Supported Liquid Extraction (SLE) For Pharmaceutical Applications

Similar documents
Protect Your Mass Spec

Extraction of Acrylamide from Coffee Using ISOLUTE. SLE+ Prior to LC-MS/MS Analysis

APPLICATIONS TN Fast and Robust Analysis of Organic Acids from Wine using HPLC-UV. Introduction. Results and Discussion. Materials and Methods

Extraction of Multiple Mycotoxins From Animal Feed Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Application Note: Analysis of Melamine in Milk (updated: 04/17/09) Product: DPX-CX (1 ml or 5 ml) Page 1 of 5 INTRODUCTION

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

Zoe Grosser, Vinson Leung, Jim Fenster, Brian LaBrecque Horizon Technology, Inc., Salem, NH USA

EXTRACTION PROCEDURE

Determination of Pesticides in Coffee with QuEChERS Extraction and Silica Gel SPE Cleanup

Use of Accelerated Solvent Extraction (ASE) with Centrifugal Evaporation to Automate Fat Determination in Chocolate

The Determination of Pesticides in Wine

TSKgel TECHNICAL INFORMATION SHEET No. 131

PECTINASE Product Code: P129

Determination of Methylcafestol in Roasted Coffee Products According to DIN 10779

Higher Resolution Separation of Organic Acids and Common Inorganic Anions in Wine

Improved Cleanup of Pesticides in Dry, Difficult Matrices Using a Novel Dual-Layer SPE Cartridge for LC/MS/MS and GC/MS/MS Analysis

Rapid Analysis of Soft Drinks Using the ACQUITY UPLC H-Class System with the Waters Beverage Analysis Kit

Determination of Ochratoxin A in Roasted Coffee According to DIN EN 14132

High Sensitivity Quantitation Method of Dicyandiamide and Melamine in Milk Powders by Liquid Chromatography Tandem Mass Spectrometry

Avocado. recipe or working method? WLODEK. Wlodzimierz S. BOREJSZA-WYSOCKI Ph.D. IR-4 Southern Regional Laboratory Research Director

AppNote 13/2012. Automated Solid Phase Extraction (SPE)-LC-MS/MS Method for the Determination of Acrylamide in Brewed Coffee Samples KEYWORDS ABSTRACT

! " # # $% 004/2009. SpeedExtractor E-916

Analytical Method for Coumaphos (Targeted to agricultural, animal and fishery products)

Determination of Pesticide Residues in Red Wine

Ochratoxin A N H. N-{ [(3R)-5-chloro-8-hydroxy-3-methyl-1-oxo-3,4-dihydro-1H-isochromen-7-yl]carbon yl}- L-phenylalanine

Determination of Caffeine in Coffee Products According to DIN 20481

High-Resolution Sampling 2D-LC with the Agilent 1290 Infinity II 2D-LC Solution

ASSET EZ4-NCO Dry Sampler Extraction Procedure.

Automation of AOAC for the Identification of FD&C Color Additives in Foods using Solid Phase Extraction

RESOLUTION OIV-OENO ANALYSIS OF VOLATILE COMPOUNDS IN WINES BY GAS CHROMATOGRAPHY

Call for AOAC INTERNATIONAL Collaborator

The first and only fully-automated, random access, multiplex solution for Celiac IgA and Celiac IgG autoantibody testing.

EXTRACTION OF SEDIMENTS FOR AROMATIC AND CHLORINATED HYDROCARBONS

CHROMATOGRAPHY. Think about food Care about safety. Vol. 1 Melamine.

General overview of the two stages of the QuEChERS technique. Stage 1: Sample extraction. Stage 2: Sample cleanup

Application Note CL0311. Introduction

RAPID, SPECIFIC ANALYSIS OF MELAMINE CONTAMINATION IN INFANT FORMULA AND LIQUID MILK BY UPLC/MS/MS

Solid Phase Micro Extraction of Flavor Compounds in Beer

Profiling of Aroma Components in Wine Using a Novel Hybrid GC/MS/MS System

The first and only fully-automated, random access, multiplex solution for Celiac IgA and Celiac IgG autoantibody testing.

