Product Data. 38CMC (60 Hz) 11 SEER Air Conditioner. Sizes 018 thru 060

Similar documents
Model 593C 10 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 593C.18.9

Product Data. 38TUA (60 Hz) Air Conditioner. Quality Assurance. Sizes 018 thru 060 FEATURES/BENEFITS

EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Min. Circuit Ampacity. Max. Fuse or Breaker

Product Data. 24ABB3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S S

Product Data. Efficiency. S SEER/ EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Max. Fuse or Breaker. Shipping/Operating Weight lbs.(kg) R4H318AKA 1 1/2 18, /16 x 23 1/8 x 23 1/8 131 / 117 (59 / 53)

Product Data. Efficiency

FORM NO. ATZ-221 Supersedes Form No. ATZ-210 AIR CONDITIONERS

EFFICIENT 13 SEER 3 -PHASE AIR CONDITIONER. Min. Circuit Ampacity

AIR CONDITIONERS WA13 SERIES

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

MAINLINE AIR CONDITIONERS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

TECHNICAL SUPPORT MANUAL Split System Air Conditioner (C,H,T)4A3

TECHNICAL SUPPORT MANUAL Split System Air Conditioner R2A3

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

13 SEER CONDENSING UNITS

MODEL: SA14. Air Conditioners. Sure Comfort SA14. Air Conditioners

Ruud Achiever Series Air Conditioners

T CLASS SPLIT SYSTEM UNITS High Efficiency - R-410A - 60 HZ

TECHNICAL SUPPORT MANUAL Ducted Horizontal Air Conditioner HC4A3

Ruud Achiever Series Air Conditioners

Ruud Achiever Series Air Conditioners

Ruud Achiever Series Air Conditioners

Rheem Classic Series. Air Conditioners

A951A/S PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Rheem Classic Series. Air Conditioners

ENZX. EBARA Submersible Slurry Pump. Contents Project: Model: Chk d: Date:

TECHNICAL SUPPORT MANUAL Split System Heat Pump N4H3

Rheem Classic Series. Air Conditioners

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Reciprocating Compressor Models. Rotary Compressor Models CONTENTS

Downflow Conversion Kit used to Modify Air Handler Units for Downflow Application

Ruud Achiever Series Air Conditioners

4PXC. Cased Aluminum Dedicated Upflow / Downflow Coils Convertible to Horizontal with Kit PUB. NO

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A3

POWERED BY NITRO COLD BREW COFFEE FULL EQUIPMENT LINE

PARTS CATALOG ESPRESSO EP SYSTEM

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

CMC DUO. Standard version. Table of contens

E N T E R P R I S E S

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

SECTION MANUFACTURED GAS FIREPLACES

2<

Pneumatic Cylinders Cartridge Cylinders Series P1G

Parts Catalog Espresso System

E N T E R P R I S E S

INSTALLATION AND WARRANTY CERTIFICATE. Machine model Serial Number # Rating and optional. Installation Company: Technician ID: Date: / /

BUILT IN DELUXE SPIT BRAAI MODELS: 1200 & 1500

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

ACME Fluid Systems. Strainer Selection Guidelines Web:

Cutout Width 28 5/8 28 5/8 40 1/4 40 1/4 (72.7 cm) (72.7 cm) (102.2 cm) (102.2 cm)

NORTH / 1KG. Mill City Roasters, LLC rd Ave SE Minneapolis, MN 55414

Powder Booths GLOBAL FINISHING SOLUTIONS GLOBALFINISHING.COM GLOBAL FINISHING SOLUTIONS

Award winning winemaker Teusner Wines recently invested in two Kaeser SK 25

alfresco enjoy the experience

NORTH / 2KG. Mill City Roasters, LLC rd Ave SE Minneapolis, MN 55414

Surface-Mounted Thermostat ATH series

TRUSTED RELIABLE QUALITY

TEA CATER USER MANUAL. UM_EN Part No.:

OWNER S MANUAL GRAVITY FEED MODELS FOR OUTDOOR USE ONLY WARNING DO NOT STORE OR USE COMBUSTIBLE MATERIALS NEAR THIS UNIT

POWERED BY COLD BREW NITRO COFFEE FULL EQUIPMENT LINE

TRUSTED RELIABLE QUALITY

The Design and Marketing of a 300 Kilogram Coffee Roaster

NOTICE TO INSTALLER: Please leave this book with the machine. Table of Contents

ZANOLLI. Pizza ovens. Spare parts for: Suitable for:

INSTALLATION AND OPERATION MANUAL FOR GAS TILTING BRAISING PANS MODELS G30TB & G40TB

Shotmeister Owner s Manual. The Sleekest Design, Pouring the Coldest Shots

94306 Vertical Flame Arrester. Features. Vertical Flame Arrester. Unitized tube bank design

NEPTUNE consisting of: Roasting machine body - Roasting drum with feeding device and hinged drum lid for emptying of the machine - Roaster fan

Upflow Carbon Installation & Start-Up Guide

SERVICE MANUAL ESPRESSO COFFEE BREWER UNITS

Vent-Free. Fireboxes. LogMate Vent-Free Gas Fireboxes Indoor / Outdoor. Premium Luxury Series. Performance Traditional Series

Wega Mininova 2003 Installation Instructions

REVERSIBLE DOOR 1. LAMP SWITCH 2. CABINET 3. LEVELLING LEGS 4. WINE RACK 5. GLASS DOOR 6. CHROME SHELVES 7. INTERIOR LAMP 8.

Oven-quality food, fast!

Installation & Parts Manual 2" & 3" High Capacity Strainers For Class 1, Petroleum Applications

Eaton Filtration, LLC

ATTIAS OVEN CORPORATION (COMMERCIAL BBQ ROTISSERIES)

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

THE GR THER A AINF AINF A THER THE GR

Eaton Filtration, LLC

Matic / THa. Operating instructions COFFEE BREWER. Mode d emploi MACHINE À CAFÉ. Gebrauchsanleitung KAFFEEBRÜHMASCHINE

12 Bottle Dual Zone. Touchscreen INSTRUCTION MANUAL

Pellet Pro 12 & 18 Lengths Large 35lb Hopper Assembly Operation Manual

MINI LABROLLER ROTATOR

Product Presentation. C-series Rack Ovens

18-Bottle Dual Zone Slimline Edition Touchscreen Refrigerator

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

Special Lucalox. GE Lighting DATA SHEET. Description

THE COBURN COMPANY, INC. PO Box 147 Whitewater, WI U.S.A. Phone: Fax:

Proposed Addendum be to Standard , Energy Standard for Buildings Except Low-Rise Residential Buildings

USER MANUAL SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS SSSSSSSSSSSS BSC01

Chicken Rotisserie. Model LM-8A LM-12A LM-8M LM-12M Instruction Manual

WILBUR CURTIS COMPANY, INC.

+ = Power up your Smart Cup while pressing the corresponding button to reach different program modes. Heat Exchange fill/tank Drain Page:

CPF48UGMYW New product

WILBUR CURTIS COMPANY, INC. ThermoPro Single Head Brewer Instructions

BLG-E ELECTRIC FLOOR MODEL BRAISING PAN WITH MANUAL GEARBOX TILT INSTALLATION OPERATION MAINTENANCE

Transcription:

Product Data 38CMC (60 Hz) 11 SEER Air Conditioner Sizes 018 thru 060 The model 38CMC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today, including SEER ratings up to 12.8 when used with components as designated by manufacturer. All models are listed with UL (U.S. and Canada), ARI, and CEC. AVAILABLE OPTIONS Electrical Range All units are offered in 208 230v single phase. Wide Range of Sizes Available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. Compressor Each compressor is mounted on rubber isolators for additional sound reduction. For improved serviceability, the 018 through 042 models are equipped with a compressor terminal plug. Continuous operation is approved down to 55 F (12.8 C) in the cooling mode. Operation down to 0 F or 20 F is approved when low-ambient requirements are followed. (See cooling performance tables.) WeatherArmor Cabinet Steel is protected with a galvanized coating and treated with a layer of zinc phosphate. A coat of modified polyester powder is then applied and baked on providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rust-resistant, quality appearance. Copyright 2004 Carrier Corporation Form 38CMC-5PD

ly Enclosed Fan Motor Means greater reliability under rain conditions and dependable performance for many years. Permanent-split-capacitor-type motors provide more economical operation. Unit Design Copper tube, enhanced sine wave aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style drain pan for easy removal of water, dirt, and leaves. Application Versatility The 38CMC can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. Unit can be installed on a roof or at ground level. External Service Valves Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. Easy Serviceability One access panel provides access to electrical controls. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil and compressor. Limited Warranty Standard 5-year limited warranty on all parts 5-year limited warranty on the compressor. UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. REGISTERED QUALITY SYSTEM. Model number nomenclature 38CMC 018 3 1 1 Standard 11 SEER Split-tem Air Conditioner Nominal 018 18,000 Btuh 042 42,000 Btuh 024 24,000 Btuh 048 48,000 Btuh 030 30,000 Btuh 060 60,000 Btuh 036 36,000 Btuh Electrical 3 208-230 1 Series Packaging A-weighted sound power (dba) UNIT STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone penalty) SIZE RATING 125 250 500 1000 2000 4000 8000 018 31 80 56.0 61.5 64.0 67.5 69.0 66.5.0 024 31 80 54.0 57.5 60.5 66.0 69.0 68.0 65.5 030 31 82 53.5.5 67.0 70.0 70.5 71.0 66.5 036 32 82 58.5 67.5 71.5 75.0 76.0 73.0 68.0 042 32 82 56.5 67.0 72.0 78.5 75.0 69.0 65.0 048 30 82 56.0 70.5 72.0 75.0 71.0 68.5 61.5 060 30 82 54.5 65.5 69.0 73.0 68.5 69.0.5 NOTE: Tested in accordance with ARI 270.95. (Not listed with ARI.) 2

Physical data UNIT SIZE SERIES 018-31 024-31 030-31 036-32 042-32 048-30 060-30 OPERATING WEIGHT (Lb) 118 129 137 160 165 196 213 REFRIGERANT R-22 Control AccuRater (Bypass Type) Charge (Lb) @15 Ft 4.50 5.00 5.50 6.00 6.75 8.50 10.00 COMPRESSOR Type Recip Scroll Scroll CONDENSER FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 1700 1700 2000 3400 3400 3400 3400 Motor HP 1/12 1/12 1/10 1/4 1/4 1/4 1/4 Motor RPM 1110 1100 1100 1100 1100 1100 1100 CONDENSER COIL Copper Tube, Aluminum Plate Fin Face Area (Sq Ft) 7.5 10.8 12.4 13.7 14.9 19.9 22.4 Fins per In. 20 25 25 25 25 25 25 Rows 1 1 1 1 1 1 1 Circuits 1 2 2 2 3 4 4 VALVE CONNECTION (In. ID) Sweat Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIG TUBES* (In. OD) Vapor (0 50 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1-1/8 Vapor (Max Diameter for Long-Line Applications 3/4 3/4 7/8 7/8 1-1/8 1-1/8 1-1/8 Liquid (0 50 Ft Tube Length) 3/8 Liquid (For Long-Line Applications) 3/8 * Tube sizes are for runs up to 50 ft. For tube sets between 50 and 175 ft horizontal or 20 ft vertical differential, consult Residential Split tem Long- Line Application Guideline. NOTE: See unit Installation Instructions for proper installation. METERING DEVICE PISTON UNIT SIZE SERIES IDENTIFICATION NO.* 018-31 57 024-31 61 030-31 70 036-32 73 042-32 80 048-30 88 060-30 98 * Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE SERIES REQUIRED SUBCOOLING 018 10 024 11 030 12 036-32 12 042-32 17 048-30 12 060-30 15 3

Accessories ORDERING NUMBER DESCRIPTION KAATD0101TDR Time-Delay Relay All Sizes KSALA0201R22 Low-Ambient Pressure Switch All Sizes KSALA0401AAA* MotorMaster Low-Ambient Controller All Sizes HC34GE231 (RCD) Ball Bearing Fan Motor Sizes 018 030 HC40GE230 (RCD) Ball Bearing Fan Motor Sizes 036 060 KAAFT0101AAA Evaporator Freeze Thermostat All Sizes KAAWS0101AAA Winter Start Control All Sizes KSACY0101AAA Cycle Protector All Sizes KSACG0604CSM Inlet Grille Kit Size 018 KSACG1004CSM Inlet Grille Kit Sizes 024, 030 KSACG1704CMD Inlet Grille Kit Sizes 036, 042 KSACG2104CMD Inlet Grille Kit Size 048 KSACG2304CMD Inlet Grille Kit Size 060 KSAHS0901AAA Start Assist Capacitor and Relay Sizes 018 036 KSAHS1501AAA Start Assist Capacitor and Relay Size 042 KSAHS1601AAA Start Assist Capacitor and Relay 048, 060 KAACS0201PTC Start Assist PTC All Sizes KAACH1001AAA Crankcase Heater Sizes 018 036 KAACH1201AAA Crankcase Heater Sizes 042 060 KSASH1301TEC Sound Hood Sizes 018 036 KSASH1901CYL Sound Hood Size 042 KSASH2001CYL Sound Hood Sizes 048, 060 KAATX0201RPB TXV Kit (RPB) Size 018 KAATX0301RPB TXV Kit (RPB) Size 024 KAATX0401RPB TXV Kit (RPB) Size 030 KAATX0501RPB TXV Kit (RPB) Sizes 036, 042 KAATX0601RPB TXV Kit (RPB) Size 048 KAATX0701RPB TXV Kit (RPB) Size 060 KSATX0601HSO TXV Kit (Hard Shutoff) Sizes 018 042 KSATX0701HSO TXV Kit (Hard Shutoff) Size 048 KSATX1001HSO TXV Kit (Hard Shutoff) Size 060 KAALP0101LPS Low-Pressure Switch All Sizes KSAHI0101HPS High-Pressure Switch All Sizes P502-8083S (RCD) Filter Drier Sizes 018 036 P502-8163S (RCD) Filter Drier Sizes 042 060 KAALS0101LLS Liquid-Line Solenoid Valve All Sizes KAACF0401MED Coastal Filter Sizes 018 030 KAACF0501LRG Coastal Filter Sizes 036 060 * Fan motor with ball bearings required. THERMOSTAT PKG. TSTATCCPRH01-B TSTATCCPAC01-B TSTATCCNAC01-B TSTATCCBAC01-B TSTATXXSEN01-B TSTATXXBBP01 TSTATXXNBP01 TSTATXXPBP01 TSTATXXCNV10 DESCRIPTION Thermidistat Control Programmable Thermostat with Humidity Control Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Thermostat, Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Builder s Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Outdoor Air Temperature Sensor Backplate for Builder s Thermostat Backplate for Non-Programmable Thermostat Backplate for Programmable Thermostat Thermostat Conversion Kit (4 to 5 wire) 10 Pack 4

Accessory usage guideline REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Low-Ambient Controller or Low-Ambient Pressure Switch Yes No No Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Unit Risers Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV No See Long-Line Application Guideline No Ball Bearing Fan Motor Yes No No * For tubing line sets between 50 and 175 ft, refer to Residential Split tem Long-Line Application Guideline. Only when low-pressure switch is used. Accessory description and usage (Listed alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings, which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when Motor Master Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for scroll compressors in the following applications: Long line Low ambient Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a "soft" boost to the compressor motor at each start up. Usage Guideline: Suggested when compressor power supply is marginal Suggested in reciprocating compressor applications with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Filter Drier Bi-Flow A device for removing contaminants from refrigerant circulating in an air conditioning system: single-direction flow. Usage Guideline: Suggested in all field-connected split-system air conditioners. 8. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 426 ± 10 psig and resets at 320 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. Usage Guideline: Suggested in installations exposed to "very dirty" outdoor air. Suggested in installations where condenser inlet air temperature exceeds 125 F. (51.7 C) 5

