AppNote 4/2003. Fast Analysis of Beverages using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Similar documents
AppNote 2/2003. Wine Discrimination using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

AppNote 1/2003. Fast Analysis of Food and Beverage Products using a Mass Spectrometry Based Chemical Sensor KEYWORDS ABSTRACT

AppNote 13/2002. Classifi cation of Coffees from Different Origins by Chemical Sensor Technology INTRODUCTION

AppNote 13/2012. Automated Solid Phase Extraction (SPE)-LC-MS/MS Method for the Determination of Acrylamide in Brewed Coffee Samples KEYWORDS ABSTRACT

AppNote 6/2013. Using TDU-Pyrolysis-GC-MS to Investigate Aged Whiskey Samples and Their Oak Barrels ABSTRACT INTRODUCTION

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

Identification of Adulteration or origins of whisky and alcohol with the Electronic Nose

Profiling of Aroma Components in Wine Using a Novel Hybrid GC/MS/MS System

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Somchai Rice 1, Jacek A. Koziel 1, Jennie Savits 2,3, Murlidhar Dharmadhikari 2,3 1 Agricultural and Biosystems Engineering, Iowa State University

Comprehensive analysis of coffee bean extracts by GC GC TOF MS

Solid Phase Micro Extraction of Flavor Compounds in Beer

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Cupcake Batter Flavor Concentrate

Fast Analysis of Smoke Taint Compounds in Wine with an Agilent J&W DB-HeavyWax GC Column

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Clove E-liquid Flavor Concentrate. PO Box 2624 Woodinville, WA 98072

Detecting Melamine Adulteration in Milk Powder

Tyler Trent, SVOC Application Specialist; Teledyne Tekmar P a g e 1

Table 1: Experimental conditions for the instrument acquisition method

A novel approach to assess the quality and authenticity of Scotch Whisky based on gas chromatography coupled to high resolution mass spectrometry

CHAPTER 8. Sample Laboratory Experiments

Analytical Report. Table 1: Target compound levels. Concentration units are ppm or N/D, not detected.

AppNote 4/2000. Flavor Profi ling of Beverages by Stir Bar Sorptive Extraction (SBSE) and Thermal Desorption GC/MS/PFPD KEYWORDS ABSTRACT

Emerging Applications

Solid Phase Micro Extraction of Flavor Compounds in Beer

Elemental Analysis of Yixing Tea Pots by Laser Excited Atomic. Fluorescence of Desorbed Plumes (PLEAF) Bruno Y. Cai * and N.H. Cheung Dec.

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

One class classification based authentication of peanut oils by fatty

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

Agilent J&W DB-624 Ultra Inert Capillary Column Screens Distilled Spirits by GC/MS Static Headspace

CHAPTER 8. Sample Laboratory Experiments

Wine-Tasting by Numbers: Using Binary Logistic Regression to Reveal the Preferences of Experts

, FAX

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Varietal Specific Barrel Profiles

Investigating the factors influencing hop aroma in beer

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

ALESSIO TUGNOLO, COMPARISON OF SPECTROSCOPIC METHODS FOR EVALUATING THE PHYTOSANITARY STATUS OF WINE GRAPE, PAGE 6

GC/MS BATCH NUMBER: W10104

The Benefits of GC/MS Coupled with a Headspace Trap to Monitor Volatile Organic Compounds in the Production of Beer

Profiling and Identification of Hop-Derived Bitter Compounds in Beer Using LC-MS/MS

Metabolomic Profiling of Wines using LC/QTOF MS and MassHunter Data Mining and Statistical Tools

The Importance of Dose Rate and Contact Time in the Use of Oak Alternatives

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

Increasing Toast Character in French Oak Profiles

WineScan All-in-one wine analysis including free and total SO2. Dedicated Analytical Solutions

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

Alcolyzer Plus Spirits

ADVANCED BEER AROMA ANALYSIS. Erich Leitner TU Graz, Institute of Analytical Chemistry and Food Chemistry, Graz, Austria

Analytical Traceability of Food and Feed

Wine analysis to check quality and authenticity by fully-automated 1

Analysis of Volatile Compounds of Jasminum nitidum [Acc.JN.1] Flowers

ALPHA. Innovation with Integrity. FT-IR Wine & Must Analyzer FT-IR

Uses of profiling trace metals in wine with ICP- MS and Mass Profiler Professional (MPP) for the wine industry

