Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Similar documents
THE 195th CONFERENCE FOR PROMOTION OF FOOD IMPORT FACILITATION (FOOD SAFETY GROUP) Standards and Evaluation Division Department of Environmental Healt

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

Ochratoxin A N H. N-{ [(3R)-5-chloro-8-hydroxy-3-methyl-1-oxo-3,4-dihydro-1H-isochromen-7-yl]carbon yl}- L-phenylalanine

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

Bromine Containing Fumigants Determined as Total Inorganic Bromide

EXTRACTION PROCEDURE

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

PECTINASE Product Code: P129

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

EXTRACTION OF SEDIMENTS FOR AROMATIC AND CHLORINATED HYDROCARBONS

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

CHEM Experiment 4 Introduction to Separation Techniques I. Objectives

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

C27 Chromatography. Collect: Column Mortar and pestle Dropper (229 mm) Capillary tube TLC plate Aluminum foil UV light

TSKgel TECHNICAL INFORMATION SHEET No. 131

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Student Handout Procedure

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

The Separation of a Mixture into Pure Substances

Methanol (Resolution Oeno 377/2009, Revised by OIV-OENO 480/2014)

Title: Reagents Copy No: ## SOP No.: 3.13/3.1/S Effective Date: July 8, 2013 Location: ### Reagents

Avocado. recipe or working method? WLODEK. Wlodzimierz S. BOREJSZA-WYSOCKI Ph.D. IR-4 Southern Regional Laboratory Research Director

Zoe Grosser, Vinson Leung, Jim Fenster, Brian LaBrecque Horizon Technology, Inc., Salem, NH USA

Experiment 6 Thin-Layer Chromatography (TLC)

three different household steam ovens, representing a number of identically constructed ovens (see attached list at the end of this document):

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

General overview of the two stages of the QuEChERS technique. Stage 1: Sample extraction. Stage 2: Sample cleanup

One class classification based authentication of peanut oils by fatty

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Solid Phase Micro Extraction of Flavor Compounds in Beer

National Food Safety Standard

Experiment 3: Separation of a Mixture Pre-lab Exercise

Call for AOAC INTERNATIONAL Collaborator

Identification of reconstituted milk in pasteurized and UHT milk

Separations. Objective. Background. Date Lab Time Name

! " # # $% 004/2009. SpeedExtractor E-916

Determination of natamycin in wines Résolution OIV-SCMA

Chapter 14 Tex-619-J, Analysis of Water for Chloride and Sulfate Ions

DNA extraction method as per QIAamp DNA mini kit (Qiagen, Germany)

Profiling of Aroma Components in Wine Using a Novel Hybrid GC/MS/MS System

Determination of Caffeine in Coffee Products According to DIN 20481

Synthesis 0732: Isolating Caffeine from Tea

Tyler Trent, SVOC Application Specialist; Teledyne Tekmar P a g e 1

GAS-CHROMATOGRAPHIC ANALYSIS OF SOME VOLATILE CONGENERS IN DIFFERENT TYPES OF STRONG ALCOHOLIC FRUIT SPIRITS

E25 ISOLATION OF A BIOLOGICALLY ACTIVE COMPOUND The isolation of caffeine from tea leaves

FAT, TOTAL (Hydrolysis)

The Determination of Pesticides in Wine

Measuring tannins in grapes and red wine using the MCP (methyl cellulose precipitable tannin assay

EXTRACTION. Extraction is a very common laboratory procedure used when isolating or purifying a product.

CHAPTER 8. Sample Laboratory Experiments

Table 1: Experimental conditions for the instrument acquisition method

CHROMATOGRAPHY. Think about food Care about safety. Vol. 1 Melamine.

Practical 1 - Determination of Quinine in Tonic Water

ION FORCE DNA EXTRACTOR FAST Cat. N. EXD001

Setting up your fermentation

LAB: One Tube Reaction Part 1

DNA Extraction from Radioative Samples Grind plus kit Method

Introduction. Experimental. : : APPLICATION NOTE SP024: Pesticide Anaylsis: Standard QuEChERS vs Modified Method. : : APPARATUS: Geno/Grinder

ASSET EZ4-NCO Dry Sampler Extraction Procedure.

