TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER

Similar documents
E N T E R P R I S E S

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

WMF 1200S. Operating & cleaning instructions Malvern Road Glen Iris VIC 3146 ph: fax:

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

Installation and User Instructions Flushing System Kit

Grind by Weight Accessory. Operations Manual. ESATTO TM shown with Preciso TM Grinder

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

WE CAN HELP. Smart Coffee Maker User Manual. Can t connect? Need help? DO NOT RETURN THIS PRODUCT TO THE STORE

BREW EXPRESS OPERATION GUIDE. model no. BE-112

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

BREW EXPRESS IMPORTANT NOTE: model no. BE-104 & BE-110. For more information see our instructional video online at

Medfusion 3500 V6. Syringe Infusion Pump. Quick Reference Card

Operating the Rancilio Silvia after PID kit modification Version 1.1


Armonia Smart. Quick Start Guide MACHINE DESCRIPTION STARTING UP

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

E N T E R P R I S E S

Burr Grinder. Automatic burr grinder with 17-position grind selector. Instruction Booklet EM0430

Automatic Coffee Machine Instruction Manual

OMEGA PRODUCTS, INC LYSTER LANE HARRISBURG, PA U.S.A. PHONE: FAX:

CAFE BARISTA. User Guide EM5000

Coffee Burr Grinder. Model #559. Instructions. Warranty

BREW EXPRESS OPERATION GUIDE MODEL BE112

Triple Brew. Model #352. Coffee & Tea Maker. Instructions Warranty

User Guide TEA CATER. Your Dealer. U / EN Rev

Conical Burr Coffee Grinder. Operations Manual

Machine No. 2, SV=104. Figure 1

For Jura parts, repairs & tech support, contact: Services Unlimited, Inc./ Parts Guru

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

What's in the box 2 ENGLISH

Programming Guide For EXTRACTOR Coffee Brewers (CBS 2000e Series)

BarAroma Coffee & Spice Grinder

Jura Impressa XF50. Operating & cleaning Instructions Malvern Road Glen Iris VIC 3146 ph: fax:

CMC DUO. Standard version. Table of contens

AS450, AS600, G1, SG630

Manual Spark Ignition (MSI) Kit For Use only with Thermocouple Manual Safety (TMSI) UL Approved Fire Pit Pans with Burning Spur

Instruction Manual Coffee grinder. CM 90 Serie

Burr Grinder. Model #551. Instructions. Warranty

Wega Mininova 2003 Installation Instructions

Chicken Rotisserie. Model LM-8A LM-12A LM-8M LM-12M Instruction Manual

COFFEE GRINDER. Owner s Manual

Thank you for your purchase!

INSTRUCTION MANUAL FOR BUILT-IN OVENS

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

MG600 PLUS, Model #484 (Glass) 10-Cup Programmable Coffee Maker with Stainless Steel Housing. Operating Instructions Product Registration Warranty

MTN Products. AquaCafé r (Touch Capsules) Installation & Operations Manual

IMPORTANT SAFEGUARDS. When using electrical appliances, basic safety precautions should always be followed, including the following:

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

A N F I M Srl. Caimano On Demand. Super Caimano COFFEE GRINDER C O D Y S C O D Y - II. Model

COFFEE MAKER INSTRUCTION MANUAL CM4682-V

Conv. Pre Heat. Speed. bake. clean. Conv. Bake time. Clean. convert. Maxx clean. Conv. Broil. roast. Oven

MODELS 1315 & 1315-S La Pavoni CLUB COMBO

MANUAL FOR USE AND MAINTENANCE. Vivaldi LSC 008 REV. 01

TILT-HEAD STAND MIXER FEATURES

Hotpoint H/A - Ariston automatic, built-in coffee machine MCX 103 X - MCK 103 X/HA

Operation and Service Manual

QWIKBREW 2 TWIN 5.6kW (P/N: )

INTRODUCTION. Your new smoker comes almost completely assembled. You will need to complete the assembly which includes:

2016 Gourmia The Steelstone Group Brooklyn, NY

QUICK START GUIDE F10 - F20

INSTALLATION AND WARRANTY CERTIFICATE. Machine model Serial Number # Rating and optional. Installation Company: Technician ID: Date: / /

DISCONTINUED VERSION The information in this manual is no longer current. Espresso/Cappuccino OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION

Clean and sanitize hot sundae topping pumps Weekly SS 1 W3

Quick Start Guide Read this booklet thoroughly and save these instructions.

