earth connection. BS.363 Pt.2: 99 where relevant K28 MCO K28 SAB GANG DP WITH CLEAN EARTH FACILITY K29 MCO K29 SAB WITH CLEAN EARTH FACILITY K29D6MCO WITH RED ROCKERS AND CLEAN EARTH FACILITY K28, K29, These products are provided with facilities for clean earth connection and are suitable for non standard plugs with T shaped earth pin. See page 70. BS.363 Pt.2: 99 where relevant K2826 MCO SPIKE AND RFI K800 WHI REPLACEMENT FILTER SOCKET MOUNTING BOX 866 ZIC Provides two way filtering to reduce voltage spikes and radio frequency interference. Protected by thermal cut out. Fitted with two earth terminals to provide a double earth facility for use when installations are to comply with Section 607 of BS.767, IEE Wiring Regulations Maximum total load 3 amps 86 x 46 x 39mm 20.6mm BS.733: 99

Albany Plus 9 TECHNICAL HOTLINE +44 (0)268 63720 Switchsocket Outlets Socket Outlets (NON UK) RCD PROTECTED 3 AMP ROUND PIN 3 AMP AMP 27V 6 AMP MODULAR FORMAT K60 MCO K288 MCO K732 MCO K226 MCO K82 MCO / K38 WHI K630 SAB K288 SAB K732 SAB K226 SAB K82 SAB / K38 WHI K630 MCO K2883 MCO K733 MCO K2262 MCO K343 MCO / K490 WHI K6304 MCO K2883 SAB K733 SAB K2262 SAB K343 SAB / K490 WHI K60 MCO K60 SAB GANG 0mA RATED TRIPPING CURRENT ACTIVE CONTROL CIRCUIT K630 MCO K630 SAB GANG 30mA RATED TRIPPING CURRENT ACTIVE CONTROL CIRCUIT K6304 MCO K6304 SAB GANG 30mA RATED TRIPPING CURRENT PASSIVE CONTROL CIRCUIT : 886 ZIC Boxes must have a minimum depth of 3mm SURFACE K897 ALM K830 ALM Earth pin operated shutter. It is important to ensure that the correct control circuit, active or passive, is selected for each application, see page 229 for definitions. These products are pulsating d.c. and a.c. fault current sensitive. Only suitable for supply voltage of 240V a.c., 0Hz. 86 x 46mm 20.6mm BS.7288: 990 K288 MCO K288 SAB GANG DP AMP SHUTTERED K2883 MCO K2883 SAB GANG DP AMP SHUTTERED 2mm: 86 ZIC 3mm: (for extra wiring space) 866 ZIC SURFACE K899 ALM K829 ALM 86 x 86mm 60.3mm BS.46: 90 K732 MCO K732 SAB GANG K733 MCO K733 SAB 2 GANG WITH DUAL EARTH TERMINALS High Integrity Earthing K733 is provided with dual earth terminals for use when installations are to comply with Section 607 of BS.767, IEE Wiring Regulations 2mm GANG: 86 ZIC 2 GANG: 862 ZIC 3mm (for extra wiring space) GANG: 866 ZIC 2 GANG: 886 ZIC SURFACE GANG: K899 ALM 2 GANG: K897 ALM GANG: K829 ALM 2 GANG: K830 ALM GANG: 86 x 86mm 2 GANG: 86 x 46mm GANG: 60.3mm 2 GANG: 20.6mm BS.363: Pt 2: 99 K226 MCO K226 SAB GANG SHUTTERED K2262 MCO K2262 SAB 2 GANG SHUTTERED 2mm GANG: 86 ZIC 2 GANG: 862 ZIC 3mm (for extra wiring space) GANG: 866 ZIC 2 GANG: 886 ZIC SURFACE GANG: K899 ALM 2 GANG: K897 ALM GANG: K829 ALM 2 GANG: K830 ALM GANG: 86 x 86mm 2 GANG: 86 x 46mm GANG: 60.3mm 2 GANG: 20.6mm SSA 444:98 K82 MCO or K82 SAB with K83 WHI 0 GANG 6 AMP 20V SHUTTERED GERMAN TYPE (2P+E) SOCKET K84 MCO or K84 SAB with 2 x K83 0 2 GANG 6 AMP 20V SHUTTERED GERMAN TYPE (2P+E) SOCKETS K343 MCO or K343 SAB 0 with K490 WHI & K370 0 GANG 6 AMP 2/20V SHUTTERED UNIVERSAL TYPE SOCKET : 3mm (2P+E SOCKETS) GANG: 866 ZIC 2 GANG: 886 ZIC* SURFACE GANG: K899 ALM 2 GANG: K897 ALM* GANG: K829 ALM 2 GANG: K830 ALM* GANG: 86 x 86mm 2 GANG: 86 x 46mm* The universal socket does not incorporate an earth contact. Therefore, appliances needing earth connection (class equipment) must NOT be used with this socket. The socket is intended for use with BS, USA and CEE standard plugs. GANG: 86 x 86mm IEC 60884-: 2002 BS.733:99 (Universal) * German type only

