Medfusion 3500 V6. Syringe Infusion Pump. Quick Reference Card

Similar documents

TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

SERVICE MANUAL ESPRESSO COFFEE BREWER UNITS

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

Programming Guide For EXTRACTOR Coffee Brewers (CBS 2000e Series)

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

Given a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for retail turnover without error.

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

Quick Reference Guide

OPTIMA PLUS-SOFT PLUS

Standard Operating Procedure for the preparation and intravenous infusion of glucose stable isotopes

Armonia Smart. Quick Start Guide MACHINE DESCRIPTION STARTING UP

QUICK START GUIDE F10 - F20

AUTOMATIC BEAN TO CUP COFFEE MACHINE

G F I M J K L B C D E S O T H Q P U N R D 4

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

SCIg60 Infusion System. The Power of CREATIVE THINKING AS _2.0

Conv. Pre Heat. Speed. bake. clean. Conv. Bake time. Clean. convert. Maxx clean. Conv. Broil. roast. Oven

TRUSTED RELIABLE QUALITY

CMC DUO. Standard version. Table of contens

Improving Life Through Innovative Pharmacy Solutions

Important Safety Information... 1 The Xpress System The Xpress System Components... 3 Using the Espresso System... 4

AUTOMATIC BEAN TO CUP COFFEE MACHINE

Please read all directions before using the product and retain this guide for reference. This product is intended for household use only.

Automatic Coffee Machine Instruction Manual

What's in the box 2 ENGLISH

AUTOMATIC BEAN TO CUP COFFEE MACHINE

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

Instant, Freshbrew & Espresso (B2C) Machines. Technical Manual. Including Spare Parts Information. Part No. PR Issue B 02/05

Wega Mininova 2003 Installation Instructions

EN Operating Instructions 21

Operating and Installation Instructions

INSTRUCTION MANUAL FOR BUILT-IN OVENS

Scanomat TopBrewer Daily Cleaning

Important Prescribing Information. Risk That Some Auto-Injectors May Not Easily Slide Out of the Carrier Tube

Melitta c35. The fast and precise fully automatic coffee machine for fresh milk coffee specialities. Melitta SystemService

A patient guide for administration of subcutaneous immunoglobulin replacement therapy using a pump

BEAN TO CUP ESPRESSO AND CAPPUCCINO MACHINE. Instruction for use ECAM26.455

MODELS 1315 & 1315-S La Pavoni CLUB COMBO

Oven. Self-Cleaning cycle. Oven. Clock. light. Start time. Bake time

Operating and Installation Instructions

Quick Start Guide Read this booklet thoroughly and save these instructions.

the Oracle Sage by Heston Blumenthal Customer Service Centre Phone:

VIN AU VERRE 8.0. For an efficient & well managed wine by the glass service! Solutions for displaying and serving wine

MTN Products. AquaCafé r (Touch Capsules) Installation & Operations Manual

Mild or Bold Hot or Cold. Newco s LCD Series offer you coffee or tea on demand just the way you want it.

fig. 1.1 fig. 1 fig. 1.2 fig. 1.3 fig. 2 6c 6d 7c 7b 8a 8b 10b 10b 10c 10a

Infusion Series. Platinum Edition. Models. The New Standard in Coffee and Tea Batch Brewing. bunn.com/infusion-series/platinum

Contents. Electrical requirements (UK only) Preparing and attaching the hot chocolate carafe (D)... 14

Chicken Rotisserie. Model LM-8A LM-12A LM-8M LM-12M Instruction Manual

A N F I M Srl. Caimano On Demand. Super Caimano COFFEE GRINDER C O D Y S C O D Y - II. Model

Operating and Installation Instructions

Micro Casa Semiautomatica

De Longhi Appliances via Seitz, Treviso Italia

Convection. Clock Used to set the time of day. Even-Cook Convection Ovens P R. Speed clean R B B PM CONV PRE- BAKE

Equipment Yield Chart

IKAWA App V1 For USE WITH IKAWA COFFEE ROASTER. IKAWA Ltd. Unit 2 at 5 Durham Yard Bethnal Green London E2 6QF United Kingdom

Clean grill Daily GR 1 D1

Espresso Machine. Made In Italy By. Owner s Manual

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

EXPOBAR OFFICE MACHINES

the Infuser Instruction Booklet BES840

Espresso Machine. Made In Italy By

Analyzing & Troubleshooting Plunger Lifted Wells

Hotpoint H/A - Ariston automatic, built-in coffee machine MCX 103 X - MCK 103 X/HA

Programmable Conical Burr Mill CBM-18

Munis Self Service. Employee Self Service User Guide Version For more information, visit

TEA CATER USER MANUAL. UM_EN Part No.:

WE GRANTED YOUR FIRST WISH: THE BEST QUALITY IN A TOUCH

Operating the Rancilio Silvia after PID kit modification Version 1.1

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

CONTENTS. MAKING HOT CHOCOLATE Preparing and attaching the hot chocolate carafe (D) IMPORTANT SAFEGUARDS...8 SAVE THESE INSTRUCTIONS...

