Application Note CL0311. Introduction

Similar documents
Automation of AOAC for the Identification of FD&C Color Additives in Foods using Solid Phase Extraction

Assessment of the CDR BeerLab Touch Analyser. March Report for: QuadraChem Laboratories Ltd. Campden BRI Group contracting company:

Determination of Caffeine in Coffee Products According to DIN 20481

Correlation of the free amino nitrogen and nitrogen by O-phthaldialdehyde methods in the assay of beer

! " # # $% 004/2009. SpeedExtractor E-916

Alcohol Meter for Wine. Alcolyzer Wine

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

Beer bitterness and testing

PECTINASE Product Code: P129

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

The Determination of Pesticides in Wine

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Tyler Trent, SVOC Application Specialist; Teledyne Tekmar P a g e 1

TSKgel TECHNICAL INFORMATION SHEET No. 131

EXTRACTION PROCEDURE

General overview of the two stages of the QuEChERS technique. Stage 1: Sample extraction. Stage 2: Sample cleanup

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

Separating Mechanical Mixtures

Yeast nuclei isolation kit. For fast and easy purification of nuclei from yeast cells.

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

Extraction of Phenolic Acids from Plant Tissue Using Accelerated Solvent Extraction (ASE )

Zoe Grosser, Vinson Leung, Jim Fenster, Brian LaBrecque Horizon Technology, Inc., Salem, NH USA

Separation of a Mixture

Analysis of Resveratrol in Wine by HPLC

ASSET EZ4-NCO Dry Sampler Extraction Procedure.

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

Measuring tannins in grapes and red wine using the MCP (methyl cellulose precipitable tannin assay

Recent Developments in Rheological Instruments

Solid Phase Micro Extraction of Flavor Compounds in Beer

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

What s New? AlveoLab, SRC-CHOPIN, Mixolab 2. CHOPIN Technologies Geoffroy d Humières

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

Determination of Metals in Wort and Beer Samples using the Agilent 5110 ICP-OES

ION FORCE DNA EXTRACTOR FAST Cat. N. EXD001

Application Note No. 184/2015

RULE BAKERY OVENS (Adopted & Effective: 6/7/94: Rev. Adopted & Effective 5/15/96)

Determination Of Saponin And Various Chemical Compounds In Camellia Sinensis And Genus Ilex.

Introduction. Experimental. : : APPLICATION NOTE SP024: Pesticide Anaylsis: Standard QuEChERS vs Modified Method. : : APPARATUS: Geno/Grinder

RISK MANAGEMENT OF BEER FERMENTATION DIACETYL CONTROL

Michigan Grape & Wine Industry Council Annual Report 2012

DR6000 in the Brewing Industry: Important Methods in Accordance with MEBAK and ASBC

Alcohol and Extract Meter for Beer, Wine, Cider, Spirits, Liqueurs, and Sake

CHEM Experiment 4 Introduction to Separation Techniques I. Objectives

For Beer with Character

LEHUI MICRO BREWERY EQUIPMENT 2009/ 8

Glutomatic System. Measure Gluten Quantity and Quality. Gluten Index: AACC/No ICC/No. 155&158 Wet Gluten Content: ICC/No.

Pankaj Jain Proprietor & Founder of Relitek Services is a Highly Technical & Qualified Engineer from the field of industrial electronics.

Innovations for a better world. Ingredient Handling For bakeries and other food processing facilities

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

Use of Accelerated Solvent Extraction (ASE) with Centrifugal Evaporation to Automate Fat Determination in Chocolate

Separating the Components of a Mixture

Alcolyzer Plus Spirits

Sequential Separation of Lysozyme, Ovomucin, Ovotransferrin and Ovalbumin from Egg White

Environmental Monitoring for Optimized Production in Wineries

Determination of wine colour by UV-VIS Spectroscopy following Sudraud method. Johan Leinders, Product Manager Spectroscopy

CMC DUO. Standard version. Table of contens

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

Wine Preparation. Nate Starbard Gusmer Enterprises Davison Winery Supplies August, 2017

A Fast Method for Sugar Analysis of Instant Coffee Samples

Identification of reconstituted milk in pasteurized and UHT milk

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

Validation Report: Total Sulfite Assay Kit (cat. no. K-TSULPH)

Setting up your fermentation

Unique Carbohydrate Profiles In Different Brands of Tequila

JUICE EXTRACTION AND FILTRATION JUICE EXTRACTION METHOD AND EQUIPMENT

Application Note. Hydrolysis Unit E-416, Extraction Unit E-816 Soxhlet. Fat determination according to Weibull-Stoldt - Standard application

APPLIED. Measuring Caffeine Concentration. Application Summary. Analytes: caffeine (C 8 H 10 N 4 O 2

Protect Your Mass Spec

Response of Camelina Varieties to NaCl Salinity

Analysis of Beta-Carotene and Total Carotenoids from Pacific Sea Plasma (Spectrophotometric Method)

CHAPTER 8. Sample Laboratory Experiments

3. Aspirin Analysis. Prelaboratory Assignment. 3.1 Introduction

White Paper. Dry Ingredient Chilling for Bakery Manufacturers.