3-in-1 K-Cup Coffee Maker

SG120 Model # Cup Stainless Steel Coffee Maker. Operating Instructions Product Registration Warranty

INSTALLATION & OPERATING GUIDE

GENERAL OPERATING RULES

User guide supplement. Built-in oven NZ AU. Soft Touch electronic models

Coffee Burr Grinder. Model #591. Instructions. Warranty. 110W/120Vac/60 Hz. Read this manual thoroughly before using and save it for future reference

Pellet Pro 12 & 18 Lengths Large 35lb Hopper Assembly Operation Manual

SETTE 270 MANUAL INTRODUCTION Conical Burrs Digital Control Panel Convertible Device Holder Grind Adjustment

Get Started. Better Everyday ECAM23260

Using your Grinder: Fig.1 Fig. 2

Uno xl electronic. Turnspit.

...WITH A PASSION FOR COFFEE. User manual. CQ Future BTC. Your retail dealer U_GB ... Rev

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

SAVE THESE INSTRUCTIONS

HD8828 HD8834 USER MANUAL. Super automatic espresso coffee machine 3100 series. Read carefully before using the machine.

IKAWA App V1 For USE WITH IKAWA COFFEE ROASTER. IKAWA Ltd. Unit 2 at 5 Durham Yard Bethnal Green London E2 6QF United Kingdom

12 CUP COFFEE MAKER User Guide

ELECTRONIC OVEN CONTROL GUIDE

CM200, Model # Cup Programmable Coffee Maker. Operating Instructions Product Registration Warranty

EP3559, EP3558 EP3551, EP3550

Operator Manual 100 Series Coffee Grinders

MODEL# GCM5000 K CUP & ESPRESSO COFFEE MAKER

SET UP / OPERATION GUIDE

BUILT IN DELUXE SPIT BRAAI MODELS: 1200 & 1500

PLEASE READ THIS MANUAL BEFORE USE. SAVE FOR FUTURE REFERENCE.

F G H

INSTRUCTION MANUAL. Coffee Maker CMCM-100

MARCO BEVERAGE SYSTEMS LTD.

BZ35 Espresso Machine

Model GPX Precision Disc Style Coffee Grinder

INSTALLATION QUICK START GUIDE AND CHECKLIST ATTENTION!! DO NOT ATTEMPT A PARTIAL INSTALL.

MODELS SHOWN: BICM24CS BUILT-IN COFFEE MACHINE AND WDC30JP WARMING DRAWER

coffee wakes up the world User Manual Coffee machine English V0.16

Micro Casa Semiautomatica

2007 Miele USA. TECHNICAL INFORMATION CVA615 Coffee System

Conical Burr Coffee Grinder. Operations Manual

Transcription:

instrumentation and software for research TRIPLE INFUSION PUMP WITH AUTOMATIC CYCLING TIMER PHM-102 / PHM-102A USER S MANUAL DOC-183 Rev. 2.1 Copyright 2016 All Rights Reserved P.O. Box 319 St. Albans, Vermont 05478 Phone: 802.527.2343 Fax: 802.527.5095 www.med-associates.com

This page intentionally left blank

Table of Contents Chapter 1 Introduction... 1 Specifications... 1 Chapter 2 Syringe Placement... 2 Priming the Line... 2 Chapter 3 User Interface... 3 START/RESET Button... 3 FLUSH Switch... 4 Automatic Shut-Off Switch... 4 PHM-102... 5 PHM-102A... 5 Chapter 4 Operating Instructions... 6 Manual Operation... 6 Single Timed Infusion... 6 Continuous Cycling Operation... 6 Example of CYCLE Time INFUSION Time... 7 Example of CYCLE Time > INFUSION Time... 8 Appendix A Contact Information... 8 - iii - DOC-183 Rev. 2.1 Copyright 2016

Notes Diagrams - iv - DOC-183 Rev. 2.1 Copyright 2016

CHAPTER 1 INTRODUCTION The PHM-102 Triple Infusion Pump with Automatic Cycling Timer is designed to provide infusions at user-defined intervals. The CYCLE pushbutton switches are used to set the interval between infusions and the INFUSION pushbutton switches set the duration of the infusion(s). The function of these switches is covered in greater detail in the User Interface section of this manual. The pump is also equipped with LEDs on the face panel that indicates whether the pump is cycling or infusing. This pump uses a 3.33-RPM motor and is intended to be used with 30 ml BD Plastipak TM syringes. Specifications Motor Speed: 3.33 RPM Infusion Rate*: 143 ml/hr (2.4 ml/min) Syringe Type: 30 ml Becton-Dickinson Plastic Infusion Durations: PHM-102: 1 99 sec PHM-102A: 0.1 9.9 sec or 1 99 sec Infusion Intervals: PHM-102: 1 99 min PHM-102A: 1 99 min or 1 99 hrs * Assuming a 30 ml Becton-Dickinson Plastic syringe is used. - 1 - DOC-183 Rev. 2.1 Copyright 2016

