Model 593C 10 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 593C.18.9

Similar documents
Product Data. 38CMC (60 Hz) 11 SEER Air Conditioner. Sizes 018 thru 060

EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Product Data. Efficiency. S SEER/ EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Min. Circuit Ampacity. Max. Fuse or Breaker

Product Data. 38TUA (60 Hz) Air Conditioner. Quality Assurance. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 24ABB3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S S

Max. Fuse or Breaker. Shipping/Operating Weight lbs.(kg) R4H318AKA 1 1/2 18, /16 x 23 1/8 x 23 1/8 131 / 117 (59 / 53)

FORM NO. ATZ-221 Supersedes Form No. ATZ-210 AIR CONDITIONERS

EFFICIENT 13 SEER 3 -PHASE AIR CONDITIONER. Min. Circuit Ampacity

Product Data. Efficiency

AIR CONDITIONERS WA13 SERIES

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

MAINLINE AIR CONDITIONERS

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

MODEL: SA14. Air Conditioners. Sure Comfort SA14. Air Conditioners

TECHNICAL SUPPORT MANUAL Split System Air Conditioner (C,H,T)4A3

Ruud Achiever Series Air Conditioners

TECHNICAL SUPPORT MANUAL Split System Air Conditioner R2A3

T CLASS SPLIT SYSTEM UNITS High Efficiency - R-410A - 60 HZ

13 SEER CONDENSING UNITS

Rheem Classic Series. Air Conditioners

ENZX. EBARA Submersible Slurry Pump. Contents Project: Model: Chk d: Date:

Ruud Achiever Series Air Conditioners

Ruud Achiever Series Air Conditioners

Rheem Classic Series. Air Conditioners

A951A/S PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Ruud Achiever Series Air Conditioners

Downflow Conversion Kit used to Modify Air Handler Units for Downflow Application

Rheem Classic Series. Air Conditioners

TECHNICAL SUPPORT MANUAL Ducted Horizontal Air Conditioner HC4A3

TECHNICAL SUPPORT MANUAL Split System Heat Pump N4H3

4PXC. Cased Aluminum Dedicated Upflow / Downflow Coils Convertible to Horizontal with Kit PUB. NO

Ruud Achiever Series Air Conditioners

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Reciprocating Compressor Models. Rotary Compressor Models CONTENTS

SECTION MANUFACTURED GAS FIREPLACES

PARTS CATALOG ESPRESSO EP SYSTEM

POWERED BY NITRO COLD BREW COFFEE FULL EQUIPMENT LINE

Powder Booths GLOBAL FINISHING SOLUTIONS GLOBALFINISHING.COM GLOBAL FINISHING SOLUTIONS

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A3

alfresco enjoy the experience

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

BUILT IN DELUXE SPIT BRAAI MODELS: 1200 & 1500

E N T E R P R I S E S

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

Parts Catalog Espresso System

Surface-Mounted Thermostat ATH series

E N T E R P R I S E S

94306 Vertical Flame Arrester. Features. Vertical Flame Arrester. Unitized tube bank design

INSTALLATION AND WARRANTY CERTIFICATE. Machine model Serial Number # Rating and optional. Installation Company: Technician ID: Date: / /

2<

2018 CATALOG GAS DIRECT VENT FRAMELESS LINEAR MODERN

ATTIAS OVEN CORPORATION (COMMERCIAL BBQ ROTISSERIES)

Cutout Width 28 5/8 28 5/8 40 1/4 40 1/4 (72.7 cm) (72.7 cm) (102.2 cm) (102.2 cm)

Shotmeister Owner s Manual. The Sleekest Design, Pouring the Coldest Shots

Pneumatic Cylinders Cartridge Cylinders Series P1G

OWNER S MANUAL GRAVITY FEED MODELS FOR OUTDOOR USE ONLY WARNING DO NOT STORE OR USE COMBUSTIBLE MATERIALS NEAR THIS UNIT

NORTH / 2KG. Mill City Roasters, LLC rd Ave SE Minneapolis, MN 55414

NORTH / 1KG. Mill City Roasters, LLC rd Ave SE Minneapolis, MN 55414

ACME Fluid Systems. Strainer Selection Guidelines Web:

CMC DUO. Standard version. Table of contens

Vent-Free. Fireboxes. LogMate Vent-Free Gas Fireboxes Indoor / Outdoor. Premium Luxury Series. Performance Traditional Series

TEA CATER USER MANUAL. UM_EN Part No.:

Upflow Carbon Installation & Start-Up Guide

REVERSIBLE DOOR 1. LAMP SWITCH 2. CABINET 3. LEVELLING LEGS 4. WINE RACK 5. GLASS DOOR 6. CHROME SHELVES 7. INTERIOR LAMP 8.

INSTALLATION QUICK START GUIDE AND CHECKLIST ATTENTION!! DO NOT ATTEMPT A PARTIAL INSTALL.

INSTALLATION AND OPERATION MANUAL FOR GAS TILTING BRAISING PANS MODELS G30TB & G40TB

Eaton Filtration, LLC

POWERED BY COLD BREW NITRO COFFEE FULL EQUIPMENT LINE

The Design and Marketing of a 300 Kilogram Coffee Roaster

TRUSTED RELIABLE QUALITY

Contents. Planning the Best Location Preparing a Good Foundation Electrical Requirements Natural Gas Installation...

Outdoor Grills and Modules

Wega Mininova 2003 Installation Instructions

MAGNETIC HID BALLASTS Ballasts-to-Lamp Remote Mounting Distances

12 Bottle Dual Zone. Touchscreen INSTRUCTION MANUAL

BUILT IN ROTISSERIE BRAAI MODEL: 1000

Matic / THa. Operating instructions COFFEE BREWER. Mode d emploi MACHINE À CAFÉ. Gebrauchsanleitung KAFFEEBRÜHMASCHINE

SIMPLEX STRAINER MODEL 90

48-Bottle Dual Zone Silent Wine Refrigerator

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

MODELS SHOWN: BICM24CS BUILT-IN COFFEE MACHINE AND WDC30JP WARMING DRAWER

How to Build a Wine Cellar

Wine Cooler Frigorifero da sottobanco Refrigerateur a vin

Surface-Mounted Thermostat ATH series

NOTICE TO INSTALLER: Please leave this book with the machine. Table of Contents

TRUSTED RELIABLE QUALITY

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS ITGE HEAVY DUTY ELECTRIC GRIDDLES THERMOSTAT CONTROLLED

ZANOLLI. Pizza ovens. Spare parts for: Suitable for:

Gas FireBrick Inserts for Fireplaces

BLG-E ELECTRIC FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT INSTALLATION OPERATION MAINTENANCE

Chicken Rotisserie. Model LM-8A LM-12A LM-8M LM-12M Instruction Manual

MCS Ovens. Member of the

THE GR THER A AINF AINF A THER THE GR

User Guide WINE CELLAR. Contents I GB F. Installation, 2 Location and power connection Technical information D E P

Installation & Parts Manual 2" & 3" High Capacity Strainers For Class 1, Petroleum Applications

Special Lucalox. GE Lighting DATA SHEET. Description

Pellet Pro 12 & 18 Lengths Large 35lb Hopper Assembly Operation Manual

Transcription:

