Wideband HF Channel Availability Measurement Techniques and Results W.N. Furman, J.W. Nieto, W.M. Batts

Similar documents
MBA 503 Final Project Guidelines and Rubric

COMPARISON OF CORE AND PEEL SAMPLING METHODS FOR DRY MATTER MEASUREMENT IN HASS AVOCADO FRUIT

PARENTAL SCHOOL CHOICE AND ECONOMIC GROWTH IN NORTH CAROLINA

Allergy Relief Latest trends & developments in remedies for nasal, skin and eye allergy symptoms and asthma

Mobility tools and use: Accessibility s role in Switzerland

Global Hot Dogs Market Insights, Forecast to 2025

Alcohol Meter for Wine. Alcolyzer Wine

Global Rum Market Insights, Forecast to 2025

Name: Class: Date: Secondary I- CH. 10 Test REVIEW. 1. Which type of thin-crust pizza was most popular?

2016 China Dry Bean Historical production And Estimated planting intentions Analysis

FURUNO Multi-GNSS Disciplined Oscillator

EWWR good practices and case studies

5 Populations Estimating Animal Populations by Using the Mark-Recapture Method

Foodservice EUROPE. 10 countries analyzed: AUSTRIA BELGIUM FRANCE GERMANY ITALY NETHERLANDS PORTUGAL SPAIN SWITZERLAND UK

Simulation of the Frequency Domain Reflectometer in ADS

STATE OF THE VITIVINICULTURE WORLD MARKET

EXECUTIVE SUMMARY OVERALL, WE FOUND THAT:

Perspective of the Labor Market for security guards in Israel in time of terror attacks

Coffee zone updating: contribution to the Agricultural Sector

World Yoghurt Market Report

Overview of the Manganese Industry

Fresh Deciduous Fruit (Apples, Grapes, & Pears): World Markets and Trade

openlca case study: Conventional vs Organic Viticulture

ICC July 2010 Original: French. Study. International Coffee Council 105 th Session September 2010 London, England

The state of the European GI wines sector: a comparative analysis of performance

THIRSTY ASIA A MARKET ANALYSIS. Presentation by Richard Hall Chairman, Zenith International Ltd. AUSDRINKS 21 March 2016, Sydney

Industry Advisory Panel Item 4c Trade of Stainless Steel Scrap

Notes on the Philadelphia Fed s Real-Time Data Set for Macroeconomists (RTDSM) Capacity Utilization. Last Updated: December 21, 2016

TOURIST SPECIAL INTEREST WINE TOURISM NEW ZEALAND FEBRUARY 2014

STATE OF THE VITIVINICULTURE WORLD MARKET

ANALYSIS ON THE STRUCTURE OF HONEY PRODUCTION AND TRADE IN THE WORLD

1. Continuing the development and validation of mobile sensors. 3. Identifying and establishing variable rate management field trials

Company Coverage. Country Coverage. Global Coverage. Regional Coverage

Step 1: Prepare To Use the System

The Future of the Confectionery Market in South Africa to 2019

Fromage Frais and Quark Market in Portugal: Market Profile to 2019

ICC September 2018 Original: English. Emerging coffee markets: South and East Asia

Supply & Demand for Lake County Wine Grapes. Christian Miller Lake County MOMENTUM April 13, 2015

Market Implications for GM Crops

Title: Western New York Sweet Corn Pheromone Trap Network Survey

ECONOMICS OF COCONUT PRODUCTS AN ANALYTICAL STUDY. Coconut is an important tree crop with diverse end-uses, grown in many states of India.

