INSTRUCTION MANUAL Mi455

Similar documents
HI FREE & TOTAL SULPHUR DIOXIDE MINITITRATOR for wine analysis

INSTRUCTION MANUAL Mi456

INSTRUCTION MANUAL Mi453 Reducing Sugars

INSTRUCTION MANUAL Milwaukee Wine Lab Photometer Mi454 Tartaric Acid

HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

HI Titratable Total Acidity Mini Titrator for Wine Analysis

Acidity and ph Analysis

Measuring Fluoride in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Find out all you need to know about measuring SO 2. in wine making

BREW EXPRESS OPERATION GUIDE MODEL BE112

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

AUTOMATIC BURR COFFEE GRINDER

BREW EXPRESS OPERATION GUIDE. model no. BE-112

THE COBURN COMPANY, INC. PO Box 147 Whitewater, WI U.S.A. Phone: Fax:

TEA CATER USER MANUAL. UM_EN Part No.:

CMC DUO. Standard version. Table of contens

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

Micro Casa Semiautomatica

IMPORTANT SAFEGUARDS. 3. To protect against fire, electric shock and injury to persons do not immerse cord, plug or unit in water or other liquid.

WE CAN HELP. Smart Coffee Maker User Manual. Can t connect? Need help? DO NOT RETURN THIS PRODUCT TO THE STORE

HI COLOR & PHENOLS ISM for wine analysis

1.5 L Slow Cooker 7644 Instructions for Use

Please read all directions before using the product and retain this guide for reference. This product is intended for household use only.

IMPORTANT INSTRUCTIONS MODE D EMPLOI IMPORTANT INSTRUCIONES IMPORTANTES ISTRUZIONI IMPORTANTI

OPERATING INSTRUCTIONS FOR YOUR SAFETY CAREFULLY READ THE OPERATING INSTRUCTIONS. FOR HOUSEHOLD USE ONLY

Alcolyzer Plus Spirits

Vinmetrica SC-50 MLF Analyzer User Manual

CAIMANO SPECIAL450 BARISTA

Pellet Pro 12 & 18 Lengths Large 35lb Hopper Assembly Operation Manual

Programmable Conical Burr Mill CBM-18

Vinmetrica SC-100A User Manual

左边 :SAFTY NOTES 右边 : Please follow the safety precautions to avoid any harm to yourself and cause any damages Never Always Warning Attention

phd Pitcher UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

Scishare Coffee Machine

COFFEE MAKER INSTRUCTION MANUAL CM4682-V

User Manual. Thermo Pump System Coffee Brewers User Manual. Models: 177C10, 177C15 04/2018. Please read and keep these instructions. Indoor use only.

Vinmetrica SC-100A User Manual

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

What's in the box 2 ENGLISH

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

Booklet_TCG-357_ENG.qxd 9/8/08 11:19 AM Page 1 COFFEE/SPICE GRINDER. Instruction Booklet. Model: TCG-357

Installation & Parts Manual 2" & 3" High Capacity Strainers For Class 1, Petroleum Applications

TOASTER OVEN USER MANUAL MODEL: PKMFT039

Installation and User Instructions Flushing System Kit

Downloaded from Quick Start Guide D512. Smart Decanter

MODELS 1315 & 1315-S La Pavoni CLUB COMBO

AS450, AS600, G1, SG630

User Guide TEA CATER. Your Dealer. U / EN Rev

Coffee Grinder Instruction Manual

A N F I M Srl. Caimano: Timer / Automatico / Manuale Super Caimano: Timer / Automatico Caimano SPecial 450: Timer / Automatico

12 CUP COFFEE MAKER User Guide

Welcome to the perfect pour!

ORIGINAL LINE A USER MANUAL

Manual Spark Ignition (MSI) Kit For Use only with Thermocouple Manual Safety (TMSI) UL Approved Fire Pit Pans with Burning Spur

User manual COFFEE QUEEN. Tower 10 litre for wall mounting. Your retail dealer. U / GB Rev

QUICK START GUIDE F10 - F20

USER MANUAL TECHNICAL DATA

COFFEE GRINDER. Owner s Manual

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

coffee smoothie gin and strawberry cocktail rum and mango cocktail chocolate orange smoothie lemon zinger fruit cocktail surprise

TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

2016 Gourmia The Steelstone Group Brooklyn, NY

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

Coffeemaker User's manual

E N T E R P R I S E S

Operating the Rancilio Silvia after PID kit modification Version 1.1

User Manual. Stainless Steel Coffee Urns. Models: 177CU55ETL, 177CU110ETL 10/2016. Please read and keep these instructions. Indoor use only.