10 SEER AIR CONDITIONER Model 593C Sizes 018 thru 060 Model 593C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today. Standard SEER ratings of 10.0 can reach as high as 11.5 when combined with specific Bryant equipment. All models are listed with ARI, UL (U.S. and Canada), and CEC. FEATURES ELECTRICAL RANGE All units are offered in 208 230v single phase. WIDE RANGE OF SIZES Available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. WEATHER-PROTECTIVE CABINET Steel is galvanized and coated with a layer of zinc phosphate. A coat of modified polyester powder coating is then applied and baked-on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are ceramic coated for a longlasting, rust-resistant, quality appearance. HEAVY DUTY INLET GRILLE The DuraGuard coil protector, made of a coated steel wire grid with vertical 3/8 in. spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. TOTALLY ENCLOSED FAN MOTOR Means greater reliability under adverse weather conditions and dependable performance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. Then the motor was tested and qualified under extreme conditions to help ensure the greatest reliability. UNIT DESIGN Copper tube, enhanced aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump-style drain pan for easy removal of water, dirt, and leaves. BRYANT S AEROQUIET SYSTEM Extremely low operating sound is the result of special attention to the air moving through the outdoor unit, and a specially designed sound enclosure surrounding the compressor to eliminate sound transmission to the rest of the systems. APPLICATION VERSATILITY The 593C can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. EASY SERVICEABILITY One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. For improved serviceability, all models are equipped with a compressor terminal plug. COMPRESSOR PROTECTION Each model is protected with internal temperature- and current-sensitive overloads. An internal pressure relief valve provides high-pressure protection to the refrigerant system. LIMITED WARRANTY Standard 5-year warranty on all parts and 10-year parts only warranty on compressor. Form No. PDS 593C.18.9

AIR DISCHARGE L AIR IN 3/8" DIA. TIEDOWN KNOCKOUTS (2) PLACES C AIR DISCHARGE 2 1 /2" 1 9 /16" FIELD POWER SUPPLY CONN. 7 /8" DIA. HOLE WITH 1 1 /8" DIA. KNOCKOUT AND 1 3 /8" DIA. KNOCKOUT B AIR IN C L E D K FIELD CONTROL SUPPLY CONN 7/8" DIA. HOLE H DIA. VAPOR LINE CONN. 3/8" DIA. LIQUID LINE CONN. F G A ACCESS PANEL 4 3/16" 10 1 /2" M AIR DISCHARGE AIR IN J N 1 1 /4" 1 3 /4" NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 F, (UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125 F. 3. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY. A990 DIMENSIONS (IN.) UNIT UNIT DIMENSIONS MINIMUM MOUNTING SIZE SERIES A B C D E F G H K L M N PAD DIMENSIONS 018 E 23-13/16 22-1/2 26-3/16 4-1/8 7-1/8 13-13/16 18-3/8 5/8 12-1/2 15-1/2 10-1/2 2-3/8 22 x 26 024 E 23-13/16 22-1/2 26-3/16 4-1/8 7-1/8 13-13/16 18-3/8 5/8 12-1/2 15-1/2 10-1/2 2-3/8 22 x 26 030 E 27-13/16 22-1/2 26-3/16 4-1/8 7-1/8 15-15/16 22-3/8 3/4 12-1/2 15-1/2 11-1/2 2-3/8 22 x 26 036 E 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-15/16 28-3/8 3/4 12-1/2 15-1/2 13 2-3/8 22 x 26 042 E 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 7/8 15-1/2 18 12-5/16 2-15/16 28 x 31 048 D 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 7/8 15-1/2 18 13-1/2 2-15/16 28 x 31 060 D 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 15-1/2 18 16-1/2 2-15/16 28 x 31 2

RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) VAPOR TUBE DIAMETER (IN.) UNIT SIZE 0 to 50 Ft Tube Length Long-Line Applications* 0 to 50 Ft Tube Length Long-Line Applications* (Maximum Diameter) 018, 024 5/8 3/4 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets between 50 and 175 ft horizontal or 20 ft vertical differential, consult Residential Split Long-Line Application Guideline. CHECK-FLO-RATER PISTON PISTON* UNIT SIZE SERIES IDENTIFICATION NO. 018-E 52 024-E 57 030-E 65 036-E 73 042-E 78 048-D 82 060-D 93 * Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) PISTON* UNIT SIZE SERIES IDENTIFICATION NO. 018-E 20 024-E 20 030-E 20 036-E 20 042-E 20 048-D 20 060-D 15 MODEL NUMBER NOMENCLATURE 593C J X 018 000 A A AA Model No. 10 SEER Split Air Conditioner Electrical Supply J 208-230-1-60 Nominal 018 1.5 ton 042 3.5 ton 024 2 ton 048 4 ton 030 2.5 ton 060 5 ton 036 3 ton N/A Standard Series A Original Series B Second Series Common U.S.A. Only Heating Size UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. REGISTERED QUALITY SYSTEM 3

See notes on page 5. SPECIFICATIONS UNIT SIZE 018-E 024-E 030-E 036-E Operating Weight (Lb) 138 144 163 172 ELECTRICAL Volts Hertz Phase 208 230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 9.0 11.5 14.1 16.0 Locked Rotor Amps 48.0 60.0 73.0 82.0 Condenser Fan Motor Full Load Amps 0.5 0.5 0.8 1.4 Min Ampacity for Wire Sizing 11.7 14.9 18.4 21.4 Min Wire Size (75 C Copper) AWG 14 14 14 12 Min Wire Size (60 C Copper) AWG 14 14 14 12 Max Wire Length (Ft) (75 C Copper) 62 50 37 54 Max Wire Length (Ft) (60 C Copper) 66 53 39 57 Max Branch Circuit Fuse Size** 20 20 30 30 COMPRESSOR and REFRIGERANT Compressor Type Reciprocating Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lb) R-22 and 3.50 R-22 and 3.80 R-22 and 4.75 R-22 and 5.30 CONDENSER COIL and FAN Coil Face (Sq Ft) 7.27 7.27 8.72 10.89 Fins per In. Rows Circuits 20 1 1 25 1 1 20 1 2 20 1 2 Fan Motor HP, Type, and RPM 1/12 PSC and 1100 1/10 PSC and 1100 1/4 PSC and 1100 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 1700 1700 2000 2500 OPTIONAL EQUIPMENT Support Feet KSASF0101AAA Coastal Filter KAACF0701SML Time Delay Relay KAATD0601TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1001AAA Start Assist Capacitor/Relay Type KSAHS2001AAA KSAHS0901AAA KSAHS1901AAA Start Assist PTC Type KAACS0201PTC Sound Hood KSASH2001BRL TXV Kit (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB KAATX0501RPB TXV Kits (Hard Shutoff) KSATX0601HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) Evaporator Freeze Thermostat** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control** KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Low-Ambient Controller KSALA0401AAA Ball Bearing Fan Motor HC34GE232 (RCD) HC40GE232 (RCD) Thermidistat Control Programmable/ Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermostat, Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B Builder s Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATBBSEN01-B Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder s Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 4

