Table 1: Experimental conditions for the instrument acquisition method

Similar documents
Solid Phase Micro Extraction of Flavor Compounds in Beer

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

Somchai Rice 1, Jacek A. Koziel 1, Jennie Savits 2,3, Murlidhar Dharmadhikari 2,3 1 Agricultural and Biosystems Engineering, Iowa State University

Profiling of Aroma Components in Wine Using a Novel Hybrid GC/MS/MS System

Tyler Trent, SVOC Application Specialist; Teledyne Tekmar P a g e 1

Solid Phase Micro Extraction of Flavor Compounds in Beer

CHAPTER 8. Sample Laboratory Experiments

CHAPTER 8. Sample Laboratory Experiments

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Clove E-liquid Flavor Concentrate. PO Box 2624 Woodinville, WA 98072

Analytical Report. Volatile Organic Compounds Profile by GC-MS in Cupcake Batter Flavor Concentrate

ADVANCED BEER AROMA ANALYSIS. Erich Leitner TU Graz, Institute of Analytical Chemistry and Food Chemistry, Graz, Austria

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

Analytical Report. Table 1: Target compound levels. Concentration units are ppm or N/D, not detected.

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

Agilent J&W DB-624 Ultra Inert Capillary Column Screens Distilled Spirits by GC/MS Static Headspace

Identification of Adulteration or origins of whisky and alcohol with the Electronic Nose

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

One class classification based authentication of peanut oils by fatty

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

GAS-CHROMATOGRAPHIC ANALYSIS OF SOME VOLATILE CONGENERS IN DIFFERENT TYPES OF STRONG ALCOHOLIC FRUIT SPIRITS

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Comprehensive analysis of coffee bean extracts by GC GC TOF MS

Fast Analysis of Smoke Taint Compounds in Wine with an Agilent J&W DB-HeavyWax GC Column

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Emerging Applications

The recent introduction of flavored wine and malt beverages

Analysis of Volatile Compounds of Jasminum nitidum [Acc.JN.1] Flowers

SUPELCO. Analysis of Flavors and Off-Flavors in Foods and Beverages Using SPME. Robert E. Shirey and Leonard M. Sidisky

Life Science and Chemical Analysis Solutions. Key Words: GCxGC-TOFMS, SPME, Food and Flavors. LECO Corporation; Saint Joseph, Michigan USA

AppNote 4/2003. Fast Analysis of Beverages using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

The Benefits of GC/MS Coupled with a Headspace Trap to Monitor Volatile Organic Compounds in the Production of Beer

Bromine Containing Fumigants Determined as Total Inorganic Bromide

TSKgel TECHNICAL INFORMATION SHEET No. 131

AppNote 2/2003. Wine Discrimination using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Project Summary. Principal Investigator: C. R. Kerth Texas A&M University

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

Investigating the factors influencing hop aroma in beer

Volatile Profiling in Wine Using Gas Chromatography Mass Spectrometry with Thermal Desorption

Research Article Analysis of Volatile Flavor Compounds of Jujube Brandy by GC-MS and GC-O Combined with SPME

Analysis of volatile compounds in beer of extruded rice as adjunct by headspace sampling-gas chromatography

High Sensitivity Quantitation Method of Dicyandiamide and Melamine in Milk Powders by Liquid Chromatography Tandem Mass Spectrometry

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Inhibition of the Decrease of Volatile Esters and Terpenes During Storage of Wines and a Model Wine Medium by Wine Phenolic Extracts

Experiment 6 Thin-Layer Chromatography (TLC)

Determination of Volatile Compounds in Romanian White Wines by Headspace Solid-phase Micro-extraction and Gas Chromatography Mass Spectrometry

Analysis of Volatile Compounds from the Concrete of Jasminum multiflorum Flowers

Characterisation of New Zealand hop character and the impact of yeast strain on hop derived compounds in beer

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

The Determination of Pesticides in Wine

! " # # $% 004/2009. SpeedExtractor E-916

by trained human panelist. Details for each signal are given in Table 2.