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

USER MANUAL. Fully-automatic Coffee Machine

A N F I M Srl. Caimano On Demand. Super Caimano COFFEE GRINDER C O D Y S C O D Y - II. Model

instructions COFFEE GRINDER KG 79/89

CHOCOLINO CAFÉLINO USER MANUAL UM_EN. Part No.: _01

INSTALLATION & OPERATING GUIDE

QUALITY MILK FROTHER INSTRUCTION MANUAL MODEL NO. MMF005

LB 951. Istruzioni per l uso Instructions Mode d emploi Bedienungsanleitung Instrucciones de empleo Instruções de utilização Gebruiksaanwijzing

User Manual. Stainless Steel Coffee Urn. Models: 177CU30 11/2018. Please read and keep these instructions. Indoor use only.

Built in Electric Fan Oven

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

Important Safety Information

User Manual. Stainless Steel Coffee Urns. Models: 177CU30, 177CU55, 177CU110 04/2018. Please read and keep these instructions. Indoor use only.

Wi-Fi Coffee Maker. Model# GCMW-4750 USER MANUAL

Grind by Weight Accessory. Operations Manual. ESATTO TM shown with Preciso TM Grinder

18-Bottle Dual Zone Slimline Edition Touchscreen Refrigerator

Water kettle with adjustable temperature User guide

Electric Two-Speed Drink Mixer

STAINLESS STEEL GAS BARBECUE MODEL NO: SSBBQ4 USER GUIDE PART NO: /11

The Scoop 2-Way Brewer

MANUAL FOR USE AND MAINTENANCE. Vivaldi LSC 008 REV. 01

Micro Casa a Leva Training Manual

K35 Use & Care Guide. Get the most from your new Keurig coffee maker

Armonia Smart. Quick Start Guide MACHINE DESCRIPTION STARTING UP

DISCONTINUED VERSION The information in this manual is no longer current. Espresso/Cappuccino OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION

DE MANUAL BENUTZERHANDBUCH SM7683, SM7680 SM6080/SM6081/SM7080/SM7081 USER MANUAL BENUTZERHANDBUCH BENUTZERHANDBUCH

Let s get brewing. K Quick Start Guide

3-in-1 K-Cup Coffee Maker

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

REVERSIBLE DOOR 1. LAMP SWITCH 2. CABINET 3. LEVELLING LEGS 4. WINE RACK 5. GLASS DOOR 6. CHROME SHELVES 7. INTERIOR LAMP 8.

Quick Start Guide Read this booklet thoroughly and save these instructions.

Transcription:

www.milwaukeetesters.com INSTRUCTION MANUAL Milwaukee Wine ine Lab Minititrator Mi455 Free ree & Total Sulphur Dioxide www.milwaukeeinst.com 1

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis TABLE OF CONTENTS FUNCTIONAL DESCRIPTION... 3 GENERAL DESCRIPTION... 4 PRINCIPLE OF OPERATION... 6 SPECIFICATIONS... 7 STARTUP... 8 GUIDE TO DISPLAY CODES... 9 GENERAL TIPS FOR AN ACCURATE MEASUREMENT... 11 PUMP CALIBRATION PROCEDURE... 11 FREE SO 2 MEASUREMENT PROCEDURE... 13 TOTAL SO 2 MEASUREMENT PROCEDURE... 14 PUMP TUBE REPLACEMENT... 15 FUSE REPLACEMENT... 16 ELECTRODE CONDITIONING AND MAINTENANCE... 16 ACCESSORIES... 18 2

www.milwaukeeinst.com FUNCTIONAL DESCRIPTION DISPLAY A. HOURGLASS ICON B. BATTERY STATUS ICON C. ERROR MESSAGE D. MEASURE STATUS E. CALIBRATION MODE INDICATOR F. MAIN DISPLAY G. MEASUREMENT UNIT H. TIMER MODE INDICATOR I. SECONDARY DISPLAY FRONT PANEL A. TITRANT BOTTLE B. LIQUID CRYSTAL DISPLAY (LCD) C. KEYPAD D. ELECTRODE HOLDER REAR PANEL E. ORP ELECTRODE F. PERISTALTIC PUMP TUBE G. BEAKER H. PERISTALTIC PUMP I. BNC ELECTRODE CONNECTOR J. FUSE K. POWER CABLE CONNECTOR L. POWER SWITCH 3