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Clove E-liquid Flavor Concentrate. PO Box 2624 Woodinville, WA 98072

Supporting Information

High Sensitivity Quantitation Method of Dicyandiamide and Melamine in Milk Powders by Liquid Chromatography Tandem Mass Spectrometry

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Cupcake Batter Flavor Concentrate

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

Analysis of Beta-Carotene and Total Carotenoids from Pacific Sea Plasma (Spectrophotometric Method)

Solid Phase Micro Extraction of Flavor Compounds in Beer

EDICT ± OF GOVERNMENT

Lab 2. Drug Abuse. Solubility and Colligative Properties of Solutions: Coffee, Soda, and Ice Cream

SYNTHESIS OF SALICYLIC ACID

EXPERIMENT 6. Molecular Fluorescence Spectroscopy: Quinine Assay

III. RESEARCH METHODOLOGY

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

Copyright JnF Specialties, LLC. All rights reserved worldwide.

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

RAPID, SPECIFIC ANALYSIS OF MELAMINE CONTAMINATION IN INFANT FORMULA AND LIQUID MILK BY UPLC/MS/MS

COMPENDIUM OF INTERNATIONAL METHODS OF ANALYSIS - OIV Volatile acidity. Volatile Acidity

Application Note CL0311. Introduction

Lab 2. Drug Abuse. Solubility and Colligative Properties of Solutions: Coffee, Soda, and Ice Cream

Higher Resolution Separation of Organic Acids and Common Inorganic Anions in Wine

Separating the Components of a Mixture

Separation of a Mixture

15. Extraction: Isolation of Caffeine from Tea

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

2. Other constituents in the sample solution should not interfere with the precipitation of the component of interest.

1. Blender: Osterizer, 10-speed, or equivalent. 2. Separatory Funnel: Kilborn or equivalent (see figure 1) 2. HCl Solution: HCl/water (7:93 by volume)

Allergens in wine a specific detection of Casein, Egg and Lysozyme

Test sheet preparation of pulps and filtrates from deinking processes

In the preparation of this Tanzania Standard assistance was derived from:

Preparation 1: Chloroform

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

Novel Closed System Extraction of Essential Oil: Impact on Yield and Physical Characterization

Estimation of Caffeine Concentration in Decaffeinated Coffee and Tea Available in Pakistan

COMMISSION OF THE EUROPEAN COMMUNITIES. Draft COMMISSION DIRECTIVE../ /EC

COMMISSION DIRECTIVE 2009/122/EC

Sequential Separation of Lysozyme, Ovomucin, Ovotransferrin and Ovalbumin from Egg White

EXPERIMENT NO. 3 HYDROMETER ANALYSIS ASTM D-422

CHAPTER XI STUDY OF STEROIDAL SAPOGENINS

Transcription:

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products) The target compound to be determined is coumaphos. 1. Instruments Gas chromatograph-flame thermionic detector (GC-FTD) Gas chromatograph-flame photometric detector (with interference filter for phosphorus, wavelength: 526 nm) (GC-FPD(P)) Gas chromatograph-nitrogen phosphorus detector (GC-NPD) Gas chromatograph-mass spectrometer (GC-MS) 2. Reagents Use the reagent listed in Section C Reagent/Test Solution, Etc., Part II Food additives, except the following. Acetonitrile: Use a reagent not containing any substance that may interfere with the Acetone: Use a reagent not containing any substance that may interfere with the Sodium Chloride: Use a reagent not containing any substance that may interfere with Silica gel for column chromatography (particle size of 63 to 200 μm): Heat silica gel made for column chromatography (particle size of 63 to 200 μm) at 130 C for 12 hours or longer. Cool down to room temperature in a desiccator. Diatomaceous earth: Use diatomaceous earth for chemical analysis. Ethyl acetate: Use a reagent not containing any substance that may interfere with Porous diatomaceous earth cartridge (to hold 20 ml of solution): A polyethylene tube of 20 30 mm in inside diameter packed with granular porous diatomaceous earth prepared for column chromatography (to hold 20 ml of solution), or a cartridge with equivalent to the specified one in separation capability. Trimethylaminopropylsilanized silica gel/ethylenediamine-n-propylsilanized silica gel layered cartridge (500 mg/500 mg): A polyethylene tube of 12 13 mm in inside diameter packed with 500 mg of trimethylaminopropylsilanized silica gel in the upper layer and 500 mg of ethylenediamine-n-propylsilanized silica gel in the lower layer, or a cartridge equivalent to the specified one in separation capability.

