APPLIED. Measuring Caffeine Concentration. Application Summary. Analytes: caffeine (C 8 H 10 N 4 O 2

Similar documents
Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

Determination of Caffeine in Coffee Products According to DIN 20481

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

Beer bitterness and testing

Application Note CL0311. Introduction

Michigan Grape & Wine Industry Council Annual Report 2012

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

EXPERIMENT 6. Molecular Fluorescence Spectroscopy: Quinine Assay

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Validation Report: Total Sulfite Assay Kit (cat. no. K-TSULPH)

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

Application & Method. doughlab. Torque. 10 min. Time. Dough Rheometer with Variable Temperature & Mixing Energy. Standard Method: AACCI

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

HOW MUCH DYE IS IN DRINK?

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

Acidity and ph Analysis

INTERNATIONAL STANDARD

Experiment 6 Thin-Layer Chromatography (TLC)

By Type Still, Sparkling, Spring. By Volume- Liters Consumed. By Region - North America, Europe, Asia Pacific, Latin America and Middle East

Validation Report: Free Sulfite Assay Kit (cat. no. K-FSULPH)

Detecting Melamine Adulteration in Milk Powder

Determination of Metals in Wort and Beer Samples using the Agilent 5110 ICP-OES

Determination of wine colour by UV-VIS Spectroscopy following Sudraud method. Johan Leinders, Product Manager Spectroscopy

Buying Filberts On a Sample Basis

Guidelines and Suggestions for Starting Maltsters

Technology Trends Driving the Adoption of UV LED Curing

Alcohol Meter for Wine. Alcolyzer Wine

ALPHA. Innovation with Integrity. FT-IR Wine & Must Analyzer FT-IR

Barista at a Glance BASIS International Ltd.

Correlation of the free amino nitrogen and nitrogen by O-phthaldialdehyde methods in the assay of beer

Analysis of Beta-Carotene and Total Carotenoids from Pacific Sea Plasma (Spectrophotometric Method)

THE EFFECT OF ETHYLENE UPON RIPENING AND RESPIRATORY RATE OF AVOCADO FRUIT

Determination of Alcohol Content of Wine by Distillation followed by Density Determination by Hydrometry

The Brabender GlutoPeak A new type of dough rheology

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

PECTINASE Product Code: P129

Use of a CEP. CEP: What does it mean? Pascale Poukens-Renwart. Certification of Substances Department, EDQM

Assessment of the CDR BeerLab Touch Analyser. March Report for: QuadraChem Laboratories Ltd. Campden BRI Group contracting company:

Innovations for a better world. Ingredient Handling For bakeries and other food processing facilities

What s New? AlveoLab, SRC-CHOPIN, Mixolab 2. CHOPIN Technologies Geoffroy d Humières

Resolute Reds that endure.

TSKgel TECHNICAL INFORMATION SHEET No. 131

ClearFlux. Dialyzer Regeneration System

PERFORMANCE TESTING. The Decaf Company, LLC 46 Red Birch Court Danville, California 94506

International Journal Of Recent Scientific Research

Mini Project 3: Fermentation, Due Monday, October 29. For this Mini Project, please make sure you hand in the following, and only the following:

Lab 2. Drug Abuse. Solubility and Colligative Properties of Solutions: Coffee, Soda, and Ice Cream

Measuring white wine colour without opening the bottle

White Paper. Dry Ingredient Chilling for Bakery Manufacturers.

3. Aspirin Analysis. Prelaboratory Assignment. 3.1 Introduction

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

Automation of AOAC for the Identification of FD&C Color Additives in Foods using Solid Phase Extraction

Global Cocoa Butter Equivalent (CBE) Market - Volume and Value Analysis By Type, By Region, By Country: Opportunities and Forecast ( )

Chemistry 212 MOLAR MASS OF A VOLATILE LIQUID USING THE IDEAL GAS LAW

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

EXTRACTION. Extraction is a very common laboratory procedure used when isolating or purifying a product.

Estimation of Caffeine Concentration in Decaffeinated Coffee and Tea Available in Pakistan

EFFECT OF TOMATO GENETIC VARIATION ON LYE PEELING EFFICACY TOMATO SOLUTIONS JIM AND ADAM DICK SUMMARY

Separations. Objective. Background. Date Lab Time Name

A NEW, LOW-COST, ON-LINE RGB COLORIMETER FOR WINE INDUSTRY BASED ON OPTICAL FIBERS

Introduction to Measurement and Error Analysis: Measuring the Density of a Solution

Distillation Note Books

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

Flexible gear grinding machines

KNOWLEDGE

Caffeine in Energy Drinks

ISO 9852 INTERNATIONAL STANDARD

SUNFLOWER OIL & MEAL. WORLDWIDE SOFT COMMERCIAL OFFER. Montreux, Switzerland,

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

Company Coverage. Country Coverage. Global Coverage. Regional Coverage

The Premium Benefits of Steam Infusion UHT Treatment

Dust Introduction Test to determine ULPA Filter Loading Characteristics in Class II Biosafety Cabinets

Grower Summary TF 170. Plums: To determine the performance of 6 new plum varieties. Annual 2012

LEAN PRODUCTION FOR WINERIES PROGRAM

Specify the requirements to be met by agricultural Europe Soya soya bean collectors and Europe Soya primary collectors.