RECENT DEVELOPMENTS IN FOOD SCREENING BY NMR. Claudia Napoli Bruker Italia

VQA Ontario. Quality Assurance Processes - Tasting

Almond ß-Lactoglobulin (BLG) Casein Egg Gliadin (Gluten) Hazelnut Lupine Mustard Peanut Sesame Crustacea Soy Total Milk (Casein & Whey) Walnut

Analysis of Pesticides in Wine by LCMS

OenoFoss Instant Quality Control made easy

Determination of Caffeine in Coffee Products According to DIN 20481

HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

Determination of Metals in Wort and Beer Samples using the Agilent 5110 ICP-OES

The Good and the Bad Influence of. Polyfunctional Thiols in Beer Hops. Grapefruit or a Cat Box? Application Scientist: Matthew Curtis

Analysis of Volatile Compounds from the Concrete of Jasminum multiflorum Flowers

Predicting Wine Quality

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

The Determination of Pesticides in Wine

Experiment 6 Thin-Layer Chromatography (TLC)

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

What Makes a Cuisine Unique?

Figure 1 Fluorescence Fingerprint of Pineapple Juice and Prediction of Autofluorescence Substances

Modeling Wine Quality Using Classification and Regression. Mario Wijaya MGT 8803 November 28, 2017

Comparison of Supercritical Fluid Extraction with Steam Distillation for the Extraction of Bay Oil from Bay (Pimenta Racemosa) Leaves

Qualitative Analysis of Age and Brand of Unblended Brandy by Electronic Nose

THE BREWING VALUE OF HOPS HOP & BREW SCHOOL A UG 29 S EPT 1, 2017, Y AKIMA

NEAR INFRARED SPECTROSCOPY (NIR) -SPECTROSCOPY, COLOUR MEASUREMENT AND SINGLE KERNEL CHARACTERIZATION IN RYE BREEDING

GAS-CHROMATOGRAPHIC ANALYSIS OF SOME VOLATILE CONGENERS IN DIFFERENT TYPES OF STRONG ALCOHOLIC FRUIT SPIRITS

APPLIED. Measuring Caffeine Concentration. Application Summary. Analytes: caffeine (C 8 H 10 N 4 O 2

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

EFFECT OF TOMATO GENETIC VARIATION ON LYE PEELING EFFICACY TOMATO SOLUTIONS JIM AND ADAM DICK SUMMARY

The Impact of Vineyard Origin and Winery on the Elemental Profile of Red Wines

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

VINOLOK (VINOSEAL) closure evaluation Stage 1: Fundamental performance assessment

AgraStrip Allergens - Lateral Flow Devices

Determination of Volatile Compounds in Romanian White Wines by Headspace Solid-phase Micro-extraction and Gas Chromatography Mass Spectrometry

Michigan Grape & Wine Industry Council Annual Report 2012

The aim of the thesis is to determine the economic efficiency of production factors utilization in S.C. AGROINDUSTRIALA BUCIUM S.A.

Institute of Food Research. Ian Colquhoun

Effects of Adulteration Technique on the NIR Detection of Melamine in Milk Powder

From VOC to IPA: This Beer s For You!

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

TERROIR EFFECTS FROM THE REFLECTANCE SPECTRA OF THE CANOPY OF VINEYARDS IN FOUR VITICULTURAL REGIONS

Rapid Tea Analysis on Poroshell 120 SB-C18 with LC/MS

16th International CEEPUS Symposium and Summer School on Bioanalysis, Warsaw, Poland, July 06-12, 2016

High resolution mass approaches for wine and oenological products analysis

GC/MS BATCH NUMBER: EG0101

[ application note note ] ]

Transcription:

