HI FREE & TOTAL SULPHUR DIOXIDE MINITITRATOR for wine analysis

Similar documents
INSTRUCTION MANUAL Mi455

INSTRUCTION MANUAL Mi456

HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

HI Titratable Total Acidity Mini Titrator for Wine Analysis

Acidity and ph Analysis

Find out all you need to know about measuring SO 2. in wine making

Measuring Fluoride in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

INSTRUCTION MANUAL Mi453 Reducing Sugars

INSTRUCTION MANUAL Milwaukee Wine Lab Photometer Mi454 Tartaric Acid

AUTOMATIC BURR COFFEE GRINDER

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

TEA CATER USER MANUAL. UM_EN Part No.:

HI COLOR & PHENOLS ISM for wine analysis

THE COBURN COMPANY, INC. PO Box 147 Whitewater, WI U.S.A. Phone: Fax:

BREW EXPRESS OPERATION GUIDE MODEL BE112

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

Programmable Conical Burr Mill CBM-18

12 CUP COFFEE MAKER User Guide

BREW EXPRESS OPERATION GUIDE. model no. BE-112

Booklet_TCG-357_ENG.qxd 9/8/08 11:19 AM Page 1 COFFEE/SPICE GRINDER. Instruction Booklet. Model: TCG-357

WE CAN HELP. Smart Coffee Maker User Manual. Can t connect? Need help? DO NOT RETURN THIS PRODUCT TO THE STORE

左边 :SAFTY NOTES 右边 : Please follow the safety precautions to avoid any harm to yourself and cause any damages Never Always Warning Attention

COFFEE MAKER INSTRUCTION MANUAL CM4682-V

Pellet Pro 12 & 18 Lengths Large 35lb Hopper Assembly Operation Manual

IMPORTANT INSTRUCTIONS MODE D EMPLOI IMPORTANT INSTRUCIONES IMPORTANTES ISTRUZIONI IMPORTANTI

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

Micro Casa Semiautomatica

phd Pitcher UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

45-Cup Coffee Urn Big Brew Classic. Instruction Manual. Model ACU-045

CAIMANO SPECIAL450 BARISTA

Please read all directions before using the product and retain this guide for reference. This product is intended for household use only.

IMPORTANT SAFEGUARDS. 3. To protect against fire, electric shock and injury to persons do not immerse cord, plug or unit in water or other liquid.

OPERATING INSTRUCTIONS FOR YOUR SAFETY CAREFULLY READ THE OPERATING INSTRUCTIONS. FOR HOUSEHOLD USE ONLY

Scishare Coffee Machine

Alcolyzer Plus Spirits

Installation and User Instructions Flushing System Kit

1.5 L Slow Cooker 7644 Instructions for Use

DISCONTINUED VERSION The information in this manual is no longer current. Espresso/Cappuccino OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION

User Manual. Thermo Pump System Coffee Brewers User Manual. Models: 177C10, 177C15 04/2018. Please read and keep these instructions. Indoor use only.

Coffee Grinder Instruction Manual

Manual Spark Ignition (MSI) Kit For Use only with Thermocouple Manual Safety (TMSI) UL Approved Fire Pit Pans with Burning Spur

5.3QT DIGITAL 11-IN-1 INSTACOOKER Instruction Manual & Recipes MODEL CC5GT001

BBQ Grill. Owner s Manual Save These Instructions - For Household Use Only For Sizes: 12 x 18 & 12 x 12

Coffee Burr Grinder. Model #559. Instructions. Warranty

E N T E R P R I S E S

ORIGINAL LINE A USER MANUAL

The Scoop 2-Way Brewer

What's in the box 2 ENGLISH

CMC DUO. Standard version. Table of contens

User Manual. Stainless Steel Coffee Urn. Models: 177CU30 11/2018. Please read and keep these instructions. Indoor use only.

Electric Two-Speed Drink Mixer

User Manual. Stainless Steel Coffee Urns. Models: 177CU55ETL, 177CU110ETL 10/2016. Please read and keep these instructions. Indoor use only.

5KHM9212 W A_ENv7.indd 1 2/22/13 10:03 AM

User Manual. Stainless Steel Coffee Urns. Models: 177CU30, 177CU55, 177CU110 04/2018. Please read and keep these instructions. Indoor use only.