Certified Home Brewer Program. Minimum Certification Requirements

FTIR Analyzer. Lyza 5000 Wine

Islamic Kasim Tuet Memorial Secondary School. Chun Suk Kwan 6S (6)

Novozymes & Gusmer Enterprises WINE ENZYMES SOLUTIONS

Water Technologies & Solutions. wine processing. 21 st century membrane technology

Validation Report: Free Sulfite Assay Kit (cat. no. K-FSULPH)

Test sheet preparation of pulps and filtrates from deinking processes

End to End Chilled Water Optimization Merck West Point, PA Site

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Data Pack. Ultra Low Flow Methods. September 2009

Solid Phase Micro Extraction of Flavor Compounds in Beer

Experiment 6 Thin-Layer Chromatography (TLC)

TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

Magnetic Luminex Assay

An Investigation of Methylsufonylmethane as a Fermentation Aid. Eryn Bottens, Jeb Z Hollabaugh, and Thomas H. Shellhammer.

Bromine Containing Fumigants Determined as Total Inorganic Bromide

EXTRACTION OF SEDIMENTS FOR AROMATIC AND CHLORINATED HYDROCARBONS

Milk and By-products. Milk and by-products. Dairy products are fundamental to maintain a complete nutritional balance.

RAPID, SPECIFIC ANALYSIS OF MELAMINE CONTAMINATION IN INFANT FORMULA AND LIQUID MILK BY UPLC/MS/MS

Transcription:

Automation of AOAC 970.16 Bitterness of Malt Beverages and AOAC 976.08 Color of Beer through Unique Software Control of Common Laboratory Instruments with Real-Time Decision Making and Analysis Application Note CL0311 Automation of AOAC methods 970.16 and 976.08 using conditional logic to modify experimental protocols in real time was successful. Further method and procedural optimization can be done to improve result correspondence. Introduction A typical laboratory is frequently looking for ways to increase consistency and throughput. A common way to achieve this is through finding an automated solution for manual techniques. One of the largest hurdles for automation of manual methodology, no matter how simple, is the necessity of decision making based on realtime sample analysis, which typically requires the coordination of input from multiple components with varying manufacturers. In this study, a unique, single software control of a liquid handler, spectrophotometer equipped with multiple flow cells and shaker block with temperature control capabilities brings each component together into a single automated solution from multiple manual AOAC methods. Figure 1. A) Agilent 8453 UV-Visible Spectrophotometer with Multicell Transport, B) Gilson GX-271 ASPEC System, C) Torrey Pines Scientific EchoTherm SC20XT. P a g e 1

Materials & Methods The focus of this experiment was to utilize unique software control of common laboratory equipment to allow for real-time protocol alteration by automated equipment. Through the use of conditional logic based upon inputs from a spectrophotometer and shaker block, TRILUTION LH v3.0 Software was able to alter the course of the protocol to accommodate necessary changes. An example of the conditional logic used to determine if filtering of the beer sample was necessary during AOAC method 976.08 is displayed below in Figure 2. Figure 3 demonstrates the software protocol used to ensure proper sample temperature for AOAC method 970.16. In each of the protocols, the IF steps (orange tasks) are used to direct future operation. Figure 2. TRILUTION LH v3.0 Protocol for Conditional Logic in Beer Filtration. P a g e 2

