Olea Head and Neck DCE VPMC-14290A

Similar documents
Olea Tumor Basic VPMC-13988A

Activity 10. Coffee Break. Introduction. Equipment Required. Collecting the Data

1. Installation 2. Transferring a Stackup from Altium Designer 3. Transferring a Stackup and Design Rules to Altium Designer

AWRI Refrigeration Demand Calculator

Application & Method. doughlab. Torque. 10 min. Time. Dough Rheometer with Variable Temperature & Mixing Energy. Standard Method: AACCI

PRODUCTION SOFTWARE FOR WINEMAKERS. Wine Operations and Laboratory Analyses

NVIVO 10 WORKSHOP. Hui Bian Office for Faculty Excellence BY HUI BIAN

Directions for Menu Worksheet. General Information:

Tamanend Wine Consulting

Most Affordable Professional Grade 2D & 3D CAD Software

User s Manual. User s Manual Version 1.0. Chulalongkorn University. Raks Thai Foundation. Worcester Polytechnic Institute. January 29 th, 2013

COMSTRAT 310 Semester-Long Project Part Three

Evaluation copy. Falling Objects. Experiment OBJECTIVES MATERIALS

Table Reservations Quick Reference Guide

Let s Eat! To Place an Order

Biocides IT training Vienna - 4 December 2017 IUCLID 6

How to Make a PB & J Sandwich

PROGRAMMING MANUAL. Sure Immersion 220 Bean-To-Cup, Single Serve, Air Infusion Brewer

Unit of competency Content Activity. Element 1: Organise coffee workstation n/a n/a. Element 2: Select and grind coffee beans n/a n/a

Programming Guide For EXTRACTOR Coffee Brewers (CBS 2000e Series)

Organic Chemistry 211 Laboratory Gas Chromatography

iworx Sample Lab Experiment GB-4: Ecological Balance

Welcome to Grubhub. Table of contents. You ve joined the nation s leading online and mobile food ordering platform. Set up your account...

Barista at a Glance BASIS International Ltd.

longer any restriction order batching. All orders can be created in a single batch which means less work for the wine club manager.

LABORATORY INVESTIGATION

Let s Eat! To Place an Order

PRODUCT EXAMPLE PIZZA

Getting the Most from Beer Brewing Software. Brad Smith, PhD

Falling Objects. computer OBJECTIVES MATERIALS

IKAWA App V1 For USE WITH IKAWA COFFEE ROASTER. IKAWA Ltd. Unit 2 at 5 Durham Yard Bethnal Green London E2 6QF United Kingdom

Design a Coffee Mug Step 1

Vigilant DIY Wine Cellar Planner How-To Instructions

RELEASED FOR PRODUCTION PROGRAMMING MANUAL

Step 1: Prepare To Use the System

Route List Configuration

1. Continuing the development and validation of mobile sensors. 3. Identifying and establishing variable rate management field trials

Directions for Menu Worksheet ***Updated 9/2/2014 for SY *** General Information:

Cocktail Keyboard + Node

GROW YOUR BUSINESS WITH ONTARIO GO-TO- MARKET PROGRAM WINTER 2008

Biocides IT training Helsinki - 27 September 2017 IUCLID 6

SPATIAL ANALYSIS OF WINERY CONTAMINATION

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

Caffeine in Energy Drinks

Greenhouse Effect Investigating Global Warming

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Greenhouse Effect. Investigating Global Warming

Route List Setup. About Route List Setup

Thank you for purchasing cake templates designed by:

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

PDF # ROTISSERIE COOKING TIME CHART EBOOK

Software engineering process. Literature on UML. Modeling as a Design Technique. Use-case modelling. UML - Unified Modeling Language

Munis Self Service. Employee Self Service User Guide Version For more information, visit

What s New? AlveoLab, SRC-CHOPIN, Mixolab 2. CHOPIN Technologies Geoffroy d Humières

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

Determination of Caffeine in Coffee Products According to DIN 20481

Marketing. Promotion Guide

S uper A utomatic C offee M achines

User guide supplement. Built-in oven NZ AU. Soft Touch electronic models

Shop for Healthy Groceries

Caffeine And Reaction Rates

MODELS 1315 & 1315-S La Pavoni CLUB COMBO

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

GENETICALLY MODIFIED SOYBEANS VERSUS TRADITIONAL SOYBEANS HOW DO THEY COMPARE?

Digital Menu Boards Overview

Charlie to Go Online Ordering Guide

T raditional C offee M achines

Administration Guide HighSpeedWaiter.com

Setting Up the TEXAS WINE CALENDAR by Natalia Kolyesnikova, Ph.D.

User Studies for 3-Sweep

Calibrate grill heat zones Monthly GR 1 M1

G F I M J K L B C D E S O T H Q P U N R D 4

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

GCSE 4091/01 DESIGN AND TECHNOLOGY UNIT 1 FOCUS AREA: Food Technology

Lab: Groundwater. Prediction: Which sample (4mm, 7mm, 12mm) will have the greatest porosity?

Mosaic Stadium Suites and Loge Seats Premium Experience Online Ordering Tool User Guide

ESPRESSO. Esprecious FreshMilk. The taste of quality worldwide

Lesson 23: Newton s Law of Cooling

Experiment # Lemna minor (Duckweed) Population Growth

Smart Plunger TM by PCS

Slide 1. Slide 2. A Closer Look At Crediting Fruits. Why do we credit foods? Ensuring Meals Served To Students Are Reimbursable

Simulation of the Frequency Domain Reflectometer in ADS

Alcohol Meter for Wine. Alcolyzer Wine

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

Identification of Adulteration or origins of whisky and alcohol with the Electronic Nose

INSTALLATION AND OPERATING MANUAL BUNN-O-MATIC CORPORATION

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

IT tool training. Biocides Day. 25 th of October :30-11:15 IUCLID 11:30-13:00 SPC Editor 14:00-16:00 R4BP 3

THE APPLICATION OF NATIONAL SINGLE WINDOW SYSTEM (KENYA TRADENET) IN PROCESSING OF CERTIFICATES OF ORIGIN. A case study of AFA-Coffee Directorate

Jake Bernstein Trading Webinar

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

For Beer with Character

PLEASE TAKE THE TIME TO READ THROUGH THIS FOR IMPORTANT POINTERS ON HOW TO MAXIMIZE YOUR TIME AND SEARCHES ON THE DATABASE.

Roux Bot Home Cooker. UC Santa Cruz, Baskin Engineering Senior Design Project 2015

The 2006 Economic Impact of Nebraska Wineries and Grape Growers

TEACHER NOTES MATH NSPIRED

STACKING CUPS STEM CATEGORY TOPIC OVERVIEW STEM LESSON FOCUS OBJECTIVES MATERIALS. Math. Linear Equations

Equipment Yield Chart

Programmable Conical Burr Mill CBM-18

Transcription:

Olea Head and Neck DCE VPMC-14290A

Olea Head and Neck DCE: Overview Olea Head and Neck DCE provides the following: Automatic or manual background segmentation Automatic or manual arterial input function selection Motion Correction Two DCE Models - Tofts & Kermode or Extended Tofts Computation of qualitative dynamic curve maps: Wash-in - Initial up-slope of the concentration time curve Wash-out - Down-slope of the concentration time curve AUC - Area under the curve TME - Time to maximum enhancement Peak - Peak enhancement Computation of quantitative permeability maps: Ktrans- Rate constant for transfer of contrast agent from plasma to extravascular, extracellular space Kep - Rate constant for transfer of contrast agent from extravascular, extracellular space to plasma VP - Plasma volume VE - Fraction volume of extravascular, extracellular space 2

Olea Head and Neck DCE- Workflow The Steps: Open Vitrea software and select patient Launch the application In the Olea Application tab: Check the Manual Series identification box if needed In the workflow tab: Click on Head and Neck DCE Select the Permeability series Review Permeability curve as needed Add conventional sequences as needed Click on mono-slice analysis tab and perform ROI analysis Click on Step 3 (in Olea workflow tab) for export 3

Olea Head and Neck DCE- Select Study Launch Vitrea Left mouse click to select the patient. Select the Applications tab. Double left mouse click on Olea Sphere. 4

Olea Head and Neck DCE - Protocol Click on the Applications tab. Check the box for Manual Series identification. Tip: By checking the manual series identification box, it allows the user to pick which series to use. The program will learn and remember based on series descriptors. 5

Olea Head and Neck DCE - Protocol Click on the Workflows tab. Click Head & Neck (DCE analysis). 6

Olea Head and Neck DCE - Selecting Series Select the Permeability Series from the left column and move to the right column by clicking the arrow. After moving the series to the right column, click the check at the bottom of the page. Repeat for the Conventional sequences. Tip: If the series resides in the right column, verify they are correct and click the check mark. 7

Olea Head and Neck DCE - Tools To scroll through any of the data sets: click on the image and roll the middle mouse. To scroll through time on the permeability data, left mouse click on the slider bar and move left & right. To magnify an image, hold down the shift key and roll the middle mouse. To pan an image, hold down the left mouse. 8

Olea Head and Neck DCE - Analysis Click on the Mono slice analysis tab. 9

Olea Head and Neck DCE - Permeability. Move the mouse over the maps to make the corner tools active. When the image is active, options will appear in each corner of the image. 10

Olea Head and Neck DCE - Analysis Tools Key images, Link, Pan/Zoom, Automatic windowing. ROIs, arrows, rulers, Magic Wand, Bi-ruler and the Reference ROI. Axial, Sagittal and Coronal orientation options. Multiple ROI Templates, export overlays as DICOM. 11

Olea Head and Neck DCE - Midline To edit the Midline, zoom out, left click on midline. Drag or move the line or white boxes at the top or bottom.. Olea software will mirror ROIs when Midline is on. To turn off Midline left click on the Midline button. 12

Olea Head and Neck DCE - ROI Analysis Move the mouse over the maps to make the corner tools active. Select appropriate ROI tool and draw a ROI on the map of interest. 13

Olea Head and Neck DCE - Maps and Overlays Click on the drop down arrow above the image to change which map is displayed. Add a second image to the overlay by clicking on the drop down arrow below the image. Slider bar adjusts the transparency. Click on Step 3: Export when completed the analysis.

Olea Head and Neck DCE - Export and Overlays export all numerical values, To check the Sum up Array. To export images with ROI s and measurements, check the Key images. To export series and/or maps: click on the desired series to export. When finished check Save. Tip: click on the eye to view what will be exported. 15

Olea Head and Neck DCE - Export Click Back to Vitrea to exit. ** For Additional Procedures see next slides. 16

Olea Head and Neck DCE - Permeability To view the DCE computation, click on Step 1. 17

Olea Head and Neck DCE - Permeability Permeability is automatically processed. 18

Olea Head and Neck DCE - Permeability Options Signal Conversion- Drop down menu for additional options. Background segmentation- Applied by default- can be manually adjusted with the slider bar. Motion correction- Applied by default. Spatial Smoothing-Off by default.. **For additional explanation of permeability options, access the HELP tab in the Vitrea software, under partner integrations, Olea Sphere. (pages 55-59) 19

Olea Head and Neck DCE - Permeability Options Signal-Adjust the Baseline and Range on the Concentration time curve. You can exclude time points using range. AIF- (Arterial input function) Automatically performed. Concentration time curveorange slider bar below graph can be used to put values of the AIF to 0. DCE Model- Tofts & Kermode or Extended Tofts. Tools- Capture Options. Vitrea software is manufactured by Vital Images 20