Correlation of the free amino nitrogen and nitrogen by O-phthaldialdehyde methods in the assay of beer

Similar documents
DR6000 in the Brewing Industry: Important Methods in Accordance with MEBAK and ASBC

PRIMARY AMINO NITROGEN (PAN) ASSAY PROCEDURE

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Application Note CL0311. Introduction

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

Setting up your fermentation

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

DEVELOPMENT OF A RAPID METHOD FOR THE ASSESSMENT OF PHENOLIC MATURITY IN BURGUNDY PINOT NOIR

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

Assessment of the CDR BeerLab Touch Analyser. March Report for: QuadraChem Laboratories Ltd. Campden BRI Group contracting company:

Beer bitterness and testing

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

Determination of Caffeine in Coffee Products According to DIN 20481

Validation Report: Total Sulfite Assay Kit (cat. no. K-TSULPH)

RESOLUTION OIV-OENO MONOGRAPH ON GLUTATHIONE

Validation Report: Free Sulfite Assay Kit (cat. no. K-FSULPH)

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

EXPERIMENT 6. Molecular Fluorescence Spectroscopy: Quinine Assay

Measuring tannins in grapes and red wine using the MCP (methyl cellulose precipitable tannin assay

Measuring Sulfur Dioxide: A Perennial Issue. Tom Collins Fosters Wine Estates Americas

Exploring Attenuation. Greg Doss Wyeast Laboratories Inc. NHC 2012

Petite Mutations and their Impact of Beer Flavours. Maria Josey and Alex Speers ICBD, Heriot Watt University IBD Asia Pacific Meeting March 2016

MALT & BACTERIAL BETA-GLUCANASE & CELLULASE

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

Professional Analytical Services Catalogue

Alcoholic Fermentation in Yeast A Bioengineering Design Challenge 1

HOW MUCH DYE IS IN DRINK?

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

FERMENTATION. By Jeff Louella

RIDASCREEN Gliadin. Validation Report. R-Biopharm AG. Art.No. R7001

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

JUICE CHEMICAL ANALYSIS: WHAT TO MEASURE AND WHY

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

EFFECT OF SOME TECHNOLOGICAL FACTORS ON THE CONTENT OF ACETALDEHYDE IN BEER

Sequential Separation of Lysozyme, Ovomucin, Ovotransferrin and Ovalbumin from Egg White

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Determination of Metals in Wort and Beer Samples using the Agilent 5110 ICP-OES

TECHNICAL INFORMATION SHEET: CALCIUM CHLORIDE FLAKE - LIQUOR TREATMENT

Use of Accelerated Solvent Extraction (ASE) with Centrifugal Evaporation to Automate Fat Determination in Chocolate

What s New? AlveoLab, SRC-CHOPIN, Mixolab 2. CHOPIN Technologies Geoffroy d Humières

RISK MANAGEMENT OF BEER FERMENTATION DIACETYL CONTROL

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Acidity and ph Analysis

Fact Sheet ANALYSIS. Measuring total anthocyanins (colour) in red grape berries. Scope. Equipment and apparatus

Higher Resolution Separation of Organic Acids and Common Inorganic Anions in Wine

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

Allergens in wine a specific detection of Casein, Egg and Lysozyme

Automation of AOAC for the Identification of FD&C Color Additives in Foods using Solid Phase Extraction

Evaluation of the Malting and Brewing Performance of the New Canadian Malting Barley Variety Norman

Passionate about malt for over 90 years. Meet your specific requirements

CMBTC 2017 Crop MALTING BARLEY QUALITY ASSESSMENT Preliminary Report

Institute of Brewing and Distilling

An Economic And Simple Purification Procedure For The Large-Scale Production Of Ovotransferrin From Egg White

RELATIONSHIPS BETWEEN THE SPEED OF FERMENTATION AND LEVELS OF FLAVOUR COMPOUNDS POST- FERMENTATION

Analysis of Beta-Carotene and Total Carotenoids from Pacific Sea Plasma (Spectrophotometric Method)