SPECIFICATIONS Continued UNIT SIZE 042-E 048-D 060-D Operating Weight (Lb) 211 218 225 ELECTRICAL Volts Hertz Phase 208 230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 17.7 22.8 28.4 Locked Rotor Amps 105.0 131.0 144.0 Condenser Fan Motor Full Load Amps 1.4 1.4 1.4 Min Ampacity for Wire Sizing 23.5 28.6 36.9 Min Wire Size (75 C Copper) AWG 12 10 8 Min Wire Size (60 C Copper) AWG 12 10 8 Max Wire Length (Ft) (75 C Copper) 50 63 74 Max Wire Length (Ft) (60 C Copper) 52 78 Max Branch Circuit Fuse Size** 40 50 60 COMPRESSOR and REFRIGERANT Compressor Type Reciprocating Scroll Temperature and Current Protection Internal Line Break Internal Line Break and Dome Thermostat Refrigerant Type and Amount (Lb) R-22 and 5.50 R-22 and 7.00 R-22 and 8.75 CONDENSER COIL and FAN Coil Face (Sq Ft) 12.16 15.19 18.30 Fins per In. Rows Circuits 20 1 2 20 1 3 25 1 4 Fan Motor HP, Type, and RPM 1/4 PSC and 1100 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 3400 OPTIONAL EQUIPMENT Support Feet KSASF0101AAA Coastal Filter KAACF0801MED Time Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1001AAA KAACH1201AAA Start Assist Capacitor/Relay Type KSAHS2201AAA KSAHS1701AAA KSAHS1601AAA Start Assist PTC Type KAACS0201PTC Sound Hood KSASH1201COP KSASH2101COP TXV Kit (RPB) KAATX0501RPB KAATX0601RPB KAATX0701RPB TXV Kits (Hard Shutoff) KSATX0601HSO KSATX0701HSO KSATX1001HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8163S (RCD) Evaporator Freeze Thermostat** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control** KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Low-Ambient Controller KSALA0401AAA Ball Bearing Fan Motor HC40GE232 (RCD) Thermidistat Control Programmable/ Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermostat, Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B Builder s Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATBBSEN01-B Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder s Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 * Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75 C (140 or 1 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. ** Fan motor with ball bearings required. See Low-ambient controller Installation Instructions for application. NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. 5

DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings, which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when Motor Master Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for scroll compressors in the following applications: Long line Low ambient Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a "soft" boost to the compressor motor at each start up. Usage Guideline: Suggested when compressor power supply is marginal Suggested in reciprocating compressor applications with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Filter Drier Bi-Flow A device for removing contaminants from refrigerant circulating in an air conditioning system: single-direction flow. Usage Guideline: Suggested in all field-connected split-system air conditioners. 8. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 426 ± 10 psig and resets at 320 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. Usage Guideline: Suggested in installations exposed to "very dirty" outdoor air. Suggested in installations where condenser inlet air temperature exceeds 125 F (51.7 C). 9. Liquid-Line Solenoid Valve (LLS) This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration. NOTE: When LLS is used with reciprocating compressors, Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shut off TXV can be used instead of LLS in single flow air conditioner applications. See Long Line Application Guideline. 10. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F ( 17.8 C) when properly installed. Usage Guideline: A Low-Ambient Pressure Switch or Motor Master Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). 11. MotorMaster -Low-Ambient Controller A fan speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 12 C). Usage Guideline: A Motor Master Low-Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications. 12. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. The device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Bryant thermostats listed in this publication. 6

DESCRIPTION AND USAGE (continued) 13. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Usage Guideline: Suggested when unit is installed closer than 15 ft to quiet areas bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 14. Support Feet Four stick-on plastics feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; minimizes corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. In windy areas or where debris is normally circulating. Rooftop installations. 15. Thermostatic Expansion Valve (TXV) Single-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 16. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. USAGE GUIDELINE REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay MotorMaster Low-Ambient Controller or Low-Ambient Pressure Switch Yes Yes No Yes No No Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No * For tubing line sets greater than 50 ft horizontal and/or 20 ft vertical differential, refer to Residential Split-system Long-Line Application Guideline and Service Manual. Only when low-pressure switch is used. Required for low-ambient controller (full modulation feature) and MotorMaster Control only. No NOTE: Tested in accordance with ARI standard 270-95. (Not listed with ARI.) A-WTD. SOUND POWER (dba) Standard TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) Size-Series Rating 125 250 500 1000 2000 4000 8000 018-E 78 53.0 62.0 72.0 69.0 69.0 65.0 58.0 024-E 78 53.5 65.0 69.5 72.5 66.5 65.5 58.5 030-E 78 60.0 66.5 71.0 72.0 71.0 68.5 62.5 036-E 80 58.5 70.0 72.0 74.5 71.5 69.5 62.5 042-E 81 60.5 71.5 71.5 74.5 72.5 71.5 66.5 048-D 80 66.5 68.0 71.0 75.0 69.0 68.0 63.0 060-D 80 61.0.0 72.0 74.0 71.0 72.0.0 7

UNIT SIZE- SERIES 018-E 024-E See notes on page 17. INDOOR MODEL COMBINATION RATINGS* TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT 8 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV *CC5A/CD5AA018 17,200 NONE 10.00 10.00 9.45 CC5A/CD5AA024 17,800 NONE 10.00 10.00 9.65 CC5A/CD5AW024 17,800 NONE 10.00 10.00 9.65 CE3AA024 17,800 NONE 10.00 10.00 9.70 CF5AA024 17,800 NONE 10.00 10.00 9.65 CK3BA024 17,800 NONE 10.00 10.00 9.85 CK5A/CK5BA018 17,200 NONE 10.00 10.00 9.60 CK5A/CK5BA024 17,800 NONE 10.00 10.00 9.85 CK5A/CK5BW024 17,800 NONE 10.00 10.00 9.85 F(A,B)4BN(F,C)018 17,200 TDR 10.00 10.00 9.50 F(A,B)4BN(F,C)024 17,800 TDR 10.50 10.50 9.90 FC4CNF024 17,800 TDR&TXV 10.50 9.90 FF1DNA018 17,200 TDR 10.00 10.00 9.75 FF1DNA024 17,800 TDR 10.00 10.00 9.80 FF1DNE018 17,200 TDR&TXV 10.00 9.75 FF1DNE024 17,800 TDR&TXV 10.00 9.80 FK4DNF001 18,000 TDR&TXV 11.50 10.95 FK4DNF002 18,400 TDR&TXV 11.50 11.10 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 10.50 10.50 10.30 CC5A/CD5AA024 17,400 TDR 11.00 11.00 10.50 CC5A/CD5AW024 17,400 TDR 11.00 11.00 10.55 CE3AA024 17,400 TDR 11.00 11.00 10.55 CK3BA024 17,400 TDR 11.00 11.00 10.80 CK5A/CK5BA018 17,000 TDR 10.50 10.50 10.45 CK5A/CK5BA024 17,400 TDR 11.00 11.00 10.70 CK5A/CK5BW024 17,400 TDR 11.00 11.00 10.70 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 10.50 10.50 10.35 CC5A/CD5AA024 17,400 TDR 11.00 11.00 10.55 CC5A/CD5AW024 17,400 TDR 11.00 11.00 10.60 CE3AA024 17,400 TDR 11.00 11.00 10.60 CK3BA024 17,400 TDR 11.00 11.00 10.85 CK5A/CK5BA018 17,000 TDR 10.50 10.50 10.50 CK5A/CK5BA024 17,400 TDR 11.00 11.00 10.75 CK5A/CK5BW024 17,400 TDR 11.00 11.00 10.75 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CE3AA024 17,400 TDR 11.00 11.00 10.60 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 10.50 10.50 10.35 CC5A/CD5AA024 17,400 TDR 11.00 11.00 10.55 CC5A/CD5AW024 17,400 TDR 11.00 11.00 10.55 CE3AA024 17,400 TDR 11.00 11.00 10.60 CK3BA024 17,400 TDR 11.00 11.00 10.80 CK5A/CK5BA018 17,000 TDR 10.50 10.50 10.50 CK5A/CK5BA024 17,400 TDR 11.00 11.00 10.75 CK5A/CK5BW024 17,400 TDR 11.00 11.00 10.75 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,400 TDR 11.00 11.00 10.60 CE3AA024 17,400 TDR 11.00 11.00 10.60 CK3BA024 17,400 TDR 11.00 11.00 10.80 CK5A/CK5BW024 17,400 TDR 11.00 11.00 10.75 *CC5A/CD5AA024 23,000 NONE 10.00 10.00 9.10 CC5A/CD5AA030 23,000 NONE 10.00 10.00 9.10 CC5A/CD5AW024 23,000 NONE 10.00 10.00 9.10 CC5A/CD5AW030 23,000 NONE 10.00 10.00 9.10 CE3AA024 23,000 NONE 10.00 10.00 9.15 CE3AA030 23,400 NONE 10.00 10.00 9.25 CF5AA024 23,000 NONE 10.00 10.00 9.10 CK3BA024 23,000 NONE 10.00 10.00 9.20 CK3BA030 23,000 NONE 10.00 10.00 9.20 CK5A/CK5BA024 23,000 NONE 10.00 10.00 9.20 CK5A/CK5BA030 23,000 NONE 10.00 10.00 9.20 CK5A/CK5BW024 23,000 NONE 10.00 10.00 9.20 CK5A/CK5BW030 23,000 NONE 10.00 10.00 9.20 F(A,B)4BN(F,C)024 23,000 TDR 10.00 10.00 9.10 F(A,B)4BN(F,C)030 23,600 TDR 10.00 10.00 9.30 FC4CNF024 23,000 TDR&TXV 10.00 9.10 FC4CNF030 23,600 TDR&TXV 10.00 9.40 FF1DNA024 23,000 TDR 10.00 10.00 9.10 FF1DNA030 23,400 TDR 10.00 10.00 9.25 FF1DNE024 23,000 TDR&TXV 10.00 9.10 FF1DNE030 23,400 TDR&TXV 10.00 9.25 FG3AAA024 22,000 NONE 10.00 10.00 9.05 FK4DNF001 23,400 TDR&TXV 11.00 10.20 FK4DNF002 23,800 TDR&TXV 11.00 10.35 FK4DNF003 23,800 TDR&TXV 11.00 10.45 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,600 TDR 10.50 10.50 9.85 CC5A/CD5AA030 22,600 TDR 11.00 11.00 9.95 CC5A/CD5AW024 22,600 TDR 10.50 10.50 9.90 CC5A/CD5AW030 22,600 TDR 11.00 11.00 9.95 EER

