Identification and Semiquantitation of Monoterpene Glycosides in Ripening Muscat of Alexandria Grapes

Similar documents
Metabolomic Profiling of Wines using LC/QTOF MS and MassHunter Data Mining and Statistical Tools

Profiling and Identification of Hop-Derived Bitter Compounds in Beer Using LC-MS/MS

Aromatic Potential of Some Malvasia Grape Varieties Through the Study of Monoterpene Glycosides

Determination of Caffeine in Coffee Products According to DIN 20481

Profiling of Aroma Components in Wine Using a Novel Hybrid GC/MS/MS System

High resolution mass approaches for wine and oenological products analysis

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Rapid Tea Analysis on Poroshell 120 SB-C18 with LC/MS

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

CHAPTER 8. Sample Laboratory Experiments

Figure S1: Fatty acid composition in milk fat from transgenic and control cows.

Fast Analysis of Smoke Taint Compounds in Wine with an Agilent J&W DB-HeavyWax GC Column

Comprehensive analysis of coffee bean extracts by GC GC TOF MS

Somchai Rice 1, Jacek A. Koziel 1, Jennie Savits 2,3, Murlidhar Dharmadhikari 2,3 1 Agricultural and Biosystems Engineering, Iowa State University

Analysis of Pesticides in Wine by LCMS

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

High Sensitivity Quantitation Method of Dicyandiamide and Melamine in Milk Powders by Liquid Chromatography Tandem Mass Spectrometry

Tyler Trent, SVOC Application Specialist; Teledyne Tekmar P a g e 1

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

A novel approach to assess the quality and authenticity of Scotch Whisky based on gas chromatography coupled to high resolution mass spectrometry

Table 1: Experimental conditions for the instrument acquisition method

AppNote 13/2012. Automated Solid Phase Extraction (SPE)-LC-MS/MS Method for the Determination of Acrylamide in Brewed Coffee Samples KEYWORDS ABSTRACT

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

The Determination of Pesticides in Wine

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

Identification of Adulteration or origins of whisky and alcohol with the Electronic Nose

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Cupcake Batter Flavor Concentrate

Pigmented Tannin: Structural Elucidation by a Complimentary Suite of Mass Spectrometric Techniques

One class classification based authentication of peanut oils by fatty

The Good and the Bad Influence of. Polyfunctional Thiols in Beer Hops. Grapefruit or a Cat Box? Application Scientist: Matthew Curtis

ADVANCED BEER AROMA ANALYSIS. Erich Leitner TU Graz, Institute of Analytical Chemistry and Food Chemistry, Graz, Austria

Solid Phase Micro Extraction of Flavor Compounds in Beer

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Clove E-liquid Flavor Concentrate. PO Box 2624 Woodinville, WA 98072

Determination of natamycin in wines Résolution OIV-SCMA

GAS-CHROMATOGRAPHIC ANALYSIS OF SOME VOLATILE CONGENERS IN DIFFERENT TYPES OF STRONG ALCOHOLIC FRUIT SPIRITS

Detecting Melamine Adulteration in Milk Powder

Solid Phase Micro Extraction of Flavor Compounds in Beer

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Speciated Arsenic Analysis in Wine Using HPLC-ICP-QQQ

Uses of profiling trace metals in wine with ICP- MS and Mass Profiler Professional (MPP) for the wine industry

RAPID, SPECIFIC ANALYSIS OF MELAMINE CONTAMINATION IN INFANT FORMULA AND LIQUID MILK BY UPLC/MS/MS

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

16th International CEEPUS Symposium and Summer School on Bioanalysis, Warsaw, Poland, July 06-12, 2016

Analytical Report. Table 1: Target compound levels. Concentration units are ppm or N/D, not detected.

Hongwei Xie, Martin Gilar, Asish Chakraborty, Weibin Chen, and Scott Berger Waters Corporation, Milford, MA, U.S. EXPERIMENTAL

Determination of Metals in Wort and Beer Samples using the Agilent 5110 ICP-OES

Caffeine in Energy Drinks

Supplementary Material

! " # # $% 004/2009. SpeedExtractor E-916

CHAPTER 8. Sample Laboratory Experiments

Analysis of Resveratrol in Wine by HPLC

Supplemental Data. Ginglinger et al. Plant Cell. (2013) /tpc

Quantitative Measurement of Sesquiterpenes in Various Ginger Samples by GC-MS/MS

Fingerprinting Analysis of Different Types of Beer Using Comprehensive 2D-LC

Acidity and ph Analysis

AppNote 4/2003. Fast Analysis of Beverages using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Measuring Sulfur Dioxide: A Perennial Issue. Tom Collins Fosters Wine Estates Americas