Malt Specifications for the Practical Brewer. Ashton Lewis Technical Sales Manager Central Midwest

Separation of Ovotransferrin and Ovomucoid from Chicken Egg White

2012 Crop CDC Kindersley Malting & Brewing Trials

COMPARATIVE EVALUATION OF CLARIFYING REAGENTS OCTAPOL AND LEAD SUB ACETATE FOR USE WITH MASSECUITES AND MOLASSES. Niconor Reece and Sydney Roman

Determination Of Saponin And Various Chemical Compounds In Camellia Sinensis And Genus Ilex.

PRESENCE OF YELLOW 6, AN ARTIFICIAL COLOUR ADDITIVE IN ORANGE JUICE

QUANTITATIVE ASSAY FOR OCHRATOXIN A IN COFFEE, COCOA, AND SPICES (96-well kit)

HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

Guidelines and Suggestions for Starting Maltsters

Pilot Malting and Brewing Trials with 2011 Crop CDC Meredith Barley

CORRELATIONS BETWEEN CUTICLE WAX AND OIL IN AVOCADOS

2012 Crop CDC Meredith Malting and Brewing Trials

Determination of Alcohol Content of Wine by Distillation followed by Density Determination by Hydrometry

Determination of natamycin in wines Résolution OIV-SCMA

WineScan All-in-one wine analysis including free and total SO2. Dedicated Analytical Solutions

Methanol (Resolution Oeno 377/2009, Revised by OIV-OENO 480/2014)

OBTAINING AND CHARACTERIZATION OF BEERS WITH CHERRIES

yeast-derived flavours

The Determination of Pesticides in Wine

Fast Analysis of Smoke Taint Compounds in Wine with an Agilent J&W DB-HeavyWax GC Column

Dr.Nibras Nazar. Microbial Biomass Production: Bakers yeast

2013 Crop AAC Synergy Pilot Malting and Brewing Trials

Solid Phase Micro Extraction of Flavor Compounds in Beer

High Sensitivity Quantitation Method of Dicyandiamide and Melamine in Milk Powders by Liquid Chromatography Tandem Mass Spectrometry

AppNote 13/2012. Automated Solid Phase Extraction (SPE)-LC-MS/MS Method for the Determination of Acrylamide in Brewed Coffee Samples KEYWORDS ABSTRACT

Virginie SOUBEYRAND**, Anne JULIEN**, and Jean-Marie SABLAYROLLES*

distinct category of "wines with controlled origin denomination" (DOC) was maintained and, in regard to the maturation degree of the grapes at

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

ENCAPSULATION OF BREWING YEAST IN ALGINATE/CHITOSAN MATRIX: COMPARATIVE STUDY OF BEER FERMENTATION WITH IMMOBILIZED AND FREE CELLS

powder and cocoa butter and various spices in the range of 1-20 ppb (µg/kg).

International Journal of Food and Bioscience

Buying Filberts On a Sample Basis

Application Note No. 193/2015

CHAPTER 8. Sample Laboratory Experiments

A Fast Method for Sugar Analysis of Instant Coffee Samples

Measuring Fluoride in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Glutomatic System. Measure Gluten Quantity and Quality. Gluten Index: AACC/No ICC/No. 155&158 Wet Gluten Content: ICC/No.