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis KEYPAD A. PUMP - to start/stop the pump B. CAL - to enter pump calibration mode C. STIR - to start/stop the stirrer while in measurement or purging mode D. START STOP - to start/stop titration or pump calibration GENERAL DESCRIPTION The Mi455 is a low-cost, easy to use, microprocessor-based automatic titrator. It has a simple and reliable peristaltic pump that ensure high dosing repeatability. By performing pump calibration with the provided Milwaukee standards, the instrument accuracy is assured. The instrument comes with a pre-programmed analysis method designed for Free and Total Sulphur Dioxide measurements on wine samples. The instrument has a powerful and effective built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion. This algorithm automatizes the analysis, makes all the necessary calculations and assures a simple and effective interface for the user. By simply pressing the START STOP button, the instrument will automatically make the titration up to the equivalence point. The result is immediately displayed in convenient units, then the instrument is ready for another titration. SIGNIFICANCE OF USE An important reason for adding SO 2 is to avoid oxidation. When there is oxygen around, SO 2 itself becomes oxidized before phenol compounds in the wine, and so acts as an oxygen scavenger. Also SO 2 suppresses the activity of enzymes that cause browning and other problems. What is really protecting your wine is molecular SO 2. When you add SO 2, depending of circumstances, some of it immediately becomes bound. The relationship between the amount of added SO 2 and the amount of SO 2 remaining free is complex. It is clear, however, that it is largely governed by the total SO 2 content of the wine. The rate of binding decreases as the free SO 2 concentration increases. The exact relationship between free and bound (total - free) SO 2 will vary from wine to wine. Below 30-60 ppm, 33% to 50% of SO 2 addition becomes bounded. What remains is called free and it is divided in two parts. The larger, and relatively ineffective free part is 4

www.milwaukeeinst.com bisulphite (HSO 3- ). The smaller part of the free is the active molecular SO 2. The amount of molecular SO 2 in your wine depends both on the level of free SO 2 present as well as ph. For instance, at ph 3.2, the amount of free SO 2 for 0.8 ppm molecular SO 2 is 22 ppm. At ph 3.5, you will need 43 ppm free - essentially double. Free SO 2 concentration (ppm) for 0.8 ppm molecular SO 2 : ph 3. 0 3. 1 3. 2 3. 3 3. 4 3. 5 3. 6 3. 7 3. 8 3. 9 Free SO 14 18 22 28 35 44 55 69 87 109 2 In most situations, 0.8 ppm molecular SO 2 during bulk storage and at bottling will provide you with adequate protection from oxidation and bacterial action. This includes prevention of malolactic bacteria as well. It is important to remember that the amount of free SO 2 in the wine depends on three things: how much is added, how much was present before the addition and how much of your addition promptly becomes bound. The level at which molecular SO 2 can be detected by the human senses is about 2.0 ppm. This is also the level which is needed for maximum protection of your wine. This is particularly true in the case of sweet, and most notably, botrytised wines. The Milwaukee Mi455 offers the possibility to test free or total SO 2 in all the wines including the red ones, that are difficult to test with manual methods because the color changes are hardly seen. This meter is supplied with: Reagents set for 20 titrations Two 50 ml beakers Two 20 ml beakers Tubes set with cap ORP probe Stir bar Power cable One 230 ml bottle of Refill Solution One 1 ml syringe Instruction manual Warranty code Note: Save all packing material until you are sure that the instrument works correctly. Any defective item must be returned in its original packing. 5