VINOLOK (VINOSEAL) closure evaluation Stage 1: Fundamental performance assessment

Organic Chemistry 211 Laboratory Gas Chromatography

TSKgel TECHNICAL INFORMATION SHEET No. 131

AWRI Refrigeration Demand Calculator

Unique Carbohydrate Profiles In Different Brands of Tequila

Case Study: Structure Verification of Quinine Using 1D and 2D NMR Methods

Alcohol Meter for Wine. Alcolyzer Wine

Automation of AOAC for the Identification of FD&C Color Additives in Foods using Solid Phase Extraction

What s New? AlveoLab, SRC-CHOPIN, Mixolab 2. CHOPIN Technologies Geoffroy d Humières

Zoe Grosser, Vinson Leung, Jim Fenster, Brian LaBrecque Horizon Technology, Inc., Salem, NH USA

Higher Resolution Separation of Organic Acids and Common Inorganic Anions in Wine

Elemental Analysis of Yixing Tea Pots by Laser Excited Atomic. Fluorescence of Desorbed Plumes (PLEAF) Bruno Y. Cai * and N.H. Cheung Dec.

Exploratory Wine Study Using SIEVE 2.0. Michael Athanas, Ph.D. VAST SCIENTIFIC

EXTRACTION PROCEDURE

EVOLUTION OF PHENOLIC COMPOUNDS DURING WINEMAKING AND MATURATION UNDER MODIFIED ATMOSPHERE

AppNote 2/2003. Wine Discrimination using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Frontiers in Food Allergy and Allergen Risk Assessment and Management. 19 April 2018, Madrid

Effect of hopping regime, cultivar, and yeast on terpene alcohol content in beer.

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Michigan Grape & Wine Industry Council Annual Report 2012

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

Alcoholic Fermentation in Yeast A Bioengineering Design Challenge 1

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

FTIR Analyzer. Lyza 5000 Wine

Central European Journal of Chemistry

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

Fast Analysis of Arsenic Species in Wines using LC-ICP-QQQ

Bromine Containing Fumigants Determined as Total Inorganic Bromide

3. Aspirin Analysis. Prelaboratory Assignment. 3.1 Introduction

, FAX

Activity 10. Coffee Break. Introduction. Equipment Required. Collecting the Data

The Benefits of GC/MS Coupled with a Headspace Trap to Monitor Volatile Organic Compounds in the Production of Beer

Extraction of Essential Oil from Citrus junos Peel using Supercritical Carbon Dioxide

APPLICATIONS TN Fast and Robust Analysis of Organic Acids from Wine using HPLC-UV. Introduction. Results and Discussion. Materials and Methods

Agilent J&W DB-624 Ultra Inert Capillary Column Screens Distilled Spirits by GC/MS Static Headspace

Transcription:

Application Note Food Testing Identification and Semiquantitation of Monoterpene Glycosides in Ripening Muscat of Alexandria Grapes Application of UHPLC-ESI Accurate-Mass Q-TF LC/MS and MS/MS Authors Andrew Caffrey, Anna Hjelmeland, and Susan E. Ebeler Department of Viticulture and Enology and Food Safety and Measurement Facility, University of California, Davis Jerry Zweigenbaum Agilent Technologies, Inc. Abstract This Application Note presents the workflow and software used to study monoterpene glycosides in Muscat of Alexandria grapes at different stages of ripening. An Agilent 1290 Infinity LC with an Agilent 6530 Accurate-Mass Q-TF LC/MS was used to identify and semiquantitate the abundance of 18 different monoterpene glycosides found in the grapes. The process starts with the creation of a Personal Compound Database Library (PCDL) and the search for potential compounds with untargeted single mass spectrometry. Second, is the generation of fragmentation spectra through auto MS/MS. From the fragments, the correlation and identification of structures are done using Agilent Molecular Structure Correlator (MSC). The process finishes with an update of the PCDL with the found retention times and the creation of an Agilent MassHunter quantitative analysis method that will auto-integrate chromatograms for semiquantitation. This process allows for the identification and semiquantitation of nonvolatile molecules in the absence of chemical standards and without derivatization.