Quick Start Guide Read this booklet thoroughly and save these instructions.

5KEK1522 W A_01_EN.indd 1 11/16/12 1:22 PM

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

Vinmetrica SC-50 MLF Analyzer User Manual

COFFEE GRINDER. Owner s Manual

Downloaded from Quick Start Guide D512. Smart Decanter

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

INSTRUCTION MANUAL AND RECIPE BOOK CORN DOG MAKER CDM-1 SMART PLANET PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE.

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

Installation & Parts Manual 2" & 3" High Capacity Strainers For Class 1, Petroleum Applications

18-Bottle Dual Zone Slimline Edition Touchscreen Refrigerator

A N F I M Srl. Caimano On Demand. Super Caimano COFFEE GRINDER C O D Y S C O D Y - II. Model

Custom Grind Deluxe Coffee Grinder

ULTIMATE BLENDER 12 PIECE SET USER GUIDE READ ALL INSTRUCTIONS BEFORE USE AFTER SALES SUPPORT

CHOCOLINO CAFÉLINO USER MANUAL UM_EN. Part No.: _01

MODEL# GCM4500 COFFEE MAKER WITH GRINDER. PHOTO OF PRODUCT

User manual COFFEE QUEEN. Tower 10 litre for wall mounting. Your retail dealer. U / GB Rev

Luvele Grand Yoghurt Maker

User Guide TEA CATER. Your Dealer. U / EN Rev

TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

Burr Grinder. Model #551. Instructions. Warranty

TOASTER OVEN USER MANUAL MODEL: PKMFT039

instructions COFFEE GRINDER KG 79/89

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

Important Safety Information

K Mini Plus. Use & Care Guide. Get the most from your new Keurig brewer

LB 951. Istruzioni per l uso Instructions Mode d emploi Bedienungsanleitung Instrucciones de empleo Instruções de utilização Gebruiksaanwijzing

K35 Use & Care Guide. Get the most from your new Keurig coffee maker

QUICK START GUIDE F10 - F20

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

Coffeemaker User's manual

2016 Gourmia The Steelstone Group Brooklyn, NY

BULL. ASSEMBLY & OPERATING INSTRUCTIONS

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

USER MANUAL TECHNICAL DATA

Wi-Fi Coffee Maker. Model# GCMW-4750 USER MANUAL

AS450, AS600, G1, SG630

Built in Electric Fan Oven

MODELS 1315 & 1315-S La Pavoni CLUB COMBO

Coffee Burr Grinder. Model #591. Instructions. Warranty. 110W/120Vac/60 Hz. Read this manual thoroughly before using and save it for future reference

MODEL# GMF255 MOKA POT MILK FROTHER. PHOTO OF PRODUCT

Vinmetrica SC-100A User Manual

THE PANCAKE FACTORY. Model: PM-2

Vinmetrica SC-100A User Manual

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

Transcription:

SALES AND TECHNICAL SERVICE CONTACTS Australia: Tel. (03) 9769.0666 Fax (03) 9769.0699 China: Tel. (10) 88570068 Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 Fax (07851) 9129-99 Greece: Tel. (210) 823.5192 Fax (210) 884.0210 Indonesia: Tel. (21) 4584.2941 Fax (21) 4584.2942 Japan: Tel. (03) 3258.9565 Fax (03) 3258.9567 Korea: Tel. (02) 2278.5147 Fax (02) 2264.1729 Malaysia: Tel. (603) 5638.9940 Fax (603) 5638.9829 Singapore: Tel. 6296.7118 Fax 6291.6906 South Africa: Tel. (011) 615.6076 Fax (011) 615.8582 Taiwan: Tel. 886.2.2739.3014 Fax 886.2.2739.2983 Thailand: Tel. 66.2619.0708 Fax 66.2619.0061 United Kingdom: Tel. (01525) 850.855 Fax (01525) 853.668 USA: Tel. (401) 765.7500 Fax (401) 765.7575 MAN84100 09/05 Instruction Manual HI 84100 FREE & TOTAL SULPHUR DIOXIDE MINITITRATOR for wine analysis For e-mail contacts and a complete list of Sales and Technical offices, please see www.hannainst.com. 20 www.hannainst.com 1

Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com. This instrument is in compliance with directives. TABLE OF CONTENTS PRELIMINARY EXAMINATION... 3 GENERAL DESCRIPTION... 3 SPECIFICATIONS... 5 PRINCIPLE OF OPERATION... 6 FUNCTIONAL DESCRIPTION... 7 START UP... 9 GUIDE TO DISPLAY CODES... 10 TIPS FOR AN ACCURATE MEASUREMENT... 12 FREE SO 2 MEASUREMENT PROCEDURE... 12 TOTAL SO 2 MEASUREMENT PROCEDURE... 13 PUMP CALIBRATION PROCEDURE... 15 PUMP TUBE REPLACEMENT... 15 FUSE REPLACEMENT... 16 ELECTRODE CONDITIONING AND MAINTENANCE... 16 ACCESSORIES... 18 WARRANTY... 19 WARRANTY HI 84100 is warranted for two years against defects in workmanship and materials when used for its intended purpose and maintained according to the instructions. This warranty is limited to repair or replacement free of charge. Damage due to accident, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your dealer. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service Department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA. 2 WARRANTY Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 19

ACCESSORIES REAGENT SETS HI 70300L HI 70635L HI 70636L HI 7082 HI 84100-50 HI 84100-51 HI 84100-52 HI 84100-53 HI 84100-54 HI 84100-55 Electrode storage solution (500 ml) Cleaning solution for wine deposits (500 ml) Cleaning solution for wine stains (500 ml) Electrode filling solution (4 X 30 ml) Titrant solution (100 ml) Alkaline reagent (500 ml) Acid reagent for Total SO 2 determination (500 ml) Acid reagent for Free SO 2 determination (500 ml) Stabilizer reagent (25 pcs.) Calibration standard (500 ml) OTHER ACCESSORIES HI 3148B /50 ORP probe with 50 cm cable HI 70483T Tube set with cap for titrant bottle and tip HI 731316 Stir bar (5 pcs.) HI 740036P Beaker 50 ml (10 pcs.) HI 740037P Beaker 20 ml (10 pcs.) HI 740198 Power cable Recommendations for Users Before using this product, make sure that it is entirely suitable for your specific application and for the environment in which it is used. Operation of this instrument may cause unacceptable interferences to other electronic equipments, this requiring the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instrument EMC performance. To avoid damages or burns, do not put the instrument in microwave ovens. For yours and the instrument safety do not use or store the instrument in hazardous environments. 18 PRELIMINARY EXAMINATION Please examine this product carefully. Make sure that the instrument is not damaged. If any damage occured during shipment, please notify your Dealer. Each HI 84100 minititrator is supplied complete with: Reagents set for 20 titrations Two 50 ml beakers Two 20 ml beakers Scissors Tubes set with cap ORP probe Stir bar Power cable One 30 ml bottle of Refill Solution One 1 ml syringe Two sachets of cleaning solution for wine deposits Two sachets of cleaning solution for wine stains Instruction manual Note: Save all packing material until you are sure that the instrument works correctly. Any defective item must be returned in its original packing. GENERAL DESCRIPTION The HI 84100 is a low-cost, easy to use, microprocessor-based automatic titrator that benefits from Hanna s years of experience as a manufacturer of analytical instruments. It has a simple and reliable peristaltic pump that ensure high dosing repeatability. By performing pump calibration with the provided Hanna standards, the instrument accuracy is assured. The instrument comes with a pre-programmed analysis method designed for Free and Total Sulphur Dioxide measurements on wine samples. The instrument has a powerful and effective built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion. This algorithm automatize the analysis, makes all the necessary calculations and assures a simple and effective interface for the user. By simply pressing the START STOP button, the instrument will automatically make the titration up to the equivalence point. The result is immediately displayed in convenient units, then the instrument is ready for another titration. 3

