three different household steam ovens, representing a number of identically constructed ovens (see attached list at the end of this document):

Similar documents
Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

TSKgel TECHNICAL INFORMATION SHEET No. 131

Determination of natamycin in wines Résolution OIV-SCMA

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

Determination of Caffeine in Coffee Products According to DIN 20481

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

! " # # $% 004/2009. SpeedExtractor E-916

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

A COMPARATIVE STUDY OF THE CAFFEINE PROFILE OF MATURE TEA LEAVES AND PROCESSED TEA MARKETED IN SONITPUR DISTRICT OF ASSAM, INDIA.

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

DNA extraction method as per QIAamp DNA mini kit (Qiagen, Germany)

III. RESEARCH METHODOLOGY

EXTRACTION PROCEDURE

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

Test sheet preparation of pulps and filtrates from deinking processes

Bromine Containing Fumigants Determined as Total Inorganic Bromide

ASSET EZ4-NCO Dry Sampler Extraction Procedure.

Higher Resolution Separation of Organic Acids and Common Inorganic Anions in Wine

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Identification & Estimation of Melamine Residue in Powdered Milk by RP-HPLC

Estimation of Caffeine Concentration in Decaffeinated Coffee and Tea Available in Pakistan

Ochratoxin A N H. N-{ [(3R)-5-chloro-8-hydroxy-3-methyl-1-oxo-3,4-dihydro-1H-isochromen-7-yl]carbon yl}- L-phenylalanine

EXTRACTION OF SEDIMENTS FOR AROMATIC AND CHLORINATED HYDROCARBONS

COMPENDIUM OF INTERNATIONAL METHODS OF ANALYSIS - OIV Volatile acidity. Volatile Acidity

Identification of reconstituted milk in pasteurized and UHT milk

Rapid Tea Analysis on Poroshell 120 SB-C18 with LC/MS

Solid Phase Micro Extraction of Flavor Compounds in Beer

PECTINASE Product Code: P129

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

High Sensitivity Quantitation Method of Dicyandiamide and Melamine in Milk Powders by Liquid Chromatography Tandem Mass Spectrometry

National Food Safety Standard

A Fast Method for Sugar Analysis of Instant Coffee Samples

APPLICATIONS TN Fast and Robust Analysis of Organic Acids from Wine using HPLC-UV. Introduction. Results and Discussion. Materials and Methods

HPLC Organic Acid Analysis in Different Citrus Juices under Reversed Phase Conditions

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Practical 1 - Determination of Quinine in Tonic Water

Analysis of Beta-Carotene and Total Carotenoids from Pacific Sea Plasma (Spectrophotometric Method)

General overview of the two stages of the QuEChERS technique. Stage 1: Sample extraction. Stage 2: Sample cleanup

Determination of Metals in Wort and Beer Samples using the Agilent 5110 ICP-OES

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

FAT, TOTAL (Hydrolysis)

One class classification based authentication of peanut oils by fatty

Chapter 14 Tex-619-J, Analysis of Water for Chloride and Sulfate Ions

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Determination Of Saponin And Various Chemical Compounds In Camellia Sinensis And Genus Ilex.

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

COMMISSION DIRECTIVE 2009/122/EC

Application Note No. 184/2015

Methanol (Resolution Oeno 377/2009, Revised by OIV-OENO 480/2014)

The Determination of Pesticides in Wine

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft COMMISSION DIRECTIVE../ /EC

Analysis of Resveratrol in Wine by HPLC

Table 1: Experimental conditions for the instrument acquisition method

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

Determination of Coumarins in Cosmetics

AppNote 13/2012. Automated Solid Phase Extraction (SPE)-LC-MS/MS Method for the Determination of Acrylamide in Brewed Coffee Samples KEYWORDS ABSTRACT

Solid Phase Micro Extraction of Flavor Compounds in Beer

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

C27 Chromatography. Collect: Column Mortar and pestle Dropper (229 mm) Capillary tube TLC plate Aluminum foil UV light

Alcohol Meter for Wine. Alcolyzer Wine

Yeast nuclei isolation kit. For fast and easy purification of nuclei from yeast cells.