Accessory description and usage (Listed alphabetically) 9. Liquid-Line Solenoid Valve (LLS) This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration. NOTE: When LLS is used with reciprocating compressors, Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shut off TXV can be used instead of LLS in single flow air conditioner applications. See Long Line Application Guideline. 10. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F ( 17.8 C) when properly installed. Usage Guideline: A Low-Ambient Pressure Switch or Motor Master Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). 11. MotorMaster -Low-Ambient Controller A fan speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 12 C). Usage Guideline: A Motor Master Low-Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications. 12. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. The device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 13. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Usage Guideline: Suggested when unit is installed closer than 15 ft to quiet areas bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 14. Thermostatic Expansion Valve (TXV) Single-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 15. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Electrical data UNIT SIZE SERIES V/PH OPER VOLTS* COMPRESSOR Max Min LRA RLA FAN FLA 018-31 48.3 8.5 0.5 11.1 14 14 72 68 15 024-31 60.0 10.1 0.5 13.1 14 14 61 58 20 030-31 69.4 12.4 0.8 16.3 14 14 49 47 25 036-32 208-230/1 253 197 84.0 14.7 1.4 19.8 12 12 66 63 30 042-32 103.0 17.9 1.4 23.8 10 10 83 79 40 048-30 140.0 26.4 1.4 34.4 8 10 89 54 50 060-30 169.0 32.1 1.4 41.5 6 8 125 70 60 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75 C (140 or 167 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). Length shown is as measured 1 way along wire path between the unit and service panel for a voltage drop not to exceed 2%. ** Time-delay fuse. FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTES: 1. Control circuit is 24v on all units and requires external power source. 2. Copper wire must be used from service disconnect to unit. 3. All motors and compressors contain internal overload protection. MCA 60 C MIN WIRE SIZE 75 C MIN WIRE SIZE 60 C MAX LENGTH (Ft) 75 C MAX LENGTH (Ft) MAX FUSE** OR CKT BKR AMPS 6

Dimensions A SQ AIR DISCHARGE M AIR IN AIR DISCHARGE AIR IN 3 /8 -IN. DIA TIEDOWN KNOCKOUTS (2) PLACES N J K L AIR IN B FIELD POWER SUPPLY CONN 7/8 -IN. DIA HOLE WITH 1 1 /8 -IN. DIA KNOCKOUT AND 1 3 /8 -IN. DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 /8 -IN. DIA HOLE 3/8 -IN. DIA LIQUID LINE CONN P AIR DISCHARGE E AIR IN G F H D DIA VAPOR LINE CONN 1 1 /4 2 7 /8 NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F, max. 125 F. 3. Series designation is the 13th position of the unit model number. 4. Center of gravity. C A97043 DIMENSIONS (In.) UNIT SIZE SERIES A B C D E F G H J K L M N P MINIMUM MOUNTING PAD DIMENSIONS 018 31 22-1/2 21-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/2 10 10-1/4 22-1/2 x 22-1/2 024 31 22-1/2 29-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/2 10 11-3/4 22-1/2 x 22 1/2 030 31 22-1/2 33-15/16 3-3/16 3/4 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/2 10 12-1/2 22-1/2 x 22-1/2 036 32 30 27-15/16 3-3/16 3/4 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 16 30 x 30 042 32 30 27-15/16 3-3/16 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 16 30 x 30 048 30 30 35-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 16-1/2 30 x 30 060 30 30 39-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 17 30 x 30 7

Combination ratings UNIT SIZE-SERIES 018-31 024-31 INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING CC5A/CD5AW024 23,000 TDR 11.50 11.50 10.65 CC5A/CD5AW030 23,400 TDR 12.00 12.00 10.90 CK5A/CK5BW024 23,000 TDR 11.50 11.50 10.65 CK5A/CK5BW030 23,400 TDR 12.00 12.00 10.90 See notes on pg. 15. 8 SEER TXV CARRIER GAS FURNACE OR TDR *CK5A/CK5BA024 17,500 NONE 10.50 11.00 11.00 10.15 CC5A/CD5AA018 17,000 NONE 10.50 10.50 10.00 CC5A/CD5AA024 17,500 NONE 10.50 11.00 11.00 10.15 CC5A/CD5AW024 17,500 NONE 10.50 11.00 11.00 10.15 CE3AA024 17,500 NONE 10.50 11.00 11.00 10.15 CK3BA024 17,500 NONE 10.50 11.00 11.00 10.15 CK5A/CK5BA018 17,000 NONE 10.20 10.50 10.50 10.00 CK5A/CK5BW024 17,500 NONE 10.50 11.00 11.00 10.15 F(A,B)4(A,B)N(F,C)018 17,000 TDR 10.50 10.50 9.90 F(A,B)4(A,B)N(F,C)024 18,000 TDR 11.00 11.00 10.30 FC4(B,C)NF024 18,000 TDR&TXV 11.00 10.15 FF1DNA018 17,000 TDR 11.00 11.00 10.15 FF1DNA024 18,000 TDR 11.20 11.20 10.20 FG3AAA024 17,500 NONE 10.00 10.50 10.50 10.00 FK4(C,D)NF001 18,500 TDR&TXV 12.50 11.45 FK4(C,D)NF002 18,500 TDR&TXV 12.70 11.50 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 11.50 11.50 10.70 CC5A/CD5AA024 17,500 TDR 12.00 12.00 11.00 CC5A/CD5AW024 17,500 TDR 12.00 12.00 11.00 CE3AA024 17,500 TDR 12.00 12.00 11.05 CK3BA024 17,500 TDR 12.00 12.00 11.25 CK5A/CK5BA018 17,000 TDR 11.50 11.50 10.75 CK5A/CK5BA024 17,500 TDR 12.00 12.00 11.20 CK5A/CK5BW024 17,500 TDR 12.00 12.00 11.20 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,500 TDR 12.00 12.00 11.00 CK5A/CK5BW024 17,500 TDR 12.00 12.00 11.00 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,500 TDR 12.00 12.00 11.00 CK5A/CK5BW024 17,500 TDR 12.00 12.00 11.00 *CK5A/CK5BA030 23,400 NONE 10.50 11.00 11.00 10.10 CC5A/CD5AA024 23,000 NONE 10.40 10.80 10.80 9.95 CC5A/CD5AA030 23,400 NONE 10.50 11.00 11.00 10.10 CC5A/CD5AW024 23,000 NONE 10.40 10.80 10.80 9.95 CC5A/CD5AW030 23,400 NONE 10.50 11.00 11.00 10.10 CE3AA024 23,200 NONE 10.40 10.80 10.80 10.05 CE3AA030 23,600 NONE 10.50 11.00 11.00 10.15 CK3BA024 23,000 NONE 10.40 10.80 10.80 9.95 CK3BA030 23,400 NONE 10.50 11.00 11.00 10.10 CK5A/CK5BA024 23,000 NONE 10.40 10.80 10.80 9.95 CK5A/CK5BW024 23,000 NONE 10.40 10.80 10.80 9.95 CK5A/CK5BW030 23,400 NONE 10.50 11.00 11.00 10.10 F(A,B)4(A,B)N(F,C)024 23,200 TDR 11.00 11.00 10.10 F(A,B)4(A,B)N(F,C)030 23,600 TDR 11.20 11.20 10.25 FC4(B,C)NF024 23,200 TDR&TXV 11.00 10.00 FC4(B,C)NF030 23,600 TDR&TXV 11.20 10.25 FF1DNA024 23,200 TDR 11.00 11.00 9.95 FF1DNA030 23,800 TDR 11.00 11.00 10.15 FG3AAA024 22,600 NONE 10.00 10.50 10.50 9.85 FK4(C,D)NF001 24,000 TDR&TXV 12.50 11.20 FK4(C,D)NF002 24,200 TDR&TXV 12.05 11.30 FK4(C,D)NF003 24,400 TDR&TXV 12.80 11.55 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA024 22,800 TDR 11.50 11.50 10.95 CC5A/CD5AA030 23,000 TDR 12.00 12.00 11.10 CC5A/CD5AW024 22,800 TDR 11.50 11.50 10.90 CC5A/CD5AW030 23,000 TDR 12.00 12.00 11.05 CE3AA024 23,000 TDR 11.50 11.50 10.95 CE3AA030 23,000 TDR 12.00 12.00 11.15 CK3BA024 22,800 TDR 11.50 11.50 11.10 CK3BA030 23,000 TDR 12.00 12.00 11.10 CK5A/CK5BA024 22,800 TDR 11.50 11.50 11.05 CK5A/CK5BA030 23,000 TDR 12.00 12.00 11.10 CK5A/CK5BW024 22,800 TDR 11.50 11.50 11.05 CK5A/CK5BW030 23,000 TDR 12.00 12.00 11.10 COILS + 58MVP040-14 VARIABLE-SPEED FURNACE CC5A/CD5AW030 23,400 TDR 12.00 12.00 10.90 CK5A/CK5BW030 23,400 TDR 12.00 12.00 10.90 COILS + 58MVP0460-14 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,000 TDR 11.50 11.50 10.65 CC5A/CD5AW030 23,400 TDR 12.00 12.00 10.90 CK5A/CK5BW024 23,000 TDR 11.50 11.50 10.65 CK5A/CK5BW030 23,400 TDR 12.00 12.00 10.90 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE EER