AppNote 4/2003 Fast Analysis of Beverages using a Mass Spectral Based Chemical Sensor Vanessa R. Kinton, Robert J. Collins Gerstel, Inc., Caton Research Center, 1510 Caton Center Drive, Suite H, Baltimore, MD 21227, USA Bita Kolahgar Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1, D-45473 Mülheim an der Ruhr, Germany Kevin L. Goodner USDA, Citrus & Subtropical Products Lab 600 Ave S, NW Winter Haven, FL 33881, USA KEYWORDS ChemSensor, chemometrics, mass spectral, wine, beer, orange juice ABSTRACT Detection of adulteration, contamination or inconsistencies in food and flavor samples should be accurate and fast. Chemical sensors are ideal for these types of applications because they provide fast measurements. While analysis times are crucial, accuracy and precision of the analysis should never be compromised. It is therefore desirable to use a reliable and stable technology that is robust to environmental changes such as humidity or temperature. Quadrupole mass spectrometry is a robust technique that has been widely used in food and flavor applications. In this study, mass spectral fingerprints of orange juice and wine samples were obtained by direct transfer of their headspace into a mass spectrometer without chromatographic separation. For the beer samples a GERSTEL ChemSensor System that includes a GC was used. Stan-

dard samples were used to train the chemical sensor with acceptable mass spectral profiles. Adulteration of wine samples was modeled with two different types of wines; contamination was detected by spiking orange juice with diacetyl and inconsistencies in products was modeled by analyzing beer samples freshly opened and aged 3 and 6 days. Detection of contamination, adulteration and product inconsistencies was easily determined using chemometric models. In particular, principal component analysis (PCA) easily detected anomalies by projection of the mass spectral fingerprints into the space of the first three or two principal components. Adulteration of the wine standards was detected in the percentage range while diacetyl concentrations in orange juice were detected at the low ppm range. Slight differences between beer samples freshly opened and aged 3 and 6 days were also detected and identified. In this study, headspace (HS) volatiles from wine and orange juice are introduced without chromatographic separation to a quadrupole mass selective detector (MSD) using a GERSTEL Headspace ChemSensor (Figure 1A). Also, volatiles from beer samples concentrated in a SPME fiber are introduced to a GERS- TEL ChemSensor System (Figure 1B). The resulting composite mass spectrum of each sample is used to train the chemical sensor using multivariate pattern recognition techniques. Unknown samples are easily compared to standards using integrated multivariate analysis software that can be easily customized to reflect pass or fail decisions. INTRODUCTION Identification of product adulteration, contamination or inconsistency in food samples greatly benefits when the total analysis times are short. This includes sample preparation and instrument time. Chemical sensors are ideal for these types of applications because they provide fast results with minimal sample preparation. For example, a robust chemical sensor is obtained when well-known mass spectrometry technology is coupled with multivariate data analysis. Mass spectrometry is a robust technology that is unaffected by moisture in the sample, ambient humidity, or ambient temperature fluctuations. It is also immune to sensor poisoning. Ions associated with dominant sample components, such as ethanol in wine, can be ignored and ions that model only the critical factors that differentiate samples are used. Also, ions present in an unusual sample that are not part of a standard sample can be detected. The use and popularity of multivariate analysis has increased due to the availability of fast computers with virtually unlimited memory coupled with instruments such as a mass spectrometer that generate megabytes of data quickly. The advances in computer and instrumental technology result in complex data sets where useful information needs to be extracted. For example, a normal mass spectrum could consist of over 250 m/z fragments. These m/z ions carry information that could be used as a fingerprint for a certain compound. In order to easily compare different fingerprints a model with fewer dimensions, less than 250, is needed. Figure 1a. Gerstel ChemSensor. Figure 1b. Gerstel ChemSensor System. AN/2003/04-2

EXPERIMENTAL A: Wine. Merlot and Cabernet Sauvignon wine samples from the same winery were purchased at a local store. Pure samples along with three different blends were prepared according to Table 1. The goal of this experiment was to create models that could predict if an unknown was a pure wine (either merlot or cabernet) or a blend. Table 1. Levels used for wine mixtures. Level % Merlot % Cabernet 1 0 100 2 30 70 3 50 50 4 70 30 5 100 0 B: Orange juice. Orange juice samples were purchased at a local store. Diacetyl standard was obtained from Sigma-Aldrich (Allentown, PA). Solutions of diacetyl in water at 10,000 and 2,000 ppm were used to spike orange juice at 10, 50, 100, 500 and 2000 ppm levels. The goal of this experiment was to detect diacetyl in an orange juice matrix. C: Beer. Five different German Pilsner beer samples were purchased in Mülheim an der Ruhr, Germany. All samples were purchased in glass bottles, the Koenig beer was also purchased in the can form. SPME extractions were carried out using a 75 μm Carboxen/PDMS fiber (CAR/PDMS). Headspace SPME extractions were carried out for 15 min at 45 ºC and the fiber was desorbed for 3 min at 220 ºC. The objective of these experiments was to discriminate between the different beer samples and to detect differences in chemical composition in beers aged 3 and 6 days. RESULTS AND DISCUSSION A: Wine. The mass spectral fingerprint of the two different wines was obtained and it is shown in Figure 2. It can be seen that the profiles are pretty similar but there are some subtle differences in some ion ratios (e.g. 61, 92). 40000 700 49 55 A 600 500 60 30000 400 70 300 91 20000 200 100 65 73 101 122 129 60 50 110 70 80 100 120 m/z--> 90 130 10000 Time--> 0.50 0.60 0.70 0.80 0.90 55 49 40000 700 600 B 500 60 30000 400 70 300 200 91 101 20000 100 65 73 122 129 60 50 110 70 80 100 120 m/z--> 90 130 10000 Time--> 0.50 0.60 0.70 0.80 0.90 Figure 2. TIC and MS for A) merlot and B) cabernet wine obtained using the Gerstel Headspace ChemSensor. AN/2003/04-3