FED. TEST METHOD STD. 191A AND SHALL BE RETAINED UNTIL SUCH CHANGE NOTICE 3 TIME AS THE STANDARD IS REVISED. January 15, 1986

Volume NaOH ph ph/ Vol (ml)

F&N 453 Project Written Report. TITLE: Effect of wheat germ substituted for 10%, 20%, and 30% of all purpose flour by

15. Extraction: Isolation of Caffeine from Tea

! " # # $% 004/2009. SpeedExtractor E-916

Transcription:

APPLICATION NOTE 71798 Correlation of the free amino nitrogen and nitrogen by O-phthaldialdehyde methods in the assay of beer Authors Otama, Liisa, 1 Tikanoja, Sari, 1 Kane, Hilary, 2 Hartikainen, Sari, 1 Kaski, Leena, 1 and Suoniemi-Kähärä, Annu 1 1 Thermo Fisher Scientific, Vantaa Finland 2 Thermo Fisher Scientific, Hemel Hempstead, UK Keywords Discrete Analyzer, Photometric Analyzer, Gallery Analyzer, Fermentation, Beer, Wort, FAN, Free Amino Nitrogen Goal To demonstrate that the automated discrete analyzer method for analysis of free amino nitrogen (FAN) provides comparable results to traditional ninhydrin methods, while also allowing multiple automated tests to be performed on the same sample. Introduction In normal fermentation, the yeast Saccharomyces, converts sugar to ethanol and carbon dioxide. Yeast synthesizes the proteins required for healthy growth from amino acids that may be created from ammonia or by removal of the amino group from other alpha amino acids. The alpha amino acids available to yeast during fermentation are known as Free Amino Nitrogen (FAN). Levels of FAN in wort influence the formation of higher alcohols, specifically ethanol, which contributes to the flavor of beer and influences the flavor contribution other alcohols will make. Alcohols will be present at either excessively high or insufficiently low levels based on amounts of assimilable nitrogen available to the yeast from the wort. If levels are low, yeast growth is limited. If levels of nitrogen (N) are high, amino acids inhibit further synthesis increasing yeast growth and promoting higher alcohol formation. A FAN level of 140 mg/l for wort of 10 Plato (a measurement of the density of beer wort as a percent of extracted sucrose by weight) has generally been recommended to place the ratio of carbon to nitrogen in the range of favorable flavor compounds. The ninhydrin method estimates amino acids, ammonia, and the terminal nitrogen groups of peptides and proteins. The European Brewery Convention (EBC), MEBAK, and American Society of Brewing Chemists (ASBC) describe FAN measurement using the ninhydrin based assay.