DERIVED DEMAND FOR FRESH CHEESE PRODUCTS IMPORTED INTO JAPAN

North America Ethyl Acetate Industry Outlook to Market Size, Company Share, Price Trends, Capacity Forecasts of All Active and Planned Plants

INNOVATIVE SOLUTIONS POWERING YOUR SAFETY SUCCESS

The Future of the Ice Cream Market in Finland to 2018

Precautionary Allergen Labelling. Lynne Regent Anaphylaxis Campaign

TRTP and TRTA in BDS Application per CDISC ADaM Standards Maggie Ci Jiang, Teva Pharmaceuticals, West Chester, PA

Firebox X Edge e-series Hardware

Assessment of the CDR BeerLab Touch Analyser. March Report for: QuadraChem Laboratories Ltd. Campden BRI Group contracting company:

IFPTI Fellowship Cohort V: Research Presentation Matthew Coleman, R.S., CP-FS

Use of Accelerated Solvent Extraction (ASE) with Centrifugal Evaporation to Automate Fat Determination in Chocolate

OIV Revised Proposal for the Harmonized System 2017 Edition

J / A V 9 / N O.

The. Strauss Group. Company Presentation April 2015

Which of your fingernails comes closest to 1 cm in width? What is the length between your thumb tip and extended index finger tip? If no, why not?

Global Grape Report JUI CE P RODU C TS A S SOCI ATION FA L L BU S I N ESS M E E TING N OV E MBER 5,

US Foods Online and Mobile App Technology Update

IT 403 Project Beer Advocate Analysis

Fromage Frais and Quark (Dairy and Soy Food) Market in Australia - Outlook to 2020: Market Size, Growth and Forecast Analytics

World Cocoa Prices. Commodity Prices Update: Coffee, Cocoa, and Cotton. Joelle Cook and Professor C. Leigh Anderson

Napa County Planning Commission Board Agenda Letter

P E C A N R E P O R T

Buying Filberts On a Sample Basis

Figure S2. Measurement locations for meteorological stations. (data made available by KMI:

Coffee weather report November 10, 2017.

An application of cumulative prospect theory to travel time variability

AST Live November 2016 Roasting Module. Presenter: John Thompson Coffee Nexus Ltd, Scotland

Biologist at Work! Experiment: Width across knuckles of: left hand. cm... right hand. cm. Analysis: Decision: /13 cm. Name

Guidelines for Validation of Dry Roasting Processes

Market, Regulatory & Policy Update for Plant-based Ingredients

Health Effects due to the Reduction of Benzene Emission in Japan

More information from: global-online-food-delivery-and-takeaway-marketanalysis-by-order-type

INTERNATIONAL DAIRY PRODUCTS COUNCIL. Reply to Questionnaire 4. Australia (1988/89) I. Milk. A. Production and Utilization of Milk

A Framework for Processes Submission and Monitoring from Mobile Devices to Grid Configurations Utilizing Resource Matching

Mastering Measurements

WINE MANAGAMENT PLATFORM FOR WAREHOUSES

Missing Data Treatments

THE APPLICATION OF NATIONAL SINGLE WINDOW SYSTEM (KENYA TRADENET) IN PROCESSING OF CERTIFICATES OF ORIGIN. A case study of AFA-Coffee Directorate

Pasta Market in Italy to Market Size, Development, and Forecasts

MyPlate. National FCS Standard: Apply various dietary guidelines in planning to meet nutrition and wellness needs.

Notes on the Philadelphia Fed s Real-Time Data Set for Macroeconomists (RTDSM) Indexes of Aggregate Weekly Hours. Last Updated: December 22, 2016

ANALYSIS OF THE EVOLUTION AND DISTRIBUTION OF MAIZE CULTIVATED AREA AND PRODUCTION IN ROMANIA

An Examination of operating costs within a state s restaurant industry

Environmental Monitoring for Optimized Production in Wineries

Corn and Soybean CORN OUTLOOK SOYBEAN OUTLOOK STATISTICS AND ANALYSIS

Introduction: Aseptic Packaging Market-

Michigan Grape & Wine Industry Council Annual Report 2012

PHILIPPINES. 1. Market Trends: Import Items Change in % Major Sources in %

Whether to Manufacture

Measuring household food waste The Spain experience

AWRI Refrigeration Demand Calculator

Outlook for Global Recovered Paper Markets. Global OCC Market. Global ONP Market RISI. Hannah Zhao, Economist, Recovered Paper October 2012

Global cooking Utensils Market Research Report 2016

WINE EXPORTS. February Nadine Uren. tel:

Abstract. Keywords: Gray Pine, Species Classification, Lidar, Hyperspectral, Elevation, Slope.