n-hexane: Use a reagent not containing any substance that may interfere with Water: Use water suitable for chemical analysis, including distilled water, purified water, or pure water. If it contains any substance that may interfere with analysis of the target compound, wash with a solvent such as n-hexane before use. Anhydrous sodium sulfate: Use a reagent not containing any substance that may interfere with 3. Reference standard Reference standard of coumaphos: Contains not less than 98% of coumaphos. 4. Procedure a. Extraction (i) Grains, legumes, nuts and seeds Grind sample to pass through a standard sieve (425 µm), weigh 10.0 g of the sample, add 20 ml of water, and let stand for 30 minutes. Add 100 ml of acetone to the sample, homogenize for 3 minutes, and filter through a filter paper, covered with a 1-cm-thick layer of diatomaceous earth, with suction into a vacuum rotary evaporator flask. Collect the residue on the filter paper, add 50 ml of acetone, homogenize for 3 minutes, treat as described above, combine the filtrate in the vacuum rotary evaporator flask, and remove acetone at below 40 C. Transfer to a 300 ml separating funnel containing 100 ml of saturated sodium chloride solution. Wash the vacuum rotary evaporator flask with 100 ml of ethyl acetate/n-hexane (1:4, v/v), and transfer the washing to the separating funnel. Shake the separating funnel vigorously for 5 minutes with a shaker, let stand, and transfer the ethyl acetate/n-hexane layer to a 300 ml conical flask. Add 50 ml of ethyl acetate/n-hexane (1:4, v/v) to the aqueous layer, treat as described above, and combine the ethyl acetate/n-hexane layers in the conical flask. Add an appropriate quantity of anhydrous sodium sulfate to the ethyl acetate/n-hexane layer, let stand for 15 minutes with occasional shaking, and filter into a vacuum rotary evaporator flask. Wash the conical flask with 20 ml of n-hexane, and wash the residue on the filter paper with the washing. Repeat this step one more time. Combine the washings in the vacuum rotary evaporator flask, and remove ethyl acetate/n-hexane at below 40 C. Add 30 ml of n-hexane to the residue, and transfer to a 100 ml separating funnel.

Add 30 ml of acetonitrile saturated with n-hexane to the separating funnel, shake vigorously for 5 minutes with a shaker, let stand, and transfer the acetonitrile layer to a vacuum rotary evaporator flask. Add 30 ml of acetonitrile saturated with n-hexane to the n-hexane layer, treat as described above twice, combine the acetonitrile layers in the vacuum rotary evaporator flask, and remove acetonitrile at below 40 C. Dissolve the residue in 5 ml of acetone/n-hexane (1:1, v/v). (ii) Fruits, vegetables, tea leaves and hops For fruits and vegetables, weigh about 1 kg of sample accurately, add an appropriate quantity of water (if necessary), homogenize, and then take the sample equivalent to 20.0 g. For tea leaves and hops, grind the sample, weigh 5.00 g, add 20 ml of water, and let stand for 30 minutes. Add 100 ml of acetone to the sample, homogenize for 3 minutes, and filter through a filter paper, covered with a 1-cm-thick layer of diatomaceous earth, with suction into a vacuum rotary evaporator flask. Collect the residue on the filter paper, add 50 ml of acetone, homogenize for 3 minutes, treat as described above, combine the filtrate in the vacuum rotary evaporator flask, and remove acetone at below 40 C. Transfer to a 300 ml separating funnel containing 100 ml of saturated sodium chloride solution. Wash the vacuum rotary evaporator flask with 100 ml of ethyl acetate/n-hexane (1:4, v/v), and transfer the washing to the separating funnel. Shake the separating funnel vigorously for 5 minutes with a shaker, let stand, and transfer the ethyl acetate/n-hexane layer to a 300 ml conical flask. Add 50 ml of ethyl acetate/n-hexane (1:4, v/v) to the aqueous layer, treat as described above, and combine the ethyl acetate/n-hexane layers in the conical flask. Add an appropriate quantity of anhydrous sodium sulfate to the ethyl acetate/n-hexane layer, let stand for 15 minutes with occasional shaking, and filter into a vacuum rotary evaporator flask. Wash the conical flask with 20 ml of n-hexane, and wash the residue on the filter paper with the washing. Repeat this step one more time. Combine the washings in the vacuum rotary evaporator flask, and remove ethyl acetate/n-hexane at below 40 C. Dissolve the residue in 5 ml of acetone/n-hexane (1:1, v/v). (iii) Muscle, fat, liver, kidney and fish/shellfish For muscle, liver, kidney and fish/shellfish, weigh 20.0 g of sample. For fat, weigh 5.00 g of sample. Add 20 ml of 0.1 mol/l hydrochloric acid to the sample, homogenize, add 100 ml of acetone/n-hexane (1:2, v/v), homogenize again, centrifuge at 3,000 rpm for 5 minutes, and collect the organic layer. Add 50 ml of n-hexane to the residue, homogenize, and