20 Albany Plus www.mkelectric.co.uk Non Standard Socket Outlets Floor Mounted Socket Outlets Connection Units SWITCHED 3 AMP 3 AMP AMP NON UK FUSED K239 MCO K93 MCO K96 SAB K97 D6 MCO 74 MCO 70 MCO K239 SAB K94 MCO K96 D6 MCO K97 KO MCO K94 SAB K97 MCO K973 KO MCO 74 SAB 70 SAB K96 MCO K97 SAB K239 MCO K239 SAB 2 GANG WITH CLEAN EARTH FACILITY 2mm: 862 ZIC 3mm: 886 ZIC (for extra wiring space) K897 ALM K830 ALM K239/749 These products are provided with facilities for clean earth connections and are suitable for non-standard plugs with T shaped earth pins. For compatible non standard plugs see page 70. 86 x 46mm 20.6mm BS.363 Pt. 2: 99 where relevant 740 MCO 0 740 SAB 0 GANG SWITCHSOCKET WITH SPRING LOADED HINGED COVER PLATE 74 MCO 0 74 SAB 0 GANG SOCKET WITH SPRING LOADED HINGED COVER PLATE 742 MCO 742 SAB 2 GANG SOCKET WITH SPRING LOADED HINGED COVER PLATE 749 MCO 0 GANG NON STANDARD SOCKET WITH SPRING LOADED HINGED COVER PLATE : GANG: 866 ZIC 2 GANG: 886 ZIC Boxes must have a minimum depth of 3mm Rotary operated shutter. GANG: 02 x 86mm 2 GANG: 02 x 46mm GANG: 60.3mm 2 GANG: 20.6mm BS.363: Pt 2: 99 70 MCO 70 SAB 0 0 FLOOR MOUNTED A 27V SOCKET WITH SPRING LOADED HINGED COVER PLATE 2mm GANG: 86 ZIC 3mm (for extra wiring space) GANG: 866 ZIC SURFACE GANG: K899 ALM GANG: K829 ALM GANG: 86 x 86mm GANG: 60.3mm SSA 444:98 K93 MCO K93 SAB WITH FLEX OUTLET K94 MCO 0 K94 SAB K94KOMCO WITH TAMPERPROOF FUSE CARRIER SCREW : 866 ZIC SURFACE (MCO) K899 ALM K829 ALM All connection units are fitted with a 3amp fuse (to BS362) TERMINAL CAPACITY 2 x 6mm 2 stranded (max) 86 x 86mm 60.3mm BS. 363 Pt 4: 99 K96 MCO 0 K97D6MCO K96 SAB WITH FLEX OUTLET, NEON AND RED ROCKER K96KOSAB K97KOMCO WITH TAMPERPROOF FUSE CARRIER SCREW WITH FLEX OUTLET, NEON AND TAMPERPROOF K96D6MCO FUSE AND RED ROCKER CARRIER SCREW K973KOMCO DP WITH SECRET KEY OPERATED SWITCH, NEON AND TAMPERPROOF FUSE CARRIER SCREW K97 MCO K97 SAB WITH FLEX OUTLET AND NEON

Albany Plus 2 TECHNICAL HOTLINE +44 (0)268 63720 Connection Units DP Switches Cooker Switches UNSWITCHED FUSED 20 AMP 32 AMP 4 AMP 4 AMP DP MAIN SWITCH AND 3 AMP SWITCH SOCKET OUTLET WITH NEONS K948 MCO K23 MCO K233 D6 MCO K06 MCO K26 MCO K236 MCO K948 SAB K233 MCO K20 MCO K06 SAB K26 SAB K98 MCO K233 SAB K20 SAB K236 SAB K978 SAB K948 MCO K948 SAB K948KOMCO WITH TAMPERPROOF FUSE CARRIER SCREW K98 MCO K23 MCO K233 MCO K233 SAB K233D6MCO AND RED ROCKER K20 MCO K20 SAB WITH FLEX OUTLET AND NEON K06 MCO K06 SAB K236 MCO K236 SAB K26 MCO K26 SAB K978 MCO K978 SAB WITH FLEX OUTLET AND NEON : 866 ZIC K899 ALM K829 ALM All connection units are fitted with a 3amp fuse (to BS362) TERMINAL CAPACITY 2 x 6mm 2 stranded (max) 86 x 86mm 60.3mm BS. 363 Pt 4: 99 : 866 ZIC SURFACE (MCO) K899 ALM K829 ALM TERMINAL CAPACITY 2 x 6mm 2 stranded (max) 86 x 86mm 60.3mm BS EN 60669-: 2000 DP Switches are not recommended for switching large banks of PCs : 866 ZIC (6mm 2 conductors) 877 ZIC (0mm 2 conductors) K899 ALM K829 ALM 86 x 86mm 60.3mm BS EN 60669-: 2000 : 886 ZIC (6mm 2 conductors) 878 ZIC (0mm 2 conductors) SURFACE (MCO) WITH KNOCKOUTS K897 ALM WITHOUT KNOCKOUTS K830 ALM 86 x 46mm 20.6mm BS.3676 Pt.: 989 : 886 ZIC (Up to 6mm 2 conductor) 878 ZIC (Up to 0mm 2 conductor) Rotary operated shutter. 