Regression Models for Saffron Yields in Iran

Statistics & Agric.Economics Deptt., Tocklai Experimental Station, Tea Research Association, Jorhat , Assam. ABSTRACT

COMPARISON OF THREE METHODOLOGIES TO IDENTIFY DRIVERS OF LIKING OF MILK DESSERTS

For Beer with Character

Seriously, CELIAC. talk.

Transcription:

Wideband HF Channel Availability Measurement Techniques and Results W.N. Furman, J.W. Nieto, W.M. Batts THIS INFORMATION IS NOT EXPORT CONTROLLED THIS INFORMATION IS APPROVED FOR RELEASE WITHOUT EXPORT RESTRICTIONS IN ACCORDANCE WITH A REVIEW OF THE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS (ITAR), 22CFR 120-130, AND THE EXPORT ADMINISTRATION REGULATIONS (EAR) 15 CFR 730-774. harris.com

Overview Background / Goals Channel Availability measurement System Data collection software / Analysis Methodology Results to Date Conclusions and Future Work Acknowledgements 2

Background Updated U.S. MIL-STD 188-110C defines a Wideband HF suite of modem waveforms using bandwidths from 3-24 khz, providing user throughputs of 75 through 120000 bps Automated Cognitive HF systems must, in addition to finding the best channel to use, determine the available bandwidth, which may not be the same as the allocated bandwidth 3

Background II Harris developed an Inexpensive system that could be easily fielded to measure Wideband HF channel availability, this approach to measurement and analysis presented in a Nordic HF13 Conference paper System is passive, monitors received noise and interference Wideband HF of great interest to users, industry, and Governments. Two major approaches US Mil STD is a variable Contiguous Bandwidth scheme France (Thales) developing a multi 3kHz channel approach Both systems are impacted by the availability of HF channels HF Industry Association (HFIA) decided to create a working group to field measurement systems around the world, collect and analyze the data 4

Goals of the HFIA Wideband HF Channel Availability Working Group Field a substantial number of HF wideband channel availability measurement stations in diverse locations worldwide Use common hardware, (SDR and antenna), collection software, and analysis software so that results can be easily and accurately compared between all sites Share the collected data and analysis results among all members of the HFIA Begin testing as soon as possible Present and compare results at HFIA Working Group meetings 5

Channel Availability Measurement System 6

Data Collection Software High Level Overview: Set LO to 2.5 to MHz Set pre-selector Set sample-rate= 2 Ms/s Gather USB samples Use a 4096 pt FFT Kaiser Window FFT Bin = 488.28125 Hz Average 488-(1 sec) Store off middle 2048 pts representing LO-0.5 MHz to LO+0.5Mhz Increase LO by 1.0 MHz Repeat 2-30MHz in 30 secs Repeat every 60 seconds 7

Analysis Methodology I Each sweep observation file processed in 1 MHz segments Measured RX power divided into 3 khz bins A noise floor is calculated by median filtering the spectrum For each 3 khz bin, if the RX power was 10dB above the noise floor it was considered occupied-unavailable Each sweep observation file converted to 9334 values, (1,0) indicating if that 3 khz segment was occupied 8

Analysis Methodology II If a specific 3 khz bin was available for 3 observations in a row it was considered available for the current minute - Channel Minute Availability (CMA) This biases the availability to channels that are relatively unused for a few minutes and not experiencing sporadic use or interference (Good for tactical messaging) CMA is a good best case metric which assumes all channels equally available and a low overhead adaptive wideband HF ALE system For each 3 KHz bin, it could have up to 60 available minutes in an hour. For each 1 MHz segment there can be a total of 60*1000000/3000 = 19980 (3 khz) Results displayed as a normalized CMA ( 0.0 1.0) Processing repeated for any bandwidth of interest ( 6-48kHz) 9

Results to Date Spectrogram of raw measured data Hønefoss in southern Norway [3] The expected frequency rise during mid-day is easy to see as are some bands of light interference. At approximately 1100 minutes and centered at 10 MHz there is a portion of higher channel usage. 10