Data Pack. Ultra Low Flow Methods. September 2009

Separations. Objective. Background. Date Lab Time Name

CHEM Experiment 4 Introduction to Separation Techniques I. Objectives

ASTM D6042 Calibration Mixture

Caffeine in Energy Drinks

Determination of Alcohol Content of Wine by Distillation followed by Density Determination by Hydrometry

EXPERIMENT NO. 3 HYDROMETER ANALYSIS ASTM D-422

AAB BIOFLUX Advances in Agriculture & Botanics- International Journal of the Bioflux Society

RAPID, SPECIFIC ANALYSIS OF MELAMINE CONTAMINATION IN INFANT FORMULA AND LIQUID MILK BY UPLC/MS/MS

Production, Optimization and Characterization of Wine from Pineapple (Ananas comosus Linn.)

SUPPLEMENTARY MATERIALS. Methylxanthine content in commonly consumed foods in Spain and determination of its intake during consumption

MALT & BACTERIAL BETA-GLUCANASE & CELLULASE

ph and Low Level (10 ppm) Effects of HB2 Against Campylobacter jejuni

Draft for comments only Not to be cited as East African Standard

HPLC/UV determination of organic acids in fruit juices and nectars

Synthesis 0732: Isolating Caffeine from Tea

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

Application Note CL0311. Introduction

ION FORCE DNA EXTRACTOR FAST Cat. N. EXD001

RESOLUTION OIV-OENO DETECTION OF CHITINASE AND THAUMATIN-LIKE PROTEINS IN WHITE WINES

Allergens in wine a specific detection of Casein, Egg and Lysozyme

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Asian Journal of Food and Agro-Industry ISSN Available online at

F3625 F Poxygrid Lead Ring Holder 1 $12.50

MEASUREMENTS IN AND NEAR CONTAINERS DURING FUMIGATION

Somchai Rice 1, Jacek A. Koziel 1, Jennie Savits 2,3, Murlidhar Dharmadhikari 2,3 1 Agricultural and Biosystems Engineering, Iowa State University

[ application note note ] ]

INTERNATIONAL STANDARD

Supporting Information

10. THE ROLE OF PLANT GROWTH REGULATORS IN THE DEVELOPMENT, GROWTH AND MATURATION OF THE FRUIT

SOLUTIONS IN BRIX MEASUREMENT

Department: DOC#: 1 REV: Effective Date: Supersedes: Subject: Blue Cheese from Pasteurized Milk

1. Blender: Osterizer, 10-speed, or equivalent. 2. Separatory Funnel: Kilborn or equivalent (see figure 1) 2. HCl Solution: HCl/water (7:93 by volume)

Transcription:

This is to confirm to BSH Hausgeräte GmbH Carl-Wery-Str. 34 D-81739 München that within a study (reports March 26 th,2015; June 18 th, 2015; July 16 th, 2015) conducted by Universidad Zaragoza (Plant Foods Research Group) on behalf of BSH Hausgeräte GmbH at three different household steam ovens, representing a number of identically constructed ovens (see attached list at the end of this document): a full size steam oven (Bosch HSG856XS1) a compact full steam oven (Neff C17FS42N0) a compact pure steam oven (Siemens CD634GBW1) in which potatoes and peppers of different shapes and sizes were steamed and the retention of Vitamin C (potatoes and peppers) as well as nicotinamide and riboflavin (only potatoes) was measured. Within the used test conditions (see next pages) following findings concerning nutrient retention can be stated: Vitamin C retention in potatoes varies between 70 and 79 % for the full steam ovens and between 87 and 70 % for the pure steam oven. The nicotinamide retention in potatoes varies from 90 to 95 % and the riboflavin retention from 92 to 97 % for all ovens. The vitamin C retention in peppers varies from 78 to 73 % for full size full steam oven, from 85 to 91 % for the compact full steam oven and from 84 to 90 % for the pure steam oven. Zaragoza, December 21 st, 2016 Name: María Luisa Salvador Solano Function: Associated Professor Page 1