86 x 46mm 20.6mm BS.477: 992

22 Albany Plus www.mkelectric.co.uk Triple Pole & Neutral Switch Shaver Supply Units Flex Outlets (NON UK) Plateswitches 3 Pole Fan Isolator 0 AMP 32 AMP 0 AMP WIDE ROCKER 0 AMP K2240 MCO K467 MCO K476 MCO K4860 MCO K4 MCO K703 MCO K2240 SAB K467 SAB K476 SAB K4860 SAB K4672 MCO K4762 MCO K488 K707 SAB K4673 SAB K4762 SAB K4 MCO K703 MCO K703 SAB DUAL VOLTAGE /230V OUTPUT (220/240V 0HZ INPUT) K707 MCO K707 SAB DUAL VOLTAGE /230V OUTPUT (20/30V 0HZ/60HZ INPUT) (NON UK) K2240 MCO K2240 SAB FLEX OUTLET K467 MCO K467 SAB GANG SP TWO-WAY K4672 MCO K4672 SAB 2 GANG SP TWO-WAY K4673 MCO K4673 SAB 3 GANG SP TWO-WAY K476 MCO K476 SAB GANG SP TWO-WAY WIDE ROCKER K4762 MCO K4762 SAB 2 GANG SP TWO-WAY WIDE ROCKERS K4860 MCO WITHOUT SWITCHLOCK K4860 SAB WITHOUT SWITCHLOCK K488 SWITCHLOCK FOR FAN ISOLATOR 0 MOUNTING BOX : 878 ZIC This product is rated at 440 volts with a motor load rating of up to 2kW - 6 HP at 4V 3 phase. It has a utilisation category of AC22A switching of mixed resistive and inductive loads including moderate overloads for a continuous duty of 32 amps. Making capacity is 2000 amps peak. TERMINAL CAPACITY: 6mm 2 conductors. 46 x 86mm BS EN 60947-3: 992 : 878 ZIC This design incorporates a double wound isolating transformer rated 20VA at 230 or volts and meets BS.33: 996 making it safe for use in bathrooms. Insertion of a shaver plug automatically switches on by energising the primary side of the isolating transformer removal automatically switches off. The transformer is protected against overload by an automatic solid state overload device with automatic resetting. 46 x 86mm 20.6mm. BS EN 68-2-: 998 : 866 ZIC SURFACE (MCO) K899 ALM K829 ALM Cable diameter: Minimum 4mm Maximum 4.mm gang: 86 x 86mm gang: 60.3mm : 399 ZIC K899 ALM K829 ALM These switches do not have to be derated when used with fluorescent or inductive loads. Switches can be wired as either one-way or two-way. 86 x 86mm 60.3mm BS EN 60669-:2000 If an intermediate switch is required, a modular (Grid Plus) version is available. Order K343 MCO/SAB grid plate, K370 grid frame and K4893 WHI 20A intermediate switch. : 399 ZIC SURFACE: K260 WHI For local isolation of fans with or without timers for repair or routine maintenance. 86 x 86mm 60.3mm BS EN. 60947-3: 992