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis PRINCIPLE OF OPERATION Determination of sulphur dioxide in wine samples is made by titration of the sulphur dioxide present in wine with iodate. In this procedure an excess of iodine is added to the wine sample and it is titrated with iodate. For precise results it is very important to know the exact sample volume, titrant volume and concentration. The peristaltic pump has a good repeatability but the dosing volume depends on many factors as the diameter of the tube or the tube stretching. To compensate for all this errors, the pump need to be calibrated. The calibration of the pump is also needed in order to have high precision of the titrations. The calibration procedure is in fact the analysis of a known solution. By doing this, the instrument makes a differential analysis between the standard and the wine sample. The pump volumetric debit and the real concentration of the titrant is compensated. Only the sample volume has to be precisely known. 6

www.milwaukeeinst.com SPECIFICATIONS Range 0 to 400 ppm SO 2 Resolution 1 ppm Accuracy 5% of reading Method Ripper titrimetric method Principle Equivalence point redox titration Sample volume 50 ml ORP Electrode MA924B/1 (included) Pump debit 0.5 ml/min Stirring speed 1500 rpm Environment 0 to 50 C (32 to 122 F) ; max 95% RH non-condensing Power supply 220V/50Hz; 10VA Dimensions 208 x 214 x 163 mm (8.2 x 8.4 x 6.4") (with beaker) Weight 2200 g (77,6 oz.). Required Reagents Code Description Quantity/test Mi555-001 Standard (for Free & Total SO 2 ) 50 ml Mi555-002 Titrant (for Free & Total SO 2 ) Mi555-003 Alkaline Reagent (for Total SO 2 ) 5 ml Mi555-004 Acid Reagent (for Total SO 2 ) 5 ml Mi555-005 Acid Reagent (for Free SO 2 ) 5 ml Mi555-006 Stabilizer (for Free & Total SO 2 ) 1 packet This instrument is in compliance with CE Directives. 7

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis STARTUP Place the instrument on a flat table. Do not place the instrument on direct sun light. Connect the titrator to mains socket with ground connection and the correct voltage and frequency. See the label on the instrument rear for this. Place the peristaltic pump tube on the pump. See the Pump Tube Replacement section for the procedure. Remove the reagent bottle cap and place the bottle cap of the tubes set. Place the reagent bottle in the appropriate place on the titrator top. Connect the tubes with the peristaltic pump (inlet tube is connected with the reagent bottle, outlet tube is connected with the dosing tip). Turn the instrument ON using the power switch from the rear panel of the instrument and wait until it displays dashes. 8

www.milwaukeeinst.com PROBE GUIDE FUNCTIONAL TO DISPLAY DESCRIPTION CODES This screen appears for a few seconds each time the instrument is turned ON. Main screen display. Main screen display with stirrer active. Purging mode message. PUMP CALIBRATION MESSAGES This screen appears each time the meter enters pump calibration mode. The meter is ready to start pump calibration by pressing the START STOP button. This screen appears while pump calibration is in progress. Pressing CAL or START STOP button, the minititrator returns to the main screen. This screen appears for a few seconds before returning to the main screen, when pump calibration is done. 9

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis This error message appears when the sample concentration exceeds 400 ppm. The used standard solution is wrong. This error message appears when the input readings (mv) exceed the input limits (0 1000mV). TITRATION MESSAGES This screen appears each time a titration is running. When the START STOP button is pressed the minititrator returns to the main screen. The titration result, expressed as concentration of sulphur dioxide in ppm (mg/l), is displayed at the end of the titration process. Press the START STOP button to return to the main screen. This error message appears when the input reading exceeds the input limits (0 1000mV). This screen appears when the sample concentration exceeds 400 ppm. 10

www.milwaukeeinst.com GENERAL TIPS FOR AN ACCURATE MEASUREMENT The instructions listed below should be carefully followed during testing to ensure best accuracy. Purge the peristaltic pump to have fresh titrant when starting a new analysis or calibration. Calibrate the peristaltic pump before performing an analysis. Analyze the wine immediately after the sample is obtained. PUMP CALIBRATION PROCEDURE Warning: The calibration of the pump must be performed each time the pump tube, the reagent bottle or the ph electrode is changed. It is recommended to perform the pump calibration before each set of measurements. Using a clean pipette, fill the 50 ml beaker up to the 50 ml mark with Mi555-001 Standard. Note: Failure to use clean pipettes will result in erroneus readings. Place the stir bar in the beaker and put the beaker in the minititrator top. Fill the 20 ml beaker up to the 5 ml mark with the Mi555-005 Acid Reagent and add the content to the 50 ml beaker. Place the beaker into the beaker holder. Place the probe holder on the top of the beaker and secure by turning clockwise. 11