The aim of the study was to analyze the nutrients retention in the steaming of some vegetables. Therefore Agata potatoes and California peppers were steamed using three different ovens: a full size steam oven (Bosch HSG856XS1) a compact full steam oven (Neff C17FS42N0) a compact pure steam oven (Siemens CD634GBW1). For all tested ovens identically constructed appliances from BSH series EOX6 of the brands Bosch, Siemens and Neff are available. An according list of identically constructed appliances is attached to this report. The tests were carried out according to the analysis method described in an attached document as follows: The potatoes, adjusted to 20 ºC, were peeled off, washed, drained and cut into cubes of approximately 2 cm or 3 cm of lateral length or into slices of 3 cm diameter and 1 cm thickness. The peppers at the refrigerator temperature (around 6 ºC) were washed, dried and cut into stripes (0.3-0.7 cm 3-5 cm) or squares (3-4 cm 3-4 cm). The products were put in a perforated gastronorm container without salt or seasoning. The amount of potatoes was 250g or 500 g, and 350 g for peppers. In the pure steam oven and in the full size full steam oven the product was located at level 3 and at level 2 in the compact full steam oven. In all cases the heating mode was Steam 100 ºC. The cooking time was the shortest time needed to have completely cooked vegetables. That is 16 min for potatoes cut in 2 cm cubes or slices and 21 min for 3 cm cubes, independently of the oven. The cooking time for peppers was 7 min for stripes and 5 min for squares when the pure steam and full size full steam ovens were used, while shorter cooking times were used for compact full steam oven (6 min for stripes and 4 min for squares). Vitamin C was analyzed in potatoes and peppers, and nicotinamide and riboflavin were also quantified in potatoes. To obtain the percentage of retention, the vitamins were analyzed in raw and in cooked vegetables. The vitamins were determined by a high performance liquid chromatography method (HPLC) using a Hewlett Packard (Series 1100) chromatograph. The results obtained in the analysis of potatoes, reveal that the percentage of retention of vitamin C varies between 70 and 79 % when the full steam ovens were used and neither the shape nor the weight of potatoes influences the retention of vitamin C. For the pure steam oven the vitamin C retention varies between 87 and 70 %. In this case, the shape and the amount of the potatoes appear to influence the retention of this nutrient. The cubes of 2 cm and the slices were steamed during the same time, but the cooking slices retain less amount of vitamin C. The losses of vitamin C are more pronounced for 500 g than for 250 g although these differences are only significant Page 2

(p<0.05) for 2 cm cubes. The cause for this fact might be the different area of the perforated tray covered by the potato pieces and as a consequence the condensation of the steam over the product and the leaching could be take place in a different extent. The nicotinamide retention in potatoes varies from 90 to 95 % and from 92 to 97 % for riboflavin retention, regardless, in both cases, of steaming conditions and oven. From the results of the pepper analysis can be concluded that the retention of vitamin C does not depend significantly on the shape of the product, and varies from 78 to 73 % for full size full steam oven, from 85 to 91 % for compact full steam oven and from 84 to 90 % for pure steam oven. Page 3

List of identically constructed appliances Identically constructed pure steam ovens: Appliance Description Series Brand CD634GBS1 Height 45 cm EOX6 Siemens CD634GBS1B Height 45 cm EOX6 Siemens CD634GBS1W Height 45 cm EOX6 Siemens CD634GBW1 Height 45 cm EOX6 Siemens Tested model CD834GBS1 Height 45 cm EOX6 Siemens CD834GBB1 Height 45 cm EOX6 Siemens CDG634BB1 Height 45 cm EOX6 Bosch CDG634BB1W Height 45 cm EOX6 Bosch CDG634BS1 Height 45 cm EOX6 Bosch CDG634BS1B Height 45 cm EOX6 Bosch CDG634BS1W Height 45 cm EOX6 Bosch CDG634BW1 Height 45 cm EOX6 Bosch CDG634BW1W Height 45 cm EOX6 Bosch Identically constructed full steam ovens (60 cm): Appliance Description Series Brand HS636GDS1 Height 60 cm EOX6 Siemens HS636GDS1C Height 60 cm EOX6 Siemens HS636GDS1W Height 60 cm EOX6 Siemens HS636GDW1W Height 60 cm EOX6 Siemens HSG636BB1 Height 60 cm EOX6 Bosch HSG636BS1 Height 60 cm EOX6 Bosch HSG636BW1 Height 60 cm EOX6 Bosch HSG636ES1 Height 60 cm EOX6 Bosch HSG636ES1C Height 60 cm EOX6 Bosch HSG636ES1W Height 60 cm EOX6 Bosch HSG636XS6 Height 60 cm EOX6 Bosch HSG656RS1 Height 60 cm EOX6 Bosch HSG656XS1 Height 60 cm EOX6 Bosch HSG656XS6W Height 60 cm EOX6 Bosch HSG856XB6 Height 60 cm EOX6 Bosch HSG856XS1 Height 60 cm EOX6 Bosch Tested model HSG856XS6 Height 60 cm EOX6 Bosch Page 4