Exploratory analysis was carried out using principal component analysis (PCA) and hierarchical cluster analysis. These analyses indicate the feasibility of the data for possible classification or regression analysis. The projection of the samples into the space of the first three principal components is shown in Figure 3. A cascading model was created for these types of samples in which the first model (KNN) classified the samples as either pure or as a blend, if the samples were classified as a blend then a PLS model was used to predict the percentage of blending. Factor2 Blends Merlot Factor3 Factor1 Cabernet Figure 3. Projection of the wine solutions into the space of the first three principal components. The output for a testing data set (not used in model creation) using the cascading models is shown in Table 2. It can be seen that the predictions are 100% accurate when the model predicts as Cabernet or Merlot. For the blended samples we decided to examine the standard error of calibration (SEC, 4.01) obtained with an 3-factor PLS model and the r cal (0.996). Both diagnostic values indicate that the PLS model (Figure 4) could be used in the prediction of blending. AN/2003/04-4

Table 2. Predictions for a wine testing data set using a cascading model. % Merlot Class Predicted Known [% Merlot] 37.28 Blend 30 69.12 Blend 70 27.92 Blend 30 1 100% Cabernet 0 39.58 Blend 50 1 100% Cabernet 0 41.77 Blend 50 53.77 Blend 50 1 100% Cabernet 0 1 100% Cabernet 0 63.94 Blend 70 64.89 Blend 70 1 100% Cabernet 0 M100 M100 M100 M100 M100 Pred Cal 80 40 M30 M30 M30 M30 M30 M50 M50 M50 M50 0 M0 M0 M0 M0 0 40 80 Measured Y Figure 4. Y-Fit for a PLS 3 factor regression model for the wine mixtures. AN/2003/04-5

B: Orange juice. The mass spectra of each of the orange juice samples were examined using the Data Analysis program of ChemStation software (Agilent Technologies). The presence and identification of diacetyl at the 100 ppm concentration was corroborated by subtracting the mass spectrum of a spiked sample minus the spectrum of the non-spiked sample. Figure 5 shows how it is possible to detect with ChemStation Data Analysis software the presence of diacetyl. 44 40 A 40 44 B Intensity 34 m/z--> 30 40 50 60 70 80 53 67 77 79 93 86 90 Intensity m/z--> 34 53 67 77 79 93 30 40 50 60 70 80 90 43 C 43 O D Intensity Intensity O 86 m/z--> 67 53 79 86 93 30 40 50 60 70 80 90 Figure 5. Mass spectra of orange juice. A) OJ with 100ppm diacetyl; B) pure OJ; C) subtraction of pure OJ from OJ with diacetyl; D) diacetyl standard. m/z--> 40 50 60 70 80 90 A PCA model was created to determine if the presence of diacetyl was possible. As seen in Figure 6, PCA scores for the orange juice samples indicate that the first PC (horizontal axis in Figure 6) describes the difference between samples containing marker (positive scores on the first PC) and no marker (negative scores). 2 Factor2 0 O0 O0 O500 O50 O500 O50 O1000 O1000-2 Non-spiked spiked -3-1 1 Factor1 Figure 6. Projections of the orange juice mass spectra into the space of the first two principal components. AN/2003/04-6