The Good and the Bad Influence of. Polyfunctional Thiols in Beer Hops. Grapefruit or a Cat Box? Application Scientist: Matthew Curtis

Occurrence of furan in commercial samples of roasted coffee in Brazil

Quantitative Measurement of Sesquiterpenes in Various Ginger Samples by GC-MS/MS

GC/MS BATCH NUMBER: W10104

General overview of the two stages of the QuEChERS technique. Stage 1: Sample extraction. Stage 2: Sample cleanup

A novel approach to assess the quality and authenticity of Scotch Whisky based on gas chromatography coupled to high resolution mass spectrometry

EXTRACTION PROCEDURE

Determination of Caffeine in Coffee Products According to DIN 20481

Protective Effect of Thiols on Wine Aroma Volatiles

Factors influencing mandarin fruit quality. What drives the eating. Outline. experience in mandarins?

Rapid Tea Analysis on Poroshell 120 SB-C18 with LC/MS

Determination of key volatiles in Australian Black Truffles aroma by combined GCMS and organoleptic techniques

Novel Closed System Extraction of Essential Oil: Impact on Yield and Physical Characterization

Zoe Grosser, Vinson Leung, Jim Fenster, Brian LaBrecque Horizon Technology, Inc., Salem, NH USA

Determination of Volatile Aroma Compounds of Blaufrankisch Wines Extracted by Solid-Phase Microextraction

PECTINASE Product Code: P129

Beyond TPH. John Fitzgerald Massachusetts Department of Environmental Protection

Higher Resolution Separation of Organic Acids and Common Inorganic Anions in Wine

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Het NIZO micro dinner:

Application Note CL0311. Introduction

Separations. Objective. Background. Date Lab Time Name

Smoke Taint Update. Thomas Collins, PhD Washington State University

Petite Mutations and their Impact of Beer Flavours. Maria Josey and Alex Speers ICBD, Heriot Watt University IBD Asia Pacific Meeting March 2016

AppNote 6/2013. Using TDU-Pyrolysis-GC-MS to Investigate Aged Whiskey Samples and Their Oak Barrels ABSTRACT INTRODUCTION

VINOLOK (VINOSEAL) closure evaluation Stage 1: Fundamental performance assessment

Volatiles: Impacts of Fruit Development, Ethylene, and Storage Environment. Jim Mattheis Tree Fruit Research Laboratory Wenatchee, WA, USA

Introduction. Experimental. : : APPLICATION NOTE SP024: Pesticide Anaylsis: Standard QuEChERS vs Modified Method. : : APPARATUS: Geno/Grinder

Application Note FP High Sensitivity Coumarin Analysis. Introduction. Keywords

Improved Cleanup of Pesticides in Dry, Difficult Matrices Using a Novel Dual-Layer SPE Cartridge for LC/MS/MS and GC/MS/MS Analysis

High resolution mass approaches for wine and oenological products analysis

MILK ADULTERATION. By, Gautami Shirsat Grisha Dialani Sushmita Suman

A COMPARATIVE STUDY OF THE CAFFEINE PROFILE OF MATURE TEA LEAVES AND PROCESSED TEA MARKETED IN SONITPUR DISTRICT OF ASSAM, INDIA.

AppNote 1/2003. Fast Analysis of Food and Beverage Products using a Mass Spectrometry Based Chemical Sensor KEYWORDS ABSTRACT

Unique Carbohydrate Profiles In Different Brands of Tequila

The Headspace Volatiles Generated at the Initial Stage of Spoilage in the Aerobically and Vacuum Packed Beef, Pork

Organic Chemistry 211 Laboratory Gas Chromatography

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

GC/MS BATCH NUMBER: TL0103

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

STUDIES ON THE ANALYTICAL CHARACTERISTICS OF WINES OBTAINED FROM VINE VARIETY WITH BIOLOGICAL RESISTANT

three different household steam ovens, representing a number of identically constructed ovens (see attached list at the end of this document):

Seedling VOCs induce host preference in Bagrada hilaris Burmeister Mokhtar Abdulsattar Arif