Introduction The original report for this study on monoterpene glycosides can be found in the journal Analytica Chimica Acta 1. Monoterpene glycosides are of interest due to their high relevance in the potential flavor of many grape and wine varieties 1 4. Monoterpenes are plant metabolites that allow the plant to communicate with the surrounding environment to attract or deter specific pests, pollinators, or herbivores 1. The monoterpenes in grapes are largely found in the skin and mesocarp cells 2. High terpene varieties of wine, such as Muscat, Riesling, and Gewurztraminer rely on the flavors of terpenes such as linalool, geraniol, and nerol for their floral characteristics. The glycosides of these compounds serve as reservoirs of terpenic flavor that are slowly released over time during fermentation and storage of the wine 5. Monoterpene glycosides consist of an aglycone monoterpenol bound to a glycone group of one, two, or three sugar residues. Figure 1 displays the general form of a monoterpene glycoside with a single glycosyl residue. The monoterpene glycosides serve as a reserve of potential aroma compounds in wines. The hydrolysis of monoterpene glycosides in grapes and wines may occur because of enzymatic or acid hydrolysis after crushing, during fermentation and wine storage, and within saliva during consumption 3. H 3 C H Figure 1. An example monoterpene glycoside with a single hexose sugar. Traditionally, the analysis of free monoterpenes is accomplished using gas chromatography (GC). Studies primarily use enzymatic or acid hydrolysis to release monoterpenes from the sugars so the glycosides may be measured indirectly as the volatile aglycone 4. These hydrolysis processes are largely effective in freeing the monoterpenes but have limitations. Acid conditions speed up hydrolysis, but cause degradation and rearrangements of the terpenic compounds. Enzyme analysis favors the hydrolysis of specific terpenes over others, and GC methods offer no information on the glycone portion of the glycoside 1,4. In addition, the free monoterpenes need to be analyzed before hydrolysis to distinguish the free volatile fraction from the bound monoterpenes. This study develops a method to measure the glycosides directly. Ultrahigh performance liquid chromatography (UHPLC) paired with electrospray ionization (ESI) is used with accurate mass quadrupole time-of flight mass spectrometry (Q-TF MS) to overcome the limitations of monoterpene glycoside analysis. UHPLC-ESI/Q TF MS provides the appropriate sensitivity and selectivity to identify monoterpene glycosides. However, standards for monoterpene glycosides are largely unavailable. Therefore, tentative identification of compounds is based on predictive databases and structural verification through tandem mass spectrometry (MS/MS). This Application Note outlines the software used for data analysis and quantitation of monoterpene glycosides in grapes. Specifically, these tasks are done using Agilent MSC, Agilent PCDL manager, Agilent MassHunter qualitative analysis, and MassHunter quantitative analysis. Since standards are not available for the terpenic glycosides, an internal standard was used for semiquantitation. The original study used Agilent Profinder for quantitation 1. However, in this report, data analysis has been completed with MassHunter quantitative analysis, and the current quantitation process is outlined within this Application Note. Experimental Instrumentation Monoterpene glycoside extracts were obtained as described in reference 1. These extracts were then analyzed using an Agilent 1290 Infinity UHPLC system coupled to an Agilent 6530 Accurate Mass Q-TF LC/MS with Dual Agilent Jet Stream Electrospray Ionization. The UHPLC system used an Agilent 1290 Infinity binary pump (G4220A), a temperature-controlled Agilent autosampler (G4226A), an Agilent infinity isocratic pump (G1310B), and a temperature-controlled column compartment (G1316C). Table 1 gives the settings and parameters for the UHPLC analysis. Negative polarity Q-TF MS was used for identification and semiquantitation of monoterpene glycosides after separation with UHPLC. Analysis was performed under three separate time segments. During the first and third time segments, before five minutes and after 25 minutes, the LC system diverted the eluent to waste. The eluent was diverted to the Q-TF MS during the second-time segment where mass spectra were obtained for a mass range of m/z 100 to 1,000 at a rate of three spectra/s. Precursor ions with a minimum of 200 counts were selected for auto MS/MS. The MS/MS acquisition mass range was between m/z 50 and 1,000. Table 2 shows the settings used for single MS and MS/MS analysis. 2

Continuous internal calibration was performed during the analysis. The reference masses for the calibration were deprotonated purine (m/z 119.0362) and the acetate adduct of hexakis ( 1 H, 1 H, 3 H-tetraflouropropoxy) phosphazine (m/z 980.016375). Semiquantitation was done using the internal standard decyl β D-glucopyranoside. The internal standard was spiked into each sample before solid phase extraction to account for any variations during sample preparation. Data analysis The identification of the terpenic glycosides began by determining the molecular formulas of potential compounds. The molecular formulas included the mass of a monoterpenol bound to glycosyl residues such as pentose, hexose, or deoxyhexose sugars. Each combination of the glycosyl sugars was considered for the various disaccharides or trisaccharides as well. From there, the molecular formulas were added and named as compounds within the PCDL Manager. The PCDL Manager then automatically generated the exact mass of each compound based on the molecular formula. Alternatively, both the formula and the exact mass may be derived from a chemical structure if it is added to the Personal Compound Database (PCD) as a mol file. The structures may be obtained from online sources such as Chemspider, or drawn through various molecular structure programs such as Chemdraw and Chemsketch. The database created was then saved and applied to an obtained LC/MS chromatogram within MassHunter qualitative analysis software, find by formula algorithm. To tentatively determine the compounds present in the chromatogram, each hit from the database search was then analyzed for mass accuracy, isotope spacing, and relative abundance. Table 1. UHPLC parameters. Parameter Instrument Mobile phase Gradient Flow rate Column Temperature 40 C Injection volume 10 µl Agilent 1290 Infinity Binary LC A) 0.1 % acetic acid in water B) 0.1 % acetic acid in acetonitrile Linear Time (min) %B 0 5 5 20 5 18 Hold 20 18 22 20 to 90 22 25 90 to 5 25 28 Hold 5 0.420 ml/min Table 2. Q-TF LC/MS parameters. Instrument Parameter Ionization mode Single MS acquisition rate Single mass range MS1 acquisition rate MS2 acquisition rate Precursor per MS1 spectrum 3 Active exclusion Collision energy Value Agilent InfinityLab Poroshell 120 Phenyl Hexyl, 2.1 150 mm, 2.7 µm, LC column (p/n 693775 912) with an Agilent InfinityLab Poroshell 120 Phenyl-Hexyl 2.1 5 mm, 2.7 µm Guard Column (p/n 821725-914) Value 6530 accurate-mass Q-TF LC/MS Negative electrospray with Dual Agilent Jet Stream Technology 3.0 spectra/s 100 to 1,700 m/z 3.00 spectra/s 4.00 spectra/s n 20.00 ev Drying gas temperature 150 C Drying gas flow rate 10 L/min Sheath gas temperature 350 C Sheath gas flow rate Nebulizer gas Skimmer voltage ctopole RF Fragmentor Capillary 11 L/min 35 psi 65 V 750 V 120 V 3.5 kv 3

Hits found with a mass of ±10 ppm difference to the target exact mass were exported from qualitative analysis as an auto MS/MS preferred list. Auto MS/MS was then performed to generate fragmentation spectra that were used for structure matching and compound identification. In accordance with the structure found in the PCD, auto MS/MS spectra were exported into MassHunter MSC where they were analyzed to generate molecular fragment structures. Figure 2 shows an example of generated fragments. In addition, Figure 2 shows the auto MS/MS spectrum used to generate the structures in MassHunter MSC. To determine the likelihood of the compound being an analyte of interest, each auto MS/MS spectrum was analyzed within MassHunter MSC. If the compound was verified with fragments and putatively identified, the PCDL Manager was updated with its respective retention time and MS/MS spectra. 10 2 9 8 A 161.04550 Counts 7 6 5 71.01321 101.02299 131.03581 315.18039 4 3 2 1 0 285.03554 447.20661 187.29887 228.56527 355.62914 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 Mass-to-charge (m/z) B Mass: 448.2315 Da m/z 315.1818 m/z 161.0455 m/z 89.025 H 3 C H 3 C H 3 C H 3 C Figure 2. A) An Auto MS/MS spectrum of a monoterpene hexose pentose. B) Potential fragment structures and proposed structure generated through MSC based on the spectrum in A. Each fragment ion is shown with the corresponding m/z found in A. Fragmentation losses through collision-induced dissociation are shown in grey. 4

