TeleREC 2 / TeleREC Top / TeleREC Plus

Similar documents
Position switches FL series

ZANOLLI. Pizza ovens. Spare parts for: Suitable for:

Surface-Mounted Thermostat ATH series

Built in Electric Fan Oven

CMC DUO. Standard version. Table of contens

AS450, AS600, G1, SG630

Surface-Mounted Thermostat ATH series

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with EN certified safety function (spring down)

Product Presentation. C-series Rack Ovens

PUBLICIMBALI /2016 FEME Gruppo Cimbali S.p.A. Via Manzoni, Binasco (MI) Italy Tel

MODELS SHOWN: BICM24CS BUILT-IN COFFEE MACHINE AND WDC30JP WARMING DRAWER

ENZX. EBARA Submersible Slurry Pump. Contents Project: Model: Chk d: Date:

» Red wine mash flooder FD-MÜ

TEA CATER USER MANUAL. UM_EN Part No.:

WE CAN HELP. Smart Coffee Maker User Manual. Can t connect? Need help? DO NOT RETURN THIS PRODUCT TO THE STORE

Design celebrates functionality.

Metallized Polyester Film Capacitors (MKT-S) Axial Leads B High reliability capacitor Encapsulated in metal tube

288 MODEL BICM24CS SHOWN WITH WD30EP WARMING DRAWER

Metallized Polyester Film Capacitors (MKT) in Plastic Case B B Standard applications

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

PARTS CATALOG ESPRESSO EP SYSTEM

User Manual VZ46BHK VZ110BDHK/ VZ120BHK VZ150BDHK/ VZ166BHK

RG4 AND RG7 INSTALLTION AND MAINTENANCE

User manual COFFEE QUEEN. Tower 10 litre for wall mounting. Your retail dealer. U / GB Rev

TKMSX-15 COFFEE ROASTER

SELECTION GUIDE UNSEALED SNAP ACTION

So small, but yet so big.

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

Liquajuice Pro Slow juicer

MY MILKY PRO. ENGLISH: 1-22 FRENCH: INSTRUCTION MANUAL

A N F I M Srl. Caimano: Timer / Automatico / Manuale Super Caimano: Timer / Automatico Caimano SPecial 450: Timer / Automatico

ITALFORNI. Pizza ovens. Spare parts for: Suitable for:

REMAPRESS IVE. Pioneering, innovative, certified by German TÜV. HIGH PERFORMANCE vulcanizing technology

User Manual. Stainless Steel Coffee Urns. Models: 177CU55ETL, 177CU110ETL 10/2016. Please read and keep these instructions. Indoor use only.

Universal Ignitor Upgrade Kit

Coffee System Troubleshooting and Repair

SF4750VCAO. Functions. Versions. cortina. Main Oven Plus Main Oven

ORIGINAL LINE A USER MANUAL

5KCG0702 W A_Final.indd 1 8/4/15 8:35 AM

Coffee Grinder Instruction Manual

CBS-7000 Series Coffee/Tea Brewers and Dispensers. High Volume Brewing

AG/77 roller garage doors

DOU330X1. classica ELECTRIC THERMOVENTILATED OVEN,PYROLITIC, DOUBLE 30", CLASSICA, ANTIFINGERPRINT STAINLESS STEEL EAN13: MAIN OVEN

Scishare Coffee Machine

TYPE AESTHETICS CONTROLS PROGRAMS / FUNCTIONS OPTIONS TECHNICAL FEATURES

User Guide TEA CATER. Your Dealer. U / EN Rev

Downflow Booths. Highest operator protection

ROGA. Food processing equipment. Spare parts for: Suitable for:

CERTOMAT R Benchtop shaker with magnetic drive

blue 1 group 2 groups

Any questions? Contact us at Telephone:

VIN AU VERRE 8.0. For an efficient & well managed wine by the glass service! Solutions for displaying and serving wine

MDD. High Speed Mixer. Member of the

ROLLER GRILL. Cooking equipment. Spare parts for: Suitable for:

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MMCX CONNECTORS

TOWER Marin 2 x 5 Litre

Product Family: Oven Category: 60cm

Lead spacing Diameter d 1 Type

Lead spacing Diameter d 1 Type

STAINLESS STEEL MILK FROTHER. Model: PKFMR11BK

CAFFE. CAPPUCCINO. AUTOCAPPUCCINO!