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis Open refill cap on the ORP electrode and immerse the electrode approximately 2 cm (0.8 ) into the sample to be tested. Do not touch stir bar with the tip of the electrode. Ensure there is titrant in the dosing tip. If not, hold the dosing tip over an empty container and press PUMP for a few seconds until the titrant is in the dosing tip. Add the contents of one powder packet of Mi555-006 Stabilizer into the beaker. Press CAL button. The meter enters in pump calibration mode. Press START STOP in order to start the system calibration. At the end of the calibration, DONE appears for a few seconds and the meter returns to the measurement mode. 12

www.milwaukeeinst.com FREE SO 2 MEASUREMENT PROCEDURE Using a clean pipette, fill the 50 ml beaker up to 50 ml mark with the wine sample. Note: It is important to be accurate in your measurements of Wine sample. Pipettes are recommended. Place the stir bar in the beaker and put the beaker in the minititrator top. Fill the 20 ml beaker up to the 5 ml mark with the Mi555-005 Acid Reagent and add the content to the 50 ml beaker. Place the probe holder on the top of the beaker and secure by turning clockwise. Open refill cap on the ORP electrode and immerse the electrode approximately 2 cm (0.8 ) into the sample to be tested. Do not touch stir bar with the tip of the electrode. Insert dosing tip into holder. Ensure there is titrant in the dosing tip. If not, hold the dosing tip over an empty container and press PUMP for a few seconds until the titrant is in the dosing tip. The tip should be below the pump to ensure gravity flow. Note: Be aware of any air bubbles in the tube it could effect the results. Add the contents of one powder packet of Mi555-006 Stabilizer into the beaker. 13

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis Press START STOP in order to start titration. The display will show ---- during titration, along with stirrer and pump tags blinking on the LCD. At the end of the titration, the Sulphur Dioxide concentration is displayed in mg/l (ppm). TOTAL SO 2 MEASUREMENT PROCEDURE Fill the 50 ml beaker up to 50 ml mark with the wine sample. Note: It is important to be accurate in your measurement of wine sample. Pipettes are recommended. Place the stir bar in the beaker and put the beaker in the minititrator top. Fill the 20 ml beaker up to the 5 ml mark with the Mi555-003 Alkaline Reagent and add the content to the 50 ml beaker. Swirl the beaker and wait for 15 minutes. Using a clean pipette, fill the 20 ml beaker up to the 5 ml mark with the Mi555-004 Acid Reagent and add the content to the 50 ml beaker. Open refill cap on the ORP electrode and immerse the electrode approximately 2 cm (0.8 ) into the sample to be tested. Do not touch stir bar with the tip of the electrode. 14

www.milwaukeeinst.com Insert dosing tip into holder. Ensure there is titrant in the dosing tip. If not, hold the dosing tip over an empty container and press PUMP for a few seconds until the titrant is in the dosing tip. The tip should be below the pump to ensure gravity flow and minimize the chance of air bubbles in the tube. Add the content of one powder packet of Mi555-006 Stabilizer into the beaker. Press START STOP button to start titration. The display will show ---- during titration, along with stirrer and pump tags blinking on the LCD. At the end of the titration, the Sulphur Dioxide concentration is displayed in mg/l (ppm). PUMP TUBE REPLACEMENT To remove the tube of the peristaltic pump follow next steps: Detach the old tube system from the reagent bottle. Grasp one fixing ring of the peristaltic pump tube. Pull the tube until it s taken out from its location. Remove the other side of the tube. To mount the new peristaltic pump tube follow next steps: Position one peristaltic pump fixing ring on its location. Stretch the tube over the peristaltic pump cylinders. Fix the second pump fixing ring on its location. Attach the tube to the reagent bottle. Note:Purge the peristaltic pump until drops of reagent appears on the dosing tip by pressing the PUMP button. 15