Figure 3. TRILUTION LH v3.0 Protocol for Conditional Logic in Temperature Equilibration AOAC method 976.08 for Color of Beer results are derived from a simple spectrophotometer reading at two wavelengths after degassing. Based on the absorbance readings, the sample may require filtration and the readings repeated. The study showcases online absorbance readings for the software to react in real-time and use conditional logic to perform the automated rework of the sample when necessary. AOAC method 970.16 for Bitterness of Malt Beverages requires temperature controlled samples to undergo liquid-liquid extraction (LLE) prior to absorbance readings. Control of the chilled shaker block allows for a record of sample temperature at run time and shaking of the sample when required. Online transfer to the spectrophotometer records absorbance values, taking sample readings immediately and without the need for physical intervention. Samples and Solvents Beers supplied by microbrewery (Figure 4) Isopropanol (B&J, P/N 10071758) Hydrochloric Acid (Sigma, P/N 258148) 2,2,4-Trimethylpentane (isooctane)(sigma, P/N 155012) 1-Octanol (Sigma, P/N 293245) NanoPure Water Figure 4. Beer Samples Used for the Study. From left to right: American Pale Lager, Cream Ale, American Pale Ale, German Pilsner, English Brown Ale, Bock. Apparatus Gilson GX-271 ASPEC System 10 ml syringe GX Transfer Port Assembly (Special 1785) Special 1891 for on bed placement of SC20XT Agilent 8453 UV-visible Spectrophotometer Multicell Transport (8-cell) (8) Flow Cell (10 mm, 430 μl) Torrey Pines Scientific EchoTherm SC20XT Heater, Chiller, and Orbital Shaker with Aluminum block for (6) 50 ml centrifuge tubes Phenomenex Single-fritted Empty 6 cc SPE Cartridge (P/N AH0-8942) Phenomenex 0.45 μm 13 mm Nylon Filter (P/N AF0-0500) P a g e 3

Protocols 1. AOAC Method 976.08 Color of Beer: a. Room temperature beer was opened and transferred to a 50 ml centrifuge tube b. The beer was shaken on the SC20XT shaker unit for 90 minutes to degas c. 3 aliquots of beer were transferred via the GX-271 ASPEC and transfer ports to flow cells on the 8453 UV-Visible spectrophotometer Data was collected from detectors in real time and applied to automatically adjust the experimental parameters without user intervention, providing walk-away operation. d. Readings were taken at 430 nm and 700 nm e. If A700 nm A430 nm * 0.039, the sample was deemed turbid and the GX-271 ASPEC transferred the beer sample to the filter cartridges f. If A700 nm < A430 nm * 0.039, the sample was deemed free of turbidity and the SRM was calculated 2. AOAC Method 970.16 Bitterness of Beer: a. 10 ml of beer was manually transferred to a 50 ml centrifuge tube and placed on the SC20XT shaker unit b. The SC20XT was set to 10 C and checked every 30 seconds until the temperature was met; sample equilibrated 5 minutes c. 25 µl 1-octanol was transferred via the GX-271 ASPEC to the beer sample, and the sample was shaken slightly to combine d. 1 ml of 3 M hydrochloric acid and 20 ml of isooctane were transferred via the GX-271 ASPEC to the beer sample. e. N 2 gas was bubbled through the beer: isooctane mixture via the syringe pump to perform the liquid-liquid extraction. f. The isooctane layer was manually transferred to small vials g. The isooctane was transferred via the GX-271 ASPEC and transfer ports to flow cells on the 8453 UV-Visible spectrophotometer h. A reading was taken at 275 nm and the BU value was calculated P a g e 4

Results and Discussion TRILUTION LH v3.0 Software was successfully applied to control multiple laboratory devices. The method responded in real-time to inputs from the devices and made corresponding adjustments to experimental protocols. Detailed explanation of the protocols and logic can be found in Figures 5 and 6. Microbrewery beer sample test results are shown in Table 1. Although there are some inconsistencies with the values provided by the brewery, the data show the same trends that were anticipated. Figure 5.. TRILUTION LH v3.0 Protocol Detail for Conditional Logic in Beer Filtration. P a g e 5

Figure 6. TRILUTION LH v3.0 Protocol Detail for Conditional Logic in Temperature Equilibration. Beer Style Provided Color (converted from EBC to SRM) Tested Color (SRM)* Provided BU** Tested BU A American Pale Lager 2.4 3.8 7 12.5 B Cream Ale 4.7 5.6 11 14 C American Pale Ale 5.8 8.1 35.5 23.5 D German Pilsner 12.1 10.4 20 18 E English Brown Ale 24.5 21.6 20 18.5 F Bock 59.6 48.9 19.5 13 Table 1. Beer Characteristics Provided and Testing Results * Note: None of the microbrew beers passed the turbidity requirement, even after filtration. A macrobrew beer was also tested for method verification and did pass the turbidity requirement. ** Note: Beer was tested 6 months after provided numbers were given, and potential degradation of bitterness compounds is a possible explanation for the result inconsistency. Acknowledgments ASPEC is a trademark of EchoTherm is a trademark of Torrey Pines Scientific. TRILUTION is a registered trademark of Summary and Conclusions TRILUTION LH v3.0 is a flexible and powerful software package than controls Gilson automated liquid handlers and can be programmed to control equipment from other manufacturers. Data was collected from detectors in real time and applied to automatically adjust the experimental parameters without user intervention, providing walk-away operation. Automation of AOAC methods 970.16 and 976.08 using conditional logic was successful. Further method and procedural optimization can be performed to improve result correspondence. rev 05/15 P a g e 6