MED ASSOCIATES, INC. CHAPTER 2 SYRINGE PLACEMENT Care should be exercised that the syringe barrel is positioned firmly in the syringe clamp. If a gap exists between the tabs and the clamp, accurate flow rates cannot be assured, as the entire syringe (both barrel and plunger) may move forward. It is advised that a visual check be performed turning the knob on the front of the pump and observing the plunger move in relation to the barrel. Figure 1 shows the procedure for loading a syringe into the pump. Figure 1 - Syringe Loading Procedure 1. Move the slide to rear (toward motor section) by squeezing the jaws. 2. Insert syringe(s) into the triple syringe clamp by placing the syringe barrel into the clamp and pressing down firmly. Be sure that the tabs on the syringe are pressed against the clamp, as shown. 3. Move the slide to the end of the syringe plunger(s). 4. Rotate the knob so that the slide makes contact with the plunger(s) and the syringe tabs contact the clamp. Priming the Li ne Once the syringe is installed, the line should be primed until liquid drips out of the syringe or tubing. This ensures that fluid will be infused properly when the pump is activated. To prime the infusion line set the FLUSH switch to the on, or down, position for as long as required (Until liquid drips from the distal end of the infusion line). The settings of the CYCLE and INFUSION pushbutton switches are not recognized when the FLUSH switch is on. The pump will operate at 3.33 RPM until the FLUSH switch is set to the off or up position. -2- DOC-183 Rev. 2.1 Copyright 2016

CHAPTER 3 USER INTERFACE The User Interfaces of the PHM-102 and the PHM-102A operate in the much the same way. The PHM- 102A has two additional switches that allow the user to select the unit of time for the Cycle and Infusion. The function of all of these buttons and switches is described in detail below. Figure 2 - PHM-102 User Interface Figure 3 - PHM-102A User Interface START/RESET Button Pressing START/RESET will start the pump. It will run according to the user-defined CYCLE and INFUSION durations. If the START/RESET button is pressed while the pump is running it will stop the pump and reset the timer. - 3 - DOC-183 Rev. 2.1 Copyright 2016

MED ASSOCIATES, INC. FLUSH Switch When the FLUSH switch is on or down the pump will infuse until it is switch off or up. The settings of the CYCLE and INFUSION switches are not recognized when the FLUSH switch is on. The FLUSH switch will operate at any time during all phases of pump operation. Automatic Shut-Off Switch The automatic shut-off switch is activated when the pump reaches the end of the syringe, causing the pump motor to cease operation. The automatic shut-off switch uses an internal micro-switch that detects when the slide assembly reaches a certain point. This point is adjustable so that the pump can accommodate various sizes and brands of syringes. To adjust the automatic shut-off switch, insert an empty syringe with the plunger at the desired shut-off position. Move the slide assembly to the rear of the plunger (Figure 4A). With the pump turned on, switch the FLUSH switch on and rotate the adjustment screw (Figure 4B) until the pump stops operating. Each clockwise ½ turn of the adjustment screw will cause the switch to activate.025 inches further, and each counterclockwise ½ turn of the adjustment screw will cause the switch to activate.025 inches sooner. In order to reset this switch and resume pump operation the slide must be moved back until the Automatic Shut-Off Switch is deactivated. Figure 4 - Automatic Shut-Off Switch Adjustment -4- DOC-183 Rev. 2.1 Copyright 2016

PHM-102 Cycle Pushbuttons The CYCLE pushbuttons switches are used to set the cycle time. The unit of the cycle time is minutes. (Range of the cycle is 1-99 minutes). Cycle LED If the pump is cycling, the CYCLE LED will blink on for 0.5 seconds and off for 0.5 seconds. Infusion Pushbuttons The INFUSION pushbutton switches are used to set the infusion time. The unit of the infusion time is seconds. (Range of the infusion time is 1 99 seconds). Infusion LED If the pump is infusing the INFUSION LED will blink on for 0.5 seconds, then off for 0.5 seconds. PHM-102A Cycle Controls The CYCLE pushbutton switches are used to set the cycle time. The units of the cycle time may be changed from hours to minutes using the hrs/mins toggle switch. This means that the range of the cycle time is 1 99 minutes or 1 99 hours, depending on the position of the hrs/mins switch. Cycle LED If the pump is cycling, the CYCLE LED will be flashing. If the hrs/mins switch is set to hours the CYCLE LED will blink on for one second, then off for one second and if it is set to minutes it will blink on for 0.5 seconds and off for 0.5 seconds. Infusion Controls The INFUSION pushbutton switches are used to set the infusion time. The units of the infusion time may be changed from seconds to tenths of seconds using the sec/0.1 secs toggle switch. This means that the range of the infusion time is 0.1 9.9 seconds or 1 99 seconds, depending on the position of the sec/0.1 secs toggle switch. Infusion LED If the pump is infusing the INFUSION LED will be flashing. If the sec/0.1 secs switch is set to seconds the INFUSION LED will blink on for 0.5 seconds, then off for 0.5 seconds and if it is set to tenths of seconds it will blink on for 0.1 second and off for 0.1 second. START/RESET Button Pressing START/RESET will start the pump. It will run according to the user-defined CYCLE and INFUSION durations. If the START/RESET button is pressed while the pump is running it will stop the pump and reset the timer. - 5 - DOC-183 Rev. 2.1 Copyright 2016

