HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

Similar documents
HI Titratable Total Acidity Mini Titrator for Wine Analysis

Acidity and ph Analysis

INSTRUCTION MANUAL Mi456

INSTRUCTION MANUAL Mi455

HI FREE & TOTAL SULPHUR DIOXIDE MINITITRATOR for wine analysis

Measuring Fluoride in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Find out all you need to know about measuring SO 2. in wine making

Analytical Testing for Winemakers. Test crucial parameters in must and juice. hannainst.com

Beer bitterness and testing

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

Wine Analysis Products

FTIR Analyzer. Lyza 5000 Wine

Alcohol and Extract Meter for Beer, Wine, Cider, Spirits, Liqueurs, and Sake

CERTOMAT IS For controlled benchtop incubation

INSTRUCTION MANUAL Mi453 Reducing Sugars

Alcohol Meter for Wine. Alcolyzer Wine

PASSION FOR TECHNOLOGY LEGACY OF

Alcolyzer Plus Spirits

AREA: TECHNOLOGY CLOTHED BY ITALIAN DESIGN.

INSTRUCTION MANUAL Milwaukee Wine Lab Photometer Mi454 Tartaric Acid

INGREDIENT FEEDERS Add any ingredient to your ice cream. ...ice cream the way you like it. Operator-friendly, convenient fill height

T raditional C offee M achines

#COFFEEXPERIENCES COFFEE PERFECTION

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

OenoFoss Instant Quality Control made easy

S uper A utomatic C offee M achines

Saeco Idea Restyle Semiautomatic table top for mid to large offices and ho.re.ca. applications

Vinmetrica SC-100A User Manual

What s New? AlveoLab, SRC-CHOPIN, Mixolab 2. CHOPIN Technologies Geoffroy d Humières

LABORATORY INVESTIGATION

Brabender GmbH & Co. KG The leading supplier for food quality testing instruments

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

The fermentation of glucose can be described by the following equation: C6H12O6 2 CH3CH2OH + 2 CO2 + energy glucose ethanol carbon dioxide.

WineScan All-in-one wine analysis including free and total SO2. Dedicated Analytical Solutions

Copyright JnF Specialties, LLC. All rights reserved worldwide.

AWRI Refrigeration Demand Calculator

EBI 10 High Precision Wireless Data Loggers

VIN AU VERRE 8.0. For an efficient & well managed wine by the glass service! Solutions for displaying and serving wine

KARISMA. Machine Presentation

THE GR THER A AINF AINF A THER THE GR

F R E S H C U P. Single Serve Automatic Eject Pod System by:

iworx Sample Lab Experiment GB-4: Ecological Balance

Franke Coffee Systems Evolution Plus: even more choice at the touch of a button.

Pre-Selection Plus operating unit: pre-selection and beverage selection presented with great style!

Volume NaOH ph ph/ Vol (ml)

We have been manufacturing pumps. for over 60 years, and from the early. years we have especially focused on. the research and development of the

Validation Report: Free Sulfite Assay Kit (cat. no. K-FSULPH)

WE GRANTED YOUR FIRST WISH: THE BEST QUALITY IN A TOUCH

Vinmetrica SC-100A User Manual

#COFFEEXPERIENCES COFFEE PERFECTION

Nitron 2. Cold Draft. Cold Brew and Nitro Coffee - On Tap. bunn.com/nitron

Calibrate grill heat zones Monthly GR 1 M1

TRADITION MADE NEW. THE EVOLUTION.

In-store baking oven HELIOS. Traditional baking on a stone slab

PRODUCT SELECTION GUIDE

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

Networking. Optimisation. Control. WMF Coffee Machines. Digital Solutions 2017.