THIN LAYER CHROMATOGRAPHY AND MELTING POINT DETERMINATION: DETECTION OF CAFFEINE IN VARIOUS SAMPLES

Brooks 1250/55 Sho-Rate TM Series Glass Tube Flowmeters

, FAX

Mastering Measurements

Determination of caffeine content in tea and soft drink. BCH445 [Practical] 1

Elemental Analysis of Yixing Tea Pots by Laser Excited Atomic. Fluorescence of Desorbed Plumes (PLEAF) Bruno Y. Cai * and N.H. Cheung Dec.

UTZ Coffee Statistics Report 2017

Liquids Handling in Bakeries.

VQA Ontario. Quality Assurance Processes - Tasting

WineScan All-in-one wine analysis including free and total SO2. Dedicated Analytical Solutions

DEVELOPMENT OF A RAPID METHOD FOR THE ASSESSMENT OF PHENOLIC MATURITY IN BURGUNDY PINOT NOIR

AWRI Refrigeration Demand Calculator

An Overview of Official Methods of Analysis

SWISS WATER Logo Usage Guidelines

COURSE FOD 3030: CREATIVE BAKING

Profiling of Aroma Components in Wine Using a Novel Hybrid GC/MS/MS System

Guideline to Food Safety Supervisor Requirements

Lab 2. Drug Abuse. Solubility and Colligative Properties of Solutions: Coffee, Soda, and Ice Cream

UNECE STANDARD FFV-35 concerning the marketing and commercial quality control of STRAWBERRIES 2017 EDITION

Measuring tannins in grapes and red wine using the MCP (methyl cellulose precipitable tannin assay

Transcription:

Application Summary Analytes: caffeine (C 8 H 10 N 4 O 2 ) Detector: OMA-300 Process Analyzer (UV-Vis spectrophotometer) Introduction While it may mystify those of us that need strong coffee to get through the workday, some people actually drink decaf (decaffeinated coffee), whether for health reasons (high blood pressure, hypertension, sleep difficulties), pregnancy cautions, or personal preference. In lieu of more firm legal standards, decaf is supposed to have its caffeine content reduced by no less than 97.5% of the source coffee (USDA guideline). Accurate validation of the caffeine levels in decaffeinated coffee bean batches would reduce APPLIED TM A N A L Y T I C S 1

sensitive consumers health risks by preventing the wildly inconsistent caffeine levels among available decaf blends (as documented by the Journal of Analytical Toxicology). Moreover, producers can use real-time caffeine monitoring to conclude the decaffeination cycle as soon as the specified caffeine threshold is achieved, thus wasting no more caffeine solvent or production time than absolutely necessary. An online analysis solution would provide continuous, live caffeine measurement in an automated fashion. The High- Performance Liquid Chromatography (HPLC) methods currently used in some caffeine applications is quite costly to own and maintain while delivering slow response. Using OMA to Measure Caffeine Concentration in Decaffeination Processing While certain selective solvents are extremely effective at removing caffeine from coffee beans, many of these chemicals have been classified as carcinogenic or toxic. Though less powerful, the supercritical CO 2 extraction method is a harmless decaffeination process common in large-scale operations. Supercritical CO 2 fluid is a hybrid gaseous/liquid resource maintained by exceeding the critical temperature (31 C) and pressure (73 atm) of CO 2 ; for the supercritical CO 2 to act as an effective solvent for caffeine molecules, it actually has to be kept at more extreme conditions (around 94 C and 225 atm). These conditions are expensive to maintain, and the 10-hour process cycle is time-consuming. The caffeine extract is sold off to pharmaceutical and soft drink companies, but this only partially alleviates process cost. With real-time caffeine monitoring at ±1 ppm accuracy, the OMA-300 Process Analyzer allows decaf coffee producers to automatically end an extraction cycle when the specified caffeine maximum is reached. Doing away with the preset 10-hour cycle, this method banishes both overprocessing (which wastes production resources) and underprocessing (which upsets customers). While highly suitable for monitoring the 0-1,000 ppm caffeine range established by international standards as legally decaf, the OMA-300 s UV-Vis spectrophotometer has a true detection limit of 1 ppm caffeine, thus theoretically capable of validating a cup of perfect decaf. Importance of Using a UV-Vis Spectroscopic Method The defining advantage of the ultraviolet-visible (UV-Vis) range in caffeine analysis is the transparency of the process background to the detector. Systems using infrared (IR) spectroscopy will suffer interference from water or CO 2 because these compounds absorb IR radiation; these systems may require drying the sample or expensive sample handling. Since water and CO 2 have no absorbance in the UV-Vis range, they appear totally transparent to the OMA spectrophotometer. This is extremely important for typical caffeine applications such as:»» caffeine in supercritical CO 2 stream»» caffeine in water or liquids containing water 2