For Beer with Character

Scishare Coffee Machine

User Guide CQUBE M Espresso

Operation and Service Manual

ZPM Mixer. Continuous mixing system

coffee wakes up the world User Manual Coffee machine English V0.16

User guide supplement. Built-in oven NZ AU. Soft Touch electronic models

INSTALLATION & OPERATING GUIDE

IMPRESSA XJ5 Professional Instructions for Use. Original instructions for use Before using the machine read the instructions for use.

WE CAN HELP. Smart Coffee Maker User Manual. Can t connect? Need help? DO NOT RETURN THIS PRODUCT TO THE STORE

TRUSTED RELIABLE QUALITY

Please make sure to read the enclosed Ninja Owner s Guide prior to using your unit. WITH FRESHVAC TECHNOLOGY LET S BREAK IT DOWN

PUBLICIMBALI /2016 FEME Gruppo Cimbali S.p.A. Via Manzoni, Binasco (MI) Italy Tel

Welcome to the perfect pour!

INSTALLATION QUICK START GUIDE AND CHECKLIST ATTENTION!! DO NOT ATTEMPT A PARTIAL INSTALL.

EP3559, EP3558 EP3551, EP3550

the Bambino Plus Instruction Book - BES500

Organic Chemistry 211 Laboratory Gas Chromatography

F R E S H C U P. Single Serve Automatic Eject Pod System by:

INTRODUCTION TO CUSTOM FABRICATED STRAINERS

BEAN TO CUP ESPRESSO AND DE CAPPUCCINO MACHINE Instruction for use ECAM22.360

De Longhi Appliances via Seitz, Treviso Italy

5 Litre Party Keg Manual

2017 Summary of changes to rules for World Coffee In Good Spirits Championship

Natural quality pure enjoyment

Crem TechTM e-system Group Keypads + Oled Displays Main Display Hot Water Keypad Connectivity

Mode d'emploi Gebruiksaanwijzing Gebrauchsanweisung Instructions for use Hoja de Características Istruzioni d'uso

Transcription:

Medfusion 3500 V6 Syringe Infusion Pump Quick Reference Card

Medfusion 3500 v6 Syringe Infusion Pump 2 1 14 15 13 12 11 10 9 22 21 1. Tubing Holders 2. Carrying Handle 3. Syringe Barrel Clamp 4. Syringe Barrel Flange Clip 5. Syringe Plunger Holders 6. Syringe Plunger Driver 7. Syringe Plunger Release Lever 8. AC Power Connection Port 9. Power Key 10. Battery Indicator 11. AC line indicator

3 4 5 6 7 8 16 17 18 19 20 12. Alarm indicator 13. Alarm Silence Key 14. Infusing Indicators 15. Bolus Key 16. Start Key 17. Stop Key 18. Lock Indicator 19. Numeric Keypad 20. Back Key 21. Menu Keys (Soft Keys) 22. Display

Power On Press Power Key 9 to switch on the pump. Observe the self-test. Do not move the syringe plunger driver or otherwise manipulate the pump until the profile selection screen appears. Note: Connect pump to a power source 8 or check the battery meter after system self-tests are completed. Load Syringe (Refer to pump diagram) 1. Lift the syringe barrel clamp 3 and swivel it away rest it on the handle 2. 2. Squeeze the syringe plunger release lever 7 on the syringe plunger driver 6 and pull it out gently to extend it all the way outward. 3. Load the syringe onto the pump. Make sure the flange on the syringe barrel is secure in the syringe barrel flange clip 4. 4. Squeeze the syringe plunger release lever on the end of the syringe plunger driver and gently advance the plunger driver toward the syringe plunger. 5. Once it is flush with the syringe plunger, release the lever, so that both syringe plunger holders 5 close around the syringe plunger. 6. Turn and lower the barrel clamp onto the barrel of the syringe. 7. Verify that the correct syringe model and size are displayed and select Confirm. 8. Thread the tubing through the tubing holders 1 Some syringes may have similar outer dimensions, despite being different sizes (for example, BD 1mL Luer Lok and 3mL syringes), or even different models. In these cases, the pump will display options, requiring you to select the correct syringe size actually in use. Always verify that the syringe model shown is what you are actually using. Verify the correct syringe size when prompted and select Confirm.