centrifuge at 3,000 rpm for 5 minutes. Combine the resulting organic layers, dehydrate the extract with anhydrous sodium sulfate, and filter out the anhydrous sodium sulfate. Concentrate the filtrate at below 40ºC and remove the solvent. Dissolve the residue in n-hexane to make exactly 20 ml. (iv) Milk, egg and honey Weigh 10.0 g of sample. Add 10 ml of 0.1 mol/l hydrochloric acid to the sample, homogenize, add 100 ml of acetone/n-hexane (1:2, v/v), homogenize again, centrifuge at 3,000 rpm for 5 minutes, and collect the organic layer. Add 50 ml of n-hexane to the residue, homogenize, and centrifuge at 3,000 rpm for 5 minutes. Combine the resulting organic layers, dehydrate the extract with anhydrous sodium sulfate, and filter out the anhydrous sodium sulfate. Concentrate the filtrate at below 40ºC and remove the solvent. For milk and egg, dissolve the residue in n-hexane to make exactly 10 ml. For honey, dissolve the residue in acetone/n-hexane (1:9, v/v) to make exactly 5 ml. b. Clean-up (i) Grains, legumes, nuts and seeds, fruits, vegetables, tea leaves and hops Place 5 g of silica gel for column chromatography (particle size of 63 to 200 μm) suspended in acetone/n-hexane (1:1, v/v), and then about 5 g of anhydrous sodium sulfate in a chromatographic tube of 15 mm in inside diameter and 300 mm in length, and let flow out acetone/n-hexane (1:1, v/v) to the extent that only a small quantity of acetone/n-hexane (1:1, v/v) remains on the top of the column. Transfer the solution obtained in a. Extraction to the column, elute with 100 ml of acetone/n-hexane (1:1, v/v), collect the eluate in a vacuum rotary evaporator flask, and remove the acetone/n-hexane at below 40 C. Dissolve the residue in acetone to make exactly 5 ml, and use this solution as the test solution. (ii) Muscle, fat, liver, kidney, fish/shellfish, milk and egg 1 Porous diatomaceous earth column chromatography For Muscle, fat, liver, kidney and fish/shellfish, transfer exactly 10 ml of the solution obtained in a. Extraction (iii) to a porous diatomaceous earth column (to hold 20 ml of solution). For milk and egg, transfer total solution obtained in a. Extraction (iv) to the column. Let stand the column for 10 minutes, and then aspirate the column for 10 minutes and remove most of the solvent. Elute with 90 ml of acetonitrile saturated with n-hexane, concentrate the eluate at below 40ºC and remove the solvent. Dissolve the residue in acetone/n-hexane (1:9, v/v) to make exactly 5 ml.

