Programming Guide For EXTRACTOR Coffee Brewers (CBS 2000e Series)

Similar documents
NOTICE TO INSTALLER: Please leave this book with the machine. Table of Contents

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

(cont.) NOTE: Changing the UNIT settings will restore ALL settings to Factory Default.

TRUSTED RELIABLE QUALITY

TRUSTED RELIABLE QUALITY

User guide supplement. Built-in oven NZ AU. Soft Touch electronic models

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

Equipment Yield Chart

DUAL TF DBC SINGLE TF DBC PROGRAMMING MANUAL W/SMART FUNNEL W/SMART FUNNEL

User s Guide and Operator Instructions

hot beverage brewers NOTICE TO INSTALLER: Please leave this book with the machine.

FETCO COFFEE BREWER: CBS-1150 EXTRACTOR V+

CBS-7000 Series Coffee/Tea Brewers and Dispensers. High Volume Brewing

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

E N T E R P R I S E S

FETCO COFFEE BREWER: CBS-1150 EXTRACTOR V+

User s Guide and Operator Instructions

TITAN DUAL TITAN SINGLE PROGRAMMING MANUAL

ITB/ITCB ICB/TWIN Infusion Series

Conv. Pre Heat. Speed. bake. clean. Conv. Bake time. Clean. convert. Maxx clean. Conv. Broil. roast. Oven

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

FETCO COFFEE BREWER: CBS-1130 EXTRACTOR V+

Armonia Smart. Quick Start Guide MACHINE DESCRIPTION STARTING UP

User s Guide and Operator Instructions

Model: NOTICE TO INSTALLER: Please leave this User Guide with the brewer. Table of Contents

DUAL SH DBC WITH SMART FUNNEL Software Version 1.15 and all ending.15

ITB/ITCB/HV ICB/TWIN Infusion Series

Operating the Rancilio Silvia after PID kit modification Version 1.1

hot beverage brewers NOTICE TO INSTALLER: Please leave this book with the machine.

Fetco CBS-2141XTS & CBS-2142XTS Extractor Touch Screen models shown with optional LUXUS L3D dispensers

BUNN TECHNICAL TRAINING ITCB

Oven. Self-Cleaning cycle. Oven. Clock. light. Start time. Bake time

Vision, Mission & Values

20:1 Coffee/Tea Brewer Operation and Service Manual

QWIKBREW 2 TWIN 5.6kW (P/N: )

My Café AP PROGRAMMING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX:

Convection. Clock Used to set the time of day. Even-Cook Convection Ovens P R. Speed clean R B B PM CONV PRE- BAKE

E N T E R P R I S E S

Machine No. 2, SV=104. Figure 1

User s Guide. CBS-62H Coffee Brewer Maritime Version Rated IP44. Table of Contents

Wilbur Curtis Company, Inc. Service Manual GEMSS

ICB Twin SH, ICB SH, ICBA SH Infusion Series

User s Guide. CBS-3000A Series Coffee Brewers. Models: CBS-31A CBS-31Aap CBS-32A CBS-32Aap. Table of Contents

MARCO BEVERAGE SYSTEMS LTD.

SERVICE SUPPLEMENT TO

2016/17 CATALOG EQUIPMENT AND ACCESSORIES ( REVISED MAY 2017*)

TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

BakeiUse to select the normal baking feature. ibp. Cony Bake --Used to select the convection bake feature.

coffee wakes up the world User Manual Coffee machine English V0.16

F R E S H C U P. Single Serve Automatic Eject Pod System by:

Important Safeguards/Symbols. WARNINGS To help avoid personal injury. Important Notes/Cautions from the factory

CMC DUO. Standard version. Table of contens

Operation and Service Manual

Service Manual Iced Tea & Combo Brewer

Wilbur Curtis Company, Inc. Service Manual Iced Tea & Combo Brewer

EXPOBAR OFFICE MACHINES

5 Clear Off / Lockout Key 6 Smart Diagnosis TM (on some models) 7 Cooktop Control

Care & User Manual - TopBrewer Compact

Wilbur Curtis Company, Inc. Service Manual TCT & PTT

Calibrate grill heat zones Monthly GR 1 M1

Nothing less - just the best!

SERVICE MANUAL. Maxibrew 8.6kw 2012 Onwards version

Draught System Troubleshooting & Reference Manual

PROGRAMMING MANUAL. Sure Immersion 220 Bean-To-Cup, Single Serve, Air Infusion Brewer

Hotpoint H/A - Ariston automatic, built-in coffee machine MCX 103 X - MCK 103 X/HA

Medfusion 3500 V6. Syringe Infusion Pump. Quick Reference Card

Installation and User Instructions Flushing System Kit

Shotmeister Owner s Manual. The Sleekest Design, Pouring the Coldest Shots

MTN Products. AquaCafé r (Touch Capsules) Installation & Operations Manual

EP3559, EP3558 EP3551, EP3550

WILBUR CURTIS COMPANY, INC.