Identically constructed full steam ovens (45 cm): Appliance Description Series Brand C15FS22N0 Height 45 cm EOX6 Neff C15FS24N0 Height 45 cm EOX6 Neff C17FS32N0B Height 45 cm EOX6 Neff C17FS42N0 Height 45 cm EOX6 Neff C17FS52N0 Height 45 cm EOX6 Neff Tested model C87FS22N0 Height 45 cm EOX6 Neff C87FS32N0 Height 45 cm EOX6 Neff C87FS32N0B Height 45 cm EOX6 Neff CS636GBS1 Height 45 cm EOX6 Siemens CS656GBS1 Height 45 cm EOX6 Siemens CS656GBS1B Height 45 cm EOX6 Siemens CS656GBS1W Height 45 cm EOX6 Siemens CS656GBW1 Height 45 cm EOX6 Siemens CS856GBS1S Height 45 cm EOX6 Siemens CS856GDB6S Height 45 cm EOX6 Siemens CS856GDW6S Height 45 cm EOX6 Siemens CS856GPS1 Height 45 cm EOX6 Siemens CS856GPB6 Height 45 cm EOX6 Siemens CSG636BS1 Height 45 cm EOX6 Bosch CSG636BS2 Height 45 cm EOX6 Bosch CSG656BS1 Height 45 cm EOX6 Bosch CSG656BS1B Height 45 cm EOX6 Bosch CSG656BS1I Height 45 cm EOX6 Bosch CSG656BS1W Height 45 cm EOX6 Bosch CSG656RB1 Height 45 cm EOX6 Bosch CSG656RB6 Height 45 cm EOX6 Bosch CSG656RS1 Height 45 cm EOX6 Bosch CSG656RS1A Height 45 cm EOX6 Bosch CSG656RS6 Height 45 cm EOX6 Bosch CSG656RW1 Height 45 cm EOX6 Bosch CSG656RW6 Height 45 cm EOX6 Bosch CSG856NS1 Height 45 cm EOX6 Bosch CSG856RB6 Height 45 cm EOX6 Bosch CSG856RS1 Height 45 cm EOX6 Bosch CSG856RS6 Height 45 cm EOX6 Bosch Page 5

ANALYSIS METHOD Vitamin C analysis: Apparatus: The vitamins were determined by a high performance liquid chromatography method (HPLC), using a Hewlett Packard (Agilent-Series 1100) chromatograph equipped with the following modules: Degasser (G1322 A, 1100 Series) Quaternary pump (G1311 A, 1100 Series) Autosampler (G1313 A, 1100 Series) Photodiode array detector (DAD) (G1315 B, 1100 Series) Chromatography column: Discovery RP Amide C16, 5 m, 15 cm x 4.6 mm supplied by Supelco Analytical. Analysis conditions: - Injection volume: 20 L - Flow-rate of the mobile phase:1 ml/min - Time of analysis: 10 min - Temperature: 40 ºC - Mobile phase: HPLC grade water with metaphosphoric acid to ph2.2 Commercial standards: Ascorbic acid 99.7 % (Merck, Ref:1.00127.0100) Calibration: Commercial Standard Ascorbic acid (time=2.6 min) Intercept Slope (L/mg) Interval Correlation (nm) coefficient 245 7.463±0.635 94.458±1.363 1-50 mg/l 0.995 Extraction procedures: Potatoes: Five grams of homogenate were mechanically stirred in 10 ml of a 4.5 % (w/v) solution of metaphosphoric acid for 15 min. The mixture was vacuum-filtered. The permeated was mixed with other 10 ml of the same metaphosphoric acid solution and vacuum filtered again. The filtrate was diluted until obtaining a total final volume of 25 ml with metaphosphoric acid solution. An aliquot was filtered through a 0.45 m Millipore filter prior to injection into the chromatographic column. To ensure that the samples were representative, all pieces of potatoes were mixed doing a paste and Page 6

