INSTRUCTION MANUAL Mi453 Reducing Sugars

Similar documents
INSTRUCTION MANUAL Milwaukee Wine Lab Photometer Mi454 Tartaric Acid

HI COLOR & PHENOLS ISM for wine analysis

INSTRUCTION MANUAL Mi455

INSTRUCTION MANUAL Mi456

HI FREE & TOTAL SULPHUR DIOXIDE MINITITRATOR for wine analysis

12 CUP COFFEE MAKER User Guide

HI Formol Number Mini Titrator for Wine and Fruit Juice Analysis

Alcohol Meter for Wine. Alcolyzer Wine

5KEK1322 W A_v08.indd 1 5/13/16 2:25 PM

BREW EXPRESS OPERATION GUIDE. model no. BE-112

12 CUP COFFEEMAKER User Guide

CMC DUO. Standard version. Table of contens

BREW EXPRESS OPERATION GUIDE MODEL BE112

CafeRomatica NICR7.. Fully automatic coffee centre Operating Instructions and Useful Tips. A passion for coffee.

Measuring Fluoride in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

1. IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric

CERTOMAT IS For controlled benchtop incubation

HANDMADE IN FLORENCE GS/3. Software Programming Guide. Version 1.09

HI Titratable Total Acidity Mini Titrator for Wine Analysis

TEA CATER USER MANUAL. UM_EN Part No.:

Acidity and ph Analysis

2016 Gourmia The Steelstone Group Brooklyn, NY

PECTINASE Product Code: P129

G F I M J K L B C D E S O T H Q P U N R D 4

E N T E R P R I S E S

Operating the Rancilio Silvia after PID kit modification Version 1.1

左边 :SAFTY NOTES 右边 : Please follow the safety precautions to avoid any harm to yourself and cause any damages Never Always Warning Attention

INSTRUCTION MANUAL. Coffee Maker CMCM-100

MODEL# GCM4500 COFFEE MAKER WITH GRINDER. PHOTO OF PRODUCT

A N F I M Srl. Caimano On Demand. Super Caimano COFFEE GRINDER C O D Y S C O D Y - II. Model

Triple Brew. Model #352. Coffee & Tea Maker. Instructions Warranty

SG120 Model # Cup Stainless Steel Coffee Maker. Operating Instructions Product Registration Warranty

Programmable Conical Burr Mill CBM-18

OWNERS MANUAL. My Rotisserie Pro Warranty. Please read and save this manual. PROFESSION AL SERIES MRP_MAN_QVC_ENG_V1_ FOR HOUSEHOLD USE ONLY.

AUTOMATIC BURR COFFEE GRINDER

OenoFoss. Instant quality control throughout the winemaking process. Dedicated Analytical Solutions

Quick Start Guide Read this booklet thoroughly and save these instructions.

IMPORTANT INSTRUCTIONS MODE D EMPLOI IMPORTANT INSTRUCIONES IMPORTANTES ISTRUZIONI IMPORTANTI

ELECTRONIC OVEN CONTROL GUIDE

User guide supplement. Built-in oven NZ AU. Soft Touch electronic models

Wi-Fi Coffee Maker. Model# GCMW-4750 USER MANUAL

AS450, AS600, G1, SG630

Matic / THa. Operating instructions COFFEE BREWER. Mode d emploi MACHINE À CAFÉ. Gebrauchsanleitung KAFFEEBRÜHMASCHINE

phd Pitcher UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

User Guide TEA CATER. Your Dealer. U / EN Rev

The Scoop 2-Way Brewer

User Manual. Stainless Steel Coffee Urns. Models: 177CU30, 177CU55, 177CU110 04/2018. Please read and keep these instructions. Indoor use only.

Service Manual SLG Grinder

5KEK1522 W A_01_EN.indd 1 11/16/12 1:22 PM

WE CAN HELP. Smart Coffee Maker User Manual. Can t connect? Need help? DO NOT RETURN THIS PRODUCT TO THE STORE

DE MANUAL BENUTZERHANDBUCH SM7683, SM7680 SM6080/SM6081/SM7080/SM7081 USER MANUAL BENUTZERHANDBUCH BENUTZERHANDBUCH

Lusso / Espresso Si' Models:PL-16 PAB-16. Made In Italy

CM200, Model # Cup Programmable Coffee Maker. Operating Instructions Product Registration Warranty

Oven Toaster Grill with Convection

Coffee Burr Grinder. Model #559. Instructions. Warranty

Coffeemaker User's manual

MT600 PLUS, Model #485 (Thermal) 10-Cup Programmable Coffee Maker with Stainless Steel Housing. Operating Instructions Product Registration Warranty

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

Calibrate grill heat zones Monthly GR 1 M1

VST inc. Lab Coffee III Digital Refractometer. Instructions for Base Models Coffee & Espresso. Read Instruction Manual Before Use.