Mild or Bold Hot or Cold. Newco s LCD Series offer you coffee or tea on demand just the way you want it.

User s Guide. CBS-5000 Series Coffee Brewers. Models: CBS-51H10 CBS-51H15 CBS-52H15 CBS-52H20. Table of Contents

Wilbur Curtis Company, Inc. Service Manual, Alpha G3 - Decanter Brewer

Operator Manual TB Series Iced Tea Brewers & Dispensers Models TB3, B1/3, B1/3T, SU3P

BREW EXPRESS IMPORTANT NOTE: model no. BE-104 & BE-110. For more information see our instructional video online at

Espresso Machine. Made In Italy By. Owner s Manual

TEA CATER USER MANUAL. UM_EN Part No.:

Espresso Machine. Made In Italy By

ELECTRONIC OVEN CONTROL GUIDE

Wilbur Curtis Co., Inc. Service Manual McDonald s Sweet Tea Brewer

USING THE OVEN BAKE. Displays for the BAKE mode. Changing Bake Temperature while Cooking (example changing from 375 F to 425 F):

Brew Bomb X-45 Getting Started

User s Guide. CBS-5000 Series Coffee Brewers. Models: CBS-51H10 CBS-51H15 CBS-52H15 CBS-52H20. Table of Contents

Wilbur Curtis Company, Inc. Service Manual D500GT Airpot Brewer

Service Manual GEM-12D

RELEASED FOR PRODUCTION PROGRAMMING MANUAL

SINGLE SERVING AUTOMATIC POD MACHINE FKP-4T

Owner s manual Platinum B70 Keurig Brewer


Wilbur Curtis Company, Inc. Service Manual Alpha McDonald s Fresh-Trac

Hot Drink Center. Model 653, 655, Enterprise Way Bridgeton, Missouri (314) Copyright 11-02

G F I M J K L B C D E S O T H Q P U N R D 4

SET UP / OPERATION GUIDE

Crem TechTM e-system Group Keypads + Oled Displays Main Display Hot Water Keypad Connectivity

Infusion Series. Twin Brewer with modern Soft Heat servers. Great Design. Quality in the Cup NEW

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

Transcription:

Programming Guide For EXTRACTOR Coffee Brewers (CBS 2000e Series) Main: (847) 719-3000 email: techsupport@fetco.com Toll Free: (800) 338-2699 2004 Food Equipment Technologies Company www.fetco.com Part # P113 September, 2011

Default Settings Name CBS-2031e/s CBS-2041e CBS-2051e CBS-2061e CBS-2032e/s CBS-2042e CBS-2052e CBS-2062e X.1 Brew Volume 2.5 LTR 1.0 GAL 1.5 GAL 3.0 GAL X.2 Brew Time (Min:Sec) 4:00 4:00 4:00 4:30 X.3 Bypass Percent N/A 0% 0% 0% X.4 Prewet Percent 0% 0% 0% 0% X.5 Prewet Delay (Min:Sec) 1:00 1:00 1:00 1:00 X.6 Drip Delay (Min:Sec) 1:00 1:30 1:30 4:00 7 Water Temp. 200 F 200 F 200 F 200 F 8 Hot Water Faucet A (auto) A (auto) A (auto) A (auto) 9 Brew at Set Temperature 1 1 1 1 58 Temperature Scale F F F F 59 Water Volume Scale Liters Gallons Gallons Gallons Parameter 60 & 61 Brew Valve Flow Rate 1.48 0.39 62 & 63 Bypass Valve Flow Rate N/A 0.40 1.51 0.33 1.24 Use Parameter 57 to reset all settings to factory defaults. 0.92 3.48 0.33 1.24 1.04 (61) /1.10 (62) 3.94 (61) /4.16 (62) 0.37 (61) /0.39 (62) 1.4 (61) /1.48 (62)

To Enter Programming Mode 9 Turn the brewer off by pressing the main power switch, located behind the front leg. 9 Press the switch again to turn it on. Display reads the last 2 digits of the model number briefly, then S t b. 9 Quickly press & hold STOP button for 3 seconds. Display reads P r G briefly. 9 The display will then show the software version. Example: 0.0 40 9 Press STOP again to continue. Important! *If incorrect button is pressed, turn power switch OFF and start again! Batch Settings 9 Batches are numbered as shown, depending on the model. OR

9 Next, the first batch parameter is displayed batch 1, brew volume Use the SCROLL UP and SCROLL DOWN buttons to adjust. Example: 1.1 1.50 Press the STOP button to go to the next parameter brew time. Example: 1.2 4.00 9 Repeat the last step until all parameters are programmed for batch #1. (See the chart below for an explanation of each parameter.) 9 Next, batch #2 programming begins. Display: 2.0 OFF Change to ON to enable. (The top batch on each side cannot be disabled.) 9 After all batches are programmed, next are the temperature settings. Display: 7 200 Important! After programming, you must press the HOT WATER button to save the settings and exit programming mode, or changes will be lost. You may exit programming at any time.