Analysis of trace elements and major components in wine with the Thermo Scientific icap 7400 ICP-OES

Solid Phase Micro Extraction of Flavor Compounds in Beer

One class classification based authentication of peanut oils by fatty

Vinmetrica s SC-50 MLF Analyzer: a Comparison of Methods for Measuring Malic Acid in Wines.

Determination of natamycin in wines Résolution OIV-SCMA

Determination of the concentration of caffeine, theobromine, and gallic acid in commercial tea samples

[ application note note ] ]

Enhancing the Flexibility of the NGC Chromatography System: Addition of a Refractive Index Detector for Wine Sample Analysis

Rapid Tea Analysis on Poroshell 120 SB-C18 with LC/MS

C27 Chromatography. Collect: Column Mortar and pestle Dropper (229 mm) Capillary tube TLC plate Aluminum foil UV light

Table 1: Experimental conditions for the instrument acquisition method

Yeast nuclei isolation kit. For fast and easy purification of nuclei from yeast cells.

Experiment 6 Thin-Layer Chromatography (TLC)

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

World Yoghurt Market Report

Acidity and ph Analysis

Extraction of Phenolic Acids from Plant Tissue Using Accelerated Solvent Extraction (ASE )

Bromine Containing Fumigants Determined as Total Inorganic Bromide

T Free Distillate 2085

DEVELOP. VALIDATE. TRANSFER.

Determination Of Saponin And Various Chemical Compounds In Camellia Sinensis And Genus Ilex.

COMPANY PROFILE Verdeoro srl.

A Fast Method for Sugar Analysis of Instant Coffee Samples

EXTRACTION OF SEDIMENTS FOR BUTYLTINS

POWERED BY NITRO COLD BREW COFFEE FULL EQUIPMENT LINE

Worm Collection. Prior to next step, determine volume of worm pellet.

Analysis of Beta-Carotene and Total Carotenoids from Pacific Sea Plasma (Spectrophotometric Method)

INTERNATIONAL STANDARD

SVENSK STANDARD SS-EN Foodstuffs Determination of ochratoxin A in barley and roasted coffee HPLC method with immunoaffinity column clean-up

KEEGAN & COPPIN COMPANY, INC.

POWERED BY COLD BREW NITRO COFFEE FULL EQUIPMENT LINE

Methanol (Resolution Oeno 377/2009, Revised by OIV-OENO 480/2014)

The delicate art of wine making. Alfa Laval Foodec decanter centrifuges in the wine industry

Introduction. Experimental. : : APPLICATION NOTE SP024: Pesticide Anaylsis: Standard QuEChERS vs Modified Method. : : APPARATUS: Geno/Grinder

The IWSR Global LOCAL KNOWLEDGE, GLOBAL INTELLIGENCE

ASTM D6042 Calibration Mixture

The impact of difficulties in EU-Russia trade relations on the Finnish foodstuffs sector

ION FORCE DNA EXTRACTOR FAST Cat. N. EXD001

Determination of Coumarins in Cosmetics

mott corporation P o r o u s M e t a l P r o d u c t s High-efficiency gas/liquid contacting.

Comparison across international sources of the value of exports for top 25 countries, 1992 (US$ billion )

PROPOXUR (075) EXPLANATION

Fluid Automation Solutions. for Winemaking.

Estimation of Caffeine Concentration in Decaffeinated Coffee and Tea Available in Pakistan

The Only Ceramic Grill That s Made in America...

Agilent J&W DB-624 Ultra Inert Capillary Column Screens Distilled Spirits by GC/MS Static Headspace

Where boutique wine producers and wine importers connect

Correlation of the free amino nitrogen and nitrogen by O-phthaldialdehyde methods in the assay of beer

An insight into the viticulture sector

Full Taste Zero Alcohol

HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

WINE EXPORTS. February Nadine Uren. tel:

Industry Advisory Panel Item 4c Trade of Stainless Steel Scrap

Speciated Arsenic Analysis in Wine Using HPLC-ICP-QQQ

DNA extraction method as per QIAamp DNA mini kit (Qiagen, Germany)

Major California Agricultural Exports to the Top Destinations in 1999* (1) Canada Rank Approximate Export Value (millions)

BOKELA BACKFLUSH FILTER

Interested in conducting your own webinar?

