Citrus Quality Control Testing Manual

Similar documents
OECD GUIDANCE ON OBJECTIVE TEST TO DETERMINE QUALITY OF FRUITS AND VEGETABLES AND DRY AND DRIED PRODUCE. Ernst Semmelmeyer

Harvest times vary between growing regions and seasons. As an approximation, harvest times for the most common types are:

Royal Society of Chemistry Analytical Division East Anglia Region National Schools' Analyst Competition

IPPA SAG method revision 0,

Practical 1 - Determination of Quinine in Tonic Water

MATERIALS AND METHODS

CODEX STANDARD FOR LIMES (CODEX STAN , AMD )

Introduction to Measurement and Error Analysis: Measuring the Density of a Solution

DOMESTIC MARKET MATURITY TESTING

STANDARD DDP-04 concerning the marketing and commercial quality control of HAZELNUT KERNELS

Copyright JnF Specialties, LLC. All rights reserved worldwide.

COMMISSION IMPLEMENTING REGULATION (EU) No 543/2011 of 7 June 2011 EXCERPT: ANNEX I, PART B, PART 9 MARKETING STANDARD FOR TABLE GRAPES

Mastering Measurements

Chemistry 212 MOLAR MASS OF A VOLATILE LIQUID USING THE IDEAL GAS LAW

CODEX STANDARD FOR PINEAPPLES (CODEX STAN )

II. PROVISIONS CONCERNING QUALITY The purpose of the standard is to define the quality requirements for kiwifruit, after preparation and packaging.

STANDARD FOR PASSION FRUITS CODEX STAN

Acidity and ph Analysis

Micro Casa Semiautomatica

Shades from Shapes. Materials Required. Task 1: Movement of Particles

EDICT ± OF GOVERNMENT

5KCM0512A W A_ENv10.indd 1 10/13/15 12:41 PM

The Physico-Chemical Characteristics and Effect of Albumin Concentration and Whipping Time on Foam Density of Tomato Pulp

Chapter 14 Tex-619-J, Analysis of Water for Chloride and Sulfate Ions

CODEX STANDARD FOR QUICK FROZEN STRAWBERRIES 1 CODEX STAN

Lab 2-1: Measurement in Chemistry

Certified Home Brewer Program. Minimum Certification Requirements

Workshop on International Trade of Fresh Fruit and Vegetables: The role of Standards and Quality Inspection systems

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF UNBRUSHED 325 MESH GRIT, SLURRY METHOD: T

PECTINASE Product Code: P129

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Introduction to the General Chemistry II Laboratory. Lab Apparatus and Glassware

Buying Filberts On a Sample Basis

Experiment 3: Separation of a Mixture Pre-lab Exercise

Determination of Alcohol Content of Wine by Distillation followed by Density Determination by Hydrometry

UNECE STANDARD FFV-35 concerning the marketing and commercial quality control of STRAWBERRIES 2017 EDITION

Volume NaOH ph ph/ Vol (ml)

Setting up your fermentation

BLBS015-Conforti August 11, :35 LABORATORY 1. Measuring Techniques COPYRIGHTED MATERIAL

HARVEST & POST-HARVEST PRACTICES. Harvest Fermentation Drying Micro-fermentation HARVESTING FERMENTATION

CODEX STAN 293 Page 1 of 5

OPERATING MANUAL. Sample PRO 100 Series. Electric Heating. Applies to Versions: SPE1*, SPE2, SPE4, SPE6

UNECE STANDARD FFV-17 concerning the marketing and commercial quality control of FRESH FIGS 2014 EDITION

II. PROVISIONS CONCERNING QUALITY The purpose of the standard is to define the quality requirements for tomatoes, after preparation and packaging.