Syringe Loading/Troubleshooting If syringe is incorrectly loaded, the pump displays arrows to show the problem: Check flange clip! Check plunger driver $ Check barrel clamp Program an Infusion Select profile Select category Select drug program Program infusion parameters Prime pump and administration set Confirm all settings Press start Options soft key can be selected for additional programming choices Note: Never prime any syringe while tubing is connected to a patient. Note: For timed infusions, a time entry will be required. An option to perform a fl ush could be prompted when the main infusion is complete.

Program a Loading Dose Program the infusion Select Options soft key Select loading dose Program loading dose parameters Confirm all settings Start the loading dose Loading dose will begin and main infusion will start automatically when loading dose is complete Program Bolus Dose Program the infusion Start the infusion Select Bolus key or the Options soft key Program bolus dose parameters Confirm bolus dose settings Start the bolus dose Main infusion will resume automatically when bolus dose is complete Bolus key Options soft key

Program a Flush Infusion Complete or Syringe Empty Stop displays and the pump will alarm Press Alarm Silence key Begin Flush Setup screen appears Select YES if the infusion is complete/syringe empty and the clinician desires to start the Flush process. Ensure the tubing is clamped and remove the empty infusion syringe and replace it with the flush syringe. Select the syringe model and size of the flush syringe. Enter the flush volume and press Enter. Select NO if the infusion is not complete and an additional syringe is required and return to the infusion programming screen The rate of the flush will default to the same rate of the previous infusion. If Flush Time is enabled in the software, the Confirm Same Rate prompt will display with the option (Yes or No) to infuse fl ush at the same rate as previous infusion. FlowSentry Pressure Monitor and Occlusion Detection FlowSentry Pressure Monitor and Occlusion Detection are two separate features in the pump that have separate algorithms, but work together to alert the clinician quickly about an increase in pressure within the infusion line. When pressure increases to the FlowSentry monitor sensitivity setting, the pump may trigger a pressure increasing or an occlusion alarm. A change in pressure can occur with more viscous solutions or positional IV access.

TVD is Total Volume Delivered It appears on the screen while the infusion is running. TVD is the total volume delivered to the patient, accumulated over multiple drug programs and infusions, and it will continue to accumulate until Clear TVD (or Clear Totals) is pressed or pump is turned off. It is useful information for documentation of total fl uid delivery to a patient. Note: The priming volume is not included in the TVD. PVD is Programmed Volume Delivered It appears briefly on the screen while the pump is paused, or by pressing the Back key. PVD is the accumulative volume delivered to the patient for the current infusion only. It is automatically cleared when the infusion ends and the pump is returned to the Main menu and can be cleared by pressing Clear Totals. This display totals the boluses, loading dose, and normal delivery volumes. It is useful for documentation of specific volume of medication delivered to a patient. PDD is Programmed Dose Delivered For this option to occur, it must be enabled in the PharmGuard Toolbox software. It is available by selecting Change to Dose under the Options soft key selection. PDD is the accumulative dose delivered to the patient for the current infusion only. It is automatically cleared when the infusion ends and the pump is returned to the Main menu and can be cleared by pressing Clear Totals. It is only available for continuous weight-based infusion modes when a dose has been programmed. This total includes the loading and/or bolus dose and the dose delivered for that infusion. It is useful for documentation of the specific medication dosing delivered to a patient.

Quick Library Programming Quick Library is an option that can be set up in a Configuration from the PharmGuard Toolbox medication safety software. With a Quick Library, starting an infusion can be as quick as Profile Drug Selection Start Infusion. Should a user need to change the dose or the patient s weight that was pre-entered, using the soft keys can enable them to do so. Power Off When powering off the pump the message Shutdown in Progress will appear briefl y on the pump display prior to completing power off.