Somchai Rice 1, Jacek A. Koziel 1, Anne Fennell 2 1

Transcription:

Supported Liquid Extraction (SLE) For Pharmaceutical Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed Alternative to Traditional Diatomaceous Earth SLE Sorbents www.phenomenex.com/pharmasle

Choose the Best SLE Solution for Your Analysis Phenomenex provides two options for your SLE analysis, a unique synthetic sorbent and a traditional diatomaceous earth sorbent, each of which provides its own benefits. Select the best option for your work by using the chart below. simplified liquid extraction Supported Liquid Extraction Synthetic Sorbent Diatomaceous Earth Lot-to-lot consistency and reproducibility Ethyl Acetate, Methyl Tert-Butyl Ether (MTBE) MINI 96-Well Plates, MAX 96-Well Plates Advantages Extraction Solvents Plate Formats Cost effective and large volume capabilities Dichloromethane (DCM), Hexane, MTBE, Ethyl Acetate 200 µl 96-Well Plates, 400 µl 96-Well Plates Tube 1 cc, 3 cc, 6 cc, 12 cc 12 cc and 60 cc Formats Need Help Selecting the Right SLE Option? or Call us Live Chat www.phenomenex.com/livechat 2 Phenomenex l

Explore Your SLE Options and Applications Novum SLE A Unique, Synthetic Sorbent...p. 4 Strata Diatomaceous Earth (DE) SLE A Cost-Effective Alternative to Traditional SLE Sorbents...p. 5 Applications Basic Drugs from Plasma...p. 6 Nonsteroidal Anti-Inflammatory Drugs from Urine...p. 7 Nonsteroidal Anti-Inflammatory Drugs from Plasma...p. 8 Ordering Information...p. 9 Technical and Application Support...p. 10-11 Phenomenex l 3

Synthetic SLE simplified liquid extraction As a unique, synthetic SLE sorbent, expect Novum to provide reliable, more consistent lot-to-lot cleanup that excels under extraction conditions where traditional diatomaceous earth SLE falls short, such as ethyl acetate. Recommended Uses: Ethyl acetate extractions Smaller volume samples Lot to-lot Phospholipid Breakthrough: Novum SLE vs. Traditional Diatomaceous Earth SLE 100 % 90 % 80 % 70 % 60 % Biotage ISOLUTE SLE+ lot #13165345SA Biotage ISOLUTE SLE+ lot #12161236TA Novum Lot 1 Novum Lot 2 50 % 40 % 30 % 20 % 10 % 0 % Lyso 1 Lyso 2 PC 1 PC 2 PC 4 100 % 90 % 80 % 70 % 60 % 50 % 40 % 30 % 20 % Consistently remove > 99.9 % of phospholipids 0.010 % 0.008 % 0.006 % 0.004 % 0.002 % 10 % 0 % Lyso 1 Lyso 2 PC 1 PC 2 PC 4 0.000 % Lyso 1 Lyso 2 PC 1 PC 2 PC 4 Lyso 1: 1-Palmitoyl-2-OH-sn-glycero-phosphocholine (m/z 496-184) Lyso 2: 1-Oleoyl-2-OH-sn-glycero-phosphocholine (m/z 522-184) PC 1: 1-Palmitoyl-2-Oleoyl-sn-glycero-phosphocholine (m/z 761-184) PC 2: 1-Stearoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 787-184) PC 4: 1-Oleoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 784-184) Plasma extractions were performed using 200 µl plates and ethyl acetate as an elution solvent. The recommended protocol provided with each product was followed Comparative separations may not be representative of all applications. 4 Phenomenex l