The correlation between the Brewing Analytes Proficiency Testing Scheme (BAPS) beer samples measured according to the EBC FAN protocol and the Thermo Scientific Gallery system alpha-amino nitrogen by o-phthaldialdehyde (NOPA) method are examined. This rapid 2-reagent method was developed for a multipurpose discrete analyzer and the method is easily adapted for use with a manual spectrophotometer. A blank buffer eliminates possible sample color interference. The total analysis time for six samples and 60 test requests is approximately 45 minutes. Experimental Materials and methods Instrument The NOPA method was tested using a Thermo Scientific Gallery discrete analyzer. Similar results were obtained with the Thermo Scientific Gallery Plus discrete analyzer, Thermo Scientific Arena discrete analyzer, and Thermo Scientific Gallery Plus Beermaster discrete analyzer. Reagents A Thermo Scientific Gallery system reagent based on the alpha amino nitrogen by O-phthaldialdehyde (NOPA) method was used which provides ready-to-use non-hazardous reagents for 300 tests when performed using the automated discrete analyzer. Method principle Primary amino groups are derived by a reaction of o-phthaldialdehyde (OPA) and N-acetyl cysteine (NAC) to form isoindoles. In optimized conditions isoindoles form a chromogenic complex proportional to the concentration of alpha-amino nitrogen in the sample. The reaction is measured photometrically at a 340 nm wavelength using a side wavelength of 700 nm. Samples Six commercial BAPS reference samples were purchased from LGC Standards. Assigned values from the proficiency test average result from the analysis of samples according to the official EBC method in different laboratories. Beer and wort samples were analyzed for method comparison and performance studies. In an industry setting, 33 malt or malt extract samples were analyzed. In-house ninhydrin results were assigned as reference values. Malt samples were prepared as either an Institute of Brewing (IoB) or an EBC congress mash extract. Malt extract samples were diluted 1:4. Method calibration and quality control The method was calibrated with a NOPA standard from Thermo Fisher Scientific. The NOPA standard has an alpha-amino nitrogen concentration of mg/l. A glycine standard (Sigma-Aldrich, Cat # G7403) dissolved in water was used as a quality control sample. The standard stock was prepared by weighing 0.1085 g of pure glycine standard (C 2 H 5 NO 2, MW = 75.07 g/mol, purity 99%) into a volumetric flask and diluted to ml with deionized water. The solution has an alpha-amino nitrogen concentration of mg/l. QC samples of 20,, and 125 mg/l were diluted from stock with deionized water. Application for automation The automated Gallery discrete analyzer NOPA application consists of two reagents, an end-point measurement with a sample blank, and a linear calibration curve used for result calculation. Measuring ranges were tested from 20 to 300 mg/l with a secondary dilution of 1:3 at mg/l. First, µl of NOPA R1 reagent and 2 µl of sample are incubated for 120 seconds, then the reaction is blanked. After the addition of 20 µl of R2 reagent and 300 seconds of incubation, the reaction is measured at a wavelength of 340 nm. An additional side wavelength of 700 nm or 7 nm can be used to remove the effect of bubbles which may appear in cuvettes. The side wavelength is determined from the spectrum area where no reaction occurs. The method is performed at 37 C. Method calibration Results were calculated automatically by the discrete analyzer using a linear calibration curve. A calibrator solution with mg/l of alpha-amino nitrogen and deionized water was used to calibrate the test. In addition to the BAPS samples, 16 commercial beer samples and two wort samples were analyzed. Reference values were assigned by the ninhydrin method. For NOPA analysis, beer samples were degassed by shaking for 10 minutes. Wort samples were centrifuged. 2

Results and discussion Repeatability and reproducibility Repeatability was performed by analyzing BAPS samples with the Gallery discrete analyzer in three batches. Six different beer samples were analyzed with the number of measurements at n = 30. The test was calibrated prior to the analysis of each batch. The NOPA method showed excellent repeatability both within and between runs, and the typical within run coefficient of variation (CV %) was below 1.5%. Total repeatability of the measurement for the samples was between 2.2 and 3.2%. Repeatability results are shown in Table 1. Table 1. Method repeatability (n = 30). Sample 206-2L Sample 207-2L Sample 209-2L Assign value 92. Assign value 73.00 Assign value 30.00 Results (mg/l) N 30 N 30 N 30 Mean 98.63 Mean 74.07 Mean 29.83 z score 1.23 z score 0.21 z score -0.03 SD CV % SD CV % SD CV % Within run 1.14 1.2 0.79 1.1 0.75 2.5 Between run 1.86 1.9 1.85 2.5 0.21 0.7 Total 2.19 2.2 2.02 2.7 0.78 2.6 Sample 206-2B Sample 209-2B Sample 210-2L Assign value 52.74 Assign value 29.00 Assign value 114.17 Results (mg/l) N 30 N 30 N 30 Mean 54.36 Mean 29.10 Mean 126.49 z score 0.32 z score 0.02 z score 2.46 SD CV % SD CV % SD CV % Within run 0.44 0.8 0.32 1.1 1.52 1.2 Between run 1.66 3.1 0.62 2.1 3.24 2.6 Total 1.72 3.2 0.69 2.4 3.58 2.8 Calculating the Z-score Instructions from the BAPS were followed. A Z-score reports the statistical relationship to the mean of a group of scores. Interpretation of the Z-score calculation results are shown below: Z score Interpretation Z 2.00 Satisfactory result 2.00 < Z and < 3.00 Questionable result Z 3.00 Unsatisfactory result Linearity Method linearity was tested with pure chemicals dissolved in deionized water. The primary measurement was designed for a range of 20 mg/l and extended with a automatic secondary dilution (1:3) up to 300 mg/l. All linearity samples were measured as triplicates. An example of method linearity is shown in Figure 1. Result (mg/l) 3 300 y = 1.0078x - 2.38 r 2 = 0.9998 0 0 300 3 Theoretical (mg/l) Figure 1. Method linearity for 20 300 mg/l samples. 3