Thank you for your purchase!

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS

DISCONTINUED VERSION The information in this manual is no longer current. Espresso/Cappuccino OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION

Pour Over Coffee Maker

10,000 prize draw. instructions. EXTRA year guarantee FREE rewards gallery. Register online now!

Booklet_TCG-357_ENG.qxd 9/8/08 11:19 AM Page 1 COFFEE/SPICE GRINDER. Instruction Booklet. Model: TCG-357

MG600 PLUS, Model #484 (Glass) 10-Cup Programmable Coffee Maker with Stainless Steel Housing. Operating Instructions Product Registration Warranty

SG Cup Coffee Maker. Model # W / 120Vac / 60 Hz. Operating Instructions Warranty

User Manual. Stainless Steel Coffee Urn. Models: 177CU30 11/2018. Please read and keep these instructions. Indoor use only.

User Manual. Stainless Steel Coffee Urns. Models: 177CU55ETL, 177CU110ETL 10/2016. Please read and keep these instructions. Indoor use only.

TOASTER OVEN USER MANUAL MODEL: PKMFT039

QUALITY MILK FROTHER INSTRUCTION MANUAL MODEL NO. MMF005

PIZZA OVEN & MULTI-GRILL

Alcolyzer Plus Spirits

Micro Casa Semiautomatica

MODEL: POD BREWER AURORA SAF 68 HOMEMAKER ESPRESSO MAKER WITH COFFEE POD

Any questions? Contact us at Telephone:

COFFEE MAKER INSTRUCTION MANUAL CM4682-V

The Column Oven Oven capabilities Oven safety Configuring the oven Making a temperature-programmed run Fast chromatography

3-in-1 K-Cup Coffee Maker

5.3QT DIGITAL 11-IN-1 INSTACOOKER Instruction Manual & Recipes MODEL CC5GT001

EXPERIMENT 6. Molecular Fluorescence Spectroscopy: Quinine Assay

CAIMANO SPECIAL450 BARISTA

SAFETY INSTRUCTIONS FOR USE

What's in the box 2 ENGLISH

Use & Care. All about the. of your Coffee Maker TA B L E O F C O N T E N T S. Brewing Your First Pot of Coffee USA and Canada

S m a rtset Control for Convection Models

Vinmetrica SC-50 MLF Analyzer User Manual

IMPORTANT SAFEGUARDS. When using electrical appliances, basic safety precautions should always be followed, including the following:

instructions COFFEE GRINDER KG 79/89

ORIGINAL LINE A USER MANUAL

Instructions for use for A1/A100

Fully Automatic Coffee Machine OPERATION MANUAL

User Manual. Thermo Pump System Coffee Brewers User Manual. Models: 177C10, 177C15 04/2018. Please read and keep these instructions. Indoor use only.

rm1a. MODEL# GYM1710

Deluxe Grind Conical Burr Mill CBM-20

Read the instructions, keep them safe, pass them on if you pass the appliance on. Remove all packaging before use.

A IMPORTANT SAFEGUARDS

Automatic Coffee Machine Instruction Manual

COFFEE MAKER KH COFFEE MAKER Operating instructions. KOMPERNASS GMBH BURGSTRASSE 21 D BOCHUM ID-Nr.