Diatomaceous Earth simplified SLE liquid extraction Supported Liquid Supported Extraction Liquid Extraction Packed with diatomaceous earth, Strata DE is a cost-effective alternative to traditional SLE products such as Biotage ISOLUTE SLE+, Thermo Fisher Hypersep SLE, and Agilent Chem Elut SLE that won t require you to sacrifice your results. Recommended Uses: Direct alternative to traditional diatomaceous earth SLE sorbents Non-oxygenated extraction solvents such as DCM and Hexane Recovery Values and % CVs: Strata DE SLE vs. Biotage ISOLUTE SLE+ Analyte Strata DE % Recovery % CV (n=8) Biotage ISOLUTE SLE+ % Recovery % CV (n=8) Achieve the Same Recoveries as Biotage ISOLUTE SLE+, at a Lower Price! 6-MAM 98 9 88 16 Alprazolam 104 10 98 11 Benzoylecgonine 88 6 98 11 Buprenorphine 93 7 102 15 Codeine 99 12 93 9 Diazepam 107 7 104 6 Fentanyl 85 5 94 8 Hydrocodone 104 11 93 11 Hydromorphone 95 9 93 11 Lorazepam 94 8 98 8 Methamphetamine 92 16 102 8 Morphine 98 12 94 12 Norbuprenorphine 101 11 92 11 SLE Protocol 96-Well Plate: Part No.: Load: Wait: Strata DE SLE 400 µl 96-Well Plate Biotage ISOLUTE SLE+ 400 µl 96-Well Plate 8E-S325-5GB (Strata DE) 300 µl pre-treated sample onto plate (apply vacuum or positive pressure to pull/push sample into sorbent if necessary) 6 minutes Elute: 3x 600 µl Dichloromethane/IPA (95:5) Apply: Reconstitute: Vacuum or apply positive pressure at 5-10 Hg for 10 seconds Dry: Sample under slow stream of Nitrogen at 30 C 100 µl 0.1 % Formic Acid/Methanol (4:1) with internal standard Nordiazepam 100 9 92 8 Norfentanyl 113 7 110 11 Oxycodone 97 5 93 11 PCP 90 7 98 6 Comparative separations may not be representative of all applications. Phenomenex l 5

Basic Drugs from Plasma Many drugs within pharmaceutical labs are proprietary, "Basic Drug A" is analyzed as a representative drug that contains an amine group and hydrophobic ring structures, both of which are common to most pharmaceutical drugs. Sample Pre-treatment Dilute 150 µl Plasma with 140 µl 2 % NH 4 OH and 10 µl "Basic Drug A" spiking solution (1 µg/ml) SLE Protocol 96-Well Plate: Strata DE 200 µl Part No.: Load: Wait: Elute: Apply: Reconstitute: 8E-S325-FGB 200 µl Pre-treated sample onto plate (apply vacuum or positive pressure to pull/push sample into sorbent) 5 minutes 2x 600 µl Heptane Vacuum or apply positive pressure at 5-10 Hg for 10 seconds Dry: Sample under slow stream of Nitrogen at 30 C 100 µl Methanol/Water (80:20) with internal standard Heptane Extraction with High Recovery Automatable for High Throughput Processing Analyte % Recovery %CV (n=8) Basic Drug A 92 6 Intensity, cps Extracted Chromatogram After Clean-up Using Strata DE SLE 1.05e6 1.00e6 9.50e5 9.00e5 8.50e5 8.00e5 7.50e5 7.00e5 6.50e5 6.00e5 5.50e5 5.00e5 4.50e5 4.00e5 3.50e5 3.00e5 2.50e5 2.00e5 1.50e5 1.00e5 5.00e4 0.00 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min App ID 24663 LC-MS/MS Conditions Column: Kinetex 2.6 µm Biphenyl Dimensions: 50 x 2.1 mm Part No.: 00B-4622-AN Mobile Phase: A: 0.1 % Formic acid in Water B: 0.1 % Formic acid in Acetonitrile Gradient: Time (min) % B 0 20 3 70 4 70 4.01 20 5.5 120 Flow Rate: 0.5 ml/min Injection Volume: 5 µl Detection: MS/MS (SCIEX API 4000 ), ESI+ 6 Phenomenex l