SuperSteam TM. Oven More than just a microwave

Assessment of the CDR BeerLab Touch Analyser. March Report for: QuadraChem Laboratories Ltd. Campden BRI Group contracting company:

HI COLOR & PHENOLS ISM for wine analysis

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

TURBOMIXERS AND PREMIXERS. VERTIMIX TURBOMIXER GTM SERIES TURBOMIXER GTM TANK-LESS SERIES TURBOMIXER GMG SERIES PREMIXER PCG SERIES

Operating the Rancilio Silvia after PID kit modification Version 1.1

For Beer with Character

Validation Report: Total Sulfite Assay Kit (cat. no. K-TSULPH)

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

enjoy the experience

For Beer with Character

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

EXACT MIXING EXACT MIXING. Leaders in Continuous Mixing solutions for over 25 years. BY READING BAKERY SYSTEMS

Product Presentation. C-series Rack Ovens

BAKED GOODS VARIETY OF APPLICATIONS

CERTOMAT IS For controlled benchtop incubation

HONEY. Food and Agriculture Organization of the United Nations

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

CHOPIN Technologies' solutions for measuring dough tenacity, extensibility, elasticity and baking strength

PECTINASE Product Code: P129

Environmental Monitoring for Optimized Production in Wineries

GIGA X7. Technical data. JURA standards. Variable brewing unit, from 5 g to 16 g. Intelligent Pre-Brew Aroma System (I.P.B.A.S. )

GENEVA RANGE. Geneva. The Geneva Range. By Coffetek

Franke Coffee Systems Evolution: The ultimate stage in coffeemaking competence.

Application Note No. 193/2015

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

Innovations for a better world. Ingredient Handling For bakeries and other food processing facilities

Machine No. 2, SV=104. Figure 1

New DISCOVER THE MAGIC OF PACOTIZING WITH PACOJET 2

Precise Control Benefits Beverage Producers Profitability

CERTOMAT S II Orbital benchtop shaker

Quality and variety. To each his own. To each the best. Macchiavalley keeps the quality of the up to 21 programmable. constantly on a high level.

Harvest Series 2017: Wine Analysis. Jasha Karasek. Winemaking Specialist Enartis USA

Gluten Index. Application & Method. Measure Gluten Quantity and Quality

LIFE COMES IN MANY FLAVORS

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

Artisan-made ice cream, just as you like it. And much, much more...

ION FORCE DNA EXTRACTOR FAST Cat. N. EXD001

TRADITION MADE NEW. THE EVOLUTION.

Liquids Handling in Bakeries.

Introduction to Measurement and Error Analysis: Measuring the Density of a Solution

NEVA DUO NEVA BEAN TO CUP NEVA 4 NEVA 3. Neva. Beverage Systems By Coffetek

Dough Master. Member of the

Transcription:

HI 84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis

Piston Driven Pump with Dynamic Dosing The HI 84533 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the amount of titrant dosed as the end point is approached for increased accuracy in end point detection. Piston Burette Piston burettes provide an exceptionally reliable titrant delivery. This highly accurate dosing method is attained by combining a pulse controlled step motor with a 5 ml polypropylene syringe. The rigid and stable body of our syringe allows for less frequent pump calibration. Users no longer have to account for the changing elasticity of tubing associated with peristaltic pumps. More About Dynamic Dosing With the integration of our piston burette, our titrator can adjust the volume and frequency of titrant dosed based on relative mv changes in the testing solution. This titrant delivery system is known as dynamic dosing, where titrant is delivered in larger doses at the start of the titration and smaller doses near the end point. These differences in dosing volume and frequency result in a faster titration without sacrificing accuracy. With larger doses in the beginning of the titration, the speed of the titration is increased, where smaller doses near the end point allow for more time for the titrant and analyte to react. Smaller doses also prevent the over titration of a sample and a more accurate determination of titrant volume used. ph Electrode The HI 84533 is supplied with the HI 1131B refillable, double junction, combination ph electrode. By design, the HI 1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for any general acid or base titration in the beverage or agricultural industry.

HI 84533 Mini Titrator for Wine & Fruit Juice Applications Piston Driven pump with Dynamic Dosing This piston driven dosing pump incorporates dynamic dosing to provide highly accurate, repeatable results. CAL CHECK CAL CHECK alerts users to potential problems during calibration such as contaminated buffers or dirty/broken electrodes. ph/mv M eter In addition to automatic titration, the HI 84533 can also be used as a ph/mv meter. Log-on-Demand Log data up to 400 samples (200 for titration; 200 for ph/mv). Graphic Mode/Exportable Data Displays in-depth data on titration, which can then be stored and exported to either a USB drive or PC using the USB connection. Automatic Stirrer Speed Control Maintains stirrer speed at approximately 600 rpm regardless of viscosity of solution. GLP Feature The HI 84533 includes a GLP Feature that allows users to view calibration data for the ph electrode and dosing pump. Easy to use interface User intuitive design with large keys and easy to navigate screens. ph Electrode The HI 84533 is supplied with the HI 1131B electrode. This versatile electrode can measure all types of fruit juices and wines.