CHAPTER 4 OPERATING INSTRUCTIONS Load the syringe(s) according to the instructions. Connect the power cord to a standard wall outlet and power the pump on using the red ON/OFF switch. If the pump is plugged in and powered on, the red ON/OFF switch will be illuminated. Manual Operation The pump can be operated manually to flush the lines or to provide an untimed infusion by simply turning the FLUSH switch on or down for as long as required. The FLUSH switch will operate at any time during all phases of operation. Single Timed Infusion A single timed infusion can be produced by setting the INFUSION switches to the desired duration and the CYCLE pushbutton switches to 00. When the START/RESET button is pressed the pump will run for the set infusion time and then stop. Once the infusion is complete the START/RESET button must be pressed again to produce another infusion. Continuous Cycling Operation For continuous cycling, set the CYCLE and INFUSION switches to the desired settings. It is important to note that the cycle time is dependent on the relationship between the CYCLE and INFUSION settings. If the CYCLE time is less than or equal to the INFUSION time, then the CYCLE time will be completed before the INFUSION time starts. If the CYCLE time is greater than the INFUSION time then the INFUSION time will be subtracted from the CYCLE time. This is illustrated in Figure 5 and Figure 6. Figure 5 - If CYCLE Time INFUSION Time Figure 6 - If CYCLE Time > INFUSION Time Once the pushbuttons switches are set to the desired CYCLE and INFUSION times, press the START/RESET button to begin continuous operation. The pump will begin with the CYCLE time, then start the INFUSION, and will repeat infusions at equal time intervals thereafter. The CYCLE and - 6 - DOC-183 Rev. 2.1 Copyright 2016

INFUSION LEDs will indicate what phase of operation thepump is currently in. The User Interface section of this manual describes the function of these LEDs in detail. To stop the cycling operation at any time press the START/RESET button. This will stop the operation of the pump and reset the timer. Example of CYCLE Time INFUSION Time For example, if the toggle and pushbuttons switches on the PHM-102 are set as shown in Figure 7, then the cycle and infusion times are equal (CYCLE is set to one minute and INFUSION is set to 60 seconds). This means that the cycle time will be completed before the infusion time begins, as illustrated in Figure 8. When the START/RESET button is pressed, the cycle will begin. The CYCLE LED will be blinking on for 0.5 seconds and off for 0.5 seconds. The cycle will last for one minute, and then the INFUSION will begin. The INFUSION LED will be blinking on for 0.5 seconds then off for 0.5 seconds. Once this infusion is complete another cycle will start unless the START/RESET button is pressed, which will stop the operation of the pump and reset the timer. Figure 7 PHM-102 Pump Settings with CYCLE Time INFUSION Time Figure 8 - Illustration of Example - 7 - DOC-183 Rev. 2.1 Copyright 2016

Example of CYCLE Time > INFUSION Time If the toggle and pushbutton switches on a PHM-102A are set as shown in Figure 9, then the cycle time is greater than the infusion time (CYCLE is set to five hours and INFUSION is set to 0.5 seconds). This means that the infusion time will be subtracted from the cycle time, as illustrated in Figure 10. When the START/RESET button is pressed, the cycle will begin. The CYCLE LED will be blinking on for 1 second and off for 1 second. The cycle will last for four hours, 59 minutes and 59.5 seconds and then the 0.5-second INFUSION will begin. The INFUSION LED will be blinking on for 0.1 second then off for 0.1 second. Once this infusion is complete another cycle will start unless the START/RESET button is pressed, which will stop the operation of the pump and reset the timer. Figure 9 PHM-102A Pump Settings with CYCLE Time > INFUSION Time Figure 10 - Illustration of Example APPENDIX A CONTACT INFORMATION Please contact for information regarding any of our products. For Technical questions, email support@med-associates.com. For Sales questions, email sales@med-associates.com. Visit our website at www.med-associates.com. - 8 - DOC-183 Rev. 2.1 Copyright 2016