For Beer with Character

TOASTER OVEN USER MANUAL MODEL: PKMFT039

UH8 Installation Manual. Installation. Insert clip here. Then Slide down to lock in place. Description. 2 Wiring Centre.

BLT-E ELECTRIC FLOOR MODEL BRAISING PAN WITH MANUAL TILT INSTALLATION OPERATION MAINTENANCE

A951A/S PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

PrevaLED Bar G3. Dimension (l x w x h) 280 mm x 55 mm x 5 mm 560 mm x 55 mm x 5 mm

Albany Plus. Available in both matt chrome and satin brass finishes, Albany Plus brings stylish yet robust good

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

Franke Coffee Systems Evolution Plus: even more choice at the touch of a button.

USER MANUAL SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS BSC01

12 CUP COFFEE MAKER User Guide

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

Time-setting options: Delay start and automatic end cooking

CF CENEDESE. Cooking equipment. Spare parts for: Suitable for:

PLEASE READ THIS MANUAL BEFORE USE. SAVE FOR FUTURE REFERENCE.

Half-Pint Soft Serve Ice Cream Maker

Digital Menu Boards Overview

AREA: TECHNOLOGY CLOTHED BY ITALIAN DESIGN.

TYPE AESTHETICS CONTROLS PROGRAMS / FUNCTIONS OPTIONS TECHNICAL FEATURES

Orion Plus metal IP65 enclosures

Pellet Pro 12 & 18 Lengths Large 35lb Hopper Assembly Operation Manual

CERTOMAT S II Orbital benchtop shaker

CHOCOLINO CAFÉLINO USER MANUAL UM_EN. Part No.: _01

12 CUP COFFEEMAKER User Guide

SF140E. SMEG S.p.A. Via Leonardo da Vinci, Guastalla (RE) Tel Functions. linea. Main Oven Plus Main Oven

SF4140MC. SMEG S.p.A. Via Leonardo da Vinci, Guastalla (RE) Tel Functions. Versions. linea. Main Oven Plus Main Oven

CAIMANO SPECIAL450 BARISTA

MAGNETIC HID BALLASTS Ballasts-to-Lamp Remote Mounting Distances

Downloaded from Quick Start Guide D512. Smart Decanter

TR4110PF. Victoria. 110cm "Victoria" Traditional Dual fuel 4 cavity Cooker with Gas hob, Cream. Energy rating AA.

Preparing your electric oven for use: Setting the clock. Using the oven. Temperature

think process! INSTORE BAKING As individual as your branch store

User Manual. Stainless Steel Coffee Urns. Models: 177CU30, 177CU55, 177CU110 04/2018. Please read and keep these instructions. Indoor use only.

SEMOLINA TECHNOLOGY ENLIGHTENED

professional pill grinder User manual Please read this user manual carefully before use!

CAFEMINO GAS TKMSX-1 COFFEE ROASTER

TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

USER MANUAL. Fully-automatic Coffee Machine

Transcription:

GE Industrial Solutions New TeleREC TeleREC 2 / TeleREC Top / TeleREC Plus Automatic reclosing system for demanding applications GE imagination at work

2 Advantages and benefits RANGE OVERVIEW 4 TeleREC 2 - RCCBs 6 TeleREC 2-2P RCBOs 8 TeleREC Top 10 TeleREC Plus 11 Dimensions 12 Numerical index Automatic reclosing system for demanding applications 1

TeleREC 2 Double clips to the DIN-rail Strong fixation to the DIN-rail throughout Two clips for 2P and 4P version. Interlock M2 hole to attach a seal or packlock to block access to the RCCB or RCBO in case of works downstream. 4 Poles version Changeover contact in 4P RCCB version to indicate the TeleREC 2 status remotely. Transparent windows Transparent windows covering the RCCB following EN 50557 and with a visor to identify the RCCB or RCBO properly. DIN-rail Easy clip-on CO contact 4 Poles Top view Transparent windows Clear visor Interlock M2 hole below lever 2