SIGNIFICANCE OF USE An important reason for adding SO 2 is to avoid oxidation. When there is oxygen around, SO 2 itself becomes oxidized before phenol compounds in the wine, and so acts as an oxygen scavenger. Also SO 2 suppresses the activity of enzymes that cause browning and other problems. What is really protecting your wine is molecular SO 2. When you add SO 2, depending of circumstances, some of it immediately becomes bound. The relationship between the amount of added SO 2 and the amount of SO 2 remaining free is complex. It is clear, however, that it is largely governed by the total SO 2 content of the wine. The rate of binding decreases as the free SO 2 concentration increases. The exact relationship between free and bound (total - free) SO 2 will vary from wine to wine. Below 30-60 ppm, 33% to 50% of SO 2 addition becomes bounded. What remains is called free and it is divided in two parts. The larger, and relatively ineffective free part is bisulphite (HSO 3- ). The smaller part of the free is the active molecular SO 2. The amount of molecular SO 2 in your wine depends both on the level of free SO 2 present as well as ph. For instance, at ph 3.2, the amount of free SO 2 for 0.8 ppm molecular SO 2 is 22 ppm. At ph 3.5, you will need 43 ppm free - essentially double. Free SO 2 concentration (ppm) for 0.8 ppm molecular SO 2 : ph 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 Free SO 2 14 18 22 28 35 44 55 69 87 109 In most situations, 0.8 ppm molecular SO 2 during bulk storage and at bottling will provide you with adequate protection from oxidation and bacterial action. This includes prevention of malolactic bacteria as well. It is important to remember that the amount of free SO 2 in the wine depends on three things: how much is added, how much was present before the addition and how much of your addition promptly becomes bound. The level at which molecular SO 2 can be detected by the human senses is about 2.0 ppm. This is also the level which is needed for maximum protection of your wine. This is particularly true in the case of sweet, and most notably, botrytised wines. The Hanna HI 84100 offers the possibility to test free or total SO 2 in all the wines including the red ones, that are difficult to test with manual methods because the color changes are hardly seen. For faster response, unscrew the fill hole screw during measurements. STORAGE PROCEDURE To minimize clogging and assure a quick response time, the glass bulb and the junction of the electrode should be kept moist and not allowed to dry out. Replace the solution in the protective cap with a few drops of HI 70300 Storage Solution or, in its absence, Filling Solution (HI 7082). Follow the Preparation Procedure before taking measurements. Note: NEVER STORE THE ELECTRODE IN DISTILLED OR DEIONIZED WATER. PERIODIC MAINTENANCE Inspect the electrode and the cable. The cable used for connection to the instrument must be intact and there must be no points of broken insulation on the cable or cracks on the electrode stem or bulb. Connectors must be perfectly clean and dry. If any scratches or cracks are present, replace the electrode. Rinse off any salt deposits with water. Probe Maintenance Refill the reference chamber with fresh electrolyte (HI 7082). Allow the electrode to stand upright for 1 hour. Follow the Storage Procedure above. CLEANING PROCEDURE Wine deposits Soak in Hanna HI 70635 cleaning solution for 15 minutes Wine stains Soak in Hanna HI 70636 cleaning solution for 15 minutes IMPORTANT: After performing any of the cleaning procedures, rinse the electrode thoroughly with distilled water, refill the reference chamber with fresh electrolyte and soak the electrode in HI 70300 Storage Solution for at least 1 hour before taking measurements. 4 17

FUSE REPLACEMENT To change the fuse follow next steps: Disconnect the power cord from the rear panel of the instrument. Pull out the fuse holder located near the power cord connector. Replace the fuse with a similar one. Push the fuse holder with the fuse in the appropriate place. ELECTRODE CONDITIONING & MAINTENANCE SPECIFICATIONS Range 0 to 400 ppm of SO 2 Resolution 1 ppm Accuracy 5% of reading Method Ripper titrimetric method Principle Equivalence point redox titration Sample volume 50 ml ORP Electrode HI 3148B (included) Pump debit 0.5 ml/min Stirring speed 1500 rpm Environment 0 to 50 C (32 to 122 F); max 95% RH non-condensing Power supply 220V/50Hz; 10VA Dimensions 208 x 214 x 163 mm (8.2 x 8.4 x 6.4") (with beaker) Weight 2200 g (77.6 oz.) REQUIRED REAGENTS Code Description Quantity/test HI 84100-50 Titrant (for Free & Total SO 2 ) HI 84100-51 Alkaline Reagent (for Total SO 2 ) 5 ml HI 84100-52 Acid Reagent (for Total SO 2 ) 5 ml HI 84100-53 Acid Reagent (for Free SO 2 ) 5 ml HI 84100-54 Stabilizer (for Free & Total SO 2 ) 1 packet HI 84100-55 Standard (for Free & Total SO 2 ) 50 ml PREPARATION PROCEDURE Remove the protective cap of the ORP electrode (HI 3148B). DO NOT BE ALARMED IF SALT DEPOSITS ARE PRESENT. This is normal with electrodes. They will disappear when rinsed with water. During transport, tiny bubbles of air may form inside the glass bulb affecting proper functioning of the electrode. These bubbles can be removed by shaking down the electrode as you would do with a glass thermometer. If the bulb and/or junction is dry, soak the electrode in HI 70300 Storage Solution for at least one hour. If the filling solution (electrolyte) is more than 2½ cm (1 ) below the fill hole, add HI 7082 3.5M KCl Electrolyte Solution. 16 5