LABORATORY PRACTICES IN WINE ANALYSIS. Dpto. Nutrición y Bromatología II. Facultad de Farmacia. UCM

Experiment 2: ANALYSIS FOR PERCENT WATER IN POPCORN

The Separation of a Mixture into Pure Substances

Matic / THa. Operating instructions COFFEE BREWER. Mode d emploi MACHINE À CAFÉ. Gebrauchsanleitung KAFFEEBRÜHMASCHINE

BRIX AND ACID DETERMINATIONS. E. Echeverria. University of Florida, IFAS Citrus Research and Education Center Lake.Alfred

Application Note No. 184/2015

REGIONAL STANDARD FOR LUCUMA (CODEX STAN 305R )

Science & Technology of Jams and Jellies. Dr. Malcolm Bourne

Tomato Product Cutting Tips

PROPOSED DRAFT STANDARD FOR AUBERGINES (At Step 5/8)

Grooving Tool: used to cut the soil in the liquid limit device cup and conforming to the critical dimensions shown in AASHTO T 89 Figure 1.

UNECE STANDARD FFV-05 concerning the marketing and commercial quality control of AUBERGINES 2010 EDITION

ASEAN STANDARD FOR YOUNG COCONUT (ASEAN Stan 15:2009)

TCAT FRUITS: VARIOUS TYPE (FOR SFS)

Gravimetric Analysis

C27 Chromatography. Collect: Column Mortar and pestle Dropper (229 mm) Capillary tube TLC plate Aluminum foil UV light

UNECE STANDARD FFV-05 concerning the marketing and commercial quality control of AUBERGINES 2016 EDITION

Station 1. Polarity of Water

Award Winning Canning. Brenda Hill, Ph.D. Family Consumer Science Educator Cleveland County Extension 2015

Overview. Hydrometer Selection. About Specific Gravity. Conditions Affecting Hydrometer Accuracy

D Lemmer and FJ Kruger

Gravimetric Analysis

EQUIPMENT FOR MAKING BABCOCK TEST FOR FAT IN MILK

Unit F: Harvesting Fruits and Nuts. Lesson 1: Harvest Tree Fruits, Small Fruits, And Nuts

Nominal 225kg Aseptic Brix Pizza Sauce packed in an Aseptic Bag placed in a mild steel drum

Specialized Section on Standardization of Dry and Dried Produce REVISION OF UNECE STANDARDS INSHELL WALNUTS

Activity Instructions

INSTRUCTION MANUAL Mi453 Reducing Sugars

Business Guidance leaflet

Separating the Components of a Mixture

European Community common position on. Agenda Item 4 b) CODEX COMMITTEE ON FRESH FRUITS AND VEGETABLES (12 th Session)

Dispensing Techniques

EC Common position Draft Codex standard for apples Document CX/FFV 02/9

Hybrid Seeds Production

CODEX STANDARD FOR QUICK FROZEN WHOLE KERNEL CORN CODEX STAN

LAB: One Tube Reaction Part 1

Separating the Components of a Mixture

HI-1017: Pharmacy Technician. Module 10 Pharmacy Equipment

2. Other constituents in the sample solution should not interfere with the precipitation of the component of interest.

Seville Orange Marmalade Step By Step

CAUTION!!! Do not eat anything (Skittles, cylinders, dishes, etc.) associated with the lab!!!

National Food Safety Standard

Module 6. Yield and Fruit Size. Presenter: Stephan Verreynne

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

UNECE STANDARD FFV-27 concerning the marketing and commercial quality control of PEAS 2010 EDITION

EXPERIMENT NO. 3 HYDROMETER ANALYSIS ASTM D-422

Liquajuice Pro Slow juicer

INSHELL MACADAMIA NUTS

STANDARD FOR QUICK FROZEN BLUEBERRIES CODEX STAN

AMINOFIT.Xtra, SOME TEST RESULTS

Notes on acid adjustments:

Produce Specifications

Predicting Susceptibility of Gala Apples To Lenticel Breakdown Disorder: Guidelines for Using the Dye Uptake Test