2 Trimethylaminopropylsilanized silica gel/ethylenediamine-n-propylsilanized silica gel layered column chromatography Add 10 ml of acetone/n-hexane (1:9, v/v) to a trimethylaminopropylsilanized silica gel/ethylenediamine-n-propylsilanized silica gel layered cartridge (500 mg/500 mg), and discard the effluent. Transfer exactly 2 ml of the solution obtained in 1 Porous diatomaceous earth column chromatography to the cartridge, elute with 10 ml of acetone/n-hexane (1:9, v/v), collect the total eluate, concentrate at below 40ºC and remove the solvent. Dissolve the residue in acetone/n-hexane (1:9, v/v) to make exactly 4 ml (1 ml for fat), and use this solution as the test solution. (iii) Honey Add 10 ml of acetone/n-hexane (1:9, v/v) to a trimethylaminopropylsilanized silica gel/ethylenediamine-n-propylsilanized silica gel layered cartridge (500 mg/500 mg) and discard the effluent. Transfer exactly 2 ml of the solution obtained in a. Extraction (iv) to the cartridge, elute with 10 ml of acetone/n-hexane (1:9, v/v), collect the total eluate, concentrate at below 40 C and remove the solvent. Dissolve the residue in acetone/n-hexane (1:9, v/v) to make exactly 4 ml, and use this solution as the test solution. 5. Measurement a. Calibration curve (i) Grains, legumes, nuts and seeds, fruits, vegetables, tea leaves and hops Prepare coumaphos standard solutions (acetone) of several concentrations. Inject each standard solution to GC-FTD, GC-FPD(P) or GC-NPD, and make a calibration curve by peak-height or peak-area method. When the test solution is prepared following the above procedure, the sample containing 0.01 mg/kg of coumaphos gives the test solution of 0.02 mg/l for grains, legumes, nuts and seeds, 0.04 mg/l for fruits and vegetables, and 0.01 mg/l for tea leaves and hops in concentration. (ii) Muscle, fat, liver, kidney, fish/shellfish, milk, egg and honey Prepare coumaphos standard solutions (acetone/n-hexane (1:9, v/v)) of several concentrations. Inject each standard solution to GC-FTD, GC-FPD(P) or GC-NPD, and make a calibration curve by peak-height or peak-area method. When the test solution is prepared following the above procedure, the sample containing 0.01 mg/kg of coumaphos gives the test solution of 0.01 mg/l in concentration. b. Quantification Inject the test solution to GC-FTD, GC-FPD(P) or GC-NPD, and calculate the

concentration of coumaphos from the calibration curve made in a. Calibration curve. c. Confirmation Confirm using GC-MS. d. Measurement conditions (i) For quantification Condition 1 (GC-FTD, GC-FPD(P) or GC-NPD) Column: Silicate glass capillary column 0.53 mm in inside diameter, 10 30 m in length coated with methyl silicone for gas chromatography 1.5 μm in film thickness Column temperature: The column temperature is held at 80 C for 1 minute, followed by an increase of 8 C every minute until reaching 250 C, where it is held for 5 minutes. Inlet temperature: 230 C Detector temperature: 280 C Gas flow rate: Helium is used as the carrier gas. The flow rate should be adjusted to the optimal condition. The flows of air and hydrogen should also be adjusted to the optimal conditions. Condition 2 (GC-FTD, GC-FPD(P) or GC-NPD) Column: Silicate glass capillary column 0.32 mm in inside diameter, 10 30 m in length coated with 50% trifluoro propyl methyl silicone for gas chromatography 0.25 μm in film thickness Column temperature: The column temperature is held at 70 C for 1 minute, followed by an increase of 25 C every minute until reaching 125 C, after which the temperature is increased by 10 C every minute until reaching 235 C, where it is held for 12 minutes. Inlet temperature: 230 C Detector temperature: 280 C Gas flow rate: Helium is used as the carrier gas. The flow rate should be adjusted to the optimal condition. The flows of air and hydrogen should also be adjusted to the optimal conditions. Condition 3 (GC-FPD(P)) Column: Silicate glass capillary column 0.32 mm in inside diameter, 30 m in length coated with 35% trifluoro propyl methyl silicone for gas chromatography 0.5 μm in film thickness

Column temperature: The column temperature is held at 60 C for 1 minute, followed by an increase of 25 C every minute until reaching 210 C, after which the temperature is increased by 10 C every minute until reaching 280 C, where it is held for 10 minutes. Inlet temperature: 250 C Detector temperature: 280 C Gas flow rate: Helium is used as the carrier gas. The flow rate should be adjusted to the optimal condition. The flows of air and hydrogen should also be adjusted to the optimal conditions. Injection volume: 2 μl Expected retention time: 18 min (ii) For confirmation Condition (GC-MS) Column: Silicate glass capillary column 0.25 mm in inside diameter, 30 m in length coated with 5% phenyl-methyl silicone for gas chromatography 0.25 μm in film thickness Column temperature: The column temperature is held at 60 C for 1 minute, followed by an increase of 25 C every minute until reaching 210 C, after which the temperature is increased by 10 C every minute until reaching 300 C, where it is held for 8 minutes. Inlet temperature: 250 C Carrier gas: Helium is used as the carrier gas. The flow rate should be adjusted to the optimal condition. Ionization mode (ionization energy): EI (70 ev) Major monitoring ions (m/z): 364, 362, 226 Injection volume: 2 μl Expected retention time: 15 min 6. Limit of quantification 0.01 mg/kg