NSAIDs from Urine Pre-treatment Dilute 100 µl of spike urine (100 ng/ml) with 100 µl of 0.1 % Formic acid. SLE Protocol 96-Well Plate: Strata DE 200 µl Part No.: Load: Wait: 8E-S325-FGB 200 µl Pre-treated sample 6 minutes Elute: 2x 600 µl Ethyl acetate/hexane (3:1) Reconstitute: Recovery Values Dry: Sample under slow stream of Nitrogen at 30 C 100 µl 0.1 % Formic acid in Methanol with 100 ng/ml concentration of Diclofenac D4, Acetaminophen D7, Naproxen D3 Small Sample Volume High Recovery for NSAIDs Cost Effective NSAID Extraction Acetaminophen Naproxen Diclofenac % Recovery 96 84 109 % RSD (n=8) 9 9 5 TIC for Extracted Sample Intensity, cps 8.8e5 8.5e5 8.0e5 7.5e5 7.0e5 6.5e5 6.0e5 5.5e5 5.0e5 4.5e5 4.0e5 3.5e5 3.0e5 2.5e5 2.0e5 1.5e5 1.0e5 5.0e4 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 min App ID 24614 LC-MS/MS Conditions Columns: Kinetex 2.6 µm C18 Dimensions: 50 x 2.1 mm Part No.: 00B-4462-AN Guard Cartridge: SecurityGuard ULTRA C18 Part No.: AJ0-8782 Mobile Phase: A: 0.1 % Formic acid in Water B: 0.1 % Formic acid in Acetonitrile Gradient: Time (min) % B 0 10 2.5 100 3.5 100 3.51 10 Flow Rate: 0.5 ml/min Injection: 3 µl Detection: MS/MS (SCIEX API 4000 ) Phenomenex l 7

NSAIDs from Plasma Sample Pre-treatment Dilute 200 µl Plasma with 200 µl of 1 % Formic acid in water. Vortex briefly (3-5 seconds). SLE Protocol 96-Well Plate: Part No.: Load: Wait: Novum SLE MAX 8E-S138-5GA Pre-treated sample and pulse vacuum (~5" Hg) for 5-10 seconds or until sample has completely entered the sorbent 5 minutes Elute: 2x 900 µl of % Ethyl acetate in Dichloromethane, allow to elute via gravity (~5 minutes per aliquot) Apply: Reconstitute: Vacuum or appply positive pressure at 5" Hg for 20-30 seconds to complete the elution Dry: Sample under slow stream of Nitrogen at 30 C 200 µl Methanol/Water (10:90) by vortexing the plate at 1400 rpm for 2 minutes Analyte % Average Recovery % CV Ibuprofen 82 6.70 Diclofenac 79 3.20 Naproxen 96 2.80 Ketoprofen 96 3.10 Mefenamic Acid 77 12.6 Flurbiprofen 82 12.0 Sulindac 87 10.1 Salicylic Acid 93 7.30 novum simplified liquid extraction Consistently High Recoveries Using Hexane/Ethyl Acetate (3:1) as Extraction Solvent Good Sensivitity of THC-COOH To learn more about Novum and Strata DE SLE products, go to www.phenomenex.com/sle 8 Phenomenex l

Start your new SLE Method Synthetic SLE Novum SLE 96-Well Plates Novum Simplified Liquid Extraction SLE Well Plates 8E-S138-FGA Novum SLE MINI 96-Well Plate 1/pk 8E-S138-5GA Novum SLE MAX 96-Well Plate 1/pk Diatomaceous Earth SLE Strata DE SLE 96-Well Plates Strata DE Diatomaceous Earth SLE Well Plates 8E-S325-FGB Strata DE SLE 200 µl 96-Well Plate 2/pk 8E-S325-5GB Strata DE SLE 400 µl 96-Well Plate 2/pk Novum SLE Tubes Novum Simplified Liquid Extraction SLE Tubes 8B-S138-FAK Novum SLE 1 cc Tubes 100/pk 8B-S138-5BJ Novum SLE 3 cc Tubes 50/pk 8B-S138-JCH Novum SLE 6 cc Tubes 30/pk 8B-S138-KDG Novum SLE 12 cc Tubes 20/pk Strata DE SLE Tubes Strata DE Diatomaceous Earth SLE Tubes 8B-S325-KDG Strata DE SLE 12 cc Tubes 20/pk 8B-S325-VFF Strata DE SLE 60 cc Tubes 16/pk If Phenomenex SLE products do not perform as well or better than your current SLE product, return the product with comparative data within 45 days for a FULL REFUND. Presston 100 Positive Pressure Manifold Presston 100 AH0-9334 Presston 100 Positive Pressure Manifold, 96-Well Plate ea AH0-9342 Presston 100 Positive Pressure Manifold, 1 ml Tube Complete Assembly ea AH0-9347 Presston 100 Positive Pressure Manifold, 3 ml Tube Complete Assembly ea AH0-9343 Presston 100 Positive Pressure Manifold, 6 ml Tube Complete Assembly ea Vacuum Manifolds Vacuum Manfolds AH0-6023 12-Position Tube Vacuum Manifold Set ea AH0-6024 24-Position Tube Vacuum Manifold Set ea AH0-8950 96-Well Plate Manifold, Universal with Vacuum Gauge ea The Presston 100 96-Well Positive Pressure Manifold can also process 1, 3, and 6 ml tubes using the following adapter kits: Presston 100 Tube Adapter Kits (for AH0-9334) AH0-9344 1 ml Tube Adapter Kit ea AH0-9345 3 ml Tube Adapter Kit ea AH0-9346 6 ml Tube Adapter Kit ea Phenomenex warrants that for a period of 12 months following delivery, the Presston 100 Positive Pressure Manifold you have purchased will perform in accordance with the published specifications and will be free from defects in materials or workmanship. In the event that the Presston 100 Positive Pressure Manifold does not meet this warranty, Phenomenex will repair or replace defective parts. Please visit www.phenomenex.com/ Presston for complete warranty information. Phenomenex l 9