Program Options Provide options that affect the current infusion only. The options available depend on the options that have been enabled for the profile and which have been customized for use in the medication safety software. Any options in use for a current infusion return to the default selection whenever the pump is powered off, or whenever the program is returned to the Main Menu prior to the beginning of the next infusion. Bolus Dose: Ability to allow a specific bolus dose or volume to be delivered (option can be programmed prior to starting, during an infusion, or when infusion is stopped). Dose will be programmed and delivered in the parameters of that specific infusion. Bolus dose must be enabled for the specific drug for this feature to appear on the pump. Delayed Start: Ability to pre-program an infusion then postpone the start for a programmed interval of time (option to program only available prior to starting an infusion, or when infusion is stopped). Delayed Start mode begins after entering the time parameters. The pump will automatically start the infusion at the end of the delayed start time. The infusion can be started at any time during delayed start by pressing the Start key. Loading Dose: Ability to allow a specific loading dose or volume to be delivered (option to program only available prior to starting an infusion, or when infusion is stopped). Dose will be programmed and delivered in the parameters of that specific infusion. Loading dose must be enabled for the specific drug for this feature to appear on the pump and will be delivered before the start of the main infusion. Periodic Callback Alarm: Allows programming of an alarm to be generated at a programmed period of time. It can be set in either hours or minutes (option can be programmed/changed prior to starting, during an infusion, or when infusion is stopped). The maximum allowable time is 8 hours. Standby: Allows pre-programming of an infusion then postponing the start for a programmed interval of time while maintaining the programmed settings until the infusion is started. Standby mode begins after entering the time parameters. Do not press the start key until it is time to start the infusion. The pump does not automatically start at the end of the standby period. The pump will sound an alarm notifying the clinician that Standby mode has ended. The infusion can be started at any time during standby by pressing the start key. Volume Limit: Allows a specific volume limit to be determined for an infusion (option to program only available prior to starting an infusion, or when infusion is stopped). Once the pump has delivered the volume limit, the pump will alarm and stop. This is only available for continuous infusions.

Program Options (continued) KVO: Ability to allow a KVO (Keep Vein Open) rate to be delivered between infusions (option to program only available prior to starting an infusion or when infusion is stopped). A volume limit must be programmed for KVO to function. KVO rates are determined by the minimum flow rate for the syringe currently being used and the current infusion rate, whichever is less. Override Alarm Loudness: Ability to override the profile selection for a specific infusion (option can be programmed prior to starting, during an infusion, or when infusion is stopped). Able to select from a higher or lower volume. The alarm cannot be totally disabled. Override Occlusion Limit: Ability to override the profile selection for a specific infusion (option can be changed prior to starting, during an infusion, or when infusion is stopped). Able to select from a higher or lower value. Disable/Enable FlowSentry : Ability to override the profile selection for a specific infusion (option can be changed prior to starting, during an infusion, or when infusion is stopped). Will either disable or enable FlowSentry pressure monitor. Disable/Enable Near Empty Tone: Ability to override the profile selection for a specific infusion. Will either disable or enable Near Empty tone (option can be changed prior to starting, during an infusion, or when infusion is stopped). If the tone is disabled, no audible alarm tone will occur. However, the message Syringe Near Empty will display, the alarm indicator light will illuminate, the display screen backlight will oscillate between bright and dim and the infusion will continue. Disable/Enable Volume Empty Tone: Ability to override the profile selection for a specific infusion (option can be changed prior to starting, during an infusion, or when infusion is stopped). Will either disable or enable Syringe Volume Near Empty tone. If the tone is disabled, no audible alarm tone will occur. However, the message Syringe Volume Near Empty will display, the alarm indicator light will illuminate, the display screen backlight will oscillate between bright and dim and the infusion will continue. Change to Dose/Change to Volume: Ability to have one or the other display on the pump during infusions (option can be changed prior to starting, during an infusion, or when infusion is stopped). PVD is an acronym that means Programmed Volume Delivered. PDD is an acronym that means Programmed Dose Delivered.

Override Occlusion Settings Override Occlusion Settings is a way to adjust the settings for the current infusion. This can be done by selecting the Options soft key, and selecting Override Occl Limit. The current setting will be highlighted. The choices are: 1. Very Low Most Sensitive (the occlusion alarm will be triggered quickly) - approx. 4 psi 2. Low - approx. 8 psi 3. Normal - approx. 12 psi 4. High Least Sensitive (the occlusion alarm will be triggered slowly) - approx. 16 psi Reverse Highlight Reverse Highlight occurs when a value was entered outside of the soft limits for any of the parameters while programming an infusion. An example of how this may look for a value that was overridden for a dose is shown below. Smiths Medical ASD, Inc. MPAUCA-1531 6000 Nathan Lane North Minneapolis, MN 55442, USA Tel: 1-614-210-7300 www.smiths-medical.com Find your local contact information at www.smiths-medical.com/customer-support/contact-us Smiths Medical is part of the global technology business Smiths Group plc. Product(s) described may not be licensed or available for sale in all countries. PharmGuard, FlowSentry, Medfusion and the Smiths Medical design mark are trademarks of Smiths Medical. The symbol indicates the trademark is registered in the U.S. Patent and Trademark Office and certain other countries. 2017 Smiths Medical. All rights reserved. IN193846EN-022017