Results to Date II An alternate way to examine the measured data is via the CMA defined above. Again, this should give a good feel for the best case channel availability. This is the same data from Hønefoss analyzed for the CMA metric for a bandwidth of 24 khz. The analysis software will generate a diagram like this for each bandwidth of interest. It should be noted that is this display the frequency and time axis are swapped. 11

Results to Date III Results of data collected by Thales in Belgium [12]. CMA obtained for both 3 khz and 24 khz channel availability. As expected as wider bandwidth channels are required, the overall channel availability diminishes due to interferers which leave less contiguous unused bandwidth. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0 0.72 0.63 0.60 0.64 0.66 0.60 0.87 0.58 0.98 0.91 0.97 0.98 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1 0.71 0.64 0.56 0.65 0.64 0.59 0.86 0.55 0.95 0.86 0.95 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2 0.69 0.62 0.54 0.66 0.63 0.61 0.87 0.62 0.94 0.86 0.95 0.99 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.00 3 0.69 0.63 0.57 0.61 0.64 0.64 0.88 0.65 0.91 0.88 0.97 0.99 0.99 0.98 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 4 0.72 0.66 0.58 0.60 0.63 0.66 0.89 0.66 0.93 0.87 0.97 0.97 0.99 0.97 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 5 0.73 0.67 0.57 0.66 0.65 0.68 0.90 0.66 0.96 0.92 0.97 0.97 0.99 0.98 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 6 0.72 0.66 0.63 0.62 0.68 0.69 0.90 0.72 0.95 0.92 0.97 0.95 0.98 0.88 1.00 0.97 1.00 0.91 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 7 0.70 0.64 0.72 0.72 0.70 0.73 0.82 0.74 0.94 0.87 0.94 0.88 0.89 0.72 0.97 0.80 0.99 0.86 0.99 0.95 0.99 0.99 1.00 0.99 0.99 0.99 1.00 1.00 8 0.68 0.63 0.73 0.77 0.66 0.68 0.73 0.71 0.87 0.74 0.84 0.77 0.79 0.64 0.91 0.75 0.95 0.94 0.96 0.96 0.98 0.99 0.99 0.97 0.91 0.94 0.98 0.98 9 0.73 0.73 0.73 0.79 0.71 0.65 0.72 0.68 0.83 0.67 0.81 0.71 0.71 0.63 0.86 0.71 0.90 0.92 0.92 0.90 0.96 0.94 0.97 0.97 0.86 0.84 0.95 0.98 10 0.77 0.76 0.75 0.81 0.75 0.65 0.74 0.69 0.81 0.73 0.80 0.70 0.71 0.63 0.88 0.68 0.90 0.92 0.92 0.88 0.94 0.94 0.96 0.96 0.87 0.83 0.96 0.99 11 0.87 0.86 0.78 0.81 0.78 0.73 0.76 0.72 0.84 0.75 0.75 0.67 0.71 0.66 0.88 0.66 0.90 0.92 0.92 0.89 0.94 0.97 0.95 0.96 0.85 0.84 0.94 0.98 12 0.87 0.78 0.80 0.87 0.79 0.72 0.76 0.68 0.83 0.68 0.73 0.65 0.73 0.65 0.86 0.69 0.88 0.91 0.90 0.87 0.91 0.95 0.93 0.96 0.84 