Top Monitorised control Complete screen, buttons and LEDs to program and visualize the state of the reclosing system. Remote indicators AUX and TRIP status outputs (voltage-free contacts). The AUX output is a NO contact, which closes when the auxiliary power supply is connected. The TRIP output is an alarm output. The EXT input (not insulated) enables the switch to be controlled remotely. Remote indicators Denotes protection trip RED LED Denotes normal operation GREEN LED Advantages and benefits 1 Status outputs for the main switch. When the switch is closed, contact 16-17 is closed. When switch is open, contact 16-18 is closed. 2 The auxiliary power supply is connected between terminals 1-3. The earth leakage transformer is connected between terminals 7-8. Bottom view Top view 1 2 The TeleREC Top is used to protect single and three-phase electrical installations (up to 63A), in which a high level of continuity in the electrical service must be guaranteed. The unit has an automatic rearming system which is activated following a trip, so that it reconnects itself after a certain amount of time, restoring the installations powersupply without the need for any human intervention. In short, the protection functions performed by the TeleREC Top are: Earth leakage protection (protects people against electric shock). Protection against overloads and short-circuits via a circuit breaker switch. 3

Reclosing system for Residual Current Circuit Breakers Automatic reclosing system Applications Series TeleREC 2 Performance EN 50557:2012 Approvals / Marking Thermal setting In (A) 25-100 Residual current (ma) 30, 300 Rated voltage AC Un (V) 2P: 230 4P: 230/400 Minimum operating voltage Ub min (V) 2P: 127 4P: 190 Mechanical/electrical endurance 20000/10000 Tropicalisation acc. to EN/IEC 60068-2 95%RH at 55 C Terminal capacity flexible/rigid cable (mm²) 25/35 Poles 2, 4 Nuisance tripping resistance (A) Type A: 250 Type Ai, S: 3000 Ambient temperature (ºC) -25 up to +55 Weight (g) 2P: 416 4P: 598 Short-circuit capacity Acc. to EN/IEC 61008-1 Making and breaking capacity Im = 500A Residual making and breaking capacity IΔm 500A from 16 up to 40A IΔm = 630A for 63A IΔm = 800 A from 80A to 100A Short-circuit capacity Inc = 10000A at 230/400V fuse 80A gg Reclosing system by insulation, M mode RECLOSURES 1 2 3 Delay Restart Delay Restart Delay Restart < 3 sec. 10 sec. 30 sec. 30 sec. 120 sec. 60 sec. The leakage current will be supervised by measuring the resistance downstream of the tripped RCCB. Dimensions Page 11 4

Series TeleREC 2 - RCCBs - Type A 30 ma 300 ma In (A) Cat. no. Ref. no. Cat. no. Ref. no. Pack 2P 25 REC2 A 225/30 676986 REC2 A 225/300 676994 1 40 REC2 A 240/30 676987 REC2 A 240/300 676995 1 63 REC2 A 263/30 676988 REC2 A 263/300 676996 1 80 REC2 A 280/30 676989 REC2 A 280/300 676997 1 100 REC2 A 2100/30 676990 REC2 A 2100/300 676998 1 5/6 N 6/5 N Aux. 4P 25 REC2 A 425/30 677042 REC2 A 425/300 677050 1 40 REC2 A 440/30 677043 REC2 A 440/300 677071 1 63 REC2 A 463/30 677044 REC2 A 463/300 677072 1 80 REC2 A 480/30 677045 REC2 A 480/300 677073 1 100 REC2 A 4100/30 677046 REC2 A 4100/300 677074 1 Series TeleREC 2 - RCCBs - Type Ai Series TeleREC 2 30 ma 300 ma In (A) Cat. no. Ref. no. Cat. no. Ref. no. Pack 2P 25 REC2 Ai 225/30 676991 - - 1 40 REC2 Ai 240/30 676992 - - 1 63 REC2 Ai 263/30 676993 - - 1 80 - - - - - 100 - - - - - 4P 25 REC2 Ai 425/30 677047 - - 1 40 REC2 Ai 440/30 677048 - - 1 63 REC2 Ai 463/30 677049 - - 1 80 - - - - - 100 - - - - - 5/6 N 6/5 N Aux. Series TeleREC 2 - RCCBs - Type S 30 ma 300 ma In (A) Cat. no. Ref. no. Cat. no. Ref. no. Pack 2P 25 - - - - - 40 - - REC2 S 240/300 676999 1 63 - - REC2 S 263/300 677039 1 80 - - REC2 S 280/300 677040 1 100 - - REC2 S 2100/300 677041 1 4P 25 - - - - - 40 - - REC2 S 440/300 677075 1 63 - - REC2 S 463/300 677076 1 80 - - REC2 S 480/300 677077 1 100 - - REC2 S 4100/300 677098 1 5/6 N 6/5 N Aux. 5