PRINCIPLE OF OPERATION Determination of sulphur dioxide in wine samples is made by titration of the sulphur dioxide present in wine with iodate. In this procedure an excess of iodine is added to the wine sample and it is titrated with iodate. The iodate reacts with iodide and the sulphuric acid present in the wine and produces iodine: IO 3 - + 5I - + 6H + = 3I 2 + 3H 2 O The iodine produced in the reaction above reacts then with the sulphur dioxide: H 2 SO 3 + I 2 + H 2 O = H 2 SO 4 + 2HI For precise results it is very important to know the exact sample volume, titrant volume and concentration. The peristaltic pump has a good repeatability but the dosing volume depends on many factors as the diameter of the tube or the tube stretching. To compensate for all this errors, the pump need to be calibrated. The calibration of the pump is also needed in order to have high precision of the titrations. The calibration procedure is in fact the analysis of a known solution. By doing this, the instrument makes a differential analysis between the standard and the wine sample. The pump volumetric debit and the real concentration of the titrant is compensated. Only the sample volume has to be precisely known. PUMP CALIBRATION PROCEDURE Warning: The calibration of the pump must be performed each time the pump tube, the reagent bottle or the ph electrode is changed. It is recommended to perform the pump calibration before each set of measurements. To prepare the sample for calibration, follow the measurement procedure for Free or Total SO 2 measurements by using HI 84100-55 Standard instead of wine sample. After sample preparation, press the CAL PUMP button. Std will blink on the screen. Press START STOP in order to start the system calibration. At the end of the calibration procedure done appears for a few seconds and then the meter automatically returns to measurement mode. PUMP TUBE REPLACEMENT To remove the tube of the peristaltic pump follow next steps: Detach the old tube system from the reagent bottle. Grasp one fixing ring of the peristaltic pump tube. Pull the tube until it s taken out from its location. Remove the other side of the tube. To mount the new peristaltic pump tube follow next steps: Position one peristaltic pump fixing ring on its location. Stretch the tube over the peristaltic pump cylinders. Fix the second pump fixing ring on its location. Attach the tube to the reagent bottle. Note: Purge the peristaltic pump until drops of reagent appears on the dosing tip by pressing the PURGE button. 6 15

Add the content of one powder packet of HI 84100-54 Stabilizer into the beaker. FUNCTIONAL DESCRIPTION INSTRUMENT DESCRIPTION FRONT PANEL Place the probe holder on the top of the beaker and secure it by turning clockwise. Immerse the ORP electrode approximately 2 cm (0.8 ) into the sample to be tested while paying attention to not touch the stir bar. Insert the dosing tip in the appropriate holder place and pay attention to not be immersed into solution. Press the START STOP button to start the titration. The display will show titr during titration, along with stirrer and pump tags blinking on the LCD. At the end of the titration, the Sulphur Dioxide concentration is displayed in ppm (mg/l). 1) Titrant bottle 2) Liquid Crystal Display (LCD) 3) Keypad 4) Electrode holder 5) Peristaltic pump tube REAR PANEL Note: If the equivalence point is not reached or it is not recognized because of the noisy solution, an error message will be displayed. 14 7