0.82 0.94 0.95 13 0.92 0.78 0.81 0.87 0.80 0.74 0.77 0.56 0.83 0.62 0.73 0.67 0.75 0.65 0.87 0.66 0.88 0.92 0.91 0.83 0.93 0.96 0.93 0.96 0.83 0.81 0.94 0.95 14 0.80 0.74 0.76 0.87 0.77 0.67 0.74 0.44 0.82 0.56 0.69 0.63 0.73 0.60 0.87 0.70 0.89 0.93 0.92 0.82 0.93 0.93 0.93 0.96 0.81 0.73 0.90 0.99 15 0.88 0.78 0.77 0.77 0.68 0.54 0.72 0.42 0.83 0.57 0.71 0.64 0.72 0.64 0.89 0.69 0.89 0.96 0.96 0.85 0.96 0.99 0.96 0.98 0.93 0.86 0.94 0.99 16 0.82 0.78 0.70 0.65 0.51 0.46 0.68 0.34 0.85 0.63 0.71 0.66 0.75 0.61 0.93 0.79 0.93 0.96 0.98 0.92 0.99 0.99 0.98 0.99 0.99 0.97 0.99 1.00 17 0.76 0.72 0.70 0.67 0.51 0.42 0.71 0.37 0.86 0.66 0.79 0.66 0.83 0.64 0.94 0.90 0.98 0.99 1.00 0.96 1.00 1.00 1.00 1.00 0.99 0.99 1.00 1.00 18 0.73 0.64 0.67 0.69 0.58 0.50 0.76 0.40 0.93 0.74 0.87 0.80 0.94 0.78 0.98 0.93 0.99 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 19 0.74 0.51 0.64 0.67 0.57 0.46 0.70 0.42 0.94 0.74 0.90 0.91 0.96 0.86 0.97 0.98 0.98 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 20 0.73 0.53 0.64 0.70 0.63 0.54 0.80 0.51 0.97 0.88 0.98 0.98 0.97 0.96 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 21 0.69 0.53 0.67 0.74 0.69 0.63 0.85 0.66 0.98 0.93 0.99 0.99 0.98 0.99 0.99 1.00 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 22 0.73 0.52 0.66 0.73 0.67 0.59 0.84 0.64 0.99 0.92 1.00 1.00 0.98 0.99 0.99 0.99 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 23 0.70 0.55 0.62 0.70 0.65 0.62 0.85 0.59 0.98 0.89 0.98 1.00 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0.48 0.26 0.28 0.38 0.45 0.39 0.73 0.30 0.94 0.79 0.91 0.96 1.00 0.98 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1 0.48 0.27 0.24 0.35 0.42 0.41 0.73 0.33 0.90 0.68 0.87 0.98 0.98 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 1.00 1.00 2 0.43 0.25 0.22 0.37 0.40 0.39 0.75 0.38 0.89 0.70 0.88 0.96 0.99 0.98 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.98 1.00 1.00 1.00 1.00 1.00 3 0.43 0.26 0.26 0.33 0.41 0.39 0.76 0.42 0.84 0.73 0.93 0.94 0.99 0.95 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 4 0.50 0.31 0.24 0.29 0.41 0.41 0.74 0.34 0.85 0.71 0.95 0.90 0.98 0.90 0.99 1.00 1.00 0.98 1.00 1.00 1.00 1.00 1.00 1.00 0.99 0.99 0.99 1.00 5 0.49 0.36 0.24 0.34 0.40 0.45 0.75 0.44 0.90 0.82 0.94 0.92 0.99 0.93 0.98 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 0.99 1.00 6 0.48 0.33 0.35 0.34 0.43 0.44 0.78 0.50 0.88 0.81 0.94 0.89 0.95 0.71 0.99 0.92 1.00 0.89 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.99 