Reclosing system for 2P RCBOs - Residual Current Circuit Breakers with Overcurrent Protection Automatic reclosing system Applications Series TeleREC 2 Performance EN 50557:2012 Marking Thermal setting In (A) 10-40 Residual current (ma) 30, 300 Tripping characteristics B-C Rated voltage AC Un (V) 230 Minimum operating voltage Ub min (V) 150 Mechanical/electrical endurance 20000/10000 Tropicalisation acc. to EN/IEC 60068-2 95%RH at 55 C Terminal capacity flexible/rigid cable (mm²) 25/35 Poles 2 Nuisance tripping resistance (A) Type A: 250 Type Ai: 3000 Ambient temperature (ºC) -25 up to +55 Weight (g) 346 Short-circuit capacity Acc. to EN 61009-1 Residual Making and Breaking capacity IΔm=6000A Energy limiting class 3 Short-circuit capacity Icn=10000A at 230V Reclosing system by insulation, M mode RECLOSURES 1 2 3 Rec time Restart Rec time Restart Rec time Restart 3 60 240 240 960 960 The leakage current will be supervised by measuring the resistance downstream of the tripped RCBO. The ShortCircuit current will be supervised by measuring the resistance downstream of the tripped RCBO. Dimensions Page 11 6

Series TeleREC 2 - RCBOs - Type A - Characteristic C 30 ma 300 ma In (A) Cat. no. Ref. no. Cat. no. Ref. no. Pack 2P 10 REC2 DPCA100C10/030 677150 REC2 DPCA100C10/300 677156 1 16 REC2 DPCA100C16/030 677151 REC2 DPCA100C16/300 677157 1 20 REC2 DPCA100C20/030 677152 REC2 DPCA100C20/300 677158 1 25 REC2 DPCA100C25/030 677153 REC2 DPCA100C25/300 677159 1 32 REC2 DPCA100C32/030 677154 REC2 DPCA100C32/300 677160 1 40 REC2 DPCA100C40/030 677155 REC2 DPCA100C40/300 677161 1 Series TeleREC 2 - RCBOs - Type A - Characteristic B 30 ma 300 ma In (A) Cat. no. Ref. no. Cat. no. Ref. no. Pack 2P 10 REC2 DPCA100B10/030 677174 REC2 DPCA100B10/300 677180 1 16 REC2 DPCA100B16/030 677175 REC2 DPCA100B16/300 677181 1 20 REC2 DPCA100B20/030 677176 REC2 DPCA100B20/300 677182 1 25 REC2 DPCA100B25/030 677177 REC2 DPCA100B25/300 677183 1 32 REC2 DPCA100B32/030 677178 REC2 DPCA100B32/300 677184 1 40 REC2 DPCA100B40/030 677179 REC2 DPCA100B40/300 677185 1 Series TeleREC 2 Series TeleREC 2 - RCBOs - Type Ai - Characteristic C 30 ma 300 ma In (A) Cat. no. Ref. no. Cat. no. Ref. no. Pack 2P 10 REC2 DPCAi100C10/030 677162 REC2 DPCAi100C10/300 677168 1 16 REC2 DPCAi100C16/030 677163 REC2 DPCAi100C16/300 677169 1 20 REC2 DPCAi100C20/030 677164 REC2 DPCAi100C20/300 677170 1 25 REC2 DPCAi100C25/030 677165 REC2 DPCAi100C25/300 677171 1 32 REC2 DPCAi100C32/030 677166 REC2 DPCAi100C32/300 677172 1 40 REC2 DPCAi100C40/030 677167 REC2 DPCAi100C40/300 677173 1 Available second half of 2014. 7