Dynamic Range in Caffeine Measurement Any single photodiode measurement is vulnerable to noise, signal saturation, or unexpected interference. This susceptibility to error makes a lone photodiode data point an unreliable indicator of one chemical s absorbance. As accepted in the lab community for decades, the best way to neutralize this type of error is to use collateral data in the form of confirmation wavelengths, i.e. many data points at many wavelengths instead of a single wavelength. The same principle holds true for sustaining accuracy across a very wide concentration range. An instrument that only measures one wavelength at a pre-determined absorbance peak will suffer from signal clipping: above a certain concentration, all of the signal at that wavelength will be absorbed and higher concentrations cannot be measured. The full-spectrum technology used by the OMA removes this limitation by measuring at many wavelengths simultaneously. To illustrate this capability, the spectrum below shows the shape of the UV-Vis absorbance curve intrinsic to the caffeine molecule. Each range of caffeine concentration has a most suitable wavelength region of analysis based on the relative height of the absorbance curve within that region: Caffeine Absorbance Spectrum Medium Range: 0.5-1% wt Low Range: 0-0.5% wt High Range: 1-10% wt When processing the raw data from the spectrophotometer, the OMA s proprietary ECLIPSE software runs three analysis models in parallel each assigned to a unique wavelength region to measure caffeine concentration at different ranges. These parallel models ensure that the measurement always compensates for an error at a single photodiode due to overabsorbance or light saturation. Consider the example of the Low Range: when caffeine concentration rises above 0.5% wt, the sample will absorb strongly enough that the diodes measuring at the 260-284 nm region will register zero light. At >0.5% wt concentration level, these diodes cease to be reliable due to signal clipping. Meanwhile, the absorbance curve is naturally lower in the 235-260 nm region (Medium Range), and the diodes reading these wavelengths are still receiving an optimal absorbance signal. The OMA system always runs all three models simultaneously, reporting each as a separate output. Optional system logic can create a unified output which always reports from the appropriate model (Low, Medium, or High) based on the current caffeine concentration in the sample. In this manner, the OMA provides seamless dynamic range with sustained accuracy through large fluctuations. 3

Absorbance-to-Concentration Correlation In the figures below, each diamond in a curve represents a single photodiode and data point. The OMA measures absorbance at each integer wavelength from 200-800 nm and produces a caffeine absorbance curve. After being calibrated on a full spectrum of pure caffeine at known concentration, the OMA knows the absorbance-concentration correlation for each wavelength. This is the equivalent of using hundreds of single-wavelength photometers simultaneously, averaging the concentration calculated from each data point to eradicate the effect of noise at any single photodiode. Caffeine Absorbance Curves at Low Range (0.01% wt to 0.05% wt) Caffeine Absorbance Curves at High Range (1% wt to 5% wt) Only a full-spectrum instrument can provide the rich raw data necessary to accurately measure caffeine concentration from very low to very high levels. 4

The specifications below represent performance of the OMA-300 Process Analyzer in a typical caffeine application. For technical details about the OMA-300 Process Analyzer, see the data sheet: http://aai.solutions/documents/aa_ds001a_oma300.pdf All performance specifications are subject to the assumption that the sample conditioning system and unit installation are approved by Applied Analytics. For any other arrangement, please inquire directly with Sales. Subject to modifications. Specified product characteristics and technical data do not serve as guarantee declarations. Application Data Performance Specifications Accuracy Custom measurement ranges available; example ranges below. 0-100 ppm: ±1 ppm caffeine 0-1,000 ppm: ±1% full scale 0-10%: ±1% full scale 5

Revised 12 April 2017 Further Reading Subject OMA Series Process Analyzers Brochure OMA-300 Process Analyzer Data sheet Advantage of Collateral Data Technical Note Location http://aai.solutions/documents/oma.pdf http://aai.solutions/documents/aa_ds001a_oma300.pdf http://aai.solutions/documents/aa_tn-202_collateraldata.pdf References McCusker, Rachel R., Brian Fuehrlein, Bruce A. Goldberger, Mark S. Gold, and Edward J. Cone. Caffeine Content of Decaffeinated Coffee. Journal of Analytical Toxicology 30.8 (2006): 611-13. is a registered trademark of Applied Analytics, Inc. www.aai.solutions Headquarters Applied Analytics, Inc. Burlington, MA sales@aai.solutions North America Sales Applied Analytics North America, Ltd. Houston, TX sales@appliedanalytics.us Asia Pacific Sales Applied Analytics Asia Pte. Ltd. Singapore sales@appliedanalytics.com.sg Middle East Sales Applied Analytics Oil & Gas Operations, L.L.C. Abu Dhabi, UAE sales@appliedanalytics.ae India Sales Applied Analytics (India) Pte. Ltd. Mumbai, India sales@appliedanalytics.in Europe Sales Applied Analytics Europe, AG Genève, Switzerland sales@appliedanalytics.eu Brazil Sales Applied Analytics do Brasil Rio de Janeiro, Brazil vendas@aadbl.com.br 2017 Applied Analytics, Inc. Products or references stated may be trademarks or registered trademarks of their respective owners. All rights reserved. We reserve the right to make technical changes or modify this document without prior notice. Regarding purchase orders, agreed-upon details shall prevail. 6