Combination ratings continued UNIT SIZE-SERIES 030-31 036-32 See notes on pg. 15. INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR *CK5A/CK5BA036 29,600 NONE 10.60 11.00 11.00 10.20 CC5A/CD5AA030 28,600 NONE 10.30 10.70 10.70 9.95 CC5A/CD5AA036 29,600 NONE 10.60 11.00 11.00 11.20 CC5A/CD5AW030 28,800 NONE 10.30 10.70 10.70 9.95 CC5A/CD5AW036 29,600 NONE 10.60 11.00 11.00 10.20 CE3AA030 28,800 NONE 10.30 10.70 10.70 10.00 CE3AA036 29,200 NONE 10.50 10.80 10.80 10.10 CK3BA030 28,600 NONE 10.30 10.70 10.70 9.95 CK3BA036 29,600 NONE 10.60 11.00 11.00 10.20 CK5A/CK5BA030 28,600 NONE 10.30 10.70 10.70 9.95 CK5A/CK5BT036 29,600 NONE 10.60 11.00 11.00 10.20 CK5A/CK5BW030 28,800 NONE 10.30 10.70 10.70 9.95 CK5A/CK5BW036 29,600 NONE 10.60 11.00 11.00 10.20 F(A,B)4(A,B)N(F,C)030 28,800 TDR 10.80 10.80 10.05 F(A,B)4(A,B)N(F,C)036 29,400 TDR 11.00 11.00 9.95 FC4(B,C)NF030 28,800 TDR&TXV 10.80 10.05 FC4(B,C)NF036 29,400 TDR&TXV 11.00 9.95 FF1DNA030 29,000 TDR 10.80 10.80 10.00 FG3AAA036 29,000 NONE 10.40 10.80 10.80 10.05 FK4(C,D)NF001 29,000 TDR&TXV 11.50 10.80 FK4(C,D)NF002 29,200 TDR&TXV 11.50 10.85 FK4(C,D)NF003 29,600 TDR&TXV 12.00 11.20 FK4(C,D)NF005 30,000 TDR&TXV 12.50 11.45 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,600 TDR 11.50 11.50 10.60 CC5A/CD5AA036 29,000 TDR 12.00 12.00 10.90 CC5A/CD5AW030 28,600 TDR 11.50 11.50 10.60 CE3AA030 28,600 TDR 11.50 11.50 10.70 CE3AA036 29,000 TDR 11.50 11.50 10.75 CK3BA030 28,600 TDR 11.50 11.50 10.65 CK3BA036 29,000 TDR 12.00 12.00 10.95 CK5A/CK5BA030 28,600 TDR 11.50 11.50 10.65 CK5A/CK5BA036 29,000 TDR 12.00 12.00 10.95 CK5A/CK5BT036 29,000 TDR 12.00 12.00 10.95 CK5A/CK5BW030 28,600 TDR 11.50 11.50 10.65 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,600 TDR 11.50 11.50 10.75 CC5A/CD5AA036 29,000 TDR 12.00 12.00 11.05 CC5A/CD5AW030 28,600 TDR 11.50 11.50 10.75 CC5A/CD5AW036 29,000 TDR 12.00 12.00 11.05 CE3AA030 28,600 TDR 11.50 11.50 10.85 CE3AA036 29,000 TDR 11.50 11.50 10.95 CK3BA030 28,600 TDR 11.50 11.50 10.75 CK3BA036 29,000 TDR 12.00 12.00 11.10 CK5A/CK5BA030 28,600 TDR 11.50 11.50 10.75 CK5A/CK5BA036 29,000 TDR 12.00 12.00 11.10 CK5A/CK5BW030 28,600 TDR 11.50 11.50 10.75 CK5A/CK5BW036 29,000 TDR 12.00 12.00 11.10 COILS + 58MVP040-14 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,600 TDR 11.00 11.00 10.50 CC5A/CD5AW036 29,000 TDR 11.50 11.50 11.05 CK5A/CK5BW030 28,600 TDR 11.00 11.00 10.50 CK5A/CK5BW036 29,000 TDR 11.50 11.50 11.05 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,600 TDR 11.00 11.00 10.50 CK5A/CK5BW030 28,600 TDR 11.00 11.00 10.50 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,600 TDR 11.00 11.00 10.50 CC5A/CD5AW036 29,000 TDR 11.50 11.50 11.05 CK5A/CK5BW030 28,600 TDR 11.00 11.00 10.50 CK5A/CK5BW036 29,000 TDR 11.50 11.50 11.05 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,600 TDR 11.00 11.00 10.50 CC5A/CD5AW036 29,000 TDR 11.50 11.50 11.05 CK5A/CK5BW030 28,600 TDR 11.00 11.00 10.50 CK5A/CK5BW036 29,000 TDR 11.50 11.50 11.05 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AW030 28,600 TDR 11.50 11.50 10.50 CC5A/CD5AW036 29,000 TDR 12.00 12.00 11.05 CK5A/CK5BW030 28,600 TDR 11.50 11.50 10.50 CK5A/CK5BW036 29,000 TDR 12.00 12.00 11.05 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,000 TDR 12.00 12.00 11.05 CK5A/CK5BW036 29,000 TDR 12.00 12.00 11.05 *CK5A/CK5BA042 35,000 NONE 10.70 11.00 11.00 10.10 CC5A/CD5AA036 35,000 NONE 10.70 11.00 11.00 10.10 CC5A/CD5AA042 35,000 NONE 10.70 11.00 11.00 10.10 CC5A/CD5AW036 35,000 NONE 10.70 11.00 11.00 10.10 EER 9