Reclosing system with earth leakage protection for Miniature Circuit Breakers Automatic reclosing system Applications Series TeleREC Top - MCBs Performance Marking Thermal setting In (A) 6-63 Residual current adjustable 30mA 1A Tripping characteristics B-C Rated voltage AC Un (V) 230/400 Minimum operating voltage Ub min (V) 12 Selectivity class 3 Mechanical/electrical endurance 20000/10000 Tropicalisation acc. to EN/IEC 60068-2 95%RH at 55 C Terminal capacity flexible/rigid cable (mm²) 25/35 Poles 2, 4 Nuisance tripping resistance (A) Type A: 378 Ambient temperature (ºC) -10 up to +50 Weight (g) 2P: 516 4P: 769 Short-circuit capacity AC acc. to EN/IEC 60898-1 Poles V Icn/Ics (ka) 2-4 230/400 10 AC acc. to EN/IEC 60947-2 Poles V Icu (ka)(1) 2 127 40 230 30 Dimensions Page 11 2 415 15 4 240 30 415 15 Reclosing system Configuration of the reclosing system after a trip caused by overcurrent or short-circuit fault: maximum number of reclose attempts (NR), the timer (ST) and the resetting time of the partial meter (TR) can be configured. See manual configuration of the reclosing system following a trip caused by an earth leakage: maximum number of reclose attempts (NR), the timer (ST) and the resetting time of the partial meter (TR) can be configured. See manual. 8

Series TeleREC Top - MCBs - Characteristic C In (A) Cat. no. Ref. no. Pack 2P 6 - - - 4,5 mod. 10 REC TOP EP102 C10 677186 1 16 REC TOP EP102 C16 677187 1 20 REC TOP EP102 C20 677188 1 25 REC TOP EP102 C25 677189 1 32 REC TOP EP102 C32 677190 1 40 REC TOP EP102 C40 677191 1 50 REC TOP EP102 C50 677192 1 63 REC TOP EP102 C63 677193 1 4P 6 - - - 6,5 mod. 10 REC TOP EP104 C10 678028 1 16 REC TOP EP104 C16 678029 1 20 REC TOP EP104 C20 678030 1 25 REC TOP EP104 C25 678031 1 32 REC TOP EP104 C32 678032 1 40 REC TOP EP104 C40 678033 1 50 REC TOP EP104 C50 678034 1 63 REC TOP EP104 C63 678035 1 Series TeleREC Top Series TeleREC Top - MCBs - Characteristic B In (A) Cat. no. Ref. no. Pack 4P 6 - - - 6,5 mod. 10 REC TOP EP104 B10 677194 1 16 REC TOP EP104 B16 677195 1 20 REC TOP EP104 B20 677196 1 25 REC TOP EP104 B25 677197 1 32 REC TOP EP104 B32 677198 1 40 REC TOP EP104 B40 677199 1 50 REC TOP EP104 B50 678026 1 63 REC TOP EP104 B63 678027 1 Accessories Ø Cat. no. Ref. no. Pack Toroidal transformer for earth leakage detection 25 mm 2 REC TOP TT 25 678036 1 35 mm 2 REC TOP TT 35 678037 1 9