We Develop Methods with You Free consultations for method development and optimization On-site method development Customer specific application development services It s OK if you don t have time to develop or run a sample preparation method yourself. Our full-service analytical support laboratory will do it for you. www.phenomenex.com/phenologix 10 Phenomenex l

Sample Preparation Resources Phenomenex l 11

Supported Liquid Extraction (SLE) For Pharmaceutical Applications Australia t: +61 (0)2-9428-6444 f: +61 (0)2-9428-6445 auinfo@phenomenex.com Austria t: +43 (0)1-319-1301 f: +43 (0)1-319-1300 anfrage@phenomenex.com Belgium t: +32 (0)2 503 4015 (French) t: +32 (0)2 511 8666 (Dutch) f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: +1 (800) 543-3681 f: +1 (310) 328-7768 info@phenomenex.com China t: +86 400-606-8099 f: +86 (0)22 2532-1033 cninfo@phenomenex.com Denmark t: +45 4824 8048 f: +45 4810 6265 nordicinfo@phenomenex.com Finland t: +358 (0)9 4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: +33 (0)1 30 09 21 10 f: +33 (0)1 30 09 21 11 franceinfo@phenomenex.com Germany t: +49 (0)6021-58830-0 f: +49 (0)6021-58830-11 anfrage@phenomenex.com India t: +91 (0)40-3012 2400 f: +91 (0)40-3012 2411 indiainfo@phenomenex.com Ireland t: +353 (0)1 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy t: +39 051 6327511 f: +39 051 6327555 italiainfo@phenomenex.com Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com Mexico t: 01-800-844-5226 f: 001-310-328-7768 tecnicomx@phenomenex.com The Netherlands t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com New Zealand t: +64 (0)9-4780951 f: +64 (0)9-4780952 nzinfo@phenomenex.com Norway t: +47 810 02 005 f: +45 4810 6265 nordicinfo@phenomenex.com Portugal t: +351 221 450 488 f: +34 91-413-2290 ptinfo@phenomenex.com Spain t: +34 91-413-8613 f: +34 91-413-2290 esp info@phenomenex.com Sweden t: +46 (0)8 611 6950 f: +45 4810 6265 nordicinfo@phenomenex.com Switzerland t: +41 61 692 20 20 f: +41 61 692 20 22 swissinfo@phenomenex.com United Kingdom t: +44 (0)1625-501367 f: +44 (0)1625-501796 ukinfo@phenomenex.com USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com All other countries Corporate Office USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR57950118_w Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www. phenomenex.com. Trademarks Strata and Kinetex are registered trademarks and Novum and Presston are trademarks of Phenomenex. Biotage and ISOLUTE are registered trademarks of Biotage AB Corp. Thermo Fisher and HyperSep are trademarks of Thermo Fisher Scientific. Agilent is a registered trademark and ChemElut is a trademark of Agilent Technologies, Inc. API 4000 is a trademark of AB SCIEX Pte. Ltd. AB SCIEX is being used under license. Disclaimer Phenomenex is not affiliated with Biotage AB Corp., Thermo Fisher Scientific, or Agilent Technologies, Inc. Novum is patent pending. 2018 Phenomenex, Inc.All rights reserved.