C: Beer. The beer samples were analyzed using a GERSTEL ChemSensor System. This configuration allows switching between rapid screening and comprehensive GC/MS analysis depending if a short transfer line or a capillary column is on-line. Figure 7 shows six TICs obtained using this configuration in the SPME mode. Visual inspection of these five TICs reveals few differences between these six types of beers. Krombacher Time--> 5.00 10.00 15.00 Warsteiner Time--> 5.00 10.00 15.00 Veltins Time--> 5.00 10.00 15.00 Koenig Pilsener (bottle) Time--> 5.00 10.00 15.00 Brinkhoffs No.1 Time--> 5.00 10.00 15.00 Koenig Pilsener (can) Time--> 5.00 10.00 15.00 Figure 7. GC-MS total ion chromatograms of the different beer types. AN/2003/04-7

Since visual separation of the samples using TIC is difficult, the mass spectral fingerprint was used to develop chemometric models. Figure 8 shows the projection of the mass fingerprints into the space of the first three principal components. The total variance captured within the first three principal components was over 98%, this implies that differences in the samples projections are due to differences in the chemical composition obtained with SPME sampling. Five different clusters are evident in the scores plot (Figure 8), beer sampled from the can and bottle appears to cluster together. A separate model was created for this type of beer (inset of Figure 8) in which separation was obtained using 3 PCs. Factor4 Factor2 Factor1 Koenig Pilsener (bottle) Koenig Pilsener (can) Factor2 Brinkhoffs No. 1 Koenig Pilsener (can) Factor3 Koenig Pilsener (bottle) Warsteiner Factor1 Krombacher Veltins Figure 8. PCA scores plot (4 factors) of the 6 beers fingerprint mass spectra. Change in composition as the beer aged was easily detected using the GERSTEL ChemSensor system. Figure 9 shows the projection of the fresh and aged Warsteiner beer into the space of the first two principal components. Examination of the corresponding loadings for these PCs reveals key ions responsible for the different projections. Using these ions as a guide, extracted ion chromatograms were inspected using ChemStation Data Analysis software. AN/2003/04-8

3.000 2.000 Aged-6 days Aged- 3 days Fresh Factor2 (E +06) 1.000 0.000-1.000-2.000-2.000 0.000 2.000 Factor1 (E +07) Figure 9. Projections of the mass spectral fingerprints of Warsteiner aged beers into the space of the first two principal components. Table 3 shows the compounds that decrease over time as the Warsteiner beer was aged. Ions with high loadings for the first PCs are highlighted. It appears that the first principal component in this case is explaining the difference between the content of the compounds from Table 3 in the different aged samples. Since the GERSTEL ChemSensor System includes a GC, detection of the specific compound is easily done when a capillary column with slow temperature ramp is used. Table 3. Compounds that decrease overtime as the Warsteiner beer was aged. Ions highlighted have high loadings in the first principal component. RT [min] Compound CAS # Ions 1.00 Ethyl acetate 141-79-6 43, 61, 70, 88 3.11 1-Butanol-3-methyl acetate 123-92-2 43, 55, 70, 61 5.05 Ethyl caproate 123-66-0 60, 71, 88, 99 9.71 Octanoic acid ethyl ester 106-32-1 88, 101, 127, 57 CONCLUSIONS The fast and accurate classification of samples using an instrument that integrates multivariate statistics with mass spectrometry technology is now possible. The GERSTEL Headspace ChemSensor and GERSTEL ChemSensor System have both been proven to be capable of detecting differences in the composition of three beverages: wine, orange juice and beer. For the wine samples, it has been shown that it is possible to develop cascading models that can predict wine samples as pure or blends using the GERSTEL Headspace ChemSensor. The blending percentage was also possible to predict with a PLS model. For the orange juice study, these preliminary results indicate the possibility of using a mass spectral based chemical sensor to predict the level of diacetyl. More research with more markers and more levels is necessary. Also, the possibility of using the Chemical sensor in the single ion-monitoring mode (SIM) could improve the sensitivity below 10 ppm. Finally, it has been shown that visual comparison of total ion chromatograms of beer samples was cumbersome. Comparison of chemical composition is more objective and faster using a GERSTEL ChemSensor System with multivariate analysis. AN/2003/04-9

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 Digital Drive, Suite J Linthicum, MD 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 gerstelag@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower One Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability