Ti-Pure TITANIUM DIOXIDE DETERMINATION OF UNBRUSHED 325 MESH GRIT, SLURRY METHOD: T

Similar documents
Introduction to the General Chemistry II Laboratory. Lab Apparatus and Glassware

Chapter 14 Tex-619-J, Analysis of Water for Chloride and Sulfate Ions

Introduction to Measurement and Error Analysis: Measuring the Density of a Solution

FAT, TOTAL (Hydrolysis)

Lab 2-1: Measurement in Chemistry

Copyright JnF Specialties, LLC. All rights reserved worldwide.

EXPERIMENT NO. 3 HYDROMETER ANALYSIS ASTM D-422

Mastering Measurements

Separating the Components of a Mixture

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

EXTRACTION OF SEDIMENTS FOR AROMATIC AND CHLORINATED HYDROCARBONS

IPPA SAG method revision 0,

Chemistry 212 MOLAR MASS OF A VOLATILE LIQUID USING THE IDEAL GAS LAW

Gravimetric Analysis

Separating the Components of a Mixture

Coffee-and-Cream Science Jim Nelson

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

1. Blender: Osterizer, 10-speed, or equivalent. 2. Separatory Funnel: Kilborn or equivalent (see figure 1) 2. HCl Solution: HCl/water (7:93 by volume)

Copyright JnF Specialties, LLC. All rights reserved worldwide.

Separation of a Mixture

Draft for comments only Not to be cited as East African Standard

Standard Operating Procedure (SOP) for Quartz dissolution in Hydrofluoric Acid

PECTINASE Product Code: P129

Separating the Components of a Mixture

Roast Beef Jan. 1, 2009

The Separation of a Mixture into Pure Substances

Buying Filberts On a Sample Basis

HOW MUCH DYE IS IN DRINK?

INSTALLATION AND OPERATING INSTRUCTIONS

PART I CENTRIFUGE EXTRACTION METHOD USING CHLORINATED SOLVENT

Automatic proofers. Member of the

Selecting, Preparing, and Canning Vegetables and Vegetable Products

C27 Chromatography. Collect: Column Mortar and pestle Dropper (229 mm) Capillary tube TLC plate Aluminum foil UV light

Aroma Fresh. Instructions for use Includes recipes. Model BCM120

Application Note No. 184/2015

Overview. Hydrometer Selection. About Specific Gravity. Conditions Affecting Hydrometer Accuracy

EXPERIMENT 6. Molecular Fluorescence Spectroscopy: Quinine Assay

5 Litre Party Keg Manual

Student Handout Procedure

ISO INTERNATIONAL STANDARD. Oilseed residues Determination of oil content Part 2: Rapid extraction method

Tomato Product Cutting Tips

5KCM0512A W A_ENv10.indd 1 10/13/15 12:41 PM

IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE, DO NOT OPERATE THIS PRODUCT!

Gravimetric Analysis

SYNTHESIS OF SALICYLIC ACID

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

Experiment 2: ANALYSIS FOR PERCENT WATER IN POPCORN

Make Your Own Yogurt Zoe A. Godby Lightfoot

EDICT ± OF GOVERNMENT

Experiment 3: Separation of a Mixture Pre-lab Exercise

Preparation of mechanical pulps for testing (Revision of T 262 sp-02)

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

THE EFFECTS OF FINAL MOLASSES AND SUGAR PURITY VALUES ON THE CALCULATION OF 96 0 SUGAR AND FACTORY RECOVERY INDEX. Heera Singh

Total Dissolved Solids: Environmental Express StableWeigh Analytical Testing Vessels. Dr. Edward F. Askew June 15, 2016

Problem How does solute concentration affect the movement of water across a biological membrane?

EDICT ± OF GOVERNMENT

UNITED STATES STANDARDS FOR WHOLE DRY PEAS¹

BBQ Ribs. Loaded Potato Salad Marinated Three Bean Salad Cornbread Peach Pie

Tomatoes LET S PRESERVE

2. Other constituents in the sample solution should not interfere with the precipitation of the component of interest.

TISSUE PREPARATION FOR LASER MICRODISSECTION (LCM) WITH ETHANOL:ACETIC ACID FIXATION

In the preparation of this Tanzania Standard assistance was derived from:

EDICT ± OF GOVERNMENT

Collecting, Drying, and Storing Chestnut Anthers Version 2.0

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

I. INTRODUCTION I ITEMS:

CHEM Experiment 4 Introduction to Separation Techniques I. Objectives

Egg-cellent Osmosis Lab

Test sheet preparation of pulps and filtrates from deinking processes

PERSONAL HEALTH AND HYGIENE POLICY

Features. Before first use

Application Note. Hydrolysis Unit E-416, Extraction Unit E-816 Soxhlet. Fat determination according to Weibull-Stoldt - Standard application

Year 8 Food Technology. Go Crazy With Cakes. Recipe Booklet

Make Holiday or Themed Cookies

TEMPORARY FSO/RFE APPLICATION AND GUIDELINES

BBQ Grill. Owner s Manual Save These Instructions - For Household Use Only For Sizes: 12 x 18 & 12 x 12

FOOD PRESERVATION 101

LAB: One Tube Reaction Part 1

Canning. Freezing Tomatoes. and. General Considerations. Safety. FN-175 (Revised) Julie Garden-Robinson Food and Nutrition Specialist

National Food Safety Standard

Guide 4, Selecting, Preparing, and Canning Vegetables and Vegetable Products

3. Aspirin Analysis. Prelaboratory Assignment. 3.1 Introduction

HI-1017: Pharmacy Technician. Module 10 Pharmacy Equipment

AUTOMATIC BURR COFFEE GRINDER

SAFETY INSTRUCTIONS FOR USE

HARVEST & POST-HARVEST PRACTICES. Harvest Fermentation Drying Micro-fermentation HARVESTING FERMENTATION

Title: Reagents Copy No: ## SOP No.: 3.13/3.1/S Effective Date: July 8, 2013 Location: ### Reagents

TOASTER OVEN USER MANUAL MODEL: PKMFT039

Let s Preserve. Tomatoes. Bulletin #4085. Recommended Varieties. Quantity. Table 1. Quantities of Fresh Tomatoes Needed for Tomato Products

Roundup Ready CP4 EPSPS PathoScreen kit for the detection of CP4 EPSPS protein Peroxidase Label Catalog number: PSP 74000

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

Caffeo. Italian style espresso machine. INSTRUCTIONS FOR USE. Breville Customer Service Centre

Barriers to Bare Hand Contact

Determination of Alcohol Content of Wine by Distillation followed by Density Determination by Hydrometry

Canning and Preserving the Harvest FALL 2018

Product Name: Micro Pack

Activity Booklet. Hazel Rymer

Year 8 Food Technology: Recipe Book

Draft Indian Standard SPICES AND CONDIMENTS - CORIANDER, WHOLE AND GROUND - SPECIFICATION (Third Revision)

Let s Preserve. Table 1. Recommended Processing Times in a Boiling-Water Canner for Jellies, Jams, and Spreads

Transcription:

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF UNBRUSHED 325 MESH GRIT, SLURRY METHOD: T4400.300.01

DuPont Titanium Technologies Page 2 of 5 1. Principle A slurry sample of known percent solids is diluted with water. The slurry is transferred to a 325-mesh sieve. The undersize is washed through the sieve with an unspecified volume of water. The oversize is dried, weighed, and reported as unbrushed +325 mesh grit. 2. Applicability 2.1. General This method is used to determine the percent unbrushed +325 mesh grit in a slurry of titanium dioxide. 2.2. Specific This method is used to determine the percent unbrushed grit of a rutile slurry which is the total of the hard grit (brushed) and the soft agglomerates. The method can be used for process control and product specification. 3. Limitations This method was revised to be similar to the brushed grit procedure and for ISO clarification. 4. Sensitivity, Precision and Accuracy 4.1. Sensitivity No data is available. 4.2. Precision 4.2.1. Single Operator The average analysis ( x ), standard deviation (s), and 95% confidence limits (95% CL) established for the single operator precision of the method were as follows: x s 95% CL % 325 Mesh Grit 0.0076 0.0014 ± 0.0027 The above data were calculated from eight replicate analyses of one sample performed by one technician over a period of several days. 4.2.2. Multiple Operator The average analysis ( x ), standard deviation (s), and 95% confidence limits (95% CL) established for the multiple operator precision of the method were as follows: x s 95% CL % 325 Mesh Grit 0.0081 0.0016 ± 0.0031 The above data were calculated from twenty replicate analyses of one sample performed by five technicians over a period of several days. 4.3. Accuracy No data are available; however, our experience with the test has been satisfactory. 5. Special Apparatus (Equivalent apparatus may be substituted)

DuPont Titanium Technologies Page 3 of 5 5.1. Sieve, Paint Pigment, ASTM 325 mesh, 3 inch, National Bureau of Standards Series No. 325., 3 inch diameter. VWR Scientific No. 57377-009. Order from local VWR sales office. 5.2. Electric convection oven at 110 ± 5 C, not forced air. 5.3. Camel's hair balance brush. Fisher Scientific Co., ½ inch," Flat Camel Hair Brush", Cat. No. 03-665A. 5.4. Analytical balance. 5.5. Top loading balance (capable of weighing 200 g ± 0.1 g). 5.6. Disposable cold drink cups, at least 300 ml capacity. Obtain locally. 6. Reagents (Reagent grade except as noted) 7. Special Safety Considerations 7.1. Product Hazards There are no unusual product hazards. Normal care to prevent dusting, eye contact or skin contact is suggested. Wipe up all spills with a damp paper towel. For more information, refer to MSDS #2816CR. 7.2. Procedure Hazards 8. Procedure 7.2.1. Use care with glass ware. Check for cracks and chips before using. 7.2.2. Use tongs or gloves when handling hot equipment. 8.1. Operating Conditions Not applicable. 8.2. Calibration Not applicable. 8.3. Sampling Samples are normally supplied by manufacturing. Slurries should be tested promptly because changes in properties can occur with time. 8.4. Sample Analysis 8.4.1. Determine percent solids of the slurry sample using the method described in T4400.570.01.WP (formerly TP-508.1). 8.4.2. On a top loading balance tare a clean paper cup or beaker containing approximately 100 ml of distilled water. 8.4.3. Weigh 200 ± 1 g of slurry into the paper cup or beaker containing the water, using care not to get any dried solids from the rim of the slurry container

DuPont Titanium Technologies Page 4 of 5 8.4.4. Slowly pour diluted slurry into a clean 3 inch, 325-mesh sieve. Occasionally tap the sieve frame lightly to aid the passage of the fines through the sieve. NOTE: Visually inspect 325-mesh sieve for holes, tears or any other damage before use. 8.4.5. Thoroughly rinse the paper cup or beaker with distilled water and pour onto the sieve. Rinse cup or beaker until all pigment and grit are removed, adding all washings to the sieve. 8.4.6. Wash sieve with a gentle stream of water until underflow is clear. 8.4.7. Wash residue to one side of the sieve. 8.4.8. Dry sieve in a 110 ± 5 C oven (not forced air) for at least 30 minutes or until dry. 8.4.9. Remove sieve from oven and cool to room temperature in a desiccator. Use tongs or gloves to handle the hot sieve. 8.4.10. Transfer the dried residue to a tared weighing dish using a dry camel's hair balance brush. 8.4.11. Weigh the residue (and dish) on an analytical balance to the nearest 0.0001 g. and record weight. Alternate steps may be used: 8.4.11. a. Weigh the cool sieve containing the solids on an analytical balance to the nearest 0.0001g. and record the weight. 8.4.12. a. Brush the dried residue from the sieve using a dry camel hair brush. 8.4.13. a. Reweigh the empty sieve and calculate and record the difference as the weight of grit. 8.5. Calculations 8.5.1. Calculate percent grit (TiO 2 basis) as follows. weight of grit % Unbrushed Grit = 0.02 % solids of slurry This formula was derived from the more general formula which is written: weight of grit 100 % Grit = % solids sample wt. 100 9. Quality Control No slurry samples with known grit are available for Statistical Process Control Procedures. 10. Comments

DuPont Titanium Technologies Page 5 of 5 10.1. General 10.2. Specific 11. References 11.1. General 11.1.1. ASTM D 185-84. 11.1.2. ASTM D 476-84. 11.1.3. MSDS No. 2816CR for Titanium Dioxide.