Albany Plus 23 TECHNICAL HOTLINE +44 (0)268 63720 Standard Dimmer Switches Intelligent Dimmer Switches Dimmer Switches (NON UK) Blank Plates 230V a.c. 0Hz 230V a.c. 0Hz TUNGSTEN FILAMENT TUNGSTEN FILAMENT AND LOW VOLTAGE 200-240V a.c. 0Hz or 60Hz 27V a.c. 60Hz K32 MCO K36 MCO LV K63 MCO K73 MCO K3330 MCO K33 SAB K32 SAB LV K64 SAB K73 SAB K3329 SAB K34 MCO K MCO LV K66 MCO K74 MCO K SAB K2 SAB LV K66 SAB K76 SAB K32 MCO K32 SAB GANG TWO WAY DOUBLE 40W, 20W max for each dimmer K33 MCO K33 SAB 2 GANG TWO WAY TRIPLE 40W min, 20W max for each dimmer K34 MCO K34 SAB GANG TWO WAY SINGLE 40W min, 20W max K MCO K SAB GANG TWO WAY SINGLE 60W min, 00W max K2 MCO K2 SAB 2 GANG TWO WAY DOUBLE 60W min, 40W max for each dimmer Conforming to the latest standards BS EN 60669-2- and BS EN 0, they are overload protected and are suitable for use with tungsten filament lamps only. Two way dimmers use push on/push off switches. They are not suitable for use with fluorescent loads or with electronic or with wire-wound transformers in low voltage lighting systems K36 MCO LV K36 SAB LV GANG TWO WAY SINGLE 40W/VA min, 300W/240VA max K32 MCO LV K32 SAB LV GANG TWO WAY DOUBLE 40W/VA min, 300W/240VA max for each dimmer K MCO LV K SAB LV GANG TWO WAY SINGLE 60W/VA min, 00W/400VA max K2 MCO LV K2 SAB LV 2 GANG TWO WAY DOUBLE 60W/VA min, 40W/360VA max for each dimmer Conforming to the latest standards BS EN 60669-2- and BS EN 0, they use state of the art micro controller based circuitry to provide soft start and overload protection. The soft start feature helps in greatly prolonging the life of tungsten, normal or halogen lamps. Suitable for use with good quality electronic or wire wound transformers. Can also be used with good quality mains voltage halogen lamps incorporating GU0 bases. Please check with lamp manufacturer to determine suitability. Not suitable for use with fluorescent loads. K3 MCO K3 SAB GANG ONE WAY 40 20W 0Hz K4 MCO K4 SAB GANG SINGLE ONE WAY 7 00W 0Hz K6 MCO K6 SAB GANG SINGLE TWO WAY 00 000W 0Hz K63 MCO K63 SAB GANG SINGLE ONE WAY 40 20W 60Hz K64 MCO K64 SAB GANG SINGLE ONE WAY 7 00W 60Hz K66 MCO K66 SAB GANG SINGLE TWO WAY 00 000W 60Hz K73 MCO K73 SAB GANG SINGLE ONE WAY 40 20W FOR DIMMERS : gang: 86 ZIC 2mm deep min 2 gang: 862 ZIC 2mm deep min 866 ZIC: 3mm min for K32 MCO LV K32 SAB LV gang: 86 x 86mm 2 gang: 86 x 46mm gang: 60.3mm 2 gang: 20.6mm K74 MCO K74 SAB GANG SINGLE TWO WAY 60 40W K76 MCO K76 SAB 2 GANG SINGLE TWO WAY 90 60W Conforming to relevant parts of BS, these dimmers are suitable for use with tungsten filament lamps only. NOTE: Dimmer switches specified to work at 0Hz are not really suitable for use at 60Hz and vice versa. The one way dimmers use rotary on/off switches, while the two way dimmers use push on/push off switches. These dimmer switches are not suitable for use with fluorescent loads or with electronic or with wirewound transformers in low voltage lighting systems K3330 MCO K3330 SAB GANG K3329 MCO K3329 SAB 2 GANG : GANG:866 ZIC 2 GANG:886 ZIC GANG:K899 ALM 2 GANG:K897 ALM GANG:K829 ALM 2 GANG:K830 ALM gang: 86 x 86mm 2 gang: 86 x 46mm gang: 60.3mm 0 0

24 Albany Plus www.mkelectric.co.uk TV/FM Coaxial Socket Outlets Satellite Socket Outlets Telephone Outlets (NON UK) Euro, LJU6C and MK Modular Data Frontplates Grid Plus Frontplates 3 PIN K380 MCO K38 MCO K330 MCO K82 MCO K3433 MCO K380 SAB K38 SAB K330 SAB K72 SAB K3436 SAB K38 MCO K382 SAB K380 MCO K380 SAB SINGLE OUTLET (NON ISOLATED) K38 MCO K38 SAB SINGLE OUTLET (ISOLATED) K382 MCO K382 SAB TWIN OUTLET WITH TV/FM DIPLEXER (ISOLATED) : 86 ZIC K899 ALM K829 ALM K380 Single outlet for connection to a single TV or FM co-axial aerial lead. K38, K382 Provides safety isolation rated at 2000Va.c. between aerial lead and socket. Single outlet for connection to a single TV or FM co-axial aerial lead. Twin outlet with TV/FM diplexer for connection to single coaxial aerial lead with combined TV & FM signals. Suitable for UHF TV and VHF FM radio. K38 MCO K38 SAB SINGLE OUTLET F TYPE SATELLITE SOCKET IEC 69-2: 96 86 x 86mm 60.3mm BS. 733: 99 where applicable Fully screened modular TV/Satellite outlets are available to fit Euro frontplates. See page 3 for details. K330 MCO K330 SAB 3 PIN SOCKET WITH TELEPHONE SYMBOL SINGLE OUTLET Accepts standard BS.646 2 amp 2 pin + earth plug where 2 pins are used for telephone circuits and the earth pin is used to ensure correct polarity. 86 x 86mm 60.3mm BS. 733: 99 where applicable K39 MCO K394 SAB EURO K82 MCO K82 SAB 2 MODULE K84 MCO K84 SAB 4 MODULE LJU6C K72 MCO K72 SAB 2 MODULE MK MODULAR K39 MCO K39 SAB MODULE K392 MCO K392 SAB 2 MODULE K393 MCO K393 SAB 3 MODULE K394 MCO K394 SAB 4 MODULE For a complete selection of Euro, LJU6C and MK Modular Data modules and more information see 0 0 0 0 pages 64-6 (MK Modular), 30-32 and 64-6 (Euro / LJU6C) & 2 module: 86 x 86mm 3 & 4 module: 86 x 46mm BS.733: 99 Note: LJU6C and Euro Data Frontplates: no grid required, modules just clip into place. MK Modular require appropriate grid. K343 MCO K343 SAB MODULE K3432 MCO K3432 SAB 2 MODULE K3433 MCO K3433 SAB 3 MODULE K3434 MCO K3434 SAB 4 MODULE K3436 MCO K3436 SAB 6 MODULE K3438 MCO K3438 SAB 8 MODULE K3439 MCO K3439 SAB 9 MODULE K3442 MCO K3442 SAB 2 MODULE K3448 MCO K3448 SAB 8 MODULE K344 MCO K344 SAB 24 MODULE K340 MCO K340 SAB ARCHITRAVE MODULE 0 0 0 0 0 0 For a complete selection of Grid Plus switch modules see pages 49 3 Architrave: 8 x 38mm & 2 module: 86 x 86mm 3 & 4 module: 86 x 46mm 6 & 8 module:46 x 46mm 9 & 2 module: 206 x 46mm 8 module: 206 x 206mm 24 module: 206 x 267mm BS.733: 99

Case Study 2 TECHNICAL HOTLINE +44 (0)268 63720 Cellular Operations, Swindon In the busy telemarketing environment, employees can easily become tired and irritable. Employers are forever looking for ways of improving this. Changing the environment in which employees work is a highly effective means. This has been successfully achieved by Cellular Operations plc UK, through the creation of an innovative structure. The Cellular Operations HQ Building is based in Swindon and has been designed by Richard Hywel Evans, with MK products specified. The buildings shape is not only a design feature, but it possesses a practical purpose within its environment. The design allows in streams of natural daylight, and the adjoining lake also functions as the key element in a simple ventilation system. The office has been celebrated as the happiest work place in Britain and turnover has significantly increased since its creation. Architect Richard Hywel Evans Architecture and Design Ltd M&E Consultant Curona Design Contractor Tilbury Douglas Project Manager/Quantity Surveyor EC Harris