Reclosing system for Residual Current Circuit Breakers Automatic reclosing system Applications Series TeleREC Plus - for industrial applications The reconnection relay TeleREC can be easily coupled to any RCCB: Performance + = Marking Rated voltage AC Un (V) 220/400 Frequency (Hz) 50/60 Reclosing numbers 6 Reclosing cycles (sec) 10, 20, 30, 60, 120, 600 Auxiliary contact Imax 2A (250Vac or 24Vdc) Imin (auxiliary contact) (ma) 20 Remote control Manual reclosing with push-button Weight (g) 358 Series TeleREC Plus Cat. no. Ref. no. Pack 3 mod. Tele REC PLUS Motor 677132 1 Reclosing cycles RCCB Close Dimensions Page 11 Timer 1 2 3 4 5 6 10 20 30 60 2 10 10

Dimensions TeleREC 2 RCCB / RCBO 2P 4,5 mod. 79,5 82 76 44 6 TeleREC 2 RCBO 115 82 76 44 6 Series TeleREC TeleREC Top MCB 36 72 36 76 44 6 86 45 RESET TEST PROG 90 110 86 45 RESET TEST PROG 90 110 45 35,5 ON ON 79 114 82 TeleREC Plus 53 70 57,5 43 45 89 86 108 45 35,5 120 86 45 35,5 4P 6,5 mod. 2P 4,5 mod. 4P 6,5 mod. 3 mod. 76 11