Method comparison to FAN For the method comparison study, 16 commercial beer samples and two wort samples were analyzed. Values used as a reference were assigned by the FAN ninhydrin method. For the NOPA analysis, beer samples were degassed by shaking for 10 minutes. Wort samples were also centrifuged. Recovery rates varied from 88 114%. For most samples, the recovery rates were 96 109% demonstrating excellent correlation between the two methods. Based on this preliminary study, this method shows good correlation to FAN (r 2 =0.99). A method comparison curve is shown in Figure 2. Malting industry comparison to FAN For a within-industry comparison, two malt extract samples and 31 malt samples (either IoB or congress mash extracts) were analyzed. NOPA results using the Gallery discrete analyzer were compared to in-house FAN ninhydrin results. The calibration was completed using a mg/l glycine standard. Results of the comparison demonstrate good correlation to the FAN method (r 2 =0.95) and are shown in Figure 3. y = 1.231x - 6.8424 r² = 0.97 NOPA Concentration (mg/l) 3 300 y = 1.0836x - 4.6005 r 2 = 0.9922 NOPA Concentration (mg/l) 0 0 20 40 60 80 120 140 160 180 FAN Concentration (mg/l) Figure 3. A comparison of the FAN and NOPA methods. 0 0 300 FAN Concentration (mg/l) Figure 2. Method comparison. Two wort samples have the highest NOPA concentration. Manual method The Gallery system reagent based on the alpha amino nitrogen by O-phthaldialdehyde (NOPA) method can also be performed manually using a spectrophotometer at 340 nm with a 1 cm cuvette path length. A baseline measurement is done against air or deionized water at 37 C. The method was designed as an end-point method with a reaction time of 5 minutes. The sample/ R1/R2 ratio is 1//10. Manual method linearity was in a range from 0 to mg/l. Conclusion All samples tested by the Gallery system reagent based on the alpha amino nitrogen by O-phthaldialdehyde (NOPA) method demonstrate result levels similar to samples tested according to the EBC FAN protocol for beer. Furthermore, no additional ammonia measurements are needed. The Gallery system reagent based on the alpha amino nitrogen by O-phthaldialdehyde (NOPA) method is an easy to use, robust method for the measurement of FAN in beer and wort. The advantage of using an automated discrete analyzer is its ability to measure multiple analytes like beta-glucan and SO 2 in addition to performing the NOPA measurement on the same sample. The results for all measured analytes can be reported together. Acknowledgements Thanks to Muntons plc for providing malt and malt extract samples and sharing their results. 4

References 1. Abernathy, D. Spedding, G. Starcher, B. Analysis of Protein and Total Usable Nitrogen in Beer and Wine Using a Microwell Ninhydrin Assay. J. Inst. Brew. 9, 115(2), 122 127. 2. Analytica-EBC, Method collection from European Brewery Convention, Free Amino Nitrogen in Beer by Spectrophotometry (IM) 9.10, 0. 3. ASBC Methods of Analysis, American Society of Brewing Chemists, Free Amino Nitrogen Wort-12, 9. 4. ASBC Methods of Analysis, American Society of Brewing Chemists, Free Amino Nitrogen Beer-31, 9. 1. Banforth, C. Scientific Principles of Malting and Brewing; American Society of Brewing Chemists: St. Paul, Minnesota, 6; p.126. Find out more at thermofisher.com/discreteanalysis 2018 Thermo Fisher Scientific Inc. All rights reserved. Sigma-Aldrich is a trademark of Sigma-Aldrich Co., LLC. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives. AN71798-EN 1218S