Easy to Use, Fast and Affordable All-in-one Solution The HI 84533 is an easy to use, fast and affordable mini automatic titrator designed for the rapid and accurate determination of formol number in wines or fruit juices. This new generation of mini automatic titrator improves upon the titrant delivery system and measuring ranges for increased accuracy compared to previous models. This meter reflects Hanna s years of experience as a manufacturer of analytical instruments. The HI 84533 incorporates a precise piston dosing system which allows for a highly accurate determination of the amount of titrant used. It is also capable of dynamic dosing, making testing both faster and more accurate. A pump calibration performed with the supplied Hanna standard help assure the accuracy of the measurement. This mini titrator includes a user adjustable programmed analysis method designed for formol number analysis. It employs a powerful and effective algorithm to analyze the ph response to determine the exact ph end point, then uses this algorithm to perform the necessary calculations. This mini-titrator is also designed to be used as a benchtop ph/mv meter. As a ph meter, it has many features of a professional grade benchtop including automatic calibration up to 3 points with 4 available buffers, a 0.01 ph resolution, accuracy of +/- 0.01 ph, automatic temperature compensation and comprehensive GLP Data. The GLP data includes date, time, offset, slope, and buffers used for calibration. Accuracy is always ensured with Hanna s unique Cal-Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty / Broken, and overall probe condition as a percentage that is based on both the offset and slope characteristic of the electrode. The Cal-Check function not only ensures an accurate ph reading when the HI 84533 is used as a ph meter but also an accurate titration since the end point is determined by a set ph value. Why Formol Number is So Important The amino-acid content and other nitrogen compounds in fruit juices and wines are expressed as total assimilable nitrogen and is determined by the formol method using an acid-base titration. The formol number (also known as formol index) is a parameter used for evaluation of the quality of fruit juices and wines. In wines, the concentration of alpha amino acid in grapes change as a function of maturity and crop load (yield to vine size ratio). The concentration increases with fruit maturation and decreases with crop load. In the fermentation of wine, there is a minimum amount of amino acid and other nitrogen compounds (eg: 150-200 mg/l of yeast assimilable nitrogen) that has to be present in the must/juice. Too low of an amount will result in a stuck fermentation in which there is not enough nitrogen for the yeast to thrive. Because of the importance of nitrogen in fermentation, it is desirable to determine the nitrogen concentration before fermentation. In fruit juices, the formol nitrogen number is one of the basic parameters measured to determine quality. Depending on the type of fruit the number can increase or decrease with maturity. In orange and grapefruit juice, lower values are observed when the fruit is not suitably mature or there has been frost damage. In pineapple juice, a low number could be indicative of over-dilution with water or a disproportionate amount of the core was used. To determine the adulteration of fruit juices, the formol number along with the chromatography characterization of amino acids can be used. All-in-One Wine & Fruit Juice Titrator, ph Meter, Electrode and Magnetic Stirrer in one package

Features Setup Screens Tutorial and HELP Screens The LCD features an easy to use setup screen that allows the user to change measuring range, time, date, language and more. Accessing the tutorial menu provides helpful information during calibration and titration. Rear USB Outputs For PC connection and to export data to a USB drive 1 6 2 7 3 8 4 CAL CHECK Titration Curve Displayed On Screen CAL CHECK is a Hanna exclusive process for checking the condition of electrodes which helps keep measurements accurate. The HI 84533 offers real time graphing of the titration curve on the LCD. 9 5 Display 1) Current time and instrument mode information (ph meter or Titrator) 2) Procedural indicators 3) Stirrer speed 4) Instrument status 5) Virtual option keys GLP Log and Recall data The GLP feature records electrode and pump calibration data to help keep measurements accurate and reliable. The HI 84533 can log up to 400 samples (200 for titration results; 200 for mv/ph) and recall or export data to a USB stick or PC. 6) Stirrer and icon status During the instrument s operation a set of information are displayed on the LCD. Displayed icons: Stirrer on Procedure Warnings Adjustable Backlit LCD Users are warned if there is an error in procedures such as the use of a wrong buffer. The HI 84533 offers a backlit LCD with adjustable brightness levels. This ensures that the LCD is always easy to read. Pump running Stirrer is not working properly Wait for stable reading Parameter can be modified 7) Main reading information 8) ph temperature compensation mode (Manual or Automatic) 9) Temperature reading