Combination ratings continued UNIT SIZE-SERIES 036-32 See notes on pg. 15. 10 INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR CE3AA036 34,400 NONE 10.50 10.80 10.80 10.00 CE3AA042 35,200 NONE 10.70 11.00 11.00 10.15 CK3BA036 35,000 NONE 10.70 11.00 11.00 10.10 CK3BA042 35,000 NONE 10.70 11.00 11.00 10.10 CK5A/CK5BA036 35,000 NONE 10.70 11.00 11.00 10.10 CK5A/CK5BT036 35,000 NONE 10.70 11.00 11.00 10.10 CK5A/CK5BT042 35,000 NONE 10.70 11.00 11.00 10.10 CK5A/CK5BW036 35,000 NONE 10.70 11.00 11.00 10.10 F(A,B)4(A,B)N(F,B,C)042 35,000 TDR 11.00 11.00 10.05 F(A,B)4(A,B)N(F,C)036 34,400 TDR 10.70 10.70 9.40 FC4(B,C)N(F,B)042 35,000 TDR&TXV 11.00 10.05 FC4(B,C)NB054 36,000 TDR&TXV 11.80 10.70 FC4(B,C)NF036 34,400 TDR&TXV 10.70 9.80 FG3AAA036 34,200 NONE 10.40 10.80 10.80 9.90 FK4(C,D)NB006 36,000 TDR&TXV 12.50 11.60 FK4(C,D)NF001 34,200 TDR&TXV 11.20 10.45 FK4(C,D)NF002 34,400 TDR&TXV 11.50 10.45 FK4(C.D)NF003 35,200 TDR&TXV 11.80 11.00 FK4(C,D)NF005 36,000 TDR&TXV 12.00 10.85 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,200 TDR 11.50 11.50 10.65 CE3AA036 34,200 TDR 11.50 11.50 10.55 CE3AA042 34,400 TDR 11.50 11.50 10.75 CK3BA036 34,200 TDR 11.75 11.75 10.65 CK5A/CK5BA036 34,200 TDR 11.50 11.50 10.65 CK5A/CK5BE042 34,600 TDR 11.50 11.50 10.75 CK5A/CK5BT036 34,200 TDR 11.50 11.50 10.65 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,200 TDR 11.50 11.50 10.80 CC5A/CD5AA042 34,400 TDR 11.50 11.50 10.90 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CE3AA036 34,200 TDR 11.50 11.50 10.70 CE3AA042 34,400 TDR 11.50 11.50 10.60 CK3BA036 34,200 TDR 11.50 11.50 10.80 CK3BA042 34,400 TDR 11.50 11.50 10.85 CK5A/CK5BA036 34,200 TDR 11.50 11.50 10.80 CK5A/CK5BA042 34,400 TDR 11.50 11.50 10.85 CK5A/CK5BE042 34,600 TDR 11.50 11.50 10.90 CK5A/CK5BT036 34,200 TDR 11.50 11.50 10.80 CK5A/CK5BT042 34,400 TDR 11.50 11.50 10.85 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.80 COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,200 TDR 11.50 11.50 10.85 CC5A/CD5AA042 34,400 TDR 12.00 12.00 11.00 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.85 CC5A/CD5AW042 34,400 TDR 12.00 12.00 10.95 CE3AA036 34,200 TDR 11.50 11.50 10.80 CE3AA042 34,400 TDR 11.50 11.50 10.95 CK3BA036 34,200 TDR 11.50 11.50 10.90 CK3BA042 34,400 TDR 12.00 12.00 10.95 CK5A/CK5BA036 34,200 TDR 11.50 11.50 10.90 CK5A/CK5BA042 34,400 TDR 12.00 12.00 10.95 CK5A/CK5BT036 34,200 TDR 11.50 11.50 10.90 CK5A/CK5BT042 34,400 TDR 12.00 12.00 10.95 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.90 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 10.95 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CC5A/CD5AW042 34,400 TDR 11.50 11.50 10.90 CE3AA036 34,200 TDR 11.50 11.50 10.75 CE3AA042 34,400 TDR 11.50 11.50 10.95 CK3BA042 34,400 TDR 11.50 11.50 10.90 CK5A/CK5BA042 34,400 TDR 11.50 11.50 10.90 CK5A/CK5BT042 34,400 TDR 11.50 11.50 10.90 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.85 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 11.05 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.85 CC5A/CD5AW042 34,400 TDR 12.00 12.00 11.00 CE3AA036 34,200 TDR 11.50 11.50 10.80 CE3AA042 34,400 TDR 11.50 11.50 11.00 CK3BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BT042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.90 COILS + 58MVP040-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 10.85 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CK5A/CK5BA042 34,400 TDR 12.00 12.00 10.85 CK5A/CK5BT042 34,400 TDR 12.00 12.00 10.85 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.80 EER

Combination ratings continued UNIT SIZE-SERIES 036-32 042-32 See notes on pg. 15. INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AA036 34,200 TDR 11.50 11.50 10.80 CK3BA036 34,200 TDR 11.50 11.50 10.80 CK5A/CK5BA036 34,200 TDR 11.50 11.50 10.80 CK5A/CK5BT036 34,200 TDR 11.50 11.50 10.80 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 11.00 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CK3BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BT042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.80 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 11.00 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CK3BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BT042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.80 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 11.00 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CK3BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BT042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.80 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 12.00 12.00 11.00 CC5A/CD5AW036 34,200 TDR 11.50 11.50 10.80 CK5A/CK5BA042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BT042 34,400 TDR 12.00 12.00 11.00 CK5A/CK5BW036 34,200 TDR 11.50 11.50 10.80 *CD5AA048 40,500 NONE 10.70 11.00 11.00 10.00 CC5A/CD5AA042 40,500 NONE 10.70 11.00 11.00 10.00 CC5A/CD5AC048 40,000 NONE 10.60 11.00 11.00 9.85 CC5A/CD5AW042 40,000 NONE 10.70 11.00 11.00 9.85 CC5A/CD5AW048 40,500 NONE 10.70 11.00 11.00 10.00 CE3AA042 40,500 NONE 10.70 11.00 11.00 10.05 CE3AA048 41,000 NONE 10.70 11.00 11.00 10.05 CF5AA048 41,000 NONE 10.70 11.00 11.00 10.00 CK3BA042 40,500 NONE 10.70 11.00 11.00 10.00 CK3BA048 40,500 NONE 10.70 11.00 11.00 10.05 CK5A/CK5BA042 40,500 NONE 10.70 11.00 11.00 10.00 CK5A/CK5BA048 40,500 NONE 10.70 11.00 11.00 10.05 CK5A/CK5BE042 40,500 NONE 10.70 11.00 11.00 10.05 CK5A/CK5BT042 40,500 NONE 10.70 11.00 11.00 10.00 CK5A/CK5BT048 40,500 NONE 10.70 11.00 11.00 10.05 CK5A/CK5BW048 40,500 NONE 10.70 11.00 11.00 10.05 F(A,B)4BN(F,B,C)042 40,500 TDR 10.80 10.80 10.80 9.85 F(A,B)4BN(F,B,C)048 41,000 TDR 11.00 11.00 11.00 10.00 FC4CN(F,B)042 40,500 TDR&TXV 10.80 9.85 FC4CN(F,B)048 41,000 TDR&TXV 11.00 9.85 FC4CNB054 42,000 TDR&TXV 11.50 10.60 FG3AAA048 40,500 NONE 10.80 11.10 11.10 9.95 FK4DNB006 42,000 TDR&TXV 12.50 11.45 FK4DNF003 40,500 TDR&TXV 11.50 10.80 FK4DNF005 42,000 TDR&TXV 12.00 11.05 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CE3AA042 40,500 TDR 11.50 11.50 10.35 CE3AA048 40,500 TDR 11.50 11.50 10.40 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.35 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.55 CC5A/CD5AC048 39,500 TDR 11.50 11.50 10.45 CD5AA048 40,000 TDR 12.00 12.00 10.65 CE3AA042 40,500 TDR 11.50 11.50 10.60 CE3AA048 40,500 TDR 11.50 11.50 10.65 CK3BA042 40,000 TDR 11.50 11.50 10.55 CK3BA048 40,000 TDR 12.00 12.00 10.70 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.55 CK5A/CK5BA048 40,000 TDR 12.00 12.00 10.70 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.60 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.55 CK5A/CK5BT048 40,000 TDR 12.00 12.00 10.70 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.55 CC5A/CD5AC048 39,500 TDR 11.50 11.50 10.45 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.50 CC5A/CD5AW048 40,000 TDR 12.00 12.00 10.70 EER 11

Combination ratings continued UNIT SIZE-SERIES 12 INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR CD5AA048 40,000 TDR 12.00 12.00 10.65 CE3AA042 40,500 TDR 11.50 11.50 10.60 CE3AA048 40,500 TDR 11.50 11.50 10.65 CK3BA042 40,000 TDR 11.50 11.50 10.55 CK3BA048 40,000 TDR 12.00 12.00 10.70 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BA048 40,000 TDR 12.00 12.00 10.70 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.55 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BT048 40,000 TDR 12.00 12.00 10.70 CK5A/CK5BW048 40,000 TDR 12.00 12.00 10.75 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.70 CC5A/CD5AC048 39,500 TDR 11.50 11.50 10.60 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.60 CC5A/CD5AW048 40,000 TDR 12.00 12.00 10.80 CD5AA048 40,000 TDR 12.00 12.00 10.75 CE3AA042 40,500 TDR 11.50 11.50 10.75 CE3AA048 40,500 TDR 11.50 11.50 10.80 CK3BA042 40,000 TDR 11.50 11.50 10.65 CK3BA048 40,000 TDR 12.00 12.00 10.85 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.65 CK5A/CK5BA048 40,000 TDR 12.00 12.00 10.80 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.65 CK5A/CK5BT048 40,000 TDR 12.00 12.00 10.80 CK5A/CK5BW048 40,000 TDR 12.00 12.00 10.90 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.70 CC5A/CD5AC048 39,500 TDR 11.50 11.50 10.60 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.65 CC5A/CD5AW048 40,000 TDR 12.00 12.00 10.80 CD5AA048 40,000 TDR 12.00 12.00 10.80 CE3AA042 40,500 TDR 11.50 11.50 10.75 CE3AA048 40,500 TDR 11.50 11.50 10.80 CK3BA042 40,000 TDR 11.50 11.50 10.70 CK3BA048 40,000 TDR 12.00 12.00 10.85 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.70 CK5A/CK5BA048 40,000 TDR 12.00 12.00 10.85 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.70 CK5A/CK5BT048 40,000 TDR 12.00 12.00 10.85 042-32 CK5A/CK5BW048 40,000 TDR 12.00 12.00 10.90 COILS + 58MVP040-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.35 CC5A/CD5AC048 40,000 TDR 11.50 11.50 10.25 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.25 CC5A/CD5AW048 40,000 TDR 11.50 11.50 10.45 CD5AA048 40,000 TDR 11.50 11.50 10.40 CE3AA042 40,000 TDR 11.50 11.50 10.40 CE3AA048 40,000 TDR 11.50 11.50 10.45 CK3BA042 40,000 TDR 11.50 11.50 10.30 CK3BA048 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.30 CK5A/CK5BA048 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.30 CK5A/CK5BT048 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BW048 40,500 TDR 11.50 11.50 10.50 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.45 CC5A/CD5AC048 40,000 TDR 11.50 11.50 10.35 CD5AA048 40,500 TDR 11.50 11.50 10.50 CE3AA042 40,000 TDR 11.50 11.50 10.50 CE3AA048 40,500 TDR 11.50 11.50 10.55 CK3BA042 40,000 TDR 11.50 11.50 10.45 CK3BA048 40,500 TDR 11.50 11.50 10.60 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BA048 40,500 TDR 11.50 11.50 10.55 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BT048 40,500 TDR 11.50 11.50 10.55 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.30 CC5A/CD5AC048 39,500 TDR 11.50 11.50 10.20 CC5A/CD5AW042 39,500 TDR 11.50 11.50 10.25 CC5A/CD5AW048 40,500 TDR 11.50 11.50 10.40 CD5AA048 40,500 TDR 11.50 11.50 10.40 CE3AA042 40,000 TDR 11.50 11.50 10.35 CE3AA048 40,500 TDR 11.50 11.50 10.40 CK3BA042 40,000 TDR 11.50 11.50 10.30 CK3BA048 40,500 TDR 11.50 11.50 10.45 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.30 CK5A/CK5BA048 40,500 TDR 11.50 11.50 10.40 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.35 See notes on pg. 15. EER

Combination ratings continued UNIT SIZE-SERIES INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.30 CK5A/CK5BT048 40,500 TDR 11.50 11.50 10.40 CK5A/CK5BW048 40,500 TDR 11.50 11.50 10.50 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.40 CC5A/CD5AC048 40,000 TDR 11.50 11.50 10.30 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.35 CC5A/CD5AW048 40,500 TDR 11.50 11.50 10.50 CD5AA048 40,500 TDR 11.50 11.50 10.50 CE3AA042 40,000 TDR 11.50 11.50 10.45 CE3AA048 40,500 TDR 11.50 11.50 10.50 CK3BA042 40,000 TDR 11.50 11.50 10.40 CK3BA048 40,500 TDR 11.50 11.50 10.55 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.40 CK5A/CK5BA048 40,500 TDR 11.50 11.50 10.55 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.40 CK5A/CK5BT048 40,500 TDR 11.50 11.50 10.55 CK5A/CK5BW048 40,500 TDR 11.50 11.50 10.60 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.45 CC5A/CD5AC048 40,000 TDR 11.50 11.50 10.40 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.40 CC5A/CD5AW048 40,500 TDR 12.00 12.00 10.60 042-32 CD5AA048 40,500 TDR 12.00 12.00 10.60 CE3AA042 40,000 TDR 11.50 11.50 10.50 CE3AA048 40,500 TDR 11.50 11.50 10.60 CK3BA042 40,000 TDR 11.50 11.50 10.45 CK3BA048 40,500 TDR 12.00 12.00 10.65 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BA048 40,500 TDR 12.00 12.00 10.60 CK5A/CK5BE042 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.45 CK5A/CK5BT048 40,500 TDR 12.00 12.00 10.60 CK5A/CK5BW048 40,500 TDR 12.00 12.00 10.70 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 11.50 11.50 10.50 CC5A/CD5AC048 40,000 TDR 11.50 11.50 10.40 CC5A/CD5AW042 40,000 TDR 11.50 11.50 10.45 CC5A/CD5AW048 40,500 TDR 12.00 12.00 10.60 CD5AA048 40,500 TDR 12.00 12.00 10.60 CE3AA042 40,000 TDR 11.50 11.50 10.60 CE3AA048 40,500 TDR 11.50 11.50 10.65 CK3BA042 40,000 TDR 11.50 11.50 10.50 CK3BA048 40,500 TDR 12.00 12.00 10.65 CK5A/CK5BA042 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BA048 40,500 TDR 12.00 12.00 10.65 CK5A/CK5BT042 40,000 TDR 11.50 11.50 10.50 CK5A/CK5BT048 40,500 TDR 12.00 12.00 10.65 CK5A/CK5BW048 40,500 TDR 12.00 12.00 10.70 *CC5A/CD5AA060 46,000 NONE 10.60 11.00 11.00 9.90 CC5A/CD5AC048 45,000 NONE 10.40 10.80 10.80 9.80 CC5A/CD5AW048 46,000 NONE 10.50 10.80 10.80 9.85 CC5A/CD5AW060 47,500 NONE 10.80 11.10 11.10 10.10 CD5AA048 46,000 NONE 10.50 10.80 10.80 9.85 CE3AA048 46,500 NONE 10.70 11.00 11.00 9.95 CE3AA060 47,500 NONE 10.80 11.10 11.10 10.15 CF5AA048 46,000 NONE 10.70 11.00 11.00 9.95 CK3BA048 46,000 NONE 10.50 10.80 10.80 9.90 CK3BA060 46,000 NONE 10.60 11.00 11.00 10.20 CK5A/CK5BA048 46,000 NONE 10.50 10.80 10.80 9.90 CK5A/CK5BA060 46,000 NONE 10.60 11.00 11.00 10.05 CK5A/CK5BT048 46,000 NONE 10.50 10.80 10.80 9.90 CK5A/CK5BT060 46,000 NONE 10.60 11.00 11.00 10.05 CK5A/CK5BW048 46,000 NONE 10.50 10.80 10.80 9.90 CK5A/CK5BX060 47,500 NONE 10.80 11.00 11.00 10.20 048-30 F(A,B)4(A,B)N(F,B,C)048 F(A,B)4(A,B)N(F,B,C)060 46,500 48,000 TDR TDR 10.80 11.00 10.80 11.00 9.80 9.90 FB4(A,B)NB070 48,000 TDR 11.40 11.40 10.25 FC4(B,C)N(F,B)048 46,500 TDR&TXV 11.00 9.80 FC4(B,C)N(F,B)060 48,000 TDR&TXV 11.00 9.90 FC4(B,C)NB054 48,000 TDR&TXV 11.40 10.30 FC4(B,C)NB070 48,000 TDR&TXV 11.40 10.25 FG3AAA048 46,000 NONE 10.50 10.80 10.80 9.85 FG3AAA060 47,500 NONE 10.70 11.00 11.00 10.10 FK4(C,D)NB006 48,000 TDR&TXV 12.00 11.15 FK4(C,D)NF005 47,500 TDR&TXV 11.50 10.80 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AC048 44,500 TDR 11.00 11.00 10.10 CD5AA048 45,000 TDR 11.00 11.00 10.20 CE3AA048 45,000 TDR 11.00 11.00 10.20 CE3AA060 45,500 TDR 11.50 11.50 10.55 CK3BA048 45,000 TDR 11.00 11.00 10.25 See notes on pg. 15. EER 13

Combination ratings continued UNIT SIZE-SERIES 14 INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR CK5A/CK5BA048 45,000 TDR 11.00 11.00 10.25 CK5A/CK5BT048 45,000 TDR 11.00 11.00 10.25 COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 11.50 11.50 10.45 CC5A/CD5AC048 45,000 TDR 11.00 11.00 10.30 CC5A/CD5AW048 45,000 TDR 11.00 11.00 10.40 CD5AA048 45,000 TDR 11.00 11.00 10.40 CE3AA048 45,000 TDR 11.00 11.00 10.40 CE3AA060 45,500 TDR 11.50 11.50 10.70 CK3BA048 45,000 TDR 11.00 11.00 10.40 CK3BA060 45,500 TDR 11.50 11.50 10.70 CK5A/CK5BA048 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BA060 45,500 TDR 11.50 11.50 10.70 CK5A/CK5BT048 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BT060 45,500 TDR 11.50 11.50 10.70 CK5A/CK5BW048 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BX060 46,000 TDR 11.50 11.50 10.90 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 11.50 11.50 10.40 CC5A/CD5AC048 44,500 TDR 11.00 11.00 10.25 CC5A/CD5AW048 45,000 TDR 11.00 11.00 10.35 CC5A/CD5AW060 46,000 TDR 11.50 11.50 10.70 CD5AA048 45,500 TDR 11.00 11.00 10.35 CE3AA048 45,000 TDR 11.00 11.00 10.35 CE3AA060 45,500 TDR 11.50 11.50 10.70 CK3BA048 45,000 TDR 11.00 11.00 10.40 CK3BA060 45,500 TDR 11.50 11.50 10.65 CK5A/CK5BA048 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BA060 45,500 TDR 11.50 11.50 10.65 CK5A/CK5BT048 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BT060 45,500 TDR 11.50 11.50 10.65 CK5A/CK5BW048 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BX060 46,000 TDR 11.50 11.50 10.85 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,500 TDR 11.50 11.50 10.50 CC5A/CD5AC048 44,500 TDR 11.00 11.00 10.35 CC5A/CD5AW048 45,000 TDR 11.00 11.00 10.45 CC5A/CD5AW060 46,000 TDR 12.00 12.00 10.75 CD5AA048 45,000 TDR 11.00 11.00 10.45 048-30 CE3AA048 CE3AA060 45,000 45,500 TDR TDR 11.00 11.50 11.00 11.50 10.45 10.75 CK3BA048 45,000 TDR 11.00 11.00 10.45 CK3BA060 45,500 TDR 11.50 11.50 10.75 CK5A/CK5BA048 45,000 TDR 11.00 11.00 10.45 CK5A/CK5BA060 45,500 TDR 11.50 11.50 10.75 CK5A/CK5BT048 45,000 TDR 11.00 11.00 10.45 CK5A/CK5BT060 45,500 TDR 11.50 11.50 10.75 CK5A/CK5BW048 45,000 TDR 11.00 11.00 10.45 CK5A/CK5BX060 46,000 TDR 12.00 12.00 10.95 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AC048 44,500 TDR 11.00 11.00 10.00 CK3BA048 45,000 TDR 11.00 11.00 10.05 CK3BA060 45,000 TDR 11.50 11.50 10.40 CK5A/CK5BA048 45,000 TDR 11.00 11.00 10.05 CK5A/CK5BT048 45,000 TDR 11.00 11.00 10.05 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CK3BA048 45,000 TDR 11.00 11.00 9.95 CK3BA060 45,000 TDR 11.50 11.50 10.35 CK5A/CK5BA048 45,000 TDR 11.00 11.00 9.95 CK5A/CK5BA060 45,000 TDR 11.00 11.00 10.10 CK5A/CK5BT048 45,000 TDR 11.00 11.00 9.95 CK5A/CK5BT060 45,000 TDR 11.00 11.00 10.10 CK5A/CK5BX060 46,000 TDR 11.50 11.50 10.35 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA060 45,000 TDR 11.00 11.00 10.15 CC5A/CD5AC048 44,500 TDR 11.00 11.00 10.00 CC5A/CD5AW060 46,000 TDR 11.50 11.50 10.45 CK3BA048 45,000 TDR 11.00 11.00 10.25 CK3BA060 45,000 TDR 11.50 11.50 10.60 CK5A/CK5BA048 45,000 TDR 11.00 11.00 10.25 CK5A/CK5BA060 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BT048 45,000 TDR 11.00 11.00 10.25 CK5A/CK5BT060 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BX060 46,000 TDR 11.50 11.50 10.60 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CK3BA048 45,000 TDR 11.00 11.00 10.25 CK3BA060 45,000 TDR 11.50 11.50 10.65 CK5A/CK5BA060 45,000 TDR 11.00 11.00 10.40 CK5A/CK5BT060 45,000 TDR 11.00 11.00 10.40 See notes on pg. 15. EER

Combination ratings continued UNIT SIZE-SERIES 048-30 060-30 INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER TXV CARRIER GAS FURNACE OR TDR CK5A/CK5BW048 45,000 TDR 11.00 10.25 CK5A/CK5BX060 46,000 TDR 11.50 10.65 *CC5A/CD5AW060 56,000 NONE 10.80 11.00 11.00 9.80 CC5A/CD5AA060 54,000 NONE 10.60 10.80 10.80 9.65 CE3AA060 56,500 NONE 10.80 11.00 11.00 9.90 CK3BA060 54,000 NONE 10.60 10.80 10.80 9.90 CK5A/CK5BA060 54,000 NONE 10.60 10.80 10.80 9.80 CK5A/CK5BT060 54,000 NONE 10.60 10.80 10.80 9.80 CK5A/CK5BX060 56,000 NONE 10.80 11.00 11.00 9.90 F(A,B)4(A,B)N(F,B,C)060 56,500 TDR 10.70 10.70 9.50 FB4(A,B)NB070 57,500 TDR 11.00 11.00 9.90 FC4(B,C)N(F,B)060 56,500 TDR&TXV 10.70 9.50 FC4(B,C)NB070 57,500 TDR&TXV 11.00 9.90 FG3AAA060 56,000 NONE 10.70 11.00 11.00 9.80 FK4(C,D)NB006 57,500 TDR&TXV 11.50 10.60 COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 54,000 TDR 11.00 11.00 9.90 CE3AA060 54,000 TDR 11.00 11.00 10.20 CK3BA060 54,000 TDR 11.00 11.00 10.05 CK5A/CK5BA060 54,000 TDR 11.00 11.00 10.05 CK5A/CK5BT060 54,000 TDR 11.00 11.00 10.05 CK5A/CK5BX060 55,000 TDR 11.50 11.50 10.35 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 54,000 TDR 11.00 11.00 9.85 CC5A/CD5AW060 55,000 TDR 11.20 11.20 10.15 CE3AA060 54,000 TDR 11.00 11.00 10.20 CK3BA060 54,000 TDR 11.00 11.00 10.00 CK5A/CK5BA060 54,000 TDR 11.00 11.00 10.00 CK5A/CK5BT060 54,000 TDR 11.00 11.00 10.00 CK5A/CK5BX060 55,000 TDR 11.50 11.50 10.35 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 54,000 TDR 11.00 11.00 9.95 CC5A/CD5AW060 55,000 TDR 11.20 11.20 10.15 CE3AA060 54,000 TDR 11.00 11.00 10.25 CK3BA060 54,000 TDR 11.00 11.00 10.10 CK5A/CK5BA060 54,000 TDR 11.00 11.00 10.10 CK5A/CK5BT060 54,000 TDR 11.00 11.00 10.10 CK5A/CK5BX060 55,000 TDR 11.50 11.50 10.40 *Tested combination. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR. Based on computer simulation. TXV must be hard shutoff type. EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio TDR Time-Delay Relay TXV Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Minimum outdoor operating ambient in cooling mode is 55 F (12.8 C), maximum 125 F (51.7 C). EER 15