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis FUSE REPLACEMENT To change the fuse follow next steps: Disconnect the power cord from the rear panel of the instrument. Pull out the fuse holder located near the power cord connector. Replace the fuse with a similar one. Push the fuse holder with the fuse in the appropriate place. ELECTRODE CONDITIONING & MAITENANCE PREPARATION PROCEDURE Remove the protective cap of the ORP electrode (MA924B/1). DO NOT BE ALARMED IF SALT DEPOSITS ARE PRESENT. This is normal with electrodes. They will disappear when rinsed with water. During transport, tiny bubbles of air may form inside the glass bulb affecting proper functioning of the electrode. These bubbles can be removed by shaking down the electrode as you would do with a glass thermometer. If the bulb and/or junction is dry, soak the electrode in MA9015 Storage Solution for at least one hour. If the filling solution (electrolyte) is more 16

www.milwaukeeinst.com than 2½ cm (1 ) below the fill hole, add MA9011 3.5M KCl Electrolyte Solution. For faster response, unscrew the fill hole screw during measurements. STORAGE PROCEDURE To minimize clogging and assure a quick response time, the glass bulb and the junction of the electrode should be kept moist and not allowed to dry out. Replace the solution in the protective cap with a few drops of MA9015 Storage Solution or, in its absence, Filling Solution (MA9011). Follow the Preparation Procedure before taking measurements. Note: NEVER STORE THE ELECTRODE IN DISTILLED OR DEIONIZED WATER. PERIODIC MAINTENANCE Inspect the electrode and the cable. The cable used for connection to the instrument must be intact and there must be no points of broken insulation on the cable or cracks on the electrode stem or bulb. Connectors must be perfectly clean and dry. If any scratches or cracks are present, replace the electrode. Rinse off any salt deposits with water. Probe Maintenance Refill the reference chamber with fresh electrolyte (MA9011). Allow the electrode to stand upright for 1 hour. Follow the Storage Procedure above. CLEANING PROCEDURE Wine deposits Soak in Milwaukee MA9016 cleaning solution for 1 hour Wine stains Soak in Milwaukee MA9016 cleaning solution for 1 hour IMPORTANT: After performing any of the cleaning procedures, rinse the electrode thoroughly with distilled water, refill the reference chamber with fresh electrolyte and soak the electrode in MA9015 Storage Solution for at least 1 hour before taking measurements. 17

Instruction Manual Mi455 FREE & TOTAL SULPHUR DIOXIDE Minititrator for wine analysis ACCESSORIES REAGENT SETS MA9011 MA9015 MA9016 Mi555-001 Mi555-002 Mi555-003 Mi555-004 Mi555-005 Mi555-006 Electrode filling solution (230 ml) Electrode storage solution (220 ml) Cleaning solution (220 ml) Calibration standard (500 ml) Titrant solution (100 ml) Alkaline reagent (100 ml) Acid reagent for Total SO 2 determination (100 ml) Acid reagent for Free SO 2 determination (100 ml) Stabilizer reagent (40 pcs.) OTHER ACCESSORIES MA924B/1 ORP probe with 1 m cable Mi0009 Stir bar (5 pcs.) Mi0010 Titrator tube (2pcs.) Mi0020 Beaker 50 ml (4 pcs.) Mi0021 Beaker 20 ml (4 pcs.) Recommendations for Users Before using this product, make sure that it is entirely suitable for your specific application and for the environment in which it is used. Operation of this instrument may cause unacceptable interferences to other electronic equipments, this requiring the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instrument EMC performance. To avoid damages or burns, do not put the instrument in microwave ovens. For yours and the instrument safety do not use or store the instrument in hazardous environments. 18

www.milwaukeeinst.com For your Safety don t use or store the instrument in hazardous environments. To avoid damages or burns, do not perform any measurement in microwave ovens. WARRANTY This instrument is warranted against defects in materials and manufacturing for a period of 2 years from the date of purchase. Electrodes are warranted for 6 months. If during this period the repair or replacement of parts is required, where the damage is not due to negligence or erroneous operation by the user, please return the intrument, electrode and probe to either distributor or our office and the repair will be effected free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered by the warranty. Milwaukee/Martini instruments reserves the right to make improvements in design, construction and appearance of its products without advance notice. 19

THANK YOU FOR CHOOSING Sales and Technical Service Contacts: Milwaukee Electronics Kft. Alsókikötő sor 11. 6726, Szeged, Hungary Tel: +36-62-428-050 Fax: +36-62-428-051 e-mail: sales@milwaukeeinst.com Milwaukee Instruments, Inc. 2950 Business Park Drive Rocky Mount, NC 27804 USA Tel: +1 252 443 3630 Fax: +1 252 443 1937 e-mail: sales@milwaukeetesters.com www.milwaukeeinst.com MANMI455 12/07