MassHunter quantitative analysis software was implemented for semiquantitative analysis. To set up a method in the quantitative analysis software, a single MS data file was loaded into qualitative analysis. Compound peaks were identified within the data file by searching for compounds using the PCDL, as described previously. The same data were loaded into quantitative analysis, and a new method was created to analyze the remaining data files. Figure 3 shows the process of adding a compound. Quantitative analysis outlier setup was used to help with the data analysis process by identifying when the integrator found a peak outside of the retention time window ±0.5 minutes, or if the peak was integrated with a signal to noise ratio (S/N) of less than three. User-uploaded structure to generate a formula and exact mass Compound information updated with found retention times Figure 3. MassHunter PCDL manager was used to create a custom library to search for potential monoterpene glycosides in an untargeted MS study. nce compounds were identified, the database and library were updated with the respective retention times and MS/MS spectra. 5

Noise regions for each compound were manually determined for the S/N. Figure 4 displays the auto-integration of the extracted ion chromatograms along with the method used for the integrations. To calculate peak intensities relative to the internal standard, integrations were then exported from quantitative analysis into Microsoft Excel where the values were analyzed further. R Foundation for Statistical Computing, 2011 (R) was used to perform a one-way analysis of variance (ANVA) followed by student s t-tests to determine statistical significance between ripening stages based on an α of 0.05. Compound information for integration Auto-integration preview with its extracted mass spectra Figure 4A. Compounds from the PCDL were input into MassHunter quantitative analysis for an auto-integration method. Each compound was given a name, retention time, noise region, and m/z ratio(s). A representative spectrum was used to ensure that the software finds the correct peaks with the given parameters. 6

Retention time outliers are highlighted for easy viewing Warnings are displayed if the S/N ration falls below a set value of 3.00 Auto-integrated EIC spectrum with options for manual integration Figure 4B. MassHunter quantitative analysis auto-integrated each spectrum based on the method used. The software displays the peak area, retention time, and S/N. Cells that are outliers for retention time and S/N are highlighted in blue. 7

Results and discussion A representative extracted ion chromatogram of monoterpene glycosides in Muscat of Alexandria grapes was generated from the data in qualitative analysis, and is shown in Figure 5. The compounds were found through a find-by-formula search using the generated PCDL. Table 3 shows the possible monoterpene glycosides along with their retention time, formula, expected and observed m/z values, and mass errors. The compounds were identified through an auto MS/MS analysis. The collision induced dissociation of monoterpene glycosides produced various charged fragments depending on the number of sugars in the glycone. The identification of a compound through MS/MS depends on the presence of glycone fragments along with the pseudomolecular ion. Monoterpenes were not identifiable as fragments since they were a neutral loss during dissociation. Figure 2 displays the MSC-generated structures from an MS/MS spectrum of a monoterpenol hexose pentose. MSC displays the pseudomolecular ion (m/z 447.2236) and fragments of the molecule. MSC outlines the loss of a pentose sugar (m/z 315.1381), a hexose (m/z 161.0472), and ring fragments characteristic of sugars (m/z 59.0139, 71.0139, 89.0244, 101.0244, and 113.0244). The identification process was repeated, giving the list of compounds in Table 3. 10 5 6.0 5.6 5.2 5 9 14 4.8 4.4 4.0 3.6 11 12 Counts 3.2 2.8 2.4 10 2.0 1.6 3 13 16 18 1.2 0.8 7 15 17 0.4 0 2 4 8 1 6 9 10 11 12 13 14 15 16 17 18 Acquisition time (min) IS 19 20 21 Figure 5. An extracted ion chromatogram of monoterpene glycosides found by searching with the custom PCDL library. Peak numbers correspond to the monoterpene glycosides in Table 3. 8