NEW ZEALAND AVOCADO FRUIT QUALITY: THE IMPACT OF STORAGE TEMPERATURE AND MATURITY

Making Hard Cider. A Guide for Small-Scale Producers. Lee Elliot Williams. Bellevue College. Technical Writing Certificate Program

INF.3 Proposal for a new UNECE Standard: Inshell Pecans

Transcription:

SUPPORT TO THE DEVELOPMENT OF THE AFGHANISTAN AGRICULTURE PRIVATE SECTOR: PERENNIAL HORTICULTURE DCI-ASIE/2013/335-321 Strategic Objective 4: A soundly based and profitable Citrus Industry in Eastern Afghanistan is developed Citrus Quality Control Testing Manual March 2015 This programme is funded by the European Union This file is downloaded from http://anhdo.org.af i

Citrus Step By Step Quality Standard Testing Manual We recognize quality is important so we have developed a simple set of citrus quality standards outlined in the following testing Manual. The purpose to develop this manual is aim to assist growers, packers, marketers and retailers consistently deliver quality citrus that consumers can enjoy with confidence. There are three key factors that encourage consumers back to purchase more citrus fruit: > The level of juiciness > The level of sweetness > A good balance between sweetness and acid. Following an analysis of consumer research and commercial standards, minimum standards for these three factors were unanimously agreed upon by the whole of industry. The internal maturity of citrus differs between citrus types and varieties so there are different standards for each citrus type and where necessary variety. The Citrus Quality Standards refer to the percentage of juice in a fruit, the amount of sugars (measured in degrees Brix) and the sugar to acid ratio. Developing these standards has been about maintaining and expanding market share and reinvigorating consumer confidence in citrus fruit. We all acknowledge that, in recent years, the competition for the consumers dollar has intensified by adopting these standards and delivering consistently good tasting fruit to the consumer we think we ll see more dollars in growers pockets. A simple and effective, 5 step guide to assist, Growers, Packers, Retailers & Marketers and in the quality testing process. This file is downloaded from http://anhdo.org.af ii

Table of Content S/N Title Page 1 Citrus Maturity Test Record Sheet iv 2 Equipment required v 3 Citrus Quality Testing Instructions vi 4 Step 1 > Collect a sample 1 5 Step 2 > Measure the juice content 2 6 Step 3 > Measure the o Brix 3 7 Step 4 > Measure the acid content 5 8 Step 5 > calculate the Sugar: Acid ratio 9 9 Step 6 > Measure the firmness 10 This file is downloaded from http://anhdo.org.af iii

Citrus Maturity Test Record Sheet A copy of this record sheet should be used each time a new citrus maturity test is conducted Date: QC: Sample ID: Fruit Weight Juice weight g g Acid % Pass/Fail Juice % Brix o Brix: acid ratio Comments: Equipment Required 1. Good quality scales with 1g graduations, at least 3kg maximum 2. 1 to 2 litre jug or beaker 3. Fine sieve with 1-2mm mesh range 4. 0.1% sodium hydroxide (NaOH) This file is downloaded from http://anhdo.org.af iv

5. 1% phenolphthalein indicator 6. Fruit juicer (manual or electric ream only - no centrifugal, masticating or twin gear juicers) 7. 100mL conical flask or 100mL beaker 8. Refractometer (digital or hand-held - must be temperature compensated, with a 0-32%) 9. 50mL burette (auto-fill burette pictured on page 10) 10. 10mL pipette and pump 11. Kitchen knife 12. 1 litre volumetric flask (not pictured) 13. Distilled water and squeeze bottle (not pictured) 14. Tissues (not pictured) This file is downloaded from http://anhdo.org.af v

