Certified Home Brewer Program. Minimum Certification Requirements

Similar documents
Golden Cup Award Application and Evaluation Procedures

COFFEE BASICS SCAA. The Elements of Proper Brewing and Creating an Ideal Coffee Drinking Experience

SCAA Best Practice Guidelines for Using By-Pass in the Drip Coffee Brewing Process

COFFEE BASICS. The Elements of Proper Brewing and Creating an Ideal Coffee Drinking Experience SCAA

SHUTTLE BREWING SYSTEMS

CBS-7000 Series Coffee/Tea Brewers and Dispensers. High Volume Brewing

Brew Bomb X-45 Getting Started

Operating the Rancilio Silvia after PID kit modification Version 1.1

AWRI Refrigeration Demand Calculator

PLEASE READ THIS MANUAL BEFORE USE. SAVE FOR FUTURE REFERENCE.

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

Grooving Tool: used to cut the soil in the liquid limit device cup and conforming to the critical dimensions shown in AASHTO T 89 Figure 1.

P O L I C I E S & P R O C E D U R E S. Single Can Cooler (SCC) Fixture Merchandising

Buying Filberts On a Sample Basis

Nothing less - just the best!

Tomato Product Cutting Tips

KNOWLEDGE/SKILL REQUIRED

Alcohol Meter for Wine. Alcolyzer Wine

Making Hard Cider. A Guide for Small-Scale Producers. Lee Elliot Williams. Bellevue College. Technical Writing Certificate Program

FOOD SERVICE ESTABLISHMENT PLAN SUBMITTAL INSTRUCTIONS

The Separation of a Mixture into Pure Substances

Programming Guide For EXTRACTOR Coffee Brewers (CBS 2000e Series)

Voice Systems Technology, Inc.

Wega Mininova 2003 Installation Instructions

Matic / THa. Operating instructions COFFEE BREWER. Mode d emploi MACHINE À CAFÉ. Gebrauchsanleitung KAFFEEBRÜHMASCHINE

Official Journal of the European Union L 347/809

GRAIN INSPECTION, PACKERS AND STOCKYARDS CHAPTER 3 ADMINISTRATION FEDERAL GRAIN INSPECTION SERVICE STOP 3630 WASHINGTON, D.C.

Alcohol and Tobacco Tax and Trade Bureau, Treasury 30.1

Mastering Measurements

Identifying and Fixing Tortilla Problems. Steve Bright VP R&D, Quality Mesa Foods

Elements Pour-Over Style Coffee Brewer

COLD BREW COFFEE MAKER. Model# GCM-7800 USER MANUAL

FOOD SAFETY & QUALITY DIVISION MINISTRY OF HEALTH MALAYSIA

YEAST STARTERS. Brewers make wort, YEAST MAKE BEER. A few keys to turning GOOD homebrew into GREAT homebrew

SCA Premier Training Campus

The Scoop 2-Way Brewer

Unit of competency Content Activity. Element 1: Organise coffee workstation n/a n/a. Element 2: Select and grind coffee beans n/a n/a

Recommended Reading: The Basics of Brewing Coffee, Ted Lingle. BLOOMS TAXONOMY: Remembering / Understanding. The Basics of Brewing Coffee, Ted Lingle

INSTALLATION QUICK START GUIDE AND CHECKLIST ATTENTION!! DO NOT ATTEMPT A PARTIAL INSTALL.

DRAFT EAST AFRICAN STANDARD

#611 ON-SITE TESTING AND EVALUATION

Test sheet preparation of pulps and filtrates from deinking processes

Distillation Note Books

Official Journal of the European Union L 154/39

Size Matters: Smaller Batches Yield More Efficient Risk-Limiting Audits

TROUBLESHOOTING GUIDE FLOUR TORTILLAS

Perfectly you rs. Dinamica is a new range of De Longhi bean to cup coffee makers designed to satisfy every coffee desire.

A-A September 1990 COMMERCIAL ITEM DESCRIPTION COFFEE MAKER, ELECTRIC, AUTOMATIC

Artisan-made ice cream, just as you like it. And much, much more...