1.00 1.00 7 0.41 0.26 0.45 0.47 0.40 0.43 0.62 0.53 0.85 0.71 0.86 0.72 0.74 0.49 0.93 0.66 0.98 0.83 0.98 0.90 0.99 0.99 1.00 0.99 0.97 0.96 0.99 1.00 8 0.40 0.23 0.43 0.49 0.33 0.38 0.46 0.38 0.67 0.50 0.58 0.53 0.52 0.37 0.77 0.58 0.86 0.87 0.88 0.89 0.96 0.98 0.98 0.95 0.83 0.81 0.94 0.98 9 0.45 0.39 0.37 0.51 0.39 0.37 0.42 0.28 0.59 0.36 0.57 0.45 0.40 0.33 0.67 0.49 0.76 0.83 0.80 0.79 0.90 0.88 0.94 0.91 0.65 0.56 0.88 0.98 10 0.45 0.45 0.37 0.54 0.46 0.36 0.44 0.33 0.54 0.44 0.51 0.43 0.42 0.33 0.72 0.47 0.79 0.83 0.85 0.74 0.87 0.88 0.93 0.88 0.67 0.55 0.86 0.98 11 0.67 0.72 0.47 0.64 0.50 0.51 0.46 0.35 0.61 0.45 0.43 0.38 0.43 0.38 0.72 0.42 0.79 0.83 0.84 0.74 0.90 0.94 0.91 0.87 0.65 0.56 0.83 0.97 12 0.72 0.69 0.50 0.70 0.58 0.48 0.48 0.29 0.62 0.37 0.41 0.39 0.46 0.36 0.69 0.45 0.78 0.81 0.80 0.73 0.82 0.91 0.88 0.89 0.63 0.51 0.85 0.93 13 0.80 0.65 0.54 0.71 0.57 0.43 0.51 0.22 0.59 0.29 0.46 0.41 0.49 0.38 0.68 0.45 0.77 0.82 0.83 0.64 0.87 0.94 0.89 0.87 0.63 0.52 0.82 0.93 14 0.52 0.50 0.43 0.69 0.47 0.38 0.44 0.16 0.57 0.31 0.41 0.34 0.45 0.32 0.65 0.54 0.78 0.86 0.82 0.65 0.84 0.90 0.87 0.88 0.55 0.37 0.75 0.99 15 0.71 0.62 0.48 0.51 0.33 0.31 0.43 0.15 0.59 0.34 0.42 0.34 0.48 0.33 0.71 0.48 0.78 0.90 0.88 0.71 0.91 0.98 0.91 0.95 0.80 0.62 0.85 0.99 16 0.63 0.53 0.32 0.38 0.18 0.27 0.40 0.13 0.63 0.36 0.42 0.39 0.53 0.37 0.79 0.61 0.85 0.91 0.94 0.81 0.97 0.99 0.96 0.98 0.97 0.88 0.96 1.00 17 0.50 0.47 0.31 0.37 0.17 0.25 0.43 0.15 0.69 0.41 0.56 0.45 0.67 0.44 0.84 0.76 0.95 0.98 0.99 0.89 1.00 1.00 0.99 1.00 0.98 0.97 0.99 1.00 18 0.49 0.38 0.30 0.42 0.33 0.32 0.55 0.21 0.85 0.54 0.66 0.62 0.86 0.57 0.95 0.80 0.99 1.00 1.00 0.97 1.00 1.00 1.00 1.00 0.98 0.99 1.00 1.00 19 0.49 0.23 0.31 0.43 0.30 0.27 0.45 0.25 0.84 0.56 0.76 0.77 0.90 0.68 0.87 0.95 0.90 0.96 1.00 0.99 1.00 1.00 1.00 1.00 0.97 1.00 1.00 1.00 20 0.47 0.22 0.31 0.45 0.40 0.35 0.66 0.26 0.93 0.73 0.93 0.95 0.94 0.92 0.95 0.96 0.95 0.97 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.99 1.00 1.00 21 0.42 0.20 0.31 0.53 0.50 0.45 0.74 0.35 0.96 0.82 0.97 0.96 0.96 0.97 0.96 0.99 0.97 0.98 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.99 1.00 1.00 22 0.48 0.18 0.29 0.47 0.47 0.40 0.71 0.39 0.98 0.82 1.00 0.99 0.98 0.98 0.95 0.97 0.95 0.96 0.98 1.00 1.00 1.00 1.00 1.00 0.99 0.99 1.00 1.00 23 0.43 0.17 0.29 0.42 0.44 0.38 0.72 0.30 0.92 0.75 0.95 1.00 0.99 0.97 0.99 0.99 0.99 0.99 1.00 1.00 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 12