6) ORP Electrode 7) Beaker 8) BNC electrode connector 9) Fuse 10) Power switch 11) Power cable connector 12) Peristaltic pump KEYPAD DESCRIPTION Immerse the ORP electrode approximately 2 cm (0.8 ) into the sample to be tested while paying attention to not touch the stir bar. Insert the dosing tip in the appropriate holder place and pay attention to not be immersed into solution. Press the START STOP button to start the titration. The display will show titr during titration, along with stirrer and pump tags blinking on the LCD. At the end of the titration, the Sulphur Dioxide concentration is displayed in mg/l (ppm). 1) PURGE - to start/stop purging (max purging time is 5 min) 2) CAL PUMP - to enter pump calibration mode 3) START STOP - to start/stop titration or pump calibration 4) STIR - to start/stop the stirrer while in measurement or purging mode LCD DESCRIPTION Note: If the equivalence point is not reached or it is not recognized because of the noisy solution, an error message will be displayed. TOTAL SO 2 MEASUREMENT PROCEDURE Fill the 50 ml beaker up to the 50 ml mark with the wine sample, place the stir bar into the beaker and put the beaker in the appropriate place on the minititrator top. 1) Stability indicator: when the pump calibration is in progress 2) Stirrer active tags 3) Calibration messages 4) Pump active tags 5) Four digit secondary display 6) Time tag: when the time is displayed on the secondary display 7) ppm tag: when the titration result is displayed on the primary display 8) Four digit and half main display 8 Fill the 20 ml beaker up to the 5 ml mark with the HI 84100-51 Alkaline Reagent and add the content to the 50 ml beaker. Swirl the beaker and wait for 15 minutes. Fill the 20 ml beaker up to the 5 ml mark with the HI 84100-52 Acid Reagent and add the content to the 50 ml beaker. 13

TIPS FOR AN ACCURATE MEASUREMENT The instructions listed below should be carefully followed during testing to ensure best accuracy. Purge the peristaltic pump to have fresh titrant when starting a new analysis or calibration. Calibrate the peristaltic pump before performing an analysis. Analyze the wine immediately after the sample is obtained. Clean the electrode with the HI 700635 or HI 700636 cleaning solution, specially made for wine industry, if it was unused for a long time. FREE SO 2 MEASUREMENT PROCEDURE Warning: Make sure the pump was calibrated before performing sulphur dioxide wine sample analysis. START UP Place the instrument on a flat table. Do not place the instrument on direct sun light. Connect the titrator to mains socket with ground connection and the correct voltage and frequency. See the label on the instrument rear for this. Place the peristaltic pump tube on the pump. See the Pump Tube Replacement section for the procedure. Remove the reagent bottle cap and place the bottle cap of the tubes set. Place the reagent bottle in the appropriate place on the titrator top. Connect the tubes with the peristaltic pump (inlet tube is connected with the reagent bottle, outlet tube is connected with the dosing tip). Turn the instrument ON using the power switch from the rear panel of the instrument and wait until it displays dashes. Fill the 50 ml beaker up to the 50 ml mark with the wine sample, place the stir bar into the beaker and put the beaker in the appropriate place on the minititrator top. Fill the 20 ml beaker up to the 5 ml mark with the HI 84100-53 Acid Reagent and add the content to the 50 ml beaker. Add the content of one powder packet of HI 84100-54 Stabilizer into the beaker. Place the probe holder on the top of the beaker and secure it by turning clockwise. 12 9

GUIDE TO DISPLAY CODES This prompt appears for a few seconds each time the instrument is turned ON. This error message appears when the sample concentration exceeds 400 ppm. The used standard solution is wrong. Main screen display. Main screen display with stirrer active. This error message appears when the input readings (mv) exceed the input limits (0 1000mV). TITRATION MESSAGES Purging mode message. PUMP CALIBRATION MESSAGES This screen appears each time the meter enters pump calibration mode. The meter is ready to start pump calibration by pressing the START STOP button. This screen appears while pump calibration is in progress. Pressing CAL PUMP or START STOP button, the minititrator returns to the main screen. This prompt appears for a few seconds before returning to the main screen, when pump calibration is done. This screen appears each time the minititrator enters TITRATION mode. Press the START STOP button in order to stop the titration and return to the main screen. The titration result, expressed as concentration of sulphur dioxide in ppm(mg/l), is displayed at the end of the titration process. Press the START STOP button to return to the main screen. This error message appears when the input reading exceeds the input limits (0 1000mV). This screen appears when the sample concentration exceeds 400 ppm. 10 11