DRAFT EAST AFRICAN STANDARD

Determination of Alcohol Content of Wine by Distillation followed by Density Determination by Hydrometry

TRUSTED RELIABLE QUALITY

#611-7 Workbook REVIEW OF PERCOLATION TESTING PROCEDURES. After completing this chapter, you will be able to...

Recipe Adjustment Factor Method

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

MTN Products. AquaCafé r (Touch Capsules) Installation & Operations Manual

#COFFEEXPERIENCES COFFEE PERFECTION

Prac;cal Sessions: A step by step guide to brew recipes Milk for baristas

MANUAL BREWING AEROPRESS CHEMEX HARIO V60 CLEVER FRENCH PRESS

#COFFEEXPERIENCES COFFEE PERFECTION

NEW! SMART SNACK COMPLIANT SFC # Whole Grain Chicken Egg Roll (2.5oz) Chef s Corner 1787 Sabre Street Hayward, CA CHEF

Glutomatic System. Measure Gluten Quantity and Quality. Gluten Index: AACC/No ICC/No. 155&158 Wet Gluten Content: ICC/No.

DRAFT TANZANIA STANDARD

P O L I C I E S & P R O C E D U R E S. I.C.E. In-store Merchandising

DRAFT EAST AFRICAN STANDARD

NU 620 Performance Evaluation

Getting the Most from Beer Brewing Software. Brad Smith, PhD

CMBTC 2017 Crop MALTING BARLEY QUALITY ASSESSMENT Preliminary Report

Setting up your fermentation

ISO 712 INTERNATIONAL STANDARD. Cereals and cereal products Determination of moisture content Reference method

cocoa mass, cocoa butter and cocoa powder

AS450, AS600, G1, SG630

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2293

Republika e Kosovës Republika Kosovo - Republic of Kosovo Kuvendi - Skupština - Assembly

TEA CATER USER MANUAL. UM_EN Part No.:

LAW No. 04/L-019 ON AMENDING AND SUPPLEMENTING THE LAW NO. 02/L-8 ON WINES LAW ON AMENDING AND SUPPLEMENTING THE LAW NO. 02/L-8 ON WINES.

User Guide TEA CATER. Your Dealer. U / EN Rev

SUCCESSFUL BOTTLING by Lum Eisenman

Winemaking and Sulfur Dioxide

2018 Special Foods Contestant Packet AUGUST 30 & 31, SEPTEMBER 1, 2018

Buona Fortuna Training Manual Technical Instructions

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

Application & Method. doughlab. Torque. 10 min. Time. Dough Rheometer with Variable Temperature & Mixing Energy. Standard Method: AACCI

CODEX STANDARD FOR QUICK FROZEN WHOLE KERNEL CORN CODEX STAN

Directions for Menu Worksheet ***Updated 9/2/2014 for SY *** General Information:

TRUSTED RELIABLE QUALITY

ESPRESSO. Esprecious FreshMilk. The taste of quality worldwide

Brewculator Final Report

Separating the Components of a Mixture

SIMPLEX STRAINER MODEL 90

INTRODUCTION TO CUSTOM FABRICATED STRAINERS

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

左边 :SAFTY NOTES 右边 : Please follow the safety precautions to avoid any harm to yourself and cause any damages Never Always Warning Attention

Aroma Fresh. Instructions for use Includes recipes. Model BCM120

PASSION FOR TECHNOLOGY LEGACY OF

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft COMMISSION DIRECTIVE../ /EC

EAST AFRICAN STANDARD

Frequently Asked Questions

Big Data and the Productivity Challenge for Wine Grapes. Nick Dokoozlian Agricultural Outlook Forum February

Evaluation of the Malting and Brewing Performance of the New Canadian Malting Barley Variety Norman

Transcription:

Certified Home Brewer Program Minimum Certification Requirements

SCA's Minimum Certification Requirements for Coffee Brewers 1. Coffee Volume: The volume of the brew basket must be sized in proportion to the beverage receiver's maximum capacity as stipulated by the manufacturer. Minimum technical requirement is for brew basket capacity to accommodate the Gold Cup Ratio weight of coffee per maximum capacity (~55 grams per liter) without overflowing from the basket due to the swelling of the coffee grounds during the brew cycle. This allowance is recommended to be about 50% of the bed depth of the coffee. Best results in uniformity of extraction are obtained with coffee bed depths between 2.5 and 5.0 cm, but these dimensions are not a requirement for the certification. 2. Brewing Time: The coffee brewer must be able to cycle its full-capacity water volume through the coffee grounds within the prescribed amount of time. For a brewer at maximum coffee and water capacity, the minimum technical requirement is for the water contact time with the coffee grounds shall be more than 4 minutes but less than 8 minutes for all brewers operating under standard temperature and pressure, depending on grind. The start of the brew time will be judged as the moment when the first drops of coffee fall from the basket to the bottom of the carafe and the end of the brew time will be when the steam of brewed coffee changes from a to a drip from the brew basket. Under no circumstances will water contact times in excess of 8 minutes be acceptable in meeting the certification requirements. 3. Brewing Temperature: The coffee brewer must be able to cycle the gross water volume through the coffee grounds within the prescribed temperature range. Minimum technical requirement is for the water temperature at the point the water contacts the coffee grounds to reach 92 C within the first minute, maintain at least that temperature (92 C) for the remainder of the brew cycle, and never exceed 96 C. Measurement of brewing temperatures will be made by using an RTD (Resistive Temperature Device) placed at the top and in the center of the bed of coffee in the brew basket. During the brew, due to the activity in the basket, the temperature sensor is allowed to float in the top section of the brew slurry. Additionally, a variety of other sensor configurations may be performed as necessary to troubleshoot brewer-specific issues. It is our goal to document the most accurate temperature of the point of contact between the coffee and water. 4. Beverage Preparation: The coffee brewer must be able to produce a beverage with the prescribed range of solubles concentration and solubles yield. The brewer will be evaluated at stated full

capacity as well as at the 1 liter brew water volume. In situations where 1 liter is the maximum capacity of the brewer, the 0.5 liter brew will also be tested. Testing will begin with a coffee/water ratio of 55g/1L, but will be adjusted depending on the grind and contact time to produce a brew within the Gold Cup zone of the brewing control chart. Minimum technical requirement is for a beverage strength (solubles concentration) of between 1.15% and 1.45% resulting from an extraction (solubles yield) of between 18.0% and 22.0% from the weight of coffee in the brew basket, as determined by a coffee refractometer and brewing control chart. All samples measured on the coffee refractometer are filtered prior to measurement. The grind of the coffee will be adjusted for the water contact time of the brewer in order to achieve these results whenever possible, within the specified grind parameters (see below testing procedures). Brewers must be able to meet these requirements at both full capacity and a 1 liter capacity in order to be certified by the SCA. Brewers with the full capacity of 1 L will also be tested at 0.5 L. 5. Uniformity of Performance: To assure the brewer model is both consistent and reliable, it will be tested for uniformity of performance. For this test, a minimum of 5 coffee brewers will be evaluated. If a brewer manufacturer has never submitted a model to the SCA before, up to 10 individual brewers may be requested for additional testing. During testing, at least 10 separate brew cycles will be run on each brewer to evaluate solubles concentration using the coffee refractometer method and extraction calculated using the Coffee Brewing Control Chart. All samples will be filtered prior to measurement on the coffee refractometer. The coffee brew resulting from these 10 tests must range between 1.15% to 1.45% solubles concentration for all individual brewers tested. The corresponding range for solubles yield must fall between 18.0% and 22.0%. 6. Uniformity of Extraction: At a minimum, all of the coffee in the brew basket must be wetted during the first minute of brewing to give opportunity for proper extraction. Brewers will receive a numerical rating based on the average uniformity of extraction factor as determined by the SCA Uniformity of Extraction Procedures (Click here for a downloadable copy) for the weight of coffee at a used for the maximum water volume capacity of the brewer as stated by the manufacturer or to the SCA Gold Cup Ratio of 55 g/l. The rating number is calculated by comparing residual soluble solids in the outside, middle, and inside areas of the wet coffee grounds in the brew basket. The result is multiplied by 100 to convert the percentage to a whole number. The Index Rating is 0-100, with 100 indicating perfect uniformity of extraction. An average uniformity rating number of 60 would be considered "good," a rating number above 75 would be considered "excellent," and a rating number above 90 would be "outstanding." All ratings below 60 would be listed as "needs improvement and would