Transcription:

www.milwaukeetesters.com INSTRUCTION MANUAL Milwaukee Wine ine Lab Photometer Mi453 Reducing Sugars www.milwaukeeinst.com 1

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis TABLE OF CONTENTS FUNCTIONAL DESCRIPTION... 3 GENERAL DESCRIPTION... 4 SPECIFICATIONS... 6 GUIDE TO DISPLAY CODES... 7 GENERAL TIPS FOR AN ACCURATE MEASUREMENT... 8 MEASURENT PROCEDURE... 9 ERROR MESSAGES... 13 BATTERY REPLACEMENT... 14 ACCESSORIES... 15 2

www.milwaukeeinst.com FUNCTIONAL DESCRIPTION DISPLAY A. BATTERY STATUS ICON B. HOURGLASS ICON C. LAMP STATUS INDICATOR D. MEASURE STATUS E. MEASUREMENT UNIT F. MAIN DISPLAY G. PARAMETER NUMBER INDICATOR H. TIMER MODE INDICATOR I. SECONDARY DISPLAY FRONT PANEL A. LID B. CUVET HOLDER C. LIQUID CRYSTAL DISPLAY (LCD) D. ON/OFF KEY, TO TURN THE METER ON AND OFF E. ZERO KEY, TO START THE ZERO MEASUREMENT F. READ KEY, TO START THE SAMPLE MEASUREMENT G. TIMER KEY, TO ACTIVATE THE COUNTDOWN MODE TIMER 3

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis GENERAL DESCRIPTION Thank you for choosing Milwaukee. This instruction manual will provide you the necessary information for correct use of the meter. Mi453 is an auto-diagnostic portable microprocessor meter. It has an advanced optical system based on a special tungsten lamp and a narrow band interference filter that allows most accurate and repeatable readings. All instruments are factory calibrated. The auto-diagnostic feature of this meter ensures always optimal measurement conditions to perform most precise readings. The light level is automatically adjusted each time a zero-measurement is made, and the temperature of the lamp is controlled to avoid overheating. SIGNIFICANCE OF USE The determination of concentration of reducing sugars (RS) is one of the most important parameters that need to be measured during the wine making process. Following the increase of RS during maturation of grapes can help to decide when to start harvest. Having the highest possible sugar content is important because this is the main parameter that defines the commercial value of grapes. During the alcoholic fermentation instead, the decrease of sugars can be followed to decide when fermentation is completed, or allows making corrective actions if the content of RS is too low to obtain the desired alcohol degree or sweetness. The predominant RS in grape products are glucose and fructose (hexoses). After reaction with excess alkaline cupric tartrate (Fehling reagents), the RS content can be determined colorimetricly. The Fehling method is not an exact determination but an index of the reducing sugar concentration, because the reaction depends upon the amount and kind of RS present. When the reducing sugar content is known at the beginning of fermentation, the potential alcohol degree can be estimated multiplying the sugar concentration (in g/l) by 0.06. Phenols interfere in the Fehling reaction and therefore red wine must be decolorized prior to analysis. Wine also contains non-fermentable reducing sugars like pentose which will also be analysed by this method. 4

www.milwaukeeinst.com Typical content of reducing sugars in must and wine Must sweet must 20-25 % 200-250 g/l normal 10-20 % 100-200 g/l in fermentation 4-12.5 % 40-125 g/l Wine Sweet 2.5-12.5 % 25-125 g/l Semi sweet 0.8-2.5 % 8-25 g/l Almost dry 0.2-0.8 % 2-8 g/l Dry 0-0.2 % 0-2 g/l This meter is supplied with: Four sample cuvets and caps Reagents for 20 tests (Mi553-0, Mi553A-0, Mi553B-0) One 200 L automatic pipette with Instruction Sheet One 1000 L automatic pipette with Instruction Sheet Two plastic tips for 200 L automatic pipette Two plastic tips for 1000 L automatic pipette One spoon One funnel Filter paper (25 pcs) Four 1.5V AA batteries Tissue for wiping cuvets Instruction Manual Instrument Quality Certificate 5

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis SPECIFICATIONS Range 0.00 to 50.00 g/l Resolution 0.25 g/l Precision ±0.50 g/l @ 10.00 g/l Light Source Tungsten lamp Light Detector Silicon Photocell with narrow band interference filter @ 610 nm Method Fehling Method Environment 0 to 50 C (32 to 122 F) ; max 95% RH non-condensing Battery Type 4 x 1,5 volt AA batteries Auto-Shut off After 15' of non-use in measurement mode. Dimensions 225 x 85 x 80 mm (8.7 x 3.3 x 3.1") Weight 500 g (17,6 oz.). Required Reagents Code Description Quantity/test Mi553A-0 RS reagent A 1 test tube Mi553B-0 RS reagent B 1 ml Optional Reagents Code Description Quantity/test Mi553-0 Charcoal 2 spoons This instrument is in compliance with CE Directives. 6

www.milwaukeeinst.com PROBE GUIDE FUNCTIONAL TO DISPLAY DESCRIPTION CODES This prompt appears for a few seconds each time the instrument is turned ON. This prompt indicates the battery capacity value. Indicates that the instrument is in a ready state and waiting for the next command (Timer or Zero). After Timer is pressed, a blinking hourglass icon appears and the display shows a 7 minutes coundown. At the end of the countdown an acoustic signal alerts the user that the timer is finished. Indicates that the meter is performing a zero measurement. The light intensity is automatically readjusted (auto-calibration features) if necessary. The instrument is zeroed and a measurement can be made. Indicates that the meter is making a measurement. Batteries voltage is getting low and the batteries need to be replaced. 7

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis Indicates that the batteries are dead and must be replaced. After this message appears, the instrument is switched off. Change the batteries and restart the meter. GENERAL TIPS FOR AN ACCURATE MEASUREMENT The instructions listed below should be carefully followed during testing to ensure best accuracy. For dosing the wine sample and the reagent, we recommend to use the supplied Milwaukee automatic pipettes Mi0026 (200 L) and Mi0024 (1000 L). For a correct use of the Milwaukee automatic pipettes, please follow the related Instruction Sheet. Milwaukee automatic pipette All the reaction times reported in this manual are referred to 20 C (68 F). As a general rule of thumb, they should be doubled at 10 C (50 F) and halved at 30 C (86 F). USING VIALS Never insert hot vials into the instrument, or the cuvet holder may be damaged. In order to avoid reagent leaking and to obtain most accurate results, it is recommended to close the vial tightly with the supplied cap after addition of reagents or sample. Whenever the cuvet is placed into the measurement cell, it must be dry outside, and completely free of fingerprints, oil or dirt. Wipe it thoroughly with Mi0004 (tissue for wiping cuvets, see chapter ACCESSORIES) or a lintfree cloth prior to insertion. 8

www.milwaukeeinst.com DIGESTION At the end of the digestion period, the vials are still hot: allow the vials to cool to room temperature. MEASUREMENT PROCEDURE SAMPLE PREPARATION FOR RED WINE To remove interference of phenols, samples of Red Wine must be treated with activated carbon. Fill one cuvet with 10 ml of Red Wine. Add 2 spoons of Mi553-0 Charcoal to the cuvet. Cap the cuvet and mix vigorously for 2 minutes. Then wait for 3 minutes. Fold a filter disc twice as shown in the figure. Separate one side from the other three to form a cone. Insert the folded filter disc in the funnel. 9

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis Filter the treated wine into an empty cuvet. This is the wine sample. Note: if the filtered wine is still red, repeat the above procedure. MEASUREMENT Note: A single blank vial may be used more than once; the blank vial is stable up to one week if stored in a dark place at room temperature. Always use the same lot of reagents for blank and samples. For most accurate measurement run a blank for each set of mesurement. Note: If the expected RS concentration is above 50.00 g/l (for example for must analysis), it is recommended to dilute the sample 4 or 5 times with water. Preheat the reactor to 105 C (221 F). For a correct use of the reactor follow the Reactor Instruction Manual. Do not use an oven or microwave. Remove the cap from two vials Mi553A-0 RS reagent A. Use the Mi0024 1000 μl automatic pipette to add exactly 1 ml of Mi553B-0 RS reagent B to each vial. For a correct use of the automatic pipette please follow the related Instruction Sheet. wine sample deionized water Use the Mi0026 200 μl automatic pipette to add exactly 200 μl of wine sample to one vial (Sample) and 200 μl of deionized water to the other vial (Blank). Sample Blank 10

www.milwaukeeinst.com Replace the cap and invert the vials several times to mix. Wipe the vials thoroughly with a lint-free cloth. Insert the vials into the reactor and heat them for 7 minutes at 105 C. Note: to obtain most accurate results, it is recommended to use the pre-programmed timer of the instrument, and remove the vials from the reactor after exactly 7 minutes. Turn the meter on by pressing ON/OFF and then press TIMER to activate a 7 minutes countdown. At the end of the digestion period switch off the reactor, place the vials carefully in the test tube rack and wait for 10 minutes. Warning: as the vials are still hot, be careful in handling them. Note: If the sample vial appears brown/ orange without blue hue, dilute the wine sample and repeat the procedure. Invert the vials two times to mix. Then wait for 30 minutes to allow the vials cool to room temperature. Note: This operation is necessary to recover the condensed water after heating. Turn the instrument ON by pressing ON/OFF. When the LCD displays ---, it is ready. 11

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis Place the Blank Vial into the instrument. Blank Press ZERO and ---- will blink on the display. After a few seconds the display will show -0.0-. The meter is now zeroed and ready for measurement. Remove the Blank Vial. Insert the Sample Vial into the instrument. Note: Do not shake or invert the Sample Vial anymore otherwise the samples may become turbid. Sample Press READ and the display will show ---- during measurement. The instrument directly displays concentration in g/l (ppt) of Reducing Sugars on the Liquid Crystal Display. 12

www.milwaukeeinst.com Note: To convert the Reducing Sugars concentration from g/l to %, multiply the reading by 0.1. e.g. 12.5 g/l x 0.1=1.25%. When you analyse the must before alcoholic fermentation, to calculate the potential alcohol degree multiply the read sugar concentration (g/l) by 0.06. e.g. 175 g/l x 0.06=10.5% vol (potential alcohol degree) (potential alcohol degree) ERROR MESSAGES on zero reading: The meter has lost its configuration. Contact your dealer or the nearest Milwaukee Instruments Customer Service Center. Light high : there is too much light to perform a measurement. Please check the preparation of the zero cuvet. Light low : there is not enough light to perform a measurement. Please dilute the sample five times (see General tips for an accurate measurement, page 8). No Light : the instrument cannot adjust the light level. Please check that the sample does not contain any debris. 13

Instruction Manual Mi453 REDUCING SUGARS Photometer for wine analysis on sample reading: Inverted : the sample and the zero cuvet are inverted. The sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvet for reference (zero) and measurement. A flashing value of the maximum concentration indicates an over range condition. The concentration of the sample is beyond the programmed range: dilute the sample and measure again. BATTERY REPLACEMENT Battery replacement must only take place in a non-hazardous area. The blinking will appear when the batteries power gets low. When batteries are completely discharged, 0% batt will appear and after two seconds the instrument is switched off. Remove the battery cover from the bottom of the instrument and change the old batteries with 4 fresh 1.5V batteries, paying attention to the correct polarity. Replace the cover. 14

www.milwaukeeinst.com ACCESSORIES Reagent sets Mi453KIT Reducing sugars reagent set for wine (20 tests) OTHER ACCESSORIES Mi0006 1.5V AA batteries (4 pcs) Mi0004 Tissue for wiping cuvets (4 pcs) Mi0011 10 ml glass cuvets (2 pcs) Mi0014 Caps for cuvets (2 pcs) Mi0024 1000 L automatic pipette Mi0025 Plastic tips for 1000 L automatic pipette (25 pcs) Mi0026 200 L automatic pipette Mi0027 Plastic tips for 200 L automatic pipette (25 pcs) Mi0008 Filter discs (100 pcs) For your Safety don t use or store the instrument in hazardous environments. To avoid damages or burns, do not perform any measurement in microwave ovens. WARRANTY This instrument is warranted against defects in materials and manufacturing for a period of 2 years from the date of purchase. Electrodes are warranted for 6 months. If during this period the repair or replacement of parts is required, where the damage is not due to negligence or erroneous operation by the user, please return the intrument, electrode and probe to either distributor or our office and the repair will be effected free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered by the warranty. Milwaukee/Martini instruments reserves the right to make improvements in design, construction and appearance of its products without advance notice. 15

THANK YOU FOR CHOOSING Sales and Technical Service Contacts: Milwaukee Electronics Kft. Alsókikötő sor 11. 6726, Szeged, Hungary Tel: +36-62-428-050 Fax: +36-62-428-051 e-mail: sales@milwaukeeinst.com Milwaukee Instruments, Inc. 2950 Business Park Drive Rocky Mount, NC 27804 USA Tel: +1 252 443 3630 Fax: +1 252 443 1937 e-mail: sales@milwaukeetesters.com www.milwaukeeinst.com MANMI453R1 10/06