UNIT SIZE- SERIES 024-E See notes on page 17. INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.05 CK3BA024 22,600 TDR 10.50 10.50 10.10 CK3BA030 22,600 TDR 11.00 11.00 10.05 CK5A/CK5BA024 22,600 TDR 10.50 10.50 9.95 CK5A/CK5BA030 23,200 TDR 11.00 11.00 10.00 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.00 CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.00 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,600 TDR 10.50 10.50 9.90 CC5A/CD5AA030 22,600 TDR 11.00 11.00 10.05 CC5A/CD5AW024 22,600 TDR 10.50 10.50 10.00 CC5A/CD5AW030 22,600 TDR 11.00 11.00 10.05 CE3AA024 22,600 TDR 10.50 10.50 9.95 CE3AA030 23,000 TDR 11.00 11.00 10.15 CK3BA024 22,600 TDR 10.50 10.50 10.15 CK3BA030 22,600 TDR 11.00 11.00 10.15 CK5A/CK5BA024 22,600 TDR 10.50 10.50 10.05 CK5A/CK5BA030 22,600 TDR 11.00 11.00 10.05 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.05 CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.10 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,600 TDR 10.50 10.50 9.95 CC5A/CD5AW030 22,600 TDR 11.00 11.00 10.00 CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.10 CK3BA024 22,600 TDR 10.50 10.50 10.10 CK3BA030 22,600 TDR 11.00 11.00 10.10 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.00 CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.05 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.10 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.10 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CE3AA024 22,600 TDR 10.50 10.50 9.85 CE3AA030 23,000 TDR 11.00 11.00 10.05 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,600 TDR 10.50 10.50 9.85 CC5A/CD5AA030 22,600 TDR 11.00 11.00 10.00 CC5A/CD5AW024 22,600 TDR 10.50 10.50 9.90 CC5A/CD5AW030 22,600 TDR 11.00 11.00 10.00 CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.10 CK3BA024 22,600 TDR 10.50 10.50 10.10 CK3BA030 22,600 TDR 11.00 11.00 10.10 CK5A/CK5BA024 22,600 TDR 10.50 10.50 10.00 CK5A/CK5BA030 22,600 TDR 11.00 11.00 10.00 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.00 CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.05 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,600 TDR 10.50 10.50 9.90 CC5A/CD5AW030 22,600 TDR 11.00 11.00 9.95 CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.05 CK3BA024 22,600 TDR 10.50 10.50 10.10 CK3BA030 22,600 TDR 11.00 11.00 10.05 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.00 CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.00 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,600 TDR 10.50 10.50 9.90 CC5A/CD5AW030 22,600 TDR 11.00 11.00 9.95 CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.05 CK3BA024 22,600 TDR 10.50 10.50 10.10 CK3BA030 22,600 TDR 11.00 11.00 10.05 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.00 CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.05 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW024 22,600 TDR 10.50 10.50 9.90 CC5A/CD5AW030 22,600 TDR 11.00 11.00 10.00 CE3AA024 22,600 TDR 10.50 10.50 9.90 CE3AA030 23,000 TDR 11.00 11.00 10.10 CK3BA024 22,600 TDR 10.50 10.50 10.10 CK3BA030 22,600 TDR 11.00 11.00 10.10 CK5A/CK5BW024 22,600 TDR 10.50 10.50 10.00 9 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER

UNIT SIZE- SERIES INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT CK5A/CK5BW030 22,600 TDR 11.00 11.00 10.05 024-E COILS + 355MAV060120 VARIABLE-SPEED FURNACE CE3AA024 22,600 TDR 10.50 10.50 9.85 CE3AA030 23,000 TDR 11.00 11.00 10.05 *CC5A/CD5AA030 28,600 NONE 10.00 10.00 9.15 CC5A/CD5AA036 29,400 NONE 10.50 10.50 9.40 CC5A/CD5AW030 28,600 NONE 10.00 10.00 9.15 CC5A/CD5AW036 29,400 NONE 10.50 10.50 9.40 CE3AA030 28,600 NONE 10.00 10.00 9.25 CE3AA036 29,200 NONE 10.00 10.00 9.30 CF5AA036 29,400 NONE 10.00 10.00 9.35 CK3BA030 28,600 NONE 10.00 10.00 9.20 CK3BA036 29,400 NONE 10.50 10.50 9.40 CK5A/CK5BA030 28,600 NONE 10.00 10.00 9.20 CK5A/CK5BA036 29,400 NONE 10.50 10.50 9.40 CK5A/CK5BT036 29,400 NONE 10.50 10.50 9.40 CK5A/CK5BW030 28,600 NONE 10.00 10.00 9.20 CK5A/CK5BW036 29,600 NONE 10.50 10.50 9.40 F(A,B)4BN(F,C)030 28,600 TDR 10.00 10.00 9.35 F(A,B)4BN(F,C)036 29,000 TDR 10.00 10.00 9.20 FC4CNF030 28,600 TDR&TXV 10.00 9.35 FC4CNF036 29,000 TDR&TXV 10.00 8.95 FF1DNA030 29,000 TDR 10.00 10.00 9.25 FF1DNE030 29,000 TDR&TXV 10.00 9.25 FK4DNF001 29,000 TDR&TXV 11.00 10.05 FK4DNF002 29,200 TDR&TXV 11.00 10.20 FK4DNF003 29,400 TDR&TXV 11.00 10.35 FK4DNF005 30,000 TDR&TXV 11.50 10.25 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,000 TDR 10.50 10.50 9.80 CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.05 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.80 CE3AA030 28,000 TDR 10.50 10.50 9.90 CE3AA036 28,800 TDR 11.00 11.00 9.95 CK3BA030 28,000 TDR 10.50 10.50 9.90 CK3BA036 29,000 TDR 11.00 11.00 10.05 CK5A/CK5BA030 28,000 TDR 10.50 10.50 9.80 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.05 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.05 CK5A/CK5BW030 28,000 TDR 10.50 10.50 9.85 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,000 TDR 10.50 10.50 9.90 030-E CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.15 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.90 CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.20 CE3AA030 28,000 TDR 10.50 10.50 10.00 CE3AA036 28,800 TDR 11.00 11.00 10.05 CK3BA030 28,000 TDR 10.50 10.50 10.00 CK3BA036 29,000 TDR 11.00 11.00 10.15 CK5A/CK5BA030 28,000 TDR 10.50 10.50 9.90 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.20 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.15 CK5A/CK5BW030 28,000 TDR 10.50 10.50 9.95 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.20 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.20 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.95 CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.20 CE3AA030 28,000 TDR 10.50 10.50 10.05 CE3AA036 28,800 TDR 11.00 11.00 10.10 CK3BA030 28,000 TDR 10.50 10.50 10.05 CK3BA036 29,000 TDR 11.00 11.00 10.20 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.20 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.20 CK5A/CK5BW030 28,000 TDR 10.50 10.50 10.00 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.25 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.20 CE3AA030 28,000 TDR 10.50 10.50 10.00 CE3AA036 28,800 TDR 11.00 11.00 10.05 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.20 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.25 CE3AA030 28,000 TDR 10.50 10.50 10.05 CE3AA036 28,800 TDR 11.00 11.00 10.10 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.25 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.05 CE3AA030 28,000 TDR 10.50 10.50 9.85 CE3AA036 28,800 TDR 11.00 11.00 9.95 See notes on page 17. 10 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER

UNIT SIZE- SERIES 030-E 036-E See notes on page 17. INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.10 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,000 TDR 10.50 10.50 9.80 CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.10 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.80 CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.10 CE3AA030 28,800 TDR 10.50 10.50 9.90 CE3AA036 28,800 TDR 11.00 11.00 9.95 CK3BA030 28,000 TDR 10.50 10.50 9.90 CK3BA036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BA030 28,000 TDR 10.50 10.50 9.80 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BW030 28,000 TDR 10.50 10.50 9.85 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.10 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.05 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.80 CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.10 CE3AA030 28,000 TDR 10.50 10.50 9.90 CE3AA036 28,800 TDR 11.00 11.00 9.95 CK3BA030 28,000 TDR 10.50 10.50 9.90 CK3BA036 29,000 TDR 11.00 11.00 10.05 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.05 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.05 CK5A/CK5BW030 28,000 TDR 10.50 10.50 9.85 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.10 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.05 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.80 CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.10 CE3AA030 28,000 TDR 10.50 10.50 9.90 CE3AA036 28,800 TDR 11.00 11.00 9.95 CK3BA030 28,000 TDR 10.50 10.50 9.90 CK3BA036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BW030 28,000 TDR 10.50 10.50 9.85 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.10 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,000 TDR 11.00 11.00 10.10 CC5A/CD5AW030 28,000 TDR 10.50 10.50 9.85 CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.15 CE3AA030 28,000 TDR 10.50 10.50 9.95 CE3AA036 28,800 TDR 11.00 11.00 10.00 CK3BA030 28,000 TDR 10.50 10.50 9.95 CK3BA036 29,000 TDR 11.00 11.00 10.15 CK5A/CK5BA036 29,000 TDR 11.00 11.00 10.10 CK5A/CK5BT036 29,000 TDR 11.00 11.00 10.15 CK5A/CK5BW030 28,000 TDR 10.50 10.50 9.90 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.15 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,000 TDR 11.00 11.00 10.15 CE3AA030 28,000 TDR 10.50 10.50 9.95 CE3AA036 28,800 TDR 11.00 11.00 10.05 CK5A/CK5BW036 29,000 TDR 11.00 11.00 10.15 *CC5A/CD5AA036 34,600 NONE 10.00 10.00 9.20 CC5A/CD5AA042 34,600 NONE 10.00 10.00 9.20 CC5A/CD5AW036 34,600 NONE 10.00 10.00 9.20 CC5A/CD5AW042 34,000 NONE 10.00 10.00 9.10 CE3AA036 34,000 NONE 10.00 10.00 9.10 CE3AA042 34,600 NONE 10.00 10.00 9.25 CF5AA036 34,400 NONE 10.00 10.00 9.15 CK3BA036 34,600 NONE 10.00 10.00 9.20 CK3BA042 34,600 NONE 10.00 10.00 9.20 CK5A/CK5BA036 34,600 NONE 10.00 10.00 9.20 CK5A/CK5BA042 34,600 NONE 10.00 10.00 9.20 CK5A/CK5BE042 34,600 NONE 10.00 10.00 9.25 CK5A/CK5BT036 34,600 NONE 10.00 10.00 9.20 CK5A/CK5BT042 34,600 NONE 10.00 10.00 9.20 CK5A/CK5BW036 34,600 NONE 10.00 10.00 9.20 F(A,B)4BN(F,B,C)042 34,600 TDR 10.00 10.00 9.15 F(A,B)4BN(F,C)036 34,000 TDR 10.00 10.00 8.95 FC4CN(F,B)042 34,600 TDR&TXV 10.00 9.15 FC4CNF036 34,000 TDR&TXV 10.00 8.95 FG3AAA036 33,600 NONE 10.00 10.00 9.05 FK4DNB006 36,000 TDR&TXV 11.50 10.55 FK4DNF001 34,000 TDR&TXV 10.50 9.65 FK4DNF002 34,000 TDR&TXV 11.00 9.55 FK4DNF003 34,600 TDR&TXV 11.00 10.05 FK4DNF005 35,000 TDR&TXV 11.50 10.10 11 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER

UNIT SIZE- SERIES INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 11.00 11.00 9.70 CE3AA036 33,200 TDR 10.50 10.50 9.60 CE3AA042 34,000 TDR 11.00 11.00 9.75 CK3BA036 33,800 TDR 11.00 11.00 9.70 CK5A/CK5BA036 33,800 TDR 11.00 11.00 9.70 CK5A/CK5BE042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BT036 33,800 TDR 11.00 11.00 9.70 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 11.00 11.00 9.85 CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.90 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.85 CE3AA036 33,200 TDR 10.50 10.50 9.70 CE3AA042 34,000 TDR 11.00 11.00 9.90 CK3BA036 33,800 TDR 11.00 11.00 9.85 CK3BA042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BA036 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.90 CK5A/CK5BE042 33,800 TDR 11.00 11.00 9.95 CK5A/CK5BT036 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.90 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.85 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 11.00 11.00 9.90 CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.95 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.95 CC5A/CD5AW042 33,200 TDR 11.00 11.00 9.90 CE3AA036 33,200 TDR 10.50 10.50 9.80 CK3BA036 33,800 TDR 11.00 11.00 9.90 CK3BA042 33,800 TDR 11.00 11.00 9.95 CK5A/CK5BA036 33,800 TDR 11.00 11.00 9.90 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.95 CK5A/CK5BE042 33,800 TDR 11.00 11.00 10.00 CK5A/CK5BT036 33,800 TDR 11.00 11.00 9.90 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.95 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.95 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.95 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.90 036-E CC5A/CD5AW042 CK3BA042 33,200 33,800 TDR TDR 11.00 11.00 11.00 11.00 9.90 9.90 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.90 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.90 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.90 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,800 TDR 11.00 11.00 10.00 CC5A/CD5AW036 33,800 TDR 11.00 11.00 10.00 CC5A/CD5AW042 33,200 TDR 11.00 11.00 9.95 CK3BA042 33,800 TDR 11.00 11.00 10.00 CK5A/CK5BA042 33,800 TDR 11.00 11.00 10.00 CK5A/CK5BT042 33,800 TDR 11.00 11.00 10.00 CK5A/CK5BW036 33,800 TDR 11.00 11.00 10.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.70 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.70 CC5A/CD5AW042 33,200 TDR 10.50 10.50 9.65 CE3AA036 33,200 TDR 10.50 10.50 9.55 CE3AA042 34,000 TDR 10.50 10.50 9.70 CK3BA042 33,800 TDR 11.00 11.00 9.70 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.70 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.70 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.70 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 11.00 11.00 9.75 CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.80 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.80 CE3AA036 33,200 TDR 10.50 10.50 9.65 CE3AA042 34,000 TDR 11.00 11.00 9.85 CK3BA036 33,800 TDR 11.00 11.00 9.75 CK3BA042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BA036 33,800 TDR 11.00 11.00 9.75 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BE042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BT036 33,800 TDR 11.00 11.00 9.75 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.80 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 10.50 10.50 9.60 CC5A/CD5AA042 33,800 TDR 10.50 10.50 9.65 CC5A/CD5AW036 33,800 TDR 10.50 10.50 9.65 See notes on page 17. 12 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER

UNIT SIZE- SERIES INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT CC5A/CD5AW042 33,200 TDR 10.50 10.50 9.60 CE3AA036 33,200 TDR 10.50 10.50 9.50 CE3AA042 34,000 TDR 11.00 11.00 9.70 CK3BA036 33,800 TDR 10.50 10.50 9.60 CK3BA042 33,800 TDR 10.50 10.50 9.65 CK5A/CK5BA036 33,800 TDR 10.50 10.50 9.60 CK5A/CK5BA042 33,800 TDR 10.50 10.50 9.65 CK5A/CK5BE042 33,800 TDR 10.50 10.50 9.70 CK5A/CK5BT036 33,800 TDR 10.50 10.50 9.60 CK5A/CK5BT042 33,800 TDR 10.50 10.50 9.65 CK5A/CK5BW036 33,800 TDR 10.50 10.50 9.65 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 11.00 11.00 9.75 CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.80 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.75 CC5A/CD5AW042 33,200 TDR 10.50 10.50 9.70 CE3AA036 33,200 TDR 10.50 10.50 9.65 CE3AA042 34,000 TDR 11.00 11.00 9.80 CK3BA036 33,800 TDR 11.00 11.00 9.75 CK3BA042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BA036 33,800 TDR 11.00 11.00 9.75 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BE042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BT036 33,800 TDR 11.00 11.00 9.75 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.80 036-E CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.80 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 33,800 TDR 11.00 11.00 9.75 CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.80 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.80 CC5A/CD5AW042 33,200 TDR 10.50 10.50 9.75 CE3AA036 33,200 TDR 10.50 10.50 9.65 CE3AA042 34,000 TDR 11.00 11.00 9.85 CK3BA036 33,800 TDR 11.00 11.00 9.80 CK3BA042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BA036 33,800 TDR 11.00 11.00 9.75 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BE042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BT036 33,800 TDR 11.00 11.00 9.75 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.80 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.80 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,800 TDR 11.00 11.00 9.85 CC5A/CD5AW036 33,800 TDR 11.00 11.00 9.85 CC5A/CD5AW042 33,200 TDR 10.50 10.50 9.80 CE3AA036 33,200 TDR 10.50 10.50 9.70 CE3AA042 34,000 TDR 11.00 11.00 9.85 CK3BA042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BA042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BT042 33,800 TDR 11.00 11.00 9.85 CK5A/CK5BW036 33,800 TDR 11.00 11.00 9.85 *CC5A/CD5AA042 40,000 NONE 10.00 10.00 9.25 CC5A/CD5AC048 39,500 NONE 10.00 10.00 9.15 CC5A/CD5AW042 39,500 NONE 10.00 10.00 9.15 CC5A/CD5AW048 40,000 NONE 10.00 10.00 9.25 CD5AA048 40,000 NONE 10.00 10.00 9.25 CE3AA042 40,000 NONE 10.00 10.00 9.30 CE3AA048 40,500 NONE 10.00 10.00 9.30 CF5AA048 40,000 NONE 10.00 10.00 9.25 CK3BA042 40,000 NONE 10.00 10.00 9.25 CK3BA048 40,500 NONE 10.00 10.00 9.30 CK5A/CK5BA042 40,000 NONE 10.00 10.00 9.25 CK5A/CK5BA048 40,500 NONE 10.00 10.00 9.30 CK5A/CK5BE042 40,000 NONE 10.00 10.00 9.30 CK5A/CK5BT042 40,000 NONE 10.00 10.00 9.25 CK5A/CK5BT048 40,500 NONE 10.00 10.00 9.30 042-E CK5A/CK5BW048 40,500 NONE 10.00 10.00 9.30 F(A,B)4BN(F,B,C)042 40,000 TDR 10.00 10.00 9.15 F(A,B)4BN(F,B,C)048 40,500 TDR 10.00 10.00 9.25 FC4CN(F,B)042 40,000 TDR&TXV 10.00 9.15 FC4CN(F,B)048 40,500 TDR&TXV 10.00 9.05 FC4CNB054 41,500 TDR&TXV 10.50 9.75 FK4DNB006 42,000 TDR&TXV 11.50 10.50 FK4DNF003 40,000 TDR&TXV 11.00 9.95 FK4DNF005 41,000 TDR&TXV 11.00 10.20 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CE3AA042 39,000 TDR 10.50 10.50 9.60 CE3AA048 39,500 TDR 10.50 10.50 9.65 CK5A/CK5BE042 39,000 TDR 10.50 10.50 9.60 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.80 See notes on page 17. 13 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER

UNIT SIZE- SERIES INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING BRYANT GAS FURNACE OR TDR CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.70 CD5AA048 39,000 TDR 11.00 11.00 9.85 CE3AA042 39,000 TDR 11.00 11.00 9.85 CE3AA048 39,500 TDR 11.00 11.00 9.85 CK3BA042 39,000 TDR 10.50 10.50 9.80 CK3BA048 39,500 TDR 11.00 11.00 9.90 CK5A/CK5BA042 39,000 TDR 10.50 10.50 9.75 CK5A/CK5BA048 39,500 TDR 11.00 11.00 9.90 CK5A/CK5BE042 39,000 TDR 11.00 11.00 9.80 CK5A/CK5BT042 39,000 TDR 10.50 10.50 9.75 CK5A/CK5BT048 39,500 TDR 11.00 11.00 9.90 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.85 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.80 CC5A/CD5AW042 38,500 TDR 10.50 10.50 9.80 CC5A/CD5AW048 39,000 TDR 11.00 11.00 9.95 CD5AA048 39,000 TDR 11.00 11.00 9.95 CE3AA042 39,000 TDR 11.00 11.00 9.90 CE3AA048 39,500 TDR 11.00 11.00 9.95 CK3BA042 39,000 TDR 11.00 11.00 9.85 CK3BA048 39,500 TDR 11.00 11.00 9.95 CK5A/CK5BA042 39,000 TDR 11.00 11.00 9.85 CK5A/CK5BA048 39,500 TDR 11.00 11.00 9.95 CK5A/CK5BE042 39,000 TDR 11.00 11.00 9.90 CK5A/CK5BT042 39,000 TDR 11.00 11.00 9.85 CK5A/CK5BT048 39,500 TDR 11.00 11.00 9.95 CK5A/CK5BW048 39,500 TDR 11.00 11.00 10.00 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.90 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.80 CC5A/CD5AW042 38,500 TDR 10.50 10.50 9.85 CC5A/CD5AW048 39,000 TDR 11.00 11.00 10.00 CD5AA048 39,000 TDR 11.00 11.00 10.00 CE3AA042 39,000 TDR 11.00 11.00 9.95 CE3AA048 39,500 TDR 11.00 11.00 10.00 CK3BA042 39,000 TDR 11.00 11.00 9.85 CK3BA048 39,500 TDR 11.00 11.00 10.00 CK5A/CK5BA042 39,000 TDR 11.00 11.00 9.85 CK5A/CK5BA048 39,500 TDR 11.00 11.00 10.00 CK5A/CK5BT042 39,000 TDR 11.00 11.00 9.85 042-E CK5A/CK5BT048 CK5A/CK5BW048 39,500 39,500 TDR TDR 11.00 11.00 11.00 11.00 10.00 10.05 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.60 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.50 CC5A/CD5AW042 38,500 TDR 10.50 10.50 9.55 CC5A/CD5AW048 39,000 TDR 10.50 10.50 9.70 CD5AA048 39,000 TDR 10.50 10.50 9.65 CE3AA042 39,000 TDR 10.50 10.50 9.65 CE3AA048 39,500 TDR 10.50 10.50 9.65 CK3BA042 39,000 TDR 10.50 10.50 9.60 CK3BA048 39,500 TDR 10.50 10.50 9.70 CK5A/CK5BA042 39,000 TDR 10.50 10.50 9.55 CK5A/CK5BA048 39,500 TDR 10.50 10.50 9.70 CK5A/CK5BT042 39,000 TDR 10.50 10.50 9.55 CK5A/CK5BT048 39,500 TDR 10.50 10.50 9.70 CK5A/CK5BW048 39,500 TDR 10.50 10.50 9.75 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.70 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.60 CD5AA048 39,000 TDR 10.50 10.50 9.75 CE3AA042 39,500 TDR 10.50 10.50 9.75 CE3AA048 39,500 TDR 10.50 10.50 9.75 CK3BA042 39,000 TDR 10.50 10.50 9.70 CK3BA048 39,500 TDR 10.50 10.50 9.80 CK5A/CK5BA042 39,000 TDR 10.50 10.50 9.70 CK5A/CK5BA048 39,500 TDR 10.50 10.50 9.80 CK5A/CK5BE042 39,000 TDR 10.50 10.50 9.70 CK5A/CK5BT042 39,000 TDR 10.50 10.50 9.70 CK5A/CK5BT048 39,500 TDR 10.50 10.50 9.80 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.55 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.50 CC5A/CD5AW042 38,500 TDR 10.50 10.50 9.50 CC5A/CD5AW048 39,000 TDR 10.50 10.50 9.65 CD5AA048 39,000 TDR 10.50 10.50 9.65 CE3AA042 39,000 TDR 10.50 10.50 9.60 CE3AA048 39,500 TDR 10.50 10.50 9.65 CK3BA042 39,000 TDR 10.50 10.50 9.55 CK3BA048 39,500 TDR 10.50 10.50 9.65 CK5A/CK5BA042 39,000 TDR 10.50 10.50 9.55 See notes on page 17. SEER TXV EER 14

UNIT SIZE- SERIES INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT CK5A/CK5BA048 39,500 TDR 10.50 10.50 9.65 CK5A/CK5BE042 39,000 TDR 10.50 10.50 9.60 CK5A/CK5BT042 39,000 TDR 10.50 10.50 9.55 CK5A/CK5BT048 39,500 TDR 10.50 10.50 9.65 CK5A/CK5BW048 39,500 TDR 10.50 10.50 9.70 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.65 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.60 CC5A/CD5AW042 38,500 TDR 10.50 10.50 9.60 CC5A/CD5AW048 39,000 TDR 10.50 10.50 9.75 CD5AA048 39,000 TDR 10.50 10.50 9.70 CE3AA042 39,000 TDR 10.50 10.50 9.70 CE3AA048 39,500 TDR 10.50 10.50 9.75 CK3BA042 39,000 TDR 10.50 10.50 9.65 CK3BA048 39,500 TDR 10.50 10.50 9.75 CK5A/CK5BA042 39,000 TDR 10.50 10.50 9.65 CK5A/CK5BA048 39,500 TDR 10.50 10.50 9.75 042-E CK5A/CK5BE042 CK5A/CK5BT042 39,000 39,000 TDR TDR 10.50 10.50 10.50 10.50 9.70 9.65 CK5A/CK5BT048 39,500 TDR 10.50 10.50 9.75 CK5A/CK5BW048 39,500 TDR 10.50 10.50 9.80 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 39,000 TDR 10.50 10.50 9.70 CC5A/CD5AC048 38,500 TDR 10.50 10.50 9.60 CC5A/CD5AW042 38,500 TDR 10.50 10.50 9.70 CC5A/CD5AW048 39,000 TDR 10.50 10.50 9.80 CD5AA048 39,000 TDR 10.50 10.50 9.80 CE3AA042 39,000 TDR 10.50 10.50 9.75 CE3AA048 39,500 TDR 10.50 10.50 9.80 CK3BA042 39,000 TDR 10.50 10.50 9.70 CK3BA048 39,500 TDR 10.50 10.50 9.85 CK5A/CK5BA042 39,000 TDR 10.50 10.50 9.70 CK5A/CK5BA048 39,500 TDR 10.50 10.50 9.80 CK5A/CK5BE042 39,000 TDR 10.50 10.50 9.75 CK5A/CK5BT042 39,000 TDR 10.50 10.50 9.70 CK5A/CK5BT048 39,500 TDR 10.50 10.50 9.80 CK5A/CK5BW048 39,500 TDR 10.50 10.50 9.90 *CD5AA048 46,000 NONE 10.00 10.00 9.30 CC5A/CD5AA060 46,500 NONE 10.50 10.50 9.30 CC5A/CD5AC048 45,000 NONE 10.00 10.00 9.25 CC5A/CD5AW048 46,000 NONE 10.00 10.00 9.30 CC5A/CD5AW060 47,000 NONE 10.50 10.50 9.50 CE3AA048 46,500 NONE 10.00 10.00 9.40 CE3AA060 47,000 NONE 10.50 10.50 9.50 CF5AA048 46,000 NONE 10.00 10.00 9.35 CK3BA048 46,000 NONE 10.00 10.00 9.30 CK3BA060 47,000 NONE 10.50 10.50 9.50 CK5A/CK5BA048 46,500 NONE 10.00 10.00 9.30 CK5A/CK5BA060 47,000 NONE 10.50 10.50 9.50 CK5A/CK5BT048 46,500 NONE 10.00 10.00 9.30 CK5A/CK5BT060 47,000 NONE 10.50 10.50 9.50 CK5A/CK5BW048 46,500 NONE 10.00 10.00 9.35 CK5A/CK5BX060 47,500 NONE 10.50 10.50 9.60 F(A,B)4BN(F,B,C)048 46,500 TDR 10.00 10.00 9.25 F(A,B)4BN(F,B,C)060 47,500 TDR 10.50 10.50 9.30 FB4BNB070 48,000 TDR 10.50 10.50 9.55 FC4CN(F,B)048 46,500 TDR&TXV 10.00 9.25 FC4CN(F,B)060 47,500 TDR&TXV 10.50 9.30 FC4CNB054 48,000 TDR&TXV 10.50 9.65 048-D FC4CNB070 FG3AAA048 48,000 46,000 TDR&TXV NONE 10.50 10.00 10.00 9.60 9.25 FK4DNB006 48,000 TDR&TXV 11.50 10.40 FK4DNF005 47,500 TDR&TXV 11.00 10.20 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.50 CD5AA048 45,000 TDR 10.50 10.50 9.60 CE3AA048 45,000 TDR 10.50 10.50 9.65 CE3AA060 46,000 TDR 11.00 11.00 9.85 CK3BA048 45,000 TDR 10.50 10.50 9.65 CK5A/CK5BA048 45,000 TDR 10.50 10.50 9.65 CK5A/CK5BT048 45,000 TDR 10.50 10.50 9.65 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 11.00 11.00 9.80 CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.65 CC5A/CD5AW048 45,000 TDR 11.00 11.00 9.80 CD5AA048 45,000 TDR 11.00 11.00 9.80 CE3AA048 45,000 TDR 11.00 11.00 9.80 CE3AA060 46,000 TDR 11.00 11.00 10.05 CK3BA048 45,000 TDR 11.00 11.00 9.80 CK3BA060 46,000 TDR 11.00 11.00 10.05 CK5A/CK5BA048 45,000 TDR 11.00 11.00 9.80 CK5A/CK5BA060 46,000 TDR 11.00 11.00 10.05 See notes on page 17. 15 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER

UNIT SIZE- SERIES INDOOR MODEL COMBINATION RATINGS CONTINUED TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT CK5A/CK5BT048 45,000 TDR 11.00 11.00 9.80 CK5A/CK5BT060 46,000 TDR 11.00 11.00 10.05 CK5A/CK5BW048 45,000 TDR 11.00 11.00 9.90 CK5A/CK5BX060 47,000 TDR 11.00 11.00 10.15 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 11.00 11.00 9.80 CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.60 CC5A/CD5AW048 45,000 TDR 11.00 11.00 9.80 CD5AA048 45,000 TDR 11.00 11.00 9.75 CE3AA048 45,000 TDR 11.00 11.00 9.75 CE3AA060 46,000 TDR 11.00 11.00 10.00 CK3BA048 45,000 TDR 11.00 11.00 9.80 CK3BA060 46,000 TDR 11.00 11.00 10.05 CK5A/CK5BA048 45,000 TDR 11.00 11.00 9.80 CK5A/CK5BA060 46,000 TDR 11.00 11.00 10.05 CK5A/CK5BT048 45,000 TDR 11.00 11.00 9.80 CK5A/CK5BT060 46,000 TDR 11.00 11.00 10.05 CK5A/CK5BW048 45,000 TDR 11.00 11.00 9.85 CK5A/CK5BX060 47,000 TDR 11.00 11.00 10.15 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 11.00 11.00 9.90 CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.70 CC5A/CD5AW048 45,000 TDR 11.00 11.00 9.85 CD5AA048 45,000 TDR 11.00 11.00 9.85 CE3AA048 45,000 TDR 11.00 11.00 9.85 CE3AA060 46,000 TDR 11.00 11.00 10.10 CK3BA048 45,000 TDR 11.00 11.00 9.90 CK3BA060 46,000 TDR 11.00 11.00 10.10 CK5A/CK5BA048 45,000 TDR 11.00 11.00 9.85 CK5A/CK5BA060 46,000 TDR 11.00 11.00 10.10 CK5A/CK5BT048 45,000 TDR 11.00 11.00 9.85 CK5A/CK5BT060 46,000 TDR 11.00 11.00 10.10 CK5A/CK5BW048 45,000 TDR 11.00 11.00 9.95 CK5A/CK5BX060 47,000 TDR 11.00 11.00 10.20 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 10.50 10.50 9.55 CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.40 CC5A/CD5AW048 45,000 TDR 10.50 10.50 9.55 048-D CD5AA048 CE3AA048 45,000 45,000 TDR TDR 10.50 10.50 10.50 10.50 9.50 9.55 CE3AA060 46,000 TDR 10.50 10.50 9.75 CK3BA048 45,000 TDR 10.50 10.50 9.55 CK3BA060 46,000 TDR 11.00 11.00 9.80 CK5A/CK5BA048 45,000 TDR 10.50 10.50 9.55 CK5A/CK5BA060 46,000 TDR 11.00 11.00 9.80 CK5A/CK5BT048 45,000 TDR 10.50 10.50 9.55 CK5A/CK5BT060 46,000 TDR 11.00 11.00 9.80 CK5A/CK5BW048 45,000 TDR 10.50 10.50 9.60 CK5A/CK5BX060 47,000 TDR 11.00 11.00 9.85 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 10.50 10.50 9.60 CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.45 CC5A/CD5AW048 45,000 TDR 10.50 10.50 9.60 CD5AA048 45,000 TDR 10.50 10.50 9.60 CE3AA048 45,000 TDR 10.50 10.50 9.60 CE3AA060 46,000 TDR 10.50 10.50 9.85 CK3BA048 45,000 TDR 10.50 10.50 9.60 CK3BA060 46,000 TDR 11.00 11.00 9.85 CK5A/CK5BA048 45,000 TDR 10.50 10.50 9.60 CK5A/CK5BA060 46,000 TDR 11.00 11.00 9.85 CK5A/CK5BT048 45,000 TDR 10.50 10.50 9.60 CK5A/CK5BT060 46,000 TDR 11.00 11.00 9.85 CK5A/CK5BW048 45,000 TDR 10.50 10.50 9.65 CK5A/CK5BX060 47,000 TDR 11.00 11.00 9.90 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 10.50 10.50 9.65 CC5A/CD5AC048 44,500 TDR 10.50 10.50 9.45 CC5A/CD5AW048 45,000 TDR 10.50 10.50 9.60 CD5AA048 45,000 TDR 10.50 10.50 9.60 CE3AA048 45,000 TDR 10.50 10.50 9.65 CE3AA060 46,000 TDR 10.50 10.50 9.85 CK3BA048 45,000 TDR 10.50 10.50 9.65 CK3BA060 46,000 TDR 11.00 11.00 9.85 CK5A/CK5BA048 45,000 TDR 10.50 10.50 9.65 CK5A/CK5BA060 46,000 TDR 11.00 11.00 9.85 CK5A/CK5BT048 45,000 TDR 10.50 10.50 9.65 CK5A/CK5BT060 46,000 TDR 11.00 11.00 9.85 CK5A/CK5BW048 45,000 TDR 10.50 10.50 9.70 CK5A/CK5BX060 47,000 TDR 11.00 11.00 9.95 *CC5A/CD5AW060 58,000 NONE 10.00 10.00 8.95 060-D CC5A/CD5AA060 CE3AA060 55,000 58,000 NONE NONE 10.00 10.00 10.00 10.00 8.80 9.05 CK3BA060 57,000 NONE 10.00 10.00 8.90 See notes on page 17. 16 STANDARD RATING BRYANT GAS FURNACE OR TDR SEER TXV EER