Citrus Quality Testing Instructions You can decide if a batch of citrus is acceptable for eating by following these S easy steps: Step 1: Collect the sample which is to be tested from each orchard block Step 2: Step 3: Step 4: Measure the juice content of the fruit. Measure the sugar level (also known as the Brix o ) of the juice. Measure the acid level of the juice. Step 5: Calculate the sugar-acid ratio by dividing the Brix o by the acid. Step 6: Measuring the Firmness of Citrus Fruits This file is downloaded from http://anhdo.org.af vi

Step 1 > Collect a sample You will need at least 10 pieces of fruit, however, the more fruit you test the greater the accuracy of your result. For smaller fruit such as mandarins, 20 pieces of fruit is preferable. Orchard samples Your sample must be typical of what you are planning to pick. For example, if you plan to select pick, then collect fruit of the same size and/or colour that you will be picking. If you plan to strip pick, then collect an even mix of Fruit of all the sizes and colours on the tree be sure not to only pick the fruit that is most coloured! In both cases, you must collect fruit from all sides of the trees as well as inside the canopy. You must also collect fruit from at least 10 trees spread throughout the block. Make sure all the fruit are sound, with no rots or rind punctures. You will need separate samples from each block or patch if the variety, rootstock, tree age or soil type is different because all these things will affect the taste of the fruit. Pack-house, Market and Distribution Centre samples The sample must be typical of a whole consignment do not collect all the fruit from just one carton. When checking a pallet, take no more than two pieces of fruit from each carton therefore you will need to collect fruit from at least five cartons. Preferably collect one fruit from each of 10 cartons. If you are checking a consignment of many pallets, make sure you take fruit from each pallet, and from as many cartons as possible. The golden rule is: spread it out as much as possible. Make sure all the fruit you select are sound, with no rot or rind punctures. 1

Step 2 > Measure the juice content 1. Place a clean tray on the scales and push the Tare or Zero button. 2. Place your fruit sample on the tray and record the weight, to the nearest gram (g). 3. Juice all the fruit using the ream juicer, push down evenly to remove all the juice. 4. Place a clean, dry jug or beaker on the scale and push the Tare or Zero button. 5. Pour the juice through a 1-2mm mesh sieve into the jug/beaker. 6. Record the juice weight, to the nearest g. 7. Divide the juice weight by the fruit weight and multiply this by 100 to get the juice Percentage. Example calculation: Fruit weight = 600g Juice weight = 288g Juice weight Fruit weight x 100 = percentage (%) juice 288 grams 600g x 100 = 48% juice 2

Weigh sample and record Results. Tare or zero the Scales when using a tray Sieve juice through a fine (1-2mm mesh) Sieve before weighing Step 3 > Measure the Brix o Use a refractometer to measure Brix o. There are two types: > Hand-held refractometers, which have a prism with a lid for holding the juice sample. > Digital refractometers, which have a well for holding the juice sample. Calibrating your refractometer Always calibrate your refractometer at the start of the day, and then again after every 10 readings. To calibrate the refractometer: 1. Wipe the prism or well with distilled water and dry with a clean tissue. 2. Add a couple of drops of distilled or deionized water onto the prism/well. 3. Zero the refractometer and then wipe the prism/well dry with a tissue. 4. You are now ready to test your juice samples. 3

Using a Hand-Held Refractometer 1. First clean and dry the prism using distilled water and a clean tissue. 2. Place a couple of drops of the fresh juice onto the prism/well. 3. Look through the eyepiece while aiming the prism towards good light (not the sun). 4. Focus the eyepiece and take the reading Where the base of the blue colour sits on The scale. Direct the refractometer to a good light 5. Record the Brix o figure and then clean the prism with distilled water and a clean tissue. Using a digital refractometer 1. First clean and dry the well using distilled water and a clean tissue. 2. Place a couple of drops of the fresh juice onto the well. 3. Press the Start button and record the Brix o reading. 4. Clean the well with distilled water and a Clean tissue. Digital refractometer. 4