Table 3. Identified monoterpene glycosides with their corresponding retention times, masses, and mass errors. Glycoside RT (min) Compound Formula Predicted m/z bserved m/z Mass error (ppm) 1 9.76 Monoterpenol dihexose pentose 1 C 27 H 46 15 609.27639 609.27603 0.59 2 9.95 Monoterpenol hexose pentose 1 C 21 10 447.22357 447.22326 0.69 3 11.18 Monoterpenol hexose pentose 2 C 21 10 447.22357 447.22330 0.60 4 11.19 Monoterpenol glucoside 1 C 16 H 28 6 315.18131 315.18118 0.41 5 12.25 Monoterpenol hexose pentose 3 C 21 10 447.22357 447.22389 0.72 6 12.27 Monoterpenol glucoside 2 C 16 H 28 6 315.18131 315.18112 0.60 7 12.57 Monoterpenol glucoside 3 C 16 H 28 6 315.18131 315.18141 0.32 8 12.59 Monoterpenol hexose deoxyhexose 1 C 22 H 38 10 461.23922 461.23917 0.11 9 13.82 Monoterpenol hexose pentose 4 C 21 10 447.22357 447.22362 0.11 10 14.02 Malonylated monoterpenol glucoside 1 C 21 H 34 11 461.20284 461.20262 0.48 11 14.07 Monoterpenol hexose pentose 5 C 21 10 447.22357 447.22376 0.42 12 14.77 Malonylated monoterpenol glucoside 2 C 21 H 34 11 461.20284 461.20341 1.24 13 14.87 Monoterpenol hexose pentose 6 C 21 10 447.22357 447.22347 0.22 14 15.27 Monoterpenol hexose pentose 7 C 21 10 447.22357 447.22398 0.92 15 15.46 Malonylated monoterpenol glucoside 3 C 21 H 34 11 461.20284 461.20321 0.80 16 15.9 Monoterpenol hexose pentose 8 C 21 10 447.22357 447.22356 0.02 17 16.02 Monoterpenol hexose deoxyhexose 2 C 22 H 38 10 461.23922 461.23822 2.17 18 16.42 Malonylated monoterpenol glucoside 4 C 21 H 34 11 461.20284 461.20274 0.22 I.S. 21.03 Decyl-Beta-D- Glucopyranoside C 16 H 32 6 319.21261 319.2127 --0.28 MassHunter quantitative analysis was used for the semiquantitation of each identified compound over the grape ripening process. The software autogenerates an extracted ion chromatogram for each compound and integrates peaks based on their compliance to measured retention times and S/Ns. Relative values for each glycoside are generated by comparing the peak areas of each compound to the peak area of the internal standard, decyl β D glucopyranoside. Muscat of Alexandria grapes harvested at commercial maturity were found to have the highest abundance and diversity of monoterpenol glycosides compared to earlier maturation time points. f the 18 identified compounds, 15 showed a statistically significant increase in relative abundance after the onset of ripening. This increase indicates that the ripening stage of fruit development is crucial for the development of monoterpenes and their respective glycosides 1. Conclusion Grape monoterpene glycosides were identified and semiquantitated, giving relative concentrations at three ripening stages through accurate mass UHPLC Q TF MS. A workflow was developed by building a database of potential monoterpene glycosides with possible structures in the PCDL Manager. Untargeted searches of Muscat of Alexandria grape samples were done through the MassHunter qualitative analysis find-by-formula algorithm using the custom PCDL. nce potential matches were found, auto MS/MS studies were performed to generate fragmentation spectra for structure elucidation and identification in MSC. After identification of the structures, a custom quantitative analysis method was created to auto-integrate peaks based on the ions present and retention times. Peak integrations were then related to the internal standard to determine the relative amounts of each of the 18 glycosides in the grapes at various growth stages. For most of the compounds, the key event for their accumulation is the onset of ripening. This is possibly due to an increase in synthesis and storage within the grape. 9

References 1. Hjelmeland, A.; Zweigenbaum, J.; Ebeler, S. E. Profiling Monoterpenol Glycoconjugation in Vitis vinifera L. cv. Muscat of Alexandria using Novel Compound Database Approach, High Resolution Mass Spectrometry and Collision Induced Dissociation Fragmentation Analysis. Analytica Chimica Acta 2015, 887, 138 147. 2. Flamini, R.; et al. Profiling of Grape Monoterpene Glycosides (Aroma Precursors) by Ultra High Performance Liquid Chromatography-High Resolution Mass Spectrometry (UHPLC/QTF). Journal of Mass Spectrometry 2014, 49, 1214 1222. 3. Parker, M.; et al. The Contribution of Wine Derived Monoterpene Glycosides to Retronasal dour During Tasting. Food Chemistry 2017, 232, 413 424 4. Dziadas, A.; Jelen, H. Comparison of Enzymatic and Acid Hydrolysis of Bound Flavor Compounds in Model Systems and Grapes. Food Chemistry 2016, 190, 412 418. 5. Wilson, B.; Strauss, C. R.; Williams, P. J. The Distribution of Free and Glycosidically-Bound Monoterpenes Among Skin, Juice, and Pulp Fractions of Some White Grape Varieties. American Journal Enololgy and Viticulture 1986, 37, 107 111. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc. 2018 Printed in the USA, August 16, 2018 5991-9448EN