Specifications HI 84533 - Formol Number Accessories Titrator Accuracy (@25ºC/77ºF) Sample Volume Method Principle Pump speed Stirring Speed Logging Data ph Meter Low : meq/l 2.14 to 28.57 as N meq% 0.21 to 2.85 as N mg/l 30.0 to 400.0 as N Low : 0.01 meq/l; 0.01 meq%; 0.1 mg/l High : 0.1 meq/l; 0.01 meq%; 1 mg/l 3 % of reading or ± 0.1 mg/l Low : 10 ml; High : 5 ml Acid-base titration Endpoint 8.20 ph (selectable from 8.0-8.30 ph) 10 ml/min 600 rpm up to 200 samples High : -2.0 to 16.0 ph / -2.00 to 16.00 ph 0.1 ph / 0.01 ph Accuracy (@25ºC/77ºF) ±0.01 ph Calibration 1, 2, or 3 calibration points; 4 available buffers (4.01; 7.01; 8.20; 10.01) Temperature Compensation manual or automatic from -20 to 120 C (-4 to 248 F) Logging Data Up to 200 samples (ph or mv) mv Meter Accuracy Logged Data Temperature Accuracy Additional Specifications -2000.0 to 2000.0 mv 0.1 mv ± 1.0 mv Up to 200 samples (ph or mv) -20.0 to 120.0 C (-4.0 to 248.0 F) 0.1 C ±0.4 C without probe error meq/l 21.7 to 71.4 as N meq% 2.14 to 7.14 as N mg/l 300 to 1000 as N ph Electrode HI 1131B glass body, refillable, with BNC connector and 1 m (3.3 ) cable (included) Temperature Probe HI 7662-T stainless steel temperature probe with 1 m (3.3 ) cable (included) Environment 0 to 50 C (32 to 122 F); RH max 95% non-condensing Power Supply 12 VDC adapter (included) Dimensions 235 x 200 x 150 mm (9.2 x 7.9 x 5.9 ) Weight 1.9 kg (67.0 oz.) Reagents HI 84533-50 Titrant Solution (230 ml) HI 84533-55 Pump Calibration Standard (120 ml) HI 84533-58 Formol Base Reagent (230 ml) HI 84533-59 ph Adjustment Reagent (30 ml) HI 84533-60 Additional Reagent (30 ml) ph Calibration Solutions HI 7004M HI 7007M HI 70082M HI 7010M Buffer solution ph 4.01 (230 ml) Buffer solution ph 7.01 (230 ml) Buffer solution ph 8.20 (230 ml) Buffer solution ph 10.01 (230 ml) Electrode Fill and Storage Solutions HI 7082 HI 70300L Electrode fill solution (4 x 30 ml) Electrode storage solution (500 ml) Electrode Cleaning Solution HI 70635M HI 70636M Electrodes HI 1131B HI 7662-T Cleaning solution for wine deposits (500 ml) Cleaning solution for wine stains (500 ml) ph Electrode Other Accessories HI 70500 HI 71005/8 HI 71006/8 HI 731319 HI 740036P HI 740236 HI 920013 Temperature probe Tube set with cap for titrant bottle, tip and valve 115 Vac to 12 Vdc, 800 ma 230 Vac to 12 Vdc, 800 ma Stir bar, 25 x 7 mm (10 pcs.) 100 ml Beaker (10 pcs.) 5 ml Syringe for minititrator PC Connection Cable Ordering Information HI 84533-01 (115V) and HI 84533-02 (230V) are supplied with: HI 84533-70 Reagent Kit for formol number in wine and fruit juices HI 1131B ph electrode HI 7662-T temperature probe HI 7082 fill solution (30 ml) HI 740036P Two 100 ml beakers HI 70500 Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), Dosing Pump Valve HI 740236 5 ml Syringe 1 ml plastic pipette HI 731319 stir bar Two sachets each of cleaning solution for wine deposits and wine stains HI 920013 power adapter Instruction manual and quality certificate HannaNorden AB Energigatan 15B S-434 37 KUNGSBACKA Sweden +46 (0)300 404018 info@hannanorden.com www.hannanorden.com