Detailed cooling capacities* EVAPORATOR AIR CFM EWB See notes on pg. 26. CONDENSER ENTERING AIR TEMPERATURES F 75 85 95 105 115 125 Sens kw** Sens kw** Sens kw** Sens kw** Sens kw** Sens kw** 38CMC018-31 Outdoor Section With CK5A/CK5B024 Section 72 21.4 10.1 1.56 20.2 9.67 1.69 19.0 9.21 1.80 17.8 8.75 1.91 16.6 8.30 2.01 15.4 7.87 2.11 525 67 19.4 17.4 12.5 14.8 1.54 1.51 18.3 16.4 12.0 14.3 1.65 1.61 17.1 15.4 11.6 13.8 1.75 1.70 16.0 14.4 11.1 13.3 1.85 1.80 14.9 13.3 10.6 12.8 1.94 1.88 13.7 12.3 10.2 12.2 2.03 1.96 57 16.2 16.2 1.49 15.4 15.4 1.59 14.7 14.7 1.68 13.9 13.9 1.77 13.1 13.1 1.87 12.2 12.2 1.96 72 21.9 10.5 1.61 20.6 10.1 1.73 19.4 9.61 1.85 18.1 9.15 1.96 16.8 8.69 2.06 15.6 8.24 2.16 600 67 19.8 17.9 13.2 15.8 1.58 1.55 18.7 16.8 12.7 15.3 1.70 1.65 17.5 15.7 12.3 14.7 1.80 1.75 16.3 14.7 11.8 14.2 1.90 1.85 15.1 13.6 11.3 13.5 2.00 1.93 14.0 12.7 10.8 12.7 2.08 2.02 57 16.9 16.9 1.54 16.1 16.1 1.64 15.3 15.3 1.74 14.4 14.4 1.83 13.6 13.6 1.93 12.7 12.7 2.02 72 22.3 10.9 1.65 21.0 10.4 1.77 19.7 9.97 1.89 18.4 9.50 2.00 17.0 9.04 2.11 15.7 8.59 2.21 675 67 20.2 18.2 13.9 16.7 1. 1.59 19.0 17.1 13.4 16.1 1.73 1.70 17.8 16.0 12.9 15.5 1.85 1.80 16.6 14.9 12.4 14.9 1.95 1.89 15.3 14.0 11.9 14.0 2.04 1.99 14.1 13.1 11.5 13.1 2.13 2.08 57 17.5 17.5 1.58 16.6 16.6 1.69 15.8 15.8 1.79 14.9 14.9 1.89 14.0 14.0 1.98 13.1 13.1 2.08 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 018 0.97 0.99 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE 024 1.00 1.00 CC5A/CD5AA 018 0.97 0.92 CC5A/CD5AW 024 1.00 1.00 024 1.00 0.92 CE3AA 024 1.00 1.00 CC5A/CD5AW 024 1.00 0.92 CK3BA 024 1.00 1.00 CE3AA 024 1.00 0.92 CK5A/CK5BA 018 0.97 0.99 CK3BA 024 1.00 0.90 024 1.00 1.00 CK5A/CK5BA 018 0.97 0.92 CK5A/CK5BW 024 1.00 1.00 024 1.00 0.91 F(A,B)4(A,B)N(F,C) 018 0.97 1.00 CK5A/CK5BW 024 1.00 0.91 024 1.03 1.01 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE FC4(B,C)NF 024 1.03 1.03 CC5A/CD5AW 024 1.00 0.92 FF1DNA 018 0.97 0.97 CK5A/CK5BW 024 1.00 0.92 024 1.03 1.02 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE FG3AAA 024 1.00 1.02 CC5A/CD5AW 024 1.00 0.92 FK4(C,D)NF 001 1.06 0.94 CK5A/CK5BW 024 1.00 0.92 002 1.06 0.93 16

Detailed cooling capacities* continued EVAPORATOR AIR CFM EWB See notes on pg. 26. CONDENSER ENTERING AIR TEMPERATURES F 75 85 95 105 115 125 Sens kw** Sens kw** Sens kw** Sens kw** Sens kw** Sens kw** 38CMC024-31 Outdoor Section With CK5A/CK5B030 Section 72 28.2 13.6 2.06 26.8 13.1 2.22 25.3 12.5 2.38 23.8 12.0 2.52 22.2 11.4 2.64 20.6 10.8 2.77 700 67 25.7 23.3 17.0 20.2 2.03 1.99 24.3 22.0 16.4 19.6 2.17 2.11 23.0 20.7 15.8 18.9 2.31 2.24 21.5 19.3 15.2 18.2 2.43 2.36 20.0 18.0 14.6 17.5 2.55 2.46 18.5 16.7 14.0 16.6 2.66 2.56 57 21.8 21.8 1.95 20.9 20.9 2.09 19.8 19.8 2.22 18.8 18.8 2.33 17.7 17.7 2.45 16.6 16.6 2.56 72 28.8 14.2 2.11 27.3 13.6 2.27 25.8 13.1 2.43 24.2 12.5 2.57 22.5 11.9 2.70 20.9 11.3 2.82 800 67 26.2 23.8 17.9 21.5 2.07 2.03 24.8 22.5 17.4 20.9 2.22 2.17 23.4 21.1 16.8 20.1 2.36 2.29 21.9 19.8 16.1 19.4 2.49 2.41 20.4 18.4 15.5 18.4 2.61 2.53 18.8 17.2 14.9 17.2 2.72 2.64 57 22.7 22.7 2.02 21.7 21.7 2.15 20.6 20.6 2.28 19.5 19.5 2.40 18.4 18.4 2.52 17.2 17.2 2.64 72 29.2 14.7 2.15 27.7 14.2 2.32 26.2 13.6 2.47 24.5 13.0 2. 22.8 12.4 2.75 21.1 11.8 2.88 900 67 26.7 24.2 18.9 22.7 2.13 2.08 25.2 22.9 18.3 22.0 2.27 2.22 23.8 21.6 17.7 21.2 2.41 2.35 22.2 20.2 17.1 20.2 2.54 2.47 20.6 19.0 16.5 19.0 2.66 2.59 19.0 17.8 15.8 17.8 2.77 2.71 57 23.5 23.5 2.07 22.5 22.5 2.21 21.4 21.4 2.35 20.2 20.2 2.47 19.0 19.0 2.59 17.8 17.8 2.71 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 024 0.98 1.00 CC5A/CD5AW 024 0.97 0.90 030 1.00 1.00 030 0.98 0.90 CC5A/CD5AW 024 0.98 1.00 CE3AA 024 0.98 0.91 030 1.00 1.00 030 0.98 0.89 CE3AA 024 0.99 1.00 CK3BA 024 0.97 0.89 030 1.01 1.00 030 0.98 0.89 CK3BA 024 0.98 1.00 CK5A/CK5BA 024 0.97 0.89 030 1.00 1.00 030 0.98 0.89 CK5A/CK5BA 024 0.98 1.00 CK5A/CK5BW 024 0.97 0.89 030 1.00 1.00 030 0.98 0.89 CK5A/CK5BW 024 0.98 1.00 COILS + 58MVP040-14 VARIABLE-SPEED FURNACE 030 1.00 1.00 CC5A/CD5AW 030 1.00 0.93 F(A,B)4(A,B)N(F,C) 024 0.99 0.99 CK5A/CK5BW 030 1.00 0.93 030 1.01 0.99 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE FC4(B,C)NF 024 0.99 1.00 CC5A/CD5AW 024 0.98 0.93 030 1.01 0.99 030 1.00 0.93 FF1DNA 024 0.99 1.01 CK5A/CK5BW 024 0.98 0.93 030 1.02 1.01 030 1.00 0.93 FG3AAA 024 0.97 0.99 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE FK4(C,D)NF 001 1.03 0.92 CC5A/CD5AW 024 0.98 0.93 002 1.03 0.92 030 1.00 0.93 003 1.04 0.91 CK5A/CK5BW 024 0.98 0.93 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE 030 1.00 0.93 CC5A/CD5AA 024 0.97 0.90 030 0.98 0.89 17