afterwards 6 samples of 5 g were analysed separately. Two or three replicates were performed for each condition. Peppers: Five grams of peppers were cut into small pieces with a ceramic knife. 10 ml of a 4.5 % (w/v) solution of metaphosphoric acid was added. The mix was homogenized in an ultraturrax for 2 min. The weight of the samples was balanced with other 10 ml of the same metaphosphoric acid solution. The samples were centrifuged at 4000 rpm for 20 min. The upper liquid was vacuum filtered. The filtrate was diluted until obtaining a total final volume of 25 ml with metaphosphoric acid solution. An aliquot was filtered through a 0.20 m Millipore filter prior to injection into the chromatographic column. To ensure that the samples were representative, the squares or the stripes of raw or cooked peppers, were cut into small pieces and afterwards 6 samples of 5 g were analysed separately. Two replicates were performed for each condition. Therefore, 12 samples for each cooking condition were analysed. Vitamin B analysis: Apparatus: The vitamins were determined by a high performance liquid chromatography method (HPLC), using a Hewlett Packard (Agilent-Series 1100) chromatograph equipped with the following modules: Degasser (G1322 A, 1100 Series) Quaternary pump (G1311 A, 1100 Series) Autosampler (G1313 A, 1100 Series) Photodiode array detector (DAD) (G1315 B, 1100 Series) Chromatography column: Discovery RP Amide C16, 5 m, 15 cm x 4.6 mm supplied by Supelco Analytical. Analysis conditions: - Injection volume: 100 L - Flow-rate of the mobile phase:1 ml/min - Time of analysis:47 min - Temperature: 25 ºC - Solvents: Initial isocratic step with 10 mm phosphate buffer at ph 6.5 for 13 min followed by a linear gradient to acetonitrile-buffer (6:94 v/v) mixture during 1 min, this mixture being held for 6 min. Then a second linear gradient to acetonitrile-buffer (12:88, v/v) mixture 1 min and held for 15 min. Commercial standards: - Nicotinamide 99.5 % HPLC. Sigma-Aldrich Chemie GmbH - Riboflavin 98 %. Alfa Aesar Gmb&CoKG. Page 7

Calibration: Commercial Standard (nm) Intercept Slope (L/mg) Interval Correlation coefficient Nicotinamide 266 2.279±0.107 122.920±0.842 0.5-20 mg/l 0.999 Rivoflavin 266 2.901±0.297 370.369±12.886 0.02-0.4 mg/l 0.996 Extraction procedures: Samples (10 g) were subjected to successive hydrolysis with hydrochloric acid (60 ml, 0.1 M). The suspensions were homogenized for 30 s and then heated in a water bath at 100 ºC for 30 min. The suspensions were cooled in an ice-water bath during 5 min. When they were cold, the ph was adjusted to 4 using 2 M sodium acetate. Taka-diastasa (0.5 g) was added for the enzyme hydrolysis. The samples were maintained at 50 ºC during 16 h. Then, 1 ml of 50% (w/v) trichloroacetic acid was added and the samples were again introduced into a water bath at 90 ºC during 10 min. When the samples were cold, the ph was adjusted to 6.5 with 10 M potassium hydroxide, and they were quantitatively transferred to a 100 ml calibrated flask using the mobile phase buffer (10mM potassium hydroxide ph 6.5). Aliquots were centrifuged at 4000 rpm for 15 min, filtered through a 0.2 m polyamide Millipore chromatographic filter and injected into the chromatograph. To ensure that the samples were representative, all pieces of potatoes were mixed doing a paste and afterwards six samples of 10 g were analysed separately. Two or three replicates were performed for each condition. Page 8