Results to Date IV Results of data collected by the working group is provided by Babcock [13] Data was collected at their Forest Moor site in Yorkshire, UK using a conical wideband RX antenna. This data again shows the expected time of day variations of channel utilization including the lack of lower frequency propagation during the day, and the corresponding increased use of these frequencies during the evening hours as well as wide availability of the higher frequencies. Highlights the need of spatially diverse measurement locations in order to capture channel occupancy otherwise missed due to the realities of HF propagation. One interesting segment shows some channel utilization, during the day in the 26-28 MHz band. This could possibly be some Citizens band or Land Mobile radio utilization. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 0 0.61 0.36 0.34 0.49 0.34 0.37 0.58 0.27 0.76 0.64 0.83 0.91 0.96 0.92 0.95 0.99 0.99 1.00 0.98 0.99 0.98 0.99 0.99 1.00 0.98 0.98 0.99 1.00 1 0.59 0.40 0.29 0.48 0.34 0.41 0.56 0.28 0.75 0.58 0.85 0.88 0.96 0.93 0.96 0.98 0.99 1.00 0.98 0.99 0.99 0.99 0.98 1.00 0.98 0.99 0.99 1.00 2 0.57 0.41 0.32 0.51 0.37 0.43 0.56 0.35 0.80 0.52 0.82 0.89 0.96 0.88 0.96 0.97 0.99 1.00 0.98 0.99 0.98 0.99 0.98 1.00 0.98 0.99 0.99 1.00 3 0.58 0.44 0.37 0.48 0.41 0.42 0.56 0.46 0.85 0.64 0.86 0.91 0.96 0.90 0.96 0.99 0.99 1.00 0.98 0.99 0.98 0.99 0.99 1.00 0.98 0.99 0.99 1.00 4 0.56 0.42 0.34 0.49 0.39 0.44 0.57 0.43 0.80 0.62 0.94 0.94 0.96 0.94 0.96 0.99 0.99 1.00 0.98 0.98 0.98 0.99 0.98 1.00 0.98 0.99 0.99 1.00 5 0.58 0.48 0.39 0.44 0.38 0.43 0.51 0.39 0.72 0.68 0.88 0.87 0.95 0.87 0.96 0.98 0.99 0.99 0.98 0.99 0.99 0.99 0.98 1.00 0.98 0.99 0.99 1.00 6 0.61 0.53 0.41 0.48 0.38 0.42 0.56 0.54 0.74 0.67 0.83 0.79 0.89 0.69 0.95 0.89 0.99 0.99 0.97 0.99 0.99 0.99 0.98 1.00 0.98 0.99 0.99 1.00 7 0.58 0.54 0.43 0.55 0.39 0.44 0.60 0.59 0.77 0.64 0.81 0.66 0.73 0.56 0.86 0.68 0.97 0.97 0.95 0.91 0.98 0.99 0.99 1.00 0.97 0.96 0.99 1.00 8 0.60 0.57 0.45 0.62 0.35 0.50 0.59 0.53 0.69 0.49 0.61 0.60 0.54 0.54 0.80 0.63 0.92 0.97 0.94 0.88 0.95 0.98 0.96 0.98 0.92 0.80 0.95 1.00 9 0.61 0.69 0.53 0.64 0.32 0.55 0.60 0.48 0.69 0.47 0.60 0.57 0.48 0.53 0.77 0.65 0.86 0.92 0.87 0.84 0.92 0.97 0.95 0.91 0.68 0.55 0.87 0.99 10 0.65 0.82 0.58 0.70 0.34 0.58 0.62 0.50 0.66 0.48 0.60 0.56 0.54 0.51 0.76 0.57 0.84 0.92 0.92 0.80 0.91 0.96 0.91 0.91 0.66 0.39 0.82 0.98 11 0.79 0.87 0.59 0.81 0.44 0.63 0.63 0.49 0.64 0.50 0.55 0.55 0.58 0.52 0.75 0.54 0.86 0.92 0.92 0.79 0.89 0.96 0.85 0.88 0.55 0.27 0.75 0.97 12 0.78 0.90 0.65 0.82 0.48 0.66 0.65 0.47 0.65 0.47 0.58 0.53 0.57 0.52 0.69 0.57 0.85 0.94 0.91 0.77 0.92 0.97 0.88 0.91 0.60 0.31 0.77 0.98 13 0.76 0.94 0.87 0.85 0.51 0.62 0.71 0.38 0.72 0.49 0.61 0.53 