Temperature correction table for Brix to standard temperature 20 C Step 4 > DETERMINATION OF FRUIT ACIDS BY TITRATION It is the sugar/acid ratio which contributes towards giving many fruits their characteristic flavor and so is an indicator of commercial and organoleptic ripeness. At the beginning of the ripening process the sugar/acid ratio is low, because of low sugar content and high fruit acid content, this makes the fruit taste sour. During the ripening process the fruit acids are degraded, 5

the sugar content increases and the sugar/acid ratio achieves a higher value. Overripe fruits have very low levels of fruit acid and therefore lack characteristic flavour. Titration is a chemical process used in ascertaining the amount of constituent substance in a sample, e.g. acids, by using a standard counter-active reagent, e.g. an alkali (NaOH). Once the acid level in a sample has been determined it can be used to find the ratio of sugar to acid. There are two methods specified for the determination of the titratable acidity of fruits: -Method using a coloured indicator; -Potentiometric method, using a ph meter, which should be used for very coloured juices. Material: - A laboratory burette of 25 or 50ml capacity or an automatic burette is used. A 10ml pipette, beaker (250ml), a filter (muslin cloth or fine filter) and an extractor or homogenizer. - A bottle of distilled water. - Sodium Hydroxide (NaOH): The Standard Laboratory solution of 0.1M which is used in the actual titration is considered to be dilute, and can readily be purchased in this form. - Phenolphthalein: This is a 1% w/v solution of phenolphthalein in 95% v/v ethanol Which is flammable and toxic if ingested. This is only required for the method using a coloured indicator. - Indicator stripes to check the exact point of neutrality an indicator stripe should be used. Not necessary if ph Meter is used. Sampling 6

To evaluate the lot selected for inspection, take a sample of at least 10 fruits of each size at random from the reduced sample. However, fruits should be free from defects such as sun scorch and pest or disease damage, which may have affected the normal ripening process. Sample preparation Depending upon the type of produce, either cut the fruit in half and squeeze out the juice with an extractor or a juice-press e.g. citrus fruits, or homogenize the flesh into a pulp. The juice of all squeezed fruits is mixed. The skin and solids should not be included; the solids being filtered out through muslin cloth or fine filter extracting as much juice as possible. Use a clean and dry safety 10ml pipette. Draw up 10ml of juice and discharge it into a 250ml beaker. Using another clean and dry pipette draw up 50ml of distilled water and add to the juice in the beaker. Measurement: Method using a coloured indicator Add 3 drops of phenolphthalein to the juice/water solution in each beaker from a dropping pipette which is specifically kept for that purpose. Ensure the tap on the burette is shut and using a funnel pour the 0.1M solution of NaOH into the burette until it reaches the zero mark. Do not spill the solution onto the skin. Slowly titrate the NaOH into the juice/water solution (with a 25ml burette or an automatic burette). Care must be taken that the NaOH is dropped directly into the solution and does not adhere to the glass, otherwise the reading may be false. While titrating care must be taken to continually swirl the solution in the beaker to keep it thoroughly mixed. This is essential, particularly when the solution nears neutrality. It is important to determine the point of neutrality or the end point of titration very exactly. The phenolphthalein indicator changes very rapidly from colourless to pink and the end point can easily be missed, which will give an inaccurate reading for the test. It is important therefore that towards the end of the titration the NaOH is added a drop at a time. Using phenolphthalein as an indicator, the point of neutrality is reached when the indicator changes from colourless to pink. The indicator colour must remain stable (persisting for 30 seconds) and be light pink when viewed over a white background. However, the shade can vary depending on the type of juice being tested. If the point of neutrality is missed, i.e. the colour of the indicator is too dark, the test is not acceptable and must be repeated. An indicator stripe should be used to avoid the neutral point of ph 8.1. 7

- Read off the amount of the amount of NaOH used (titre) on the burette and record this figure. - Re-fill the burette for each subsequent test. - Clean the equipment thoroughly and rinse with distilled water. Detergents must not be used. Auto-fill burette simply squeeze the Bottle to fill the burette Adding the 0.1% sodium hydroxide to the juice and phenolphthalein solution. Note the swirl of pink in the sample. Note: When testing very acidic juices e.g. lemons and limes a larger amount of NaOH is required. Therefore, when the NaOH reaches the 25ml mark on the scale the burette tube should be recharged as described above. When the end point is reached the various readings are added together and recorded to produce a figure of NaOH used for each titration. Method using a ph meter The point of neutrality i.e. the end point of titration may also be determined using a ph meter. The precise method used will depend on the manufacturer instructions, but the following will provide a general guide. Checking the ph meter - Make sure the ph meter has warmed up before use - allow about 30 minutes. - Remove the electrode from the distilled water in the storage beaker and dry. 8

- Place the electrode into the beaker containing a buffer solution of ph 7 and calibrate the meter to the same figure. - Whenever readings are taken, ensure that the electrode is not in contact with the sides or base of the beaker. - Remove the electrode and - after rinsing in distilled water - place in the solution to be tested; the electrode should not have any contact with the glass. Measurement Ensure the tap on the burette is shut and using a funnel pour the 0.1M solution of NaOH into the burette until it reaches the zero mark. Do not spill the solution onto the skin. Slowly titrate the NaOH into the juice/water solution. Care must be taken that the NaOH is dropped directly into the solution and does not adhere to the glass, otherwise the reading may be false. While titrating care must be taken to continually swirl the solution in the beaker to keep it thoroughly mixed. This is essential, particularly when the solution nears neutrality. It is important to determine the point of neutrality or the end point of titration very exactly. The end point can easily be missed, which will give an inaccurate reading for the test. It is important therefore that towards the end of the titration the NaOH is added a drop at a time. Using a ph meter, while titrating the digital readout will be seen to climb from around 4 or 5. When the reading reaches 7 proceed carefully. The point of neutrality or the end point of titration is reached at ph 8.1. If this figure is exceeded the test is not acceptable and must be repeated. - When the ph meter reads 8.1 read off the amount of NaOH used on the burette and record. - Remove the electrode and rinse it in distilled water ready for the next test. Do not allow it to become contaminated. - Re-fill the burette for each subsequent test. - Clean the equipment thoroughly and rinse with distilled water. Detergents must not be used. Note: When testing very acidic juices e.g. lemons and limes a larger amount of NaOH is required. Therefore, when the NaOH reaches the 25ml mark on the scale the burette tube should 9

be recharged as described above. When the end point is reached the various readings are added together and recorded to produce a figure of NaOH used for each titration. Step 5 > Calculation of the Sugar/Acid Ratio The Brix value of the fruit concerned must also be obtained before calculation of the sugar/acid ratio is possible. The calculations for determining the sugar/acid ratios of all produce are the same, but as some products contain different acids the appropriate multiplication factor must be applied to each calculation. Some products may contain more than one type of acid, it is the primary acid that is tested. A list of these acids and multiplication factors are found below. Factor for: - citric acid : 0.0064 (Citrus fruit) - malic acid : 0.0067 (Apples) - tartaric acid : 0.0075 (Grapes) Using citric acid as an example, 1ml 0.1M NaOH is equivalent to 0.0064g citric acid. Results expressed as percentage acid: Percentage acid = Titre x acid factor x 100 10 (ml juice) The sugar acid ratio = Brix value Percentage acid OR Results expressed as acid in gram/litre: g/l acid = Titre x acid factor x 100 x 10 10

10 (ml juice) The sugar acid ratio = Brix value x 10 g/l acid E.g.: In case of citric acid the result would be expressed as: Percentage citric acid Gram/ litre acid Percentage Citric Acid = Titre x 0.0064 x 100 10ml juice g/l Citric Acid = Titre x 0.0064 x 100 x 10 10 (ml juice) This formula can be simplified to: Percentage Citric Acid = Titre x 0,064 This formula can be simplified to: g/l Citric Acid = Titre x 0,64 The sugar acid ratio = Brix value Percentage acid The sugar Acid Ratio = Brix value x 10 g/l Citric Acid Health and Safety Guidelines Sodium Hydroxide in its undiluted form is extremely corrosive to body tissue. Skin contact causes irritation almost immediately and continued contact causes burns. The 0.1 Molar solution used in this test is much safer. However, it is recommended that protective coats are worn when using, and that it is used only in a well-ventilated room. Phenolphthalein is highly flammable and should be used with care. It should be stored and used away from naked flames or other sources of ignition. It is toxic if ingested. Step 6 > MEASUREMENT OF CITRUS FRUITS FIRMNESS BY PENETROMETER The firmness of a fruit is linked to the state of maturity and ripeness and may be influenced by the variety as well as the region of production and the growing conditions. This document describes an objective test to determine the firmness of fruit by means of a penetrometer. The 11

penetrometer is used by producers, packers and distributors to help to determine the stage of ripeness of a fruit and by the retail trade to determine palatability for the consumer and shelf life for their own records. The determination of firmness of a fruit by means of the penetrometer is based on the pressure necessary to push a plunger of specified size into the pulp of the fruit up to a specific depth. Material Penetrometers are available with dial gauges calibrated in both metric (kg) and imperial (lbs) measurements and can be obtained to cover different ranges of pressure suitable for measuring either soft or harder types of fruit, depending on the variety and the stage of ripeness of the produce to be tested. Stand Model Penetrometer Hand Held Penetrometer The detachable plungers are available below: - One of 8 mm (½ cm²) diameter generally suitable for use in testing softer produce 12

(e.g. peaches, nectarines, plums), - one of 11 mm (1 cm²) diameter generally suitable for use in testing harder fruit (e.g. Citrus, apples, pears) and Ideally the penetrometer should be bench-mounted on a fixed, rigid drill stand to ensure that pressure is applied at a steady controlled rate and at a constant angle to the fruit i.e. vertically downwards. This is more difficult to achieve when using a hand-held penetrometer. If it is not practical to use a stand mounted penetrometer and it is necessary to use a hand- held one as in the field or market place - then particular care must be taken to ensure a smooth and uniform application of pressure when taking readings. The method is the same for both the hand-held and the mounted penetrometer and must be identical for each item of produce tested in order to obtain consistent results. If testing is done in a laboratory, a stand-model penetrometer should be used. Sampling To evaluate the lot selected for inspection, take a sample of at least 10 fruits of each size at random from the reduced sample. However, fruits should be free from defects such as sun scorch and pest or disease damage, which may have affected the normal ripening process. Sample Preparation From two opposite sides of the equatorial area of the fruit a disc of peel (only skin depth) of up to 2 cm² (¾ sq. ins) is removed. Where fruit is of mixed colour, e.g. apples, the tests should be carried out where possible between the highest and the lowest colored portion of the surface. Measurement Hold the fruit firmly with one hand, rest it on a rigid surface, such as a table top or the plate at the base of the stand. The choice of plunger size and scale range used will depend on the type 13

and the variety of the produce being tested and its stage of maturity and ripeness. If the size of plunger is mandatory in marketing standards, the given size has been used. It is recommended that the size of the plunger chosen and the particular scale used should be such as to give readings in the middle range of the scale. Zero the penetrometer and place the plunger head against the flesh in the peeled area of the fruit. Apply steady downward pressure until the plunger has penetrated the flesh of the fruit up to the depth mark (half way up) on the plunger. Slow, steady pressure is essential as sharp uneven movements may give unreliable results. Remove the plunger and note the reading on the penetrometer dial, to one decimal place. Repeat the process on the opposite side of the same fruit after first zeroing the penetrometer. It is very important to conduct all tests as uniformly and carefully as possible in order to allow an accurate comparison of results. 14

15