Michigan Grape & Wine Industry Council Annual Report 2012

, FAX

Volatile Compounds Profile during Storage of Ionathan, Starkrimson and Golden Delicious Apple Varieties

Transcription:

PO-CON1702E The Comparison of HS-SPME and SPME Arrow Sampling Techniques Utilized to Characterize Volatiles in the Headspace of Wine over an Extended Period of Time Pittcon 2017 1430-11P Alan Owens, Michelle Yang, Nicole Lock, Andy Sandy, Shimadzu Scientific Instruments, Columbia, MD, USA

Introduction Increased production of wine in a multitude of regions has led to increased competition as well as an upsurge in demand for quality control. Improving grape-quality and identifying overall compounds that are a direct result of grape quality give wine producers a competitive edge in flavor and aroma control. The quality of wine can be measured by flavor/aroma components making the characterization of the volatiles responsible for these constituents an indispensable task. The volatiles documented ranged from alcohols to molecules like fatty acids and esters1. In order to efficiently analyze these volatiles, analysis was performed by GCMS via two sampling methods: headspace solid phase micro extraction (HS-SPME) and SPME Arrow. Both HS-SPME and SPME Arrow samples were collected over a period of time, analyzing the degradation or disappearance of flavor/aroma volatiles in the headspace of wine. In this study, a comparison between the two sampling techniques and their overall ability to extract volatiles from the headspace of wine over a four month period was reported. It was determined that the SPME Arrow2, which can be seen in figure 1 below, proved to be the more effective technique. The sensitivity of the sampling method allowed for more volatile characterization as well as volatile identification over time. This information will give wine producers new insight to how both flavor and aroma are affected by the ever changing headspace of wine. Figure 1: Sorption phase size comparison between classical SPME fiber and PAL SPME Arrow. The original SPME fiber boasts a 100-μm 10-mm, 0.6-μL sorption phase, whereas the PAL SPME Arrow has a 250-μm 30-mm, 15.3-μL sorption phase for the 1.5mm diameter model. A 1.1mm diameter is available. The new SPME Arrow (CTC Analytics) has revolutionized the microextraction sampling technique. The SPME Arrow outlasts the classical SPME fiber with a mechanical robustness that leads to a 2x longer lifetime as well as in increase in sensitivity up to 10x than the original PSME fiber. The design of the SPME Arrow protects the sorptive material minimizing outside factors that could potentially result in loss of analytes. 2

Experimental A bottle of Moscato was obtained for the SPME analysis of volatiles in the headspace. Seven milliliter aliquots of the Moscato were transferred to standard 20 ml crimp top vials. The samples were then spiked with 1.5g of sodium chloride to increase ionic strength of the samples, consequently forcing more volatiles into the headspace. The original silicon septa were replace with red high temperature septa to drastically reduce and even eliminate bleed. The two SPME Techniques were both tested utilizing a standard Rxi-5 MS (30m x 0.25mm x 0.25um) column to specifically search for more volatile compounds. The traditional SPME Method was run initially in August when the wine was fresh and unopened. The headspace of the wine was then analyzed again four months later utilizing traditional SPME and SPME Arrow. Qualitative analysis was performed to identify the number of VOCs recovered as well as to compare the relative intensities of the compounds peaks. Table 1 shows the experimental conditions for the GC-MS as well as the autosampler (AOC-6000). Table 1: Experimental conditions for the instrument acquisition method SPME Method : AOC-6000 Fiber : DVB/CAR/PDMS 23ga. Supelco Fiber Sample Prep (Incubation/Agitation) : 40 C 20 minutes 500 rpm Sample Extraction : 40 C 40 minutes Sample Desorption : 260 C 3 minutes Post Conditioning : 260 C 2 minutes Gas Chromatogram : GC-2010 Plus Injection : Splitless Injection at 260 C 1 minute sampling time Column : Rxi-5 MS 30.0m x 0.25 mm x 0.25 μm Helium carrier gas Constant linear velocity, 36.1 cm/sec Column Flow 1.00 ml/min Purge Flow 3.0 ml/min Oven Program : 40 C, hold 2.0 min 3 C /min to 250 C, hold 15.0 min Total GC run time 87.00 min Detector : GCMS-QP2020 Operating mode : SCAN Ion Source : 200 C, EI mode, 70eV Interface Temp : 250 C Solvent Cut Time : 2 min Start Time End Time (min) : 2.5 87.00 Event Time : 0.200 sec Start m/z End m/z : 50.00 350.00 3

Results and Discussion In figure 2, the chromatogram for the traditional SPME acquisition of the headspace of the newly opened wine. Overall 48 peaks were detected. Figure 2: TIC of Moscato using traditional SPME Figure 3 Shows the chromatogram of the Moscato after a four month period, which was acquired by the standard SPME Method. Overall, 26 peaks were detected ranging from alcohols to fatty acids. Figure 3: TIC of Moscato after 4 months utilizing traditional SPME 4

Figure 4 shows the chromatogram recorded utilizing the SPME Arrow. This data was acquired after a four month period as well. All qualitative and quantitative parameters were kept consistent throughout the three runs. Overall, 25 peaks were detected. Figure 4: TIC of Moscato after 4 months utilizing SPME Arrow A list of the major compounds that were found in the headspace of wine was compiled to compare area counts. Not all compounds were selected, only the major components that we expected to see. The table with the components and their respective area counts can be seen below. 5

Table 2: List of major components found in the headspace of wine and their respective area counts Compound Name SPME SPME after 4months SPME Arrow after 4 months 1-Pentanol 109505892 97954731 69586324 Butanoic acid, ethyl ester 1661914 3327537 15556171 3-Furaldehyde 2602589 19175005 Butanoic acid, 2-methyl-, ethyl ester 459608 4498357 Butanoic acid, 3-methyl-, ethyl ester 481065 23535537 8992544 1-Hexanol 4981709 18040944 1-Butanol, 3-methyl-, acetate 32792834 98554627 3-Oxatricyclo[4.1.1.0(2,4)]octane, 2,7,7-trimethyl- 571183 2051940 8113552 2H-Pyran, 2-ethenyltetrahydro-2,6,6-trimethyl- 1171544 5104035 16508930 Hexanoic acid, ethyl ester 25979767 66126904 104326013 Acetic acid, hexyl ester 12118128 5923500 19160101 D-Limonene 2116078 Phenylethyl Alcohol 147118189 234855296 3366222 Octanoic acid, ethyl ester 44005522 164438395 188048185 Octanoic acid 4483080 2397269 Geranyl ethyl ether 1 1212001 1589674 6753665 Naphthalene, 1,2-dihydro-1,1,6-trimethyl- 1597961 2330652 Dodecanoic acid 63116778 2795102 118257597 Ethyl tridecanoate 9303435 58279582 Summary and Conclusions Overall both techniques were extremely effective at identifying volatile organic compound. The saturated wine samples contained ample VOCs in the headspace even after four months of being opened. The SPME Arrow method was a much more sensitive method recovering almost twice as many VOCs as well as some additional compounds not found on the list. However, with this sensitivity, the SPME Arrow method is more susceptible to column bleed as well as phthalates from septum bleed. Due to its increased sensitivity, the SPME Arrow can be used for applications where low detection limits are necessary, but it could also be used for applications with long sample prep periods. The increased size of the stationary would allow the Arrow fiber to produce the same sensitivity as the traditional fiber in less time. 6

References 1. Khio, S.-W.; Cheong, M.-W.; Zhou, W.; Curran, P.; Yu, B. Characterization of thevolatility of Flavor Compounds in Alcoholic Beverages through Headspace Solid-Phase Microextraction (HS-SPME) and Mathematical Modeling. Journal of Food Science 2011, 77 (1), C61 C70. 2. Kremser, A., Jochmann, M.A. & Schmidt, T.C. Anal Bioanal Chem (2016) 408: 943. doi:10.1007/s00216-015-9187-z First Edition: March, 2017 Shimadzu Corporation, 2017