0.56 0.47 0.67 0.56 0.78 0.91 0.87 0.66 0.89 0.96 0.90 0.91 0.57 0.25 0.73 0.94 14 0.79 0.90 0.80 0.78 0.39 0.51 0.66 0.29 0.68 0.37 0.53 0.48 0.51 0.39 0.69 0.60 0.80 0.91 0.86 0.65 0.85 0.95 0.89 0.91 0.52 0.22 0.66 0.94 15 0.90 0.95 0.91 0.86 0.60 0.58 0.77 0.42 0.73 0.45 0.61 0.60 0.60 0.54 0.75 0.60 0.79 0.91 0.90 0.79 0.89 0.97 0.91 0.92 0.65 0.29 0.73 0.96 16 0.86 0.87 0.70 0.70 0.27 0.35 0.60 0.21 0.64 0.29 0.56 0.50 0.52 0.45 0.72 0.65 0.81 0.91 0.87 0.73 0.90 0.97 0.92 0.92 0.61 0.29 0.75 0.97 17 0.67 0.54 0.41 0.51 0.15 0.27 0.56 0.25 0.66 0.36 0.51 0.50 0.43 0.40 0.75 0.69 0.84 0.92 0.89 0.81 0.93 0.97 0.93 0.94 0.72 0.50 0.86 0.97 18 0.58 0.35 0.45 0.49 0.15 0.30 0.57 0.26 0.71 0.39 0.53 0.54 0.49 0.52 0.85 0.71 0.88 0.97 0.93 0.86 0.97 0.98 0.96 1.00 0.94 0.83 0.97 0.99 19 0.59 0.37 0.47 0.49 0.16 0.27 0.52 0.21 0.69 0.34 0.59 0.58 0.58 0.63 0.85 0.84 0.93 0.99 0.94 0.93 0.97 0.98 0.97 1.00 0.95 0.85 0.98 0.99 20 0.59 0.39 0.46 0.51 0.21 0.31 0.58 0.24 0.71 0.41 0.67 0.66 0.65 0.66 0.89 0.86 0.94 0.98 0.94 0.96 0.98 0.98 0.98 1.00 0.96 0.92 0.99 0.99 21 0.57 0.36 0.38 0.50 0.23 0.32 0.51 0.27 0.74 0.50 0.71 0.75 0.70 0.75 0.90 0.91 0.96 0.99 0.96 0.98 0.99 0.99 0.98 1.00 0.98 0.97 0.99 1.00 22 0.53 0.32 0.37 0.53 0.29 0.37 0.61 0.29 0.73 0.54 0.72 0.83 0.84 0.87 0.94 0.97 0.99 0.99 0.98 0.99 0.99 0.99 0.98 1.00 0.98 0.97 0.99 1.00 23 0.61 0.37 0.38 0.51 0.31 0.39 0.62 0.29 0.74 0.48 0.84 0.89 0.94 0.89 0.96 0.98 0.99 1.00 0.98 0.99 0.98 0.99 0.98 1.00 0.98 0.98 0.99 1.00 13

Conclusions and Future Work HFIA meets every six months Tools and software in place Planned Data Collection: Rockwell plans a series of measurements in Iowa, Washington (Seattle area), Las Cruces, Tampa, Brazil, Australia (two sites), Singapore, and India. Harris plans to continue measurements in western New York / UK. Norway is planning a series of measurements in throughout Norway. Results expected from Europe as well by Thales Investigation Focus Effects of observation times and revisit rates in the measurement system Antenna deployment issues Comparison of different antenna systems for measurement Correlation of results with assigned HF bands Use of results for performance prediction on specific links 14

Acknowledgements The Authors would like to thank all the members of the HFIA Wideband Channel Availability working group for their contributions to date of this truly international partnership. In addition to the cited work and results contained in this paper, further data collection, analysis, and presentations from: Thales - France, FFI Norway, Rohde & Schwarz - Germany, French Ministry of Defense (DGA), Fraunhofer - Germany, Babcock UK, Rockwell Collins Harris Corporation USA can be found on the HFIA website; www.hfindustry.com. 15