By reference number By catalogue number Ref. No. Cat. No. Page 676000 676986 REC2 A 225/30 5 676987 REC2 A 240/30 5 676988 REC2 A 263/30 5 676989 REC2 A 280/30 5 676990 REC2 A 2100/30 5 676991 REC2 Ai 225/30 5 676992 REC2 Ai 240/30 5 676993 REC2 Ai 263/30 5 676994 REC2 A 225/300 5 676995 REC2 A 240/300 5 676996 REC2 A 263/300 5 676997 REC2 A 280/300 5 676998 REC2 A 2100/300 5 676999 REC2 S 240/300 5 677000 677039 REC2 S 263/300 5 677040 REC2 S 280/300 5 677041 REC2 S 2100/300 5 677042 REC2 A 425/30 5 677043 REC2 A 440/30 5 677044 REC2 A 463/30 5 677045 REC2 A 480/30 5 677046 REC2 A 4100/30 5 677047 REC2 Ai 425/30 5 677048 REC2 Ai 440/30 5 677049 REC2 Ai 463/30 5 677050 REC2 A 425/300 5 677071 REC2 A 440/300 5 677072 REC2 A 463/300 5 677073 REC2 A 480/300 5 677074 REC2 A 4100/300 5 677075 REC2 S 440/300 5 677076 REC2 S 463/300 5 677077 REC2 S 480/300 5 677098 REC2 S 4100/300 5 677132 Tele REC PLUS Motor 10 677150 REC2 DPCA100C10/030 7 677151 REC2 DPCA100C16/030 7 677152 REC2 DPCA100C20/030 7 677153 REC2 DPCA100C25/030 7 677154 REC2 DPCA100C32/030 7 677155 REC2 DPCA100C40/030 7 677156 REC2 DPCA100C10/300 7 677157 REC2 DPCA100C16/300 7 677158 REC2 DPCA100C20/300 7 677159 REC2 DPCA100C25/300 7 677160 REC2 DPCA100C32/300 7 677161 REC2 DPCA100C40/300 7 677162 REC2 DPCAi100C10/030 7 677163 REC2 DPCAi100C16/030 7 677164 REC2 DPCAi100C20/030 7 677165 REC2 DPCAi100C25/030 7 677166 REC2 DPCAi100C32/030 7 677167 REC2 DPCAi100C40/030 7 677168 REC2 DPCAi100C10/300 7 677169 REC2 DPCAi100C16/300 7 677170 REC2 DPCAi100C20/300 7 677171 REC2 DPCAi100C25/300 7 677172 REC2 DPCAi100C32/300 7 677173 REC2 DPCAi100C40/300 7 677174 REC2 DPCA100B10/030 7 677175 REC2 DPCA100B16/030 7 677176 REC2 DPCA100B20/030 7 677177 REC2 DPCA100B25/030 7 677178 REC2 DPCA100B32/030 7 677179 REC2 DPCA100B40/030 7 677180 REC2 DPCA100B10/300 7 677181 REC2 DPCA100B16/300 7 677182 REC2 DPCA100B20/300 7 677183 REC2 DPCA100B25/300 7 677184 REC2 DPCA100B32/300 7 677185 REC2 DPCA100B40/300 7 677186 REC TOP EP102 C10 9 677187 REC TOP EP102 C16 9 677188 REC TOP EP102 C20 9 677189 REC TOP EP102 C25 9 677190 REC TOP EP102 C32 9 677191 REC TOP EP102 C40 9 677192 REC TOP EP102 C50 9 677193 REC TOP EP102 C63 9 Ref. No. Cat. No. Page 677194 REC TOP EP104 B10 9 677195 REC TOP EP104 B16 9 677196 REC TOP EP104 B20 9 677197 REC TOP EP104 B25 9 677198 REC TOP EP104 B32 9 677199 REC TOP EP104 B40 9 678000 678026 REC TOP EP104 B50 9 678027 REC TOP EP104 B63 9 678028 REC TOP EP104 C10 9 678029 REC TOP EP104 C16 9 678030 REC TOP EP104 C20 9 678031 REC TOP EP104 C25 9 678032 REC TOP EP104 C32 9 678033 REC TOP EP104 C40 9 678034 REC TOP EP104 C50 9 678035 REC TOP EP104 C63 9 678036 REC TOP TT 25 9 678037 REC TOP TT 35 9 Cat. No. Ref. No. Page Cat. No. Ref. No. Page REC TOP EP104 C20 678030 9 REC TOP EP104 C25 678031 9 REC TOP EP104 C32 678032 9 REC TOP EP104 C40 678033 9 REC TOP EP104 C50 678034 9 REC TOP EP104 C63 678035 9 REC TOP EP104 B10 677194 9 REC TOP EP104 B16 677195 9 REC TOP EP104 B20 677196 9 REC TOP EP104 B25 677197 9 REC TOP EP104 B32 677198 9 REC TOP EP104 B40 677199 9 REC TOP EP104 B50 678026 9 REC TOP EP104 B63 678027 9 REC TOP TT 25 678036 9 REC TOP TT 35 678037 9 T Tele REC PLUS Motor 677132 10 Numerical index R REC2 A 225/30 676986 5 REC2 A 240/30 676987 5 REC2 A 263/30 676988 5 REC2 A 280/30 676989 5 REC2 A 2100/30 676990 5 REC2 A 425/30 677042 5 REC2 A 440/30 677043 5 REC2 A 463/30 677044 5 REC2 A 480/30 677045 5 REC2 A 4100/30 677046 5 REC2 Ai 225/30 676991 5 REC2 Ai 240/30 676992 5 REC2 Ai 263/30 676993 5 REC2 Ai 425/30 677047 5 REC2 Ai 440/30 677048 5 REC2 Ai 463/30 677049 5 REC2 S 240/300 676999 5 REC2 S 263/300 677039 5 REC2 S 280/300 677040 5 REC2 S 2100/300 677041 5 REC2 S 440/300 677075 5 REC2 S 463/300 677076 5 REC2 S 480/300 677077 5 REC2 S 4100/300 677098 5 REC2 A 225/300 676994 5 REC2 A 240/300 676995 5 REC2 A 263/300 676996 5 REC2 A 280/300 676997 5 REC2 A 2100/300 676998 5 REC2 A 425/300 677050 5 REC2 A 440/300 677071 5 REC2 A 463/300 677072 5 REC2 A 480/300 677073 5 REC2 A 4100/300 677074 5 REC2 DPCA100C10/030 677150 7 REC2 DPCA100C16/030 677151 7 REC2 DPCA100C20/030 677152 7 REC2 DPCA100C25/030 677153 7 REC2 DPCA100C32/030 677154 7 REC2 DPCA100C40/030 677155 7 REC2 DPCA100B10/030 677174 7 REC2 DPCA100B16/030 677175 7 REC2 DPCA100B20/030 677176 7 REC2 DPCA100B25/030 677177 7 REC2 DPCA100B32/030 677178 7 REC2 DPCA100B40/030 677179 7 REC2 DPCAi100C10/030 677162 7 REC2 DPCAi100C16/030 677163 7 REC2 DPCAi100C20/030 677164 7 REC2 DPCAi100C25/030 677165 7 REC2 DPCAi100C32/030 677166 7 REC2 DPCAi100C40/030 677167 7 REC2 DPCA100C10/300 677156 7 REC2 DPCA100C16/300 677157 7 REC2 DPCA100C20/300 677158 7 REC2 DPCA100C25/300 677159 7 REC2 DPCA100C32/300 677160 7 REC2 DPCA100C40/300 677161 7 REC2 DPCA100B10/300 677180 7 REC2 DPCA100B16/300 677181 7 REC2 DPCA100B20/300 677182 7 REC2 DPCA100B25/300 677183 7 REC2 DPCA100B32/300 677184 7 REC2 DPCA100B40/300 677185 7 REC2 DPCAi100C10/300 677168 7 REC2 DPCAi100C16/300 677169 7 REC2 DPCAi100C20/300 677170 7 REC2 DPCAi100C25/300 677171 7 REC2 DPCAi100C32/300 677172 7 REC2 DPCAi100C40/300 677173 7 REC TOP EP102 C10 677186 9 REC TOP EP102 C16 677187 9 REC TOP EP102 C20 677188 9 REC TOP EP102 C25 677189 9 REC TOP EP102 C32 677190 9 REC TOP EP102 C40 677191 9 REC TOP EP102 C50 677192 9 REC TOP EP102 C63 677193 9 REC TOP EP104 C10 678028 9 REC TOP EP104 C16 678029 9 The policy of GE is one of continuous improvement. The right is reserved to alter the design or any structural details of the products at any time without giving notice. May 2014 12