result in the brewer not passing SCA testing and therefore needing improvement for future brewer certification by the SCA. 7. Beverage Clarity: Excessive sediment in the brewed coffee should be avoided. If sediment is present, the amount of will be measured in the following method: 100 grams of brewed coffee is poured through a filter paper of known weight, which is dried and weighed again. The increase in the weight of the paper is the weight of the sediment. No equipment that produces sediment of more than 75 milligrams per 100 milliliters of brewed coffee will be accepted. The brewer must produce less than 75 milligrams of sediment per 100 milliliters of brewed coffee to be certified by the SCA. 8. Holding Receptacle & Temperature: The container that receives the coffee after brewing must accommodate the quantity of coffee for which the brewing equipment is designed at the maximum water volume capacity designated by the manufacture and maintain the temperature of the brewed coffee at the correct holding temperature. Minimum technical requirement is for the beverage receiver to maintain the temperature of the coffee no lower than 80 degrees C and no higher than 85 degrees C during the first thirty (30) minutes of the holding time. During this time, at no point should the temperature of the coffee increase due to a heating element. 9. Operating Manuals and other Instructional Materials: The minimum requirement for certification is that all instructional materials including operating manuals, pamphlets, and promotional items supplied with the brewer. Proper brewing instructions must be included, specifically some suggestion of a coffee/water ratio that results in a Gold Cup brew and cleaning instructions. The SCA will note errors and propose necessary changes to the brewer manufacturer. A brewer submitted for testing will not be considered ready for SCA certification before these matters are resolved. Testing Procedures: a. Batch Size: All brewers are tested at full capacity and 1 L water volume (with 15±5 C water). If the brewer s maximum capacity is 1 L, 0.5 L will also be tested. b. Coffee: Evaluations of minimum technical requirements in beverage preparation will be made using coffees in the medium roast color range (SCA #55 roast color tile). In addition beverage evaluations will also be made using coffees in the dark roast color range (SCA #35 roast color tile). Coffees at least of 1-1.5 weeks off-roast will be utilized to assure consistent brewing.

ECBC Grind for Brewer Testing SCA Grind for Brewer Testing Size Range (µm) Percent (%) by weight Size Range (µm) Percent (%) by weight >850 12 >1168 17 425-850 68 589-1168 65 <415 20 <589 18 c. Grind: All testing will commence with the above coffees ground to a common particulate distribution chosen to systematize the testing process. This grind distribution will have less than 17% (by weight) of the grinds above 1168 µm in size, at least 65% of grinds falling between 589-1198µm, and 18% or less being smaller than 589 µm. This is close to but not replicating the ECBC grind distribution for testing, due to regional differences in market norms. See the table below for further specification. d. Water: Fresh, cold water 15±5 degrees Celsius ( C), containing a baseline dissolved mineral content of 150 ppm (0.150%) with a tolerance of 20 ppm (+/- 0.20%), of which a sub-set of hard minerals is 17 mg/l - 85 mg/l calcium hardness, and a ph of 7.0 (+/- 0.5) will be used in all of the brew testing. e. Coffee to Water Ratios: Evaluations of minimum technical requirements in beverage preparation will be made using the nominal weight of coffee specified by the SCA Coffee Brewing Control Chart (55 grams of coffee per liter of 15±5 C water) for the actual maximum water volume rating of the brewer, as specified by the manufacturer. In addition beverage evaluations will be made using 1 liter of water, with the same coffee/water ratio. f. Water Supply: For plumbed-in units, the water pressure will be controlled by a pressure regulator to maintain the minimum pressure designated by the manufacturer.