Batch Parameters (X = Batch Number) Parameter Name Range Comment X.0 Batch Enabled or Disabled On/Off X.1 Brew Volume Depends on model. Top batch on each side cannot be disabled. To switch between gallons and liters, see # 59 in Advanced Settings section. X.2 Brew Time (Min: Sec) 2:00 24:00 X.3 Bypass Percent 0.00 40.0% Percentage of total brew volume. (Not available on some models.) X.4 Prewet Percent 0.00 15.0% Percentage of total brew volume. X.5 Prewet Delay (Min:Sec) X.6 Drip Delay (Min:Sec) 0:30 6:00 Minutes 0:10 5:00 The time between end of prewet cycle and start of brew cycle. Brew switch continues to flash. Baskets remain locked, if applicable.

Temperature Settings Parameter Name Range Comment 7 Water Temp. ( F) 180-208 F Temperature inside tank. Will be slightly lower at CSD and faucet. To display in Celsius, see # 58 in 8 Hot Water Faucet A (auto) On Off 9 Brew at Set Temperature Advanced Settings. A= Faucet will dispense only when not brewing. On=Faucet always enabled. Off=Faucet always disabled. 0-1 0=Will brew at any temperature. 1=Will brew only at set temperature. Note: Changes will not take effect until after the next brew cycle is over.

Parameter Name Range Comment 10 Enter Advanced Settings & Diagnostics 0-1 0 = Skip Advanced Settings & Diagnostics. Loop back to start of batch programming. 1 = Enter Advanced Settings & Diagnostics. Jumps to parameter 50. Important! After programming, you must press the HOT WATER button to save the settings and exit programming mode, or changes will be lost. You may exit programming at any time.

Advanced Settings and Diagnostics Address Description Range Comment 50 Water Level in Tank 0-1 Tests if tank is full. 0 = Tank is not full. 52 Brew Basket Sensor State (left / right) 55 Tank Temperature (for most brewers) 56 Brewer Model Number 31 52 -OR- 1 = Tank is full. 0-1 Not available on some models. To test, slide the brew basket in and out. Display should toggle between 0 and 1. 0 = Brew basket out. 1 = Brew Basket in. 180-208 F Displays current tank temperature. Must be set for the correct model number 61 62* of the brewer: *displays only on 31 for CBS-2031e, CBS-2061e or 32 for CBS-2032e, CBS-2062e models 41 for CBS-2041e, etc.

57 Reload Defaults 0-1 Changes all settings to default factory settings. 0 = Do not reload defaults 1 = Reload all default settings If 1 is selected, you must advance to the next address for this change to take effect. 58 Temperature Scale F or C F = Displays temp in degrees Fahrenheit C = Displays temp in degrees Celsius 59 Water Volume Scale GAL or LTR GAL = Displays volume in gallons LTR = Displays volume in liters

60 and 61 62 and 63 Left Brew Valve Flow Rate Right Brew Valve Flow Rate Left Bypass Valve Flow Rate Right Bypass Valve Flow Rate Depends on model. See User s Guide. Depends on model. See User s Guide. Not available on some models. Use this to compensate for minor discrepancies in actual volume versus programmed volume. Set lower to increase volume, higher to decrease volume. The following formula can be used to determine the correct setting: Actual volume divided by programmed volume X current setting = new setting.

64 Keypad Test 0-1 Tests keypad switches. 0 - Skip keypad test 1 - Keypad test active Starting at the top, press each button. Display will read the name of the switch. (S1, S2, etc.) The hot water switch must be pressed last, as this will exit the test. 65 Relay Test 0-1 0 - Skip relay test. Loop back to #50. 1 Relay test active. Go to #90.

Relay Test Tests the individual relays which control various components. Press top batch button = ON. Press bottom batch button=off. To begin, first press the blinking Control Panel Power Switch. Address Description Comment 90 Left or Single Brew Valve 91 Right Brew Valve 92 Left or Single Bypass Valve Not available on some models. 93 Right Bypass Valve Not available on some models. 94 Hot Water Faucet 95 Fill Valve 96 Heater To protect the heaters, this test will work only if the tank is full. 97 Left / Single Brew Basket Lock Not available on some models. 98 Right Brew Basket Lock Not available on some models. Press to exit Relay Test. Press again to exit Diagnostic mode. WARNING! Hot water may be dispensed from the valve being tested. Press again to exit Programming mode and return to Operating mode. NOTICE: Be sure all valves and components are in the OFF position before EXIT is made FETCO, EXTRACTOR and DRIVEN TO INNOVATION are trademarks or trade names of Food Equipment Technologies Company.