GE Industrial Solutions 111389 is a first class global supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. www.ge.com/ex/industrialsolutions www.ge.com/uk/industrialsolutions Belgium GE Industrial Belgium Nieuwevaart 51 B-9000 Gent Tel. +32 (0)9 265 21 11 Finland Kuortaneenkatu 2 FI-00510 Helsinki Tel. +358 (0)10 394 3760 France Paris Nord 2 13, rue de la Perdrix F-95958 Roissy CDG Cédex Tel. +33 (0)800 912 816 Germany Robert-Bosch Str. 2a D-50354 Hürth-Efferen Tel. +49 (0) 2233/ 9719-0 Hungary GE Hungary Kft. Vaci ut 81-83. H-1139 Budapest Tel. +36 1 447 6050 Italy Centro Direzionale Colleoni Via Paracelso 16 Palazzo Andromeda B1 I-20864 Agrate Brianza (MB) Tel. +39 039 637 371 Netherlands Parallelweg 10 Nl-7482 CA Haaksbergen Tel. +31 (0)53 573 03 03 Poland GE Power Controls Ul. Odrowaza 15 03-310 Warszawa Tel. +48 22 519 76 00 Ul. Leszczyńska 6 43-300 Bielsko-Biała Tel. +48 33 828 62 33 Russia 27/8, Electrozavodskaya street Moscow, 107023 Tel. +7 495 937 11 11 South Africa Unit 4, 130 Gazelle Avenue Corporate Park Midrand 1685 P.O. Box 76672 Wendywood 2144 Tel. +27 11 238 3000 Spain GE POWER CONTROLS IBÉRICA, S.L. Calle Miño 122 Naves E-F Polígono Industrial Santa Margarita 08223 Terrassa (Barcelona) Tel. +34 900 993 625 United Arab Emirates Injaz Building, 3rd Floor Dubai Internet City PO Box 11549, Dubai Tel. +971 4 4546912 United Kingdom 2 The Arena, Downshire Way Bracknell, Berkshire RG12 1PU Tel. +44 (0)800 587 1239 GE imagination at work 680816 Ref. R/2507